首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

2.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

3.
Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single‐source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30‐min lysis step, a 27‐min DNA extraction using the Promega Maxwell®16 System, DNA quantification in <1 h using the Qiagen Investigator® Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpF?STR® Identifiler®, and analysis of the profiles on the 3500‐series Genetic Analyzer. This combination of fast individual steps produces high‐quality profiling results and offers a cost‐effective alternative approach to rapid DNA analysis.  相似文献   

4.
A new rapid DNA solution, the RapidHIT®ID, can accommodate two different sample cartridges, ACE, for the analysis of a single swab and EXT, for the analysis of DNA extracts. An efficient internal validation designed for low‐throughput rapid DNA is described. An evaluation of the EXT sample cartridge is also described. Each cartridge generated profiles with sufficient data quality to meet CODIS eligibility in fewer than 120 min. The results exhibited 100% correlation when compared to conventional DNA typing methods. Precision, reproducibility, stochastic, mixture, and contamination experiments produced expected results. Sensitivity of the ACE sample cartridge was acceptable for buccal swab analysis. The sensitivity of the EXT sample cartridge is discussed. The ACE validation and the EXT evaluation utilized a minimalist, cost‐saving, efficient design to generate a validated RapidHIT®ID instrument capable of producing genetic profiles from both extracted forensic DNA samples and buccal swab samples within 120 min.  相似文献   

5.
Abstract: Automated platforms used for forensic casework sample DNA extraction need to be versatile to accommodate a wide variety of sample types, thus protocols frequently need modification. In this study, DNA IQ? methods previously developed for the Biomek® 2000 Automation Workstation were adapted for the Teleshake Unit using normal volumes and all deepwell extraction, and a large volume DNA IQ? method developed. DNA purification without detectable contamination of adjacent reagent blanks is reported in the extraction of tissue samples containing several micrograms of DNA. Sensitivity and contamination studies demonstrated similar performance with the manual organic extraction method for bloodstain dilution samples. Mock casework samples demonstrated the effectiveness of the Teleshake and Teleshake large volume methods. Because of the performance and increased versatility of the DNA IQ? extraction with these modifications, the Teleshake Unit has been implemented in both normal and large volume automated DNA extractions at the Virginia Department of Forensic Science.  相似文献   

6.
There has been minimal research into how to best obtain DNA from touch samples. Many forensic laboratories simply moisten a swab with water and use it for collecting cells/DNA from evidentiary samples. However, this and other methods have not been objectively studied in order to maximize DNA yields. In this study, fingerprints were collected using swabs moistened with water or laboratory or commercially available detergents, including sodium dodecyl sulfate (SDS), Triton X‐100, Tween 20, Formula 409®, and Simple Green®. Prints were swabbed, DNA isolated using an organic extraction, yields quantified, and relative yields compared. In all cases, the detergent‐based swabbing solutions outperformed water, with SDS and Triton X‐100 producing significant increases in yield. Short tandem repeat profiles were consistent with the individuals that placed them. Subsequent analysis of SDS concentrations for collecting touch DNA demonstrated an increase in DNA yield with increasing SDS concentration, with an optimal concentration of approximately 2%.  相似文献   

7.
Next‐generation sequencing technologies enable the identification of minor mitochondrial DNA variants with higher sensitivity than Sanger methods, allowing for enhanced identification of minor variants. In this study, mixtures of human mtDNA control region amplicons were subjected to pyrosequencing to determine the detection threshold of the Roche GS Junior® instrument (Roche Applied Science, Indianapolis, IN). In addition to expected variants, a set of reproducible variants was consistently found in reads from one particular amplicon. A BLASTn search of the variant sequence revealed identity to a segment of a 611‐bp nuclear insertion of the mitochondrial control region (NumtS) spanning the primer‐binding sites of this amplicon (Nature 1995;378:489). Primers (Hum Genet 2012;131:757; Hum Biol 1996;68:847) flanking the insertion were used to confirm the presence or absence of the NumtS in buccal DNA extracts from twenty donors. These results further our understanding of human mtDNA variation and are expected to have a positive impact on the interpretation of mtDNA profiles using deep‐sequencing methods in casework.  相似文献   

8.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

9.
A developmental validation was performed to demonstrate reliability, reproducibility, and robustness of the ANDE Rapid DNA Identification System for processing of crime scene and disaster victim identification (DVI) samples. A total of 1705 samples were evaluated, including blood, oral epithelial samples from drinking containers, samples on FTA and untreated paper, semen, bone, and soft tissues. This study was conducted to address the FBI’s Quality Assurance Standards on developmental validation and to accumulate data from a sufficient number of unique donors and sample types to meet NDIS submission requirements for acceptance of the ANDE Expert System for casework use. To date, no Expert System has been approved for such samples, but the results of this study demonstrated that the automated Expert System performs similarly to conventional laboratory data analysis. Furthermore, Rapid DNA analysis demonstrated accuracy, precision, resolution, concordance, and reproducibility that were comparable to conventional processing along with appropriate species specificity, limit of detection, performance in the presence of inhibitors. No lane-to-lane or run-to-run contamination was observed, and the system correctly identified the presence of mixtures. Taken together, the ANDE instrument, I-Chip consumable, FlexPlex chemistry (a 27-locus STR assay compatible with all widely used global loci, including the CODIS core 20 loci), and automated Expert System successfully processed and interpreted more than 1200 unique samples with over 99.99% concordant CODIS alleles. This extensive developmental validation data provides support for broad use of the system by agencies and accredited forensic laboratories in single-source suspect-evidence comparisons, local database searches, and DVI.  相似文献   

10.
As the result of the communist terror in Poland, during years 1944–1956 more than 50,000 people died. Their bodies were buried secretly, and most places are still unknown. The research presents the results of identification of people buried in one of many mass graves, which were found at the cemetery Pow?zki Military in Warsaw, Poland. Exhumation revealed the remains of eight people, among which seven were identified genetically. Well‐preserved molars were used for the study. Reference material was collected from the closest living relatives. In one case, an exhumation of victim's parents had to be performed. DNA from swabs was extracted with a PrepFiler® BTA Forensic DNA Extraction Kit and organic method. Autosomal, Y‐STR amplification, and mtDNA sequencing were performed. The biostatistical calculations resulted in LR values from 1608 to 928 × 1018. So far, remains of more than 50 victims were identified.  相似文献   

11.
Abstract: Forensic anthropologists routinely macerate human bone for the purposes of identity and trauma analysis, but the heat and chemical treatments used can destroy genetic evidence. As a follow‐up to a previous study on nuclear DNA recovery that used pig ribs, this study utilizes human skeletal remains treated with various bone maceration techniques for nuclear DNA amplification using the standard Combined DNA Index System (CODIS) markers. DNA was extracted from 18 samples of human lower leg bones subjected to nine chemical and heat maceration techniques. Genotyping was carried out using the AmpF?STR® COfiler® and AmpF?STR® Profiler Plus® ID kits. Results showed that heat treatments via microwave or Biz/Na2CO3 in sub‐boiling water efficiently macerate bone and produce amplifiable nuclear DNA for genetic analysis. Long‐term use of chemicals such as hydrogen peroxide is discouraged as it results in poor bone quality and has deleterious effects on DNA amplification.  相似文献   

12.
This study investigated whether routinely used forensic tests can distinguish 3‐day‐old or 2‐week‐old fly artifacts, produced after feeding on human blood, semen, or saliva, from the biological fluid. Hemastix®, Hemident?, and Hemascein? were unable to distinguish blood from artifacts. Hemastix® returned false positives from negative controls. ABAcard® Hematrace® and Hexagon OBTI could distinguish blood from 3‐day‐old artifacts, but not 2‐week‐old artifacts. Phadebas® and SALIgAE® were unable to distinguish saliva from artifacts. RSID?‐Saliva was able to distinguish saliva from 3‐day‐old artifacts, but not 2‐week‐old artifacts. Semen tests Seminal Acid Phosphatase, RSID?‐Semen, and ABAcard® p30 were all able to distinguish semen from 3‐day‐old artifacts, but not 2‐week‐old artifacts. The tests investigated cannot be relied upon to distinguish artifacts from biological fluids. However, if an artifact is identified by its morphology, a positive result may indicate which biological fluid the fly consumed, and this knowledge may prove useful for investigators searching for DNA.  相似文献   

13.
A form of physical vapor deposition, called the conformal‐evaporated‐film‐by‐rotation (CEFR) method, was optimized for the conformal deposition of columnar thin films (CTFs) on sebaceous fingermarks. Relying on the surface topology of the fingermark, the CTF development technique is different from traditional development techniques. After the optimization of the development conditions, the CTF development technique was found to be superior to traditional development methods on several nonporous substrates: the smooth side of Scotch® Multitask, Gorilla®, and Scotch® Duct tapes; clear and black soft plastics; stained and sealed walnut and cherry woods; partial bloody fingermarks on stainless steel; and discharged cartridge casings. It was equally as good as other development techniques on other substrates, but worse on a few. The optimization study is expected to assist in designing a mobile CEFR apparatus capable of on‐scene development of fingermarks.  相似文献   

14.
European forensic laboratories are replacing the STR multiplex kits with the new generation 16/17 STR kits. This study examines the influence of the new generation kits and the new Applied Biosystems 3500xL Genetic Analyzer on the designation of long D2S1338 and D19S433 off‐ladder alleles. Different allele calls were obtained using the new NGM? (Applied Biosystems) and PowerPlex® ESI? (Promega) kits compared with AmpF?STR® SGM Plus? kit (Applied Biosystems). Sequence analysis was used to determine accurate allele designation. The new multiplex kits and the 3500xL Genetic Analyzer improved accuracy of long allele designations. DNA databases worldwide include countless profiles obtained by previous kits. Discrepancies between the new and former technologies may cause failure to detect hits. Discordance is expected due to primer sequence differences between various kits. An additional discordance, occurring in long alleles, independent of primer sequence is reported in this study.  相似文献   

15.
Direct PCR has been used successfully in wildlife forensic DNA analysis from several types of biological samples using specialized, commercial direct PCR kits. This is attributed to the proprietary chemicals provided in the kits such as pre-PCR buffer and modified DNA polymerases. These reagents can be expensive, thereby limiting their widespread adoption in developing countries, where wildlife crimes are often encountered. We report on a study to evaluate the possibility of using low-cost direct PCR assay for degraded and processed wildlife sample analysis. Phire® and Q5® polymerases were used, due to their relatively low cost, for direct amplification of six aged and processed sample types (dried skin, 30-year old hair, muscle tissue, bone, trace blood mixed in vodka, and dried soft antler). The result indicated that Phire® Hot Start II DNA polymerase and Q5® DNA polymerase performed similarly to commercially available direct PCR kit. The low-cost amplification could efficiently identify species origin from all aged and processed samples. We observed a rate of more than 80% amplification success and high PCR product concentrations sufficient for further sequencing. The assay proved to be cost effective and robust; thus, we expect it to be adopted by wildlife forensic laboratories in developing countries.  相似文献   

16.
PowerPlex® Y23 is a novel kit for Y‐STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y‐STR analysis. This study examined PCR amplification from 1.2‐mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High‐quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories.  相似文献   

17.
In sexual assault cases DNA profiling of spermatozoa can be of critical importance. Most methods use differential extraction of the spermatozoa to separate it from the female component. Here we have compared two commercially available differential extraction methods, the QIAamp® DNA mini kit (Qiagen) and Differex™ with the DNA IQ® System (Promega). Simulated postcoital samples were prepared using buccal cells from a female donor and spermatozoa from three male donors. A dilution series ranging from neat semen to a 1:1500 dilution (semen:dH2O) was prepared and mixed with an equal volume of saliva from a female donor. Extraction efficiency was assessed using DNA concentration measured with NanoDrop 2000 and Quantifiler® Human DNA Quantification Kit and the profile count of full, partial and mixed DNA profiles generated using SGM Plus and PowerPlex® ESI 17. Statistical analysis was carried out using Randomisation in R, which is a robust model making no assumption of the distribution of data. Based on the amount of DNA extracted and the types of profiles no significant difference in the performance of the two extraction kits was seen. However, the processing time taken with the Differex™ System was about half than that of the QIAamp® DNA mini kit and involved fewer liquid transfers.  相似文献   

18.
The processing of skeletal material poses several challenges for forensic laboratories. Current methods can be laborious, time-consuming, require dedicated equipment, and are vulnerable to contamination. In this study, various sample mass (1 × 50 mg, 3 × 50 mg, and 1 × 150 mg chip(s)) and incubation times (2, 4, and 16 h) were tested using the PrepFiler® BTA™ Forensic DNA Extraction Kit to digest whole bone chips in lieu of powdering. The most effective method was then applied to bones and tooth fragments collected from contemporary human cadavers exposed to various environmental conditions using an automated platform. Over a third of the samples tested generated full DNA profiles without having to powder the bone/tooth fragment or further alter the manufacturer's protocol. However, for most samples resulting in incomplete STR profiles due to low amounts of DNA, slightly better results were achieved with powdered tissue. Overall, this work demonstrates the potential use of a faster, nonpowdering DNA extraction method for processing skeletal samples as an effective first-pass screening tool.  相似文献   

19.
Forensic evidence samples are routinely found as stains on various substrates, which may contain substances known to inhibit polymerase chain reaction (PCR). The goal of this study was to evaluate post‐Chelex®100 purification using powdered activated carbon (PAC). Mock crime scene DNA extracts were analyzed using quantitative PCR and short tandem repeat (STR) profiling to test the DNA recovery and inhibitor removal using PAC with those of the Amicon®Ultra 100K. For extracted bloodstains on soil and wood substrates, PAC and Amicon®Ultra 100K generated similar DNA yield and quality. Moreover, the two methods significantly decreased the concentration of humic substances and tannins compared to nonpurified extracts (< 0.001). In instances where extracts contained indigo dye (bloodstains on denim), Amicon®Ultra 100K performed better than PAC due to improved amplifiability. Efficient adsorption of humic substances and tannins, which are common inhibitors, indicates PAC's potential application in the purification of high‐template DNA extracts.  相似文献   

20.
Abstract: DNA amplification is a fundamental yet costly process used in DNA analysis. This study evaluated half‐reaction amplification (12.5, 12, and 13 uL) using the Promega Powerplex® 16 Kit with the hope of reducing sample analysis costs by half. A sensitivity study was completed, along with the testing of various blood stain samples including those with low (<0.40 ng) and high DNA concentrations (>3.0 ng), peak height imbalances, and allelic drop‐out. Also, 467 samples submitted to the MUFSC laboratory for testing were analyzed. Results indicate that half‐reaction amplification produced higher quality profiles than full‐reactions. Average peak heights increased by 85%, peak height imbalances improved, and drop‐out was eliminated in 75.8% of samples. Only eight of 467 case samples required re‐amplification, a success rate of 94% was observed, and the repeat rate decreased significantly. Finally, a DNA input of 0.25–1.0 ng is ideal for half‐reaction amplification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号