首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Abstract: Multiplex autosomal short tandem repeat (STR) genotyping enables researchers to obtain genetic information from ancient human samples. In this study, we tested newly developed AmpF?STR® MiniFiler? kit for autosomal STR analysis of ancient DNA (aDNA), using human femurs (n = 8) collected from medieval Korean tombs. After extracting aDNA from the bones, autosomal STR analyses were repeated for each sample using the AmpF?STR® MiniFiler? and Identifiler? kits. Whereas only 21.87% of larger‐sized loci profiles could be obtained with the Identifiler? kit, 75% of the same loci profiles were determined by MiniFiler? kit analysis. This very successful amplification of large‐sized STR markers from highly degraded aDNA suggests that the MiniFiler? kit could be a useful complement to conventional STR kit analysis of ancient samples.  相似文献   

2.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

3.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

4.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

5.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

6.
The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.  相似文献   

7.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

8.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

9.
It is proposed that a DNA stabilizing solution (DNA Genotek Inc.) designed to preserve DNA in saliva samples at room temperature can be extrapolated to the storage of swab heads. The aim of this study was to evaluate the effectiveness of the solution for the preservation of reference swabs (buccal) and trace samples (facial swabs). To this end, the solution was used during a twin-site DNA transfer project assessing background levels of carer DNA present in children. Tubes containing 400 μl of solution were used to store and transport swab heads. At the laboratory, samples were extracted using the QIAamp DNA Mini Kit (Qiagen), quantified using the Quantifiler Duo Kit and profiled using the AmpF?STR® SGM Plus® PCR Amplification Kit (both Applied Biosystems). Twenty-eight PCR cycles were applied to all samples. Thirty-four cycles or a longer electrophoresis injection time was applied to trace samples where necessary. All Reference swabs produced high quantities of DNA and full DNA profiles after 28 cycles. Profile morphology indicated good quality DNA with no degradation. Of the trace samples, sufficient profiles were achieved to study the transfer of carer DNA making the solution fit for continued use in this project. DNA stabilizing solution enables the storage and transportation of swabs without freezing. This is convenient, reduces transportation costs and enables instant analysis of samples upon arrival at the laboratory. This is a useful alternative for a multi-site research project as well as a reliable storage tool for use in remote areas.  相似文献   

10.
Abstract: The Quantifiler® Duo DNA Quantification kit enables simultaneous quantification of human DNA and human male DNA as well as detection of inhibitors of PCR in a single real-time PCR well. Pooled human male genomic DNA is used to generate standard curves for both human (ribonuclease P RNA component H1) and human male (sex determining region Y) specific targets. A shift in the cycle threshold (CT) values for the internal positive control monitors the presence of PCR inhibitors in a sample. The assay is human specific and exhibits a high dynamic range from 0.023 to 50 ng/μL. In addition, the multiplex assay can detect as little as 25 pg/μL of human male DNA in the presence of a 1000-fold excess of human female DNA. The multiplex assay provides assessment of the DNA extract and guidance for the selection of the appropriate AmpFℓSTR® Amplification Kit to obtain interpretable short tandem repeat profiles.  相似文献   

11.
Abstract: This paper reports the results of a commission to develop a field deployable rapid short tandem repeat (STR)‐based DNA profiling system to enable discrimination between tissues derived from a small number of individuals. Speed was achieved by truncation of sample preparation and field deployability by use of an Agilent 2100 BioanalyserTM. Human blood and tissues were stabbed with heated stainless steel wire and the resulting sample dehydrated with isopropanol prior to direct addition to a PCR. Choice of a polymerase tolerant of tissue residues and cycles of amplification appropriate for the amount of template expected yielded useful profiles with a custom‐designed quintuplex primer set suitable for use with the BioanalyserTM. Samples stored on wires remained amplifiable for months, allowing their transportation unrefrigerated from remote locations to a laboratory for analysis using AmpFlSTR® Profiler Plus® without further processing. The field system meets the requirements for discrimination of samples from small sets and retains access to full STR profiling when required.  相似文献   

12.
We describe the developmental validation study performed on the PowerPlex® ESX 16 (European Standard Extended 16) and the PowerPlex® ESX 17 Systems, part of a suite of four new DNA profiling kits developed by Promega in response to the ENFSI and EDNAP groups’ call for new STR multiplexes for Europe. The PowerPlex® ESX 16 System combines the 11 loci compatible with the UK National DNA Database, contained within the AmpFlSTR® SGM Plus® PCR Amplification Kit, with five additional loci: D2S441, D10S1248, D22S1045, D1S1656 and D12S391. The multiplex was designed to incorporate these five new loci as mini- and midi-STRs while maintaining the loci found in the AmpFlSTR® SGM Plus® kit as standard size. The PowerPlex® ESX 17 System amplifies the same loci as the PowerPlex® ESX 16 System, but with the addition of a primer pair for the SE33 locus. Tests were designed to address the developmental validation guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM), and those of the DNA Advisory Board (DAB). Samples processed include DNA mixtures, PCR reactions spiked with inhibitors, a sensitivity series, and 306 United Kingdom donor samples to determine concordance with data generated with the AmpFlSTR® SGM Plus® kit. Allele frequencies from 242 white Caucasian samples collected in the United Kingdom are also presented. The PowerPlex® ESX 16 and ESX 17 Systems are robust and sensitive tools, suitable for the analysis of forensic DNA samples. Full profiles were routinely observed with 62.5 pg of a fully heterozygous single source DNA template. In mixture analysis, a range of 52-95% of unique minor contributor alleles was observed at 19:1 mixture ratios where only 25 pg of the minor component was present. Improved sensitivity combined with the robustness afforded by smaller amplicons has substantially improved the quantity of information obtained from degraded samples, and the improved chemistry confers exceptional tolerance to high levels of laboratory prepared inhibitors.  相似文献   

13.
Disputes over the identity of a urine sample donor have been reported, and urine authentication by genetic profiling has helped resolved the cases. However, since genotyping of urine is not always required, many drug-testing laboratories may face sample storage issues. Several studies have investigated the use of FTA® cards as a convenient tool for keeping specimen at room temperature for extended periods of time. However, generating complete STR profile from some FTA®-deposited urine samples remains challenging due to low levels of genetic material content, necessitating amendments to the laboratory’s standard protocols. This work therefore aims to evaluate the effects of two DNA template preparation methods, both employing FTA® cards as the storage medium, on the success rates of STR profiling from urine. Specimen from a female volunteer, representing a particularly low-yield sample, was employed. Aliquots of 1 and 2 mL were used as the starting material to evaluate DNA template preparation using the FTA® manufacturer’s protocol for disc purification against elution of DNA from the FTA® using Prepfiler™ Forensic DNA Extraction Kit. AmpFSTR™ Identifiler™ Plus PCR Amplification Kit was used to amplify the STR markers, and the PCR products were analysed using Applied Biosystems™ 3500xL Genetic Analyzer. The DNA profile qualities were examined in terms of number of loci detected and peak height balance. Comparisons with the profiles obtained from DNA isolated using QIAamp® DNA Micro Kit from 1 and 2 mL of the same batch of urine were also made. The optimised protocol was then tested on urine samples from three male volunteers. The results showed that the purification of FTA® punches according to the manufacturer’s protocol enabled full DNA profiles to be obtained from both 1 and 2 mL of urine from all samples tested, including male samples. In contrast, no DNA profile could be generated from the DNA eluted with the Prepfiler™ kit. When compared with the more conventional solid-phase DNA extraction method, the profiles generated from the FTA® punches exhibited similar reproducibility and quality to those from the template isolated by the QIAamp® Kit. This work further demonstrated the feasibility of FTA® cards as a tool for specimen storage and DNA template preparation from small volumes of urine for authentication by STR profiling. Full STR profiles could be generated from sample from both sexes without modification of the PCR conditions or injection time.  相似文献   

14.
Calcified tissues, such as bone and tooth, and some other sample types, such as those containing adhesive, present a challenge to standard extraction protocols. We have developed a lysis reagent, BTA™ lysis buffer, which is designed for use with PrepFiler™ Kit reagents. The BTA™ lysis buffer disrupts calcified tissue matrices and achieves effective extraction of DNA from pulverized bone and tooth samples. In addition, the BTA™ lysis buffer mildly but efficiently extracts DNA from challenging substrates like tape, chewing gum, and cigarette butts and, as with bone and tooth, DNA from these lysates is purified using established PrepFiler™ reagent extraction protocols.We successfully extracted DNA from powdered human bone samples, chewed gum and smoked cigarettes using BTA™ lysis buffer. Extraction yields for bone, gum and cigarette samples tested were consistent and reproducible. This extraction method efficiently removed potential PCR inhibitors from all samples tested, and CT values for the internal PCR control of Quantifiler® Human DNA Quantification Kit were consistent and within the normal range. The DNA extracted from these samples also provided conclusive profiles that were free of PCR artifacts when amplified using the AmpF?STR® Identifiler® PCR Amplification Kit. The protocol is easily adapted for automation.  相似文献   

15.
Abstract:  The male‐specific Y‐chromosomal short tandem repeat (STR) is a useful tool in forensic casework. The Y haplotype comprised of 16 loci, which is amplified simultaneously by AmpFlSTR® YfilerTM PCR kit and provides strong exculpatory evidence in individual identification. We reported a rare Y‐STR profile with a null allele at the DYS448 locus and an off‐ladder allele at the DYS456 locus, when genotyping material from a vaginal swab in an alleged rape case. Sequence analysis revealed that the DYS448 null allele was a true type of null allele because of a total deletion of 11 upstream repeats and 9 bp of the N42 region, and there were numerous primer binding site mutations as well. The amplicon of the DYS456 locus was a small 92‐bp fragment that was off‐ladder, and sequencing analysis showed that there were only 10 repeats (AGAT)10. This Y chromosome haplotype that was comprised of two variations provided helpful evidence for personal identification.  相似文献   

16.
Since its introduction in 2002, the AmpF?STR® SEfiler™ kit has provided a highly discriminating DNA profiling option to German forensic laboratories by combining the widely used SGM Plus® Kit loci with the SE-33 locus required for the German DNA Database. Whilst proving successful on database samples, laboratories using the SEfiler™ kit have reported the need for chemistry better able to handle the ever-increasing number of casework samples.The new AmpF?STR® SEfiler Plus™ kit contains the same loci and primer sequences as the SEfiler™ kit but uses improved synthesis and purification processes to minimize the presence of dye-labeled artifacts. Other improvements include modified PCR cycling conditions for enhanced sensitivity and a new buffer formulation that improves performance with inhibited samples when compared to the original SEfiler™ kit.Validation studies demonstrating the effectiveness of the multiplex are presented with emphasis on the models of inhibition and casework samples.  相似文献   

17.
《Science & justice》2014,54(4):311-315
DNA left on a forensic sample is often prone to degradation, especially if left to the elements. To maximize the chance of retrieving the most information from such compromised DNA, an appropriate profiling scheme using the available technologies needs to be devised. In this study, a total of 62 cigarette ends collected under different conditions of environmental exposure were employed to test the effectiveness of three DNA amplification kits, namely the Applied Biosystems™ AmpFℓSTR® Identifiler®, Identifiler® Plus and MiniFiler™ PCR Amplification Kits, in the profiling of such compromised DNA. We demonstrated that Identifiler® Plus could substitute Identifiler® to improve the effectiveness of profiling for those inhibited cigarette samples. MiniFiler™, on the other hand, could supplement Identifiler®/Identifiler® Plus profiles and provide additional genetic information to enhance the evidential value of the samples, especially for those that have suffered from DNA degradation to a greater extent. The findings in this work allowed us to propose a DNA profiling strategy as follow: 1) samples yielding complete Identifiler®/Identifiler® Plus profiles require no further testing with MiniFiler™; 2) samples yielding partial single-source profiles to be tested with MiniFiler™ to add genetic information; 3) samples yielding no results are unlikely to yield any results with MiniFiler™.  相似文献   

18.
When using non-FTA cards in commercial multiplex STR kits for direct PCR, pretreatment steps with specific buffers are recommended. Here, we designed a rapid direct PCR method utilizing a non-FTA card, Oral Cell Sampling Kit, by omitting the pretreatment step involving Prep-n-Go™ Buffer, and it showed compatibility with the GlobalFiler™ Express PCR Amplification Kit, GlobalFiler™ PCR Amplification Kit, and PowerPlex® Fusion system. To optimize the PCR conditions, we tested the method with different final PCR volumes and cycles. Finally, we conducted a performance test using 50 Korean buccal samples and confirmed the high performance of the method, detecting more than 90% of the samples with full profiles when using GlobalFiler™ PCR Amplification Kit and PowerPlex® Fusion system at 29 cycles in a 10 μL final PCR volume. Thus, we report a simple direct PCR set-up to analyze reference samples collected using a non-FTA card manufactured in Korea.  相似文献   

19.
We have implemented and validated automated methods for DNA extraction and PCR setup developed for a Tecan Freedom EVO® liquid handler mounted with a Te-MagS™ magnetic separation device. The DNA was extracted using the Qiagen MagAttract® DNA Mini M48 kit. The DNA was amplified using AmpF?STR® Identifiler®, Y-filer® (Applied Biosystems), GenePrint® FFFL and PowerPlex® Y (Promega). The methods were validated for fresh whole blood and blood from deceased according to EN/ISO 17025.  相似文献   

20.
Abstract: Three sampled populations of unrelated males—African American, Caucasian, and Hispanic, all from Texas—were typed for 16 Y short tandem repeat (STR) markers using the AmpFlSTR® YfilerTM kit. These samples also were typed previously for the 13 core CODIS autosomal STR loci. Most of the 16 marker haplotypes (2478 out of 2551 distinct haplotypes) were observed only once in the data sets. Haplotype diversities were 99.88%, 99.89%, and 99.87% for the African American, Caucasian, and Hispanic sample populations, respectively. FST values were very small when a haplotype comprised 10–16 markers. This suggests that inclusion of substructure correction is not required. However, haplotypes consisting of fewer loci may require the inclusion of FST corrections. The testing of independence of autosomal and Y STRs supports the proposition that the frequencies of autosomal and Y STR profiles can be combined using the product rule.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号