首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Although poaching is a common wildlife crime, the high and prohibitive cost of specialised animal testing means that many cases are left un-investigated. We previously described a novel approach to wildlife crime investigation that looked at the identification of human DNA on poached animal remains (Tobe, Govan and Welch, 2011). Human DNA was successfully isolated and amplified from simulated poaching incidents, however a low template protocol was required which made this method unsuitable for use in many laboratories. We now report on an optimised recovery and amplification protocol which removes the need for low template analysis.Samples from 10 deer (40 samples total — one from each leg) analysed in the original study were re-analysed in the current study with an additional 11 deer samples. Four samples analysed using Chelex did not show any results and a new method was devised whereby the available DNA was concentrated. By combining the DNA extracts from all tapings of the same deer remains followed by concentration, the recovered quantity of human DNA was found to be 29.5 pg ± 43.2 pg, 31 × greater than the previous study. The use of the Investigator Decaplex SE (QIAGEN) STR kit provided better results in the form of more complete profiles than did the AmpF?STR® SGM Plus® kit at 30 cycles (Applied Biosystems). Re-analysis of the samples from the initial study using the new, optimised protocol resulted in an average increase of 18% of recovered alleles. Over 17 samples, 71% of the samples analysed using the optimised protocol showed sufficient amplification for comparison to a reference profile and gave match probabilities ranging from 7.7690 × 10? 05 to 2.2706 × 10? 14.The removal of low template analysis means this optimised method provides evidence of high probative value and is suitable for immediate use in forensic laboratories. All methods and techniques used are standard and are compatible with current SOPs. As no high cost non-human DNA analysis is required the overall process is no more expensive than the investigation of other volume crime samples. The technique is suitable for immediate use in poaching incidents.  相似文献   

2.
This work evaluates cocaine purity and the concentration ranges of adulterants and inorganic constituents for 31 street cocaine samples seized in two different regions of Brazil from July 2008 to May 2010. Cocaine and adulterants, such as caffeine, lidocaine and benzocaine, were quantified by Gas chromatography–mass spectrometry (GC–MS), and the inorganic constituents were determined by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) and ion chromatography (IC). The cocaine concentrations in the samples seized in the Amazonas state (AM samples) ranged from 154 to 978 mg g? 1, and these samples did not contain any of the adulterants studied. The cocaine concentrations in the samples seized in the Minas Gerais state (MG samples) ranged from 63.9 to 753 mg g? 1. Caffeine was the main adulterant found in 76% of the MG samples, ranging in concentration from 5.5 to 645.3 mg g? 1. Lidocaine was found in 66.7% of the MG samples, with concentrations ranging from 16.3 to 576.7 mg g? 1. Benzocaine was found in only one MG sample, at a concentration of 84.8 mg g? 1. Fourteen elements were identified by ICP-OES, and a wide variation was observed in the concentrations of Ca, Mg, Na, P, Al, Fe, Mn and Zn. Pearson Product–moment Correlations between the analytes allowed the constituents to be associated with the chemicals used in the manufacturing of cocaine and with some common diluents. The study of the purity of cocaine and the presence and concentration of adulterants and inorganic constituents is important because the latter can have deleterious effects on health.  相似文献   

3.
《Science & justice》2020,60(6):538-546
The chemical profiling of bloodstains is essential to link the suspect with the crime. The current study proposed a proof-of-concept methodology for the investigation of bloodstains by utilizing advanced ATR-FTIR spectroscopy coupled with new generation chemometric methods. Current study provides encouraging data to allow discrimination between human and animal blood though with small sample size. In this study, different models for the age estimation of human bloodstains are developed from the trained data sets of 1–175 days old bloodstains. The models such as curve estimation (CE), multiple linear regression (MLR), and partial least squares regressions (PLSR) are developed to determine the best prediction model for aged human bloodstains. The obtained results on the dating of bloodstains are very encouraging and also tested for unknown samples. The maximum dating errors are observed in the curve estimation models whereas, the other models MLR, PLSR show excellent age estimation of unknown bloodstains. These models represent an error of ~3 ± 1 days and ~4 ± 1 days in actual and estimated date, respectively, which is lowest ever reported so far. The present methodology is expected to provide a valuable insight into forensic society and hence, to the law enforcement community. The present methodology can further be explored for an ideal model by including all other external variables/factors and for more longer aging time.  相似文献   

4.
《Science & justice》2014,54(6):421-426
The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC–MS (UHPLC–MS/MS) method and an SPME–GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A — direct injection of 10 μL in UHPLC–MS/MS in positive electrospray ionisation (ESI) mode and B — sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port.The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC–MS/MS and 0.5 ng/mL in SPME–GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC–MS/MS the LLOD was 20 ng/mL.Both methods were applied to 70 samples coming from roadside tests. By SPME–GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL.  相似文献   

5.
In post-mortem work, blood is a potential source of external contamination of hair. The present study was carried out to investigate the amount of drug absorbed into hair which has been contaminated with blood containing either cocaine or BE. Solutions were prepared containing 0.05, 0.1, 0.2, 0.5 and 3.0 μg/mL of either cocaine or BE in human blood. Samples of approximately 3.2 g of drug-free hair were contaminated by soaking in the blood solutions for 5 min. They were then removed and left at room temperature. Approximately 0.5 g of hair was collected from each of the blood soaked hair samples at 6 h, 1, 2, 4 and 7 days after contamination. As each hair sample was collected it was shampoo-washed to prevent further drug absorption. Hair samples were analysed in triplicate using a fully validated method described previously. EME and cocaethylene were also measured in order to find out if cocaine or BE was breaking down to these compounds. Both cocaine and BE were absorbed into hair in significant concentrations when the concentration in the blood was 0.5 μg/mL or greater; cocaine was more readily absorbed than BE. Cocaine broke down to EME (<LOQ) at 0.5 μg/mL and to EME (>LOQ) and BE (<LOQ) at 3.0 μg/mL. When the blood concentration of cocaine was 0.5 μg/mL or less, there was no evidence of it breaking down to form BE. From the samples soaked in blood containing BE, there was no evidence of the BE breaking down. The absorption of drug into hair did not increase as the contamination period increased from 6 h to 7 days.  相似文献   

6.
A rapid and sensitive determination of cannabinoids in urine is important in many fields, from workplace drug testing over toxicology to the fight against doping. The detection of cannabis abuse is normally based on the quantification of the most important metabolite 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCA) in urine. In most fields THCA needs to be present at a concentration of exceeding 15 ng/mL before a positive result can be reported.The method described in this paper, combines a 4 min GC–MS/MS method with a fast sample preparation procedure using microwave assisted derivatisation in order to complete the quantification of THCA in urine in 30 min, using only 1 mL of urine.The method is selective, linear over the range 5–100 ng/mL and shows excellent precision and trueness and hence, the estimated measurement uncertainty at the threshold level is small. The method also complies with applicable criteria for mass spectrometry and chromatography. Therefore the method can be used for rapid screening and confirmatory purposes.  相似文献   

7.
Amphetamine and related derivatives are widely abused central- and psychostimulants. Detection of certain derivatives, such as methcathinone, by commonly available immunoassay screening techniques is insufficient. Multi-analyte confirmations for amphetamine type stimulants are therefore required, but traditional gas chromatography–mass spectrometry methods necessitate lengthy analytical procedures with prolonged sample turn-around times. A validated rapid GC–MS assay for urinary confirmation of amphetamine, methamphetamine, methcathinone, ephedrine, norephedrine, methylenedioxyamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine and N-methyl-1-(3,4 methylenedioxyphenyl)-2-butanamine is reported. The method entailed in situ derivatization of urine specimens by extractive acylation with pentafluoropropionic anhydride, followed by rapid chromatography on a microbore capillary column. Analytes were separated in less than 3 min and quantified simultaneously by selected-ion monitoring using stable isotope substituted internal standards. The total instrument cycle-time was 6 min per sample. The limits of detection were between 1.5 ng/mL and 6.25 ng/mL for the various analytes. Intermediate precision and accuracy were in the range of 6.3–13.8% and 90.5–107.3% for the respective analytes at the lower limit of quantitation, and between 5.8–12.6% and 95.4–103.1% for the high control. Long-term storage of methcathinone positive specimens at ?20 °C proved insufficient stability of this analyte. The proposed assay is precise and accurate for confirmation of amphetamine and derivatives in urine. The complementary approach of extractive-derivatization and fast GC–MS analysis is especially applicable in routine clinical settings where reduced sample turn-around times are required. Further investigation of cathinone as a possible metabolite of methcathinone is warranted, based on results from analyzed authentic urine samples.  相似文献   

8.
A gas chromatography–mass spectrometry (GC–MS) method was developed and validated for the simultaneous qualification and quantification of methamphetamine (MA), amphetamine (AP), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-amphetamine (MDA), ketamine (KET) and norketamine (NKT) in fingernails. Fingernail samples (20 mg) were washed with distilled water and methanol, digested with 1.0 M sodium hydroxide at 95 °C for 30 min, and then extracted with ethyl acetate. Extract solutions were evaporated to dryness, derivatized using heptafluorobutyric anhydride (HFBA) at 60 °C for 30 min, and analyzed by GC–MS. The linear ranges were 0.1–20.0 ng/mg for AP, MDMA and NKT, 0.2–20.0 ng/mg for MA and MDA, and 0.4–20.0 ng/mg for KET, with the coefficients of determination (r2  0.9989). The intra- and inter-day precisions were within 7.1% and 10.6%, respectively. The intra- and inter-day accuracies were ?10.9% to 0.8% and ?4.3% to 4.5%, respectively. The limits of detections (LODs) and the limits of quantifications (LOQs) for each analyte were lower than 0.094 ng/mg and 0.314 ng/mg, respectively. The recoveries were in the range of 72.3–94.9%. The average fingernail growth rates of two subjects for three years and six subjects for two months were 3.12 mm/month and 3.16 mm/month, respectively. The method proved to be suitable also for the simultaneous detection and quantification of MA, MDMA, KET and their metabolites in fingernails.  相似文献   

9.
A continual challenge in the field of forensic DNA analysis is the amplification and interpretation of degraded and low-copy number (LCN) DNA obtained from amounts of limited biological evidence. It has been well established that DNA profiles obtained from the amplification of low quality, degraded, and/or LCN DNA samples are often of limited value due to the frequent occurrence of preferential amplification during polymerase chain reaction (PCR). The by-products of preferential PCR amplification are often observed as inter- and intra-locus peak imbalance, allelic dropout, and/or locus dropout. These are all artifacts that are identified during the interpretation phase of analysis rather than by improving the quality of the DNA present. While it is theoretically possible to obtain a complete DNA profile from a single cell, in reality, profiles obtained from suboptimal amounts of DNA are difficult to interpret and frequently inconsistent when replicated. Inspired by advances in next-generation sequencing techniques, we propose a methodology for simultaneously normalizing the abundance of PCR products across all short tandem repeat (STR) loci using the DNA exonuclease, duplex-specific nuclease (DSN). DSN is an enzyme isolated from the hepatopancreas of Red King (Kamchatka) crab that possesses a strong affinity for digesting double stranded DNA (dsDNA) and has limited activity toward single stranded DNA (ssDNA). Degraded DNA known to display peak imbalance and allele dropout was amplified using AmpFlSTR® Identifiler® Plus for 28 cycles. Following amplification, samples were denatured at 99.9 °C for 5 min and incubated with one unit of DSN at 62 °C in a 28 μl volume for 1 min. Nuclease activity was terminated through the addition of equal volume of 10 mM EDTA and 95 °C incubation for 2 min. Following DSN treatment, 21 of 30 alleles within the known profile exhibited some improvement in peak height balance. The findings obtained support the potential use of DSN treatment as a method for normalizing STR profiles and improving the quality of data from degraded and low quantity DNA samples.  相似文献   

10.
IntroductionIn this paper, the authors presented a case of acrylamide poisoning in a middle-aged woman who had underwent unsuccessful cosmetic surgery six years earlier. The victim was told that the product that had been injected into her face was Restylane®, which mainly contained sodium hyaluronate and was the first and only Food and Drug Administration (FDA)-approved dermal filler for lip enhancement in the USA for more than 20 years. Widespread facial infections occurred several years post-injection; finally, the victim had to undergo removal surgery. Acrylamide poisoning was strongly suspected based on the victim's clinical manifestation. The product that had been injected into the victim's face was probably polyacrylamide hydrogel-based product, which had been prohibited by the State Food and Drug Administration (SFDA) in China in 2006. To confirm this suspicion, a systematical method was established to differentiate varieties of cosmetic surgery products and identify residential acrylamide.MethodsThe removed objects, original products and a certified reference sample of Restylane® were collected for examination. A direct microscopic examination was applied as a rapid screening method. Fourier transform infrared (FTIR) microspectroscopy analysis was subsequently performed to distinguish the main components from each sample. Automated solid phase extraction, ultra high performance liquid chromatography (SPE UHPLC) analysis was ultimately utilised and optimised to detect the residual acrylamide. Chromatographic separation was achieved on an ACQUITY UHPLC HSS T3 column. The mobile phase consisted of 0.01% aqueous formic acid solution and acetonitrile. The tunable UV (TUV) detection wavelength was at 202 nm.ResultsThe microscopic examination indicated that different samples had different morphological characteristics, depending on their main components. The FTIR spectrum showed that different polymers could be distinguished according to the CO stretching vibration (1655 cm? 1), NH bending vibration (1540 cm? 1) and CO stretching vibration (1078 and 1045 cm? 1). The UHPLC results demonstrated that the calibration curve was linear in the range of 0.5–20.0 μg/mL, with a correlation coefficient of 0.999. The average recoveries of the method were 99–107% with an RSD of 1.6–6.3%. The detection limit was 0.1 μg/mL (S/N = 3). The analytical time was 6 min per sample. Acrylamide was detected in the allegedly Restylane® injection.ConclusionsThis systematical method provides a rapid, accurate and sensitive determination of polyacrylamide and residual acrylamide. The microscopic and FTIR spectroscopic examinations help to verify the existence of polyacrylamide quickly and easily. The optimised SPE UHPLC-TUV method offers a simpler and more sensitive approach to confirm the amount of acrylamide, comparing to the methods in the literature.  相似文献   

11.
Allele frequency distributions for 24 short tandem repeat (STR) loci were determined using the PowerPlexR Fusion System (Promega) in 407 Japanese samples. The most informative locus among the 22 STR loci, excluding Amelogenin and DYS391, was Penta E (power of discrimination (PD) = 0.98), while the least informative was TPOX(PD = 0.831). The 22 loci combined matching probability (MP) was calculated to be 4.13 × 10−26. These parameters indicated the usefulness of this 24 STR analysis in forensic personal identification and parentage testing among Japanese population.  相似文献   

12.
Many scientists of varying clinical backgrounds have described the phenomenon of spermaturia in animals, adolescents as well as fertile and infertile men. Nevertheless, research for an expert opinion on a law case in the field of forensic medicine revealed a lack of valid information about the longevity of spermatozoa in post-ejaculatory urine (PEU) of fertile men.Our goal was to measure the appearance of vivid sperm in PEU while considering the factor of time in order to predict a realistic interval, in which positive sperm findings might occur. Therefore ten healthy, young men donated their sperm for fertility analysis and a urine sample prior to and after ejaculation. The time intervals between ejaculation and the first micturition were preset ranging between 30 min and maximal 11 h. Each ejaculate underwent a semen analysis. The pre- and post-ejaculatory urine samples were screened for the presence of viable and motile spermatozoa. Semen parameters were determined and related to the sperm findings in the precipitate of the urine samples. The amount, the viability and motility status of the detected spermatozoa were recorded after each preset time interval.The results showed that none of the 10 participants had sperm in their urine samples prior to ejaculation. The average sperm concentration was 50.1 ± 25.8 million/ml. After a time span of 30 min 59.5% of the first fractions of PEU samples were sperm positive, after 2 and 4 h still 70%, and after 5 h sperm were no longer detected. The last motile spermatozoa could be found after 4.5 h. It seems that remaining sperm in the urethra are washed out with the first micturition in the majority of fertile men, however, the conclusion as to whether sperm findings >5 h after ejaculation are improbable needs to be confirmed by further investigations.  相似文献   

13.
For nearly 30 years, the methods utilized in illicit cocaine hydrochloride production have remained relatively consistent. Cocaine hydrochloride is typically produced one kilogram at a time. As a result, each individual kilogram is unique and distinct from other kilograms in any particular seizure based on the total alkaloid profile, occluded solvent profile, and isotopic signature. Additionally, multi-kilogram cocaine seizures are often comprised of cocaine from several different coca growing regions. There has been a documented shift in this type of processing based on the recent analysis of a large cocaine seizure in the Eastern Pacific. Signature analyses of samples from 21 kg randomly selected from a 517 kg seizure were virtually identical. Triplicate analyses of each sample via gas chromatography with flame ionization detection, static headspace gas chromatography mass spectrometry, and isotope ratio mass spectrometry were completed. An initial outlier evaluation of the data and an in-depth univariate analysis indicated there was no statistically significant difference among the 21 samples at the 95% confidence interval. Principal components analysis did reveal consistent minor deviations between the samples and known authentic data from the Nariño coca growing region of Colombia. These deviations were only observed on the latter principal components and could be explained by differences in solvent selection during cocaine hydrochloride processing. Chemical analyses in addition to a thorough statistical evaluation suggest a shift in the traditional small-batch method of cocaine processing to a multi-kilogram, high throughput approach.  相似文献   

14.
Urea nitrate (uronium nitrate, UN) is an improvised explosive that looks very much like sugar and is easily made from accessible starting materials, urea and nitric acid. During the last decade it has been frequently used by terrorists in the Israeli arena and in other countries as well. It is difficult to identify urea nitrate in post-explosion debris, since only a very small fraction survives the blast. Also, in the presence of water, it readily decomposes to its original components, urea and nitric acid, two ubiquitous substances with relatively low evidential value. By further modifying McCord's recent version of Clark's method for the detection of minute amounts of urea, we were able to identify with high degree of certainty traces of uronium ion, the main characteristic factor of urea nitrate, in post-blast residues by GC/MS. The analytical process is based on the initial formation of xanthenyl urea by the reaction of uronium cation with xanthydrol, followed by reaction with alcohol to form xanthylurethane, which is readily identified by GC/MS. The reaction mechanism was corroborated by the use of labeled 15N-urea. By applying the technique to residues collected from scenes of controlled firing experiments, 4 out of 16 samples showed the presence of uronium cation as indicated by the formation of the corresponding xanthylurethane. Potential interferences such as urea and ammonium nitrate did not respond under standard conditions. However, under strongly acidic conditions (pH < 2), urea is converted into uronium ion, which is a nuisance, since it behaves as an authentic uronium cation. Such conditions, however, do not prevail at common crime scenes.  相似文献   

15.
Elderly defendants (age 65+) and defendants with dementia adjudicated incompetent to stand trial and hospitalized for restoration to competence (RTC) often present unique challenges to clinicians charged with their restoration. In this study, we attempted to better identify predictors of successful RTC by building upon previous research correlating increased age with decreased likelihood of RTC. We identified elderly non-demented defendants (n = 31) and defendants diagnosed with dementia (n = 47) from a state database of 1380 individuals hospitalized for competence restoration from 1988–2004. Using regression analysis and correcting for demographic variables and common admission psychiatric diagnoses, we studied the relationship of age at hospital admission and dementia diagnosis on the likelihood of successful RTC. Both advanced age and dementia diagnosis were associated with decreased RTC. After correcting for dementia diagnosis, increased age retained its negative correlation with restoration success. Both elderly non-demented defendants and defendants diagnosed with dementia were significantly less likely to be restored to competence than all other RTC admissions (n = 1302). However, a substantial percentage of both demented and elderly non-demented defendants were successfully restored to competence, potentially justifying restoration attempts for both of these groups of defendants.  相似文献   

16.
PurposeTo construct an empirically rigorous typology of multiple homicide offenders (MHOs).MethodThe current study conducted latent class analysis of the official records of 160 MHOs sampled from eight states to evaluate their criminal careers.ResultsA 3-class solution best fit the data (?2LL = ?1123.61, Bayesian Information Criterion (BIC) = 2648.15, df = 81, L2 = 1179.77). Class 1 (n = 64, class assignment probability = .999) was the low-offending group marked by little criminal record and delayed arrest onset. Class 2 (n = 51, class assignment probability = .957) was the severe group that represents the most violent and habitual criminals. Class 3 (n = 45, class assignment probability = .959) was the moderate group whose offending careers were similar to Class 2.ConclusionA sustained criminal career with involvement in versatile forms of crime was observed for two of three classes of MHOs. Linkages to extant typologies and recommendations for additional research that incorporates clinical constructs are proffered.  相似文献   

17.
BackgroundOne of the most commonly used method for dental age assessment is the method reported by Demirjian and coworkers in 1973. It was later modified by Willems and coworkers whereby they &ldquo;performed a weighted ANOVA&rdquo; in order to adapt the scoring system.AimTo evaluate the applicability of Demirjian and Willems methods for dental age estimation for Malaysian children and to correlate the accuracy of the findings with the chronology of tooth development of premolars and second molars.Materials and methodsA total of 991 dental panoramic radiographs of 5–15-year-old Malaysian children were included in the study. The mean Demirjian and Willems estimated ages were compared to the mean chronological age.ResultsThe mean chronological age of the sample was 10.1 ± 2.8 and 9.9 ± 3.0 years for males and females respectively. Using the Demirjian method, the mean estimated dental age was 10.8 ± 2.9 years for males and 10.5 ± 2.9 years for females. For Willems method, the mean estimated age was 10.3 ± 2.8 years males and 10.0 ± 3.0 years respectively.ConclusionsWillems method was more applicable for estimating dental age for Malaysian children. Overestimation in Demirjian method could be due to advanced development of second bicuspids and molars.  相似文献   

18.
Soil analysis is a valuable resource in forensic investigation. Classical forensic soil analysis involves examination of its physical characteristics and chemical composition, such as soil type, colour, particle size, shape, pH, elemental, mineral and organic content. However the limited variability of these parameters is not always allowing adequate discrimination between soil samples. As soil supports extreme diversity of microorganisms and eukaryotic communities, microbiological approaches have been proposed. Several molecular approaches for microbial DNA profiling are available; however there is a lack of published data of implementation of the next generation sequencing (NGS) approaches for forensic soil analysis.The aim of the current study was elaboration of criteria for soil metagenome data management and database searching. We used our previously sequenced collection of 11 samples collected from different environments (forests, fields, grasslands, urban park) with different flora. The single sample collection includes 9 soil samples per one sampling area (30 m × 30 m) spaced by 15 m. In the current study we concentrated mainly on 18S rRNA gene V2-V3 region for fungi however SSU rRNA region for arbuscular mycorrhizal (AMF) fungi and V2-V3 hypervariable region of 16S rRNA gene for bacterial communities were taken into account. The sequencing was performed by Roche/454 platform. For data analysis OTU based approach on mothur software and NCBI BLASTN search were used. NCBI BLASTN analysis revealed altogether 2983 AMF matches and 8997 18S matches as well as 25477 OTUs (16S) were determined. Several data filtration approaches were used for data management. We found that 18S marker results could be used to create and run a filtered database that is computationally much more efficient and flexible. Our results have broad impact; however more samples have to be analysed, additional studies performed and cooperation between soil scientists and forensic scientists is required to be able to implement these novel techniques into the routine forensic practice.  相似文献   

19.
Human cremation is a common funeral practice all over the world and will presumably become an even more popular choice for interment in the future. Mainly for purposes of identification, there is presently a growing need to perform trace analyses such as DNA or stable isotope analyses on human remains after cremation in order to clarify pending questions in civil or criminal court cases. The aim of this study was to experimentally test the potential and limitations of DNA and stable isotope analyses when conducted on cremated remains.For this purpose, tibiae from modern cattle were experimentally cremated by incinerating the bones in increments of 100 °C until a maximum of 1000 °C was reached. In addition, cremated human remains were collected from a modern crematory. The samples were investigated to determine level of DNA preservation and stable isotope values (C and N in collagen, C and O in the structural carbonate, and Sr in apatite). Furthermore, we assessed the integrity of microstructural organization, appearance under UV-light, collagen content, as well as the mineral and crystalline organization. This was conducted in order to provide a general background with which to explain observed changes in the trace analyses data sets. The goal is to develop an efficacious screening method for determining at which degree of burning bone still retains its original biological signals. We found that stable isotope analysis of the tested light elements in bone is only possible up to a heat exposure of 300 °C while the isotopic signal from strontium remains unaltered even in bones exposed to very high temperatures. DNA-analyses seem theoretically possible up to a heat exposure of 600 °C but can not be advised in every case because of the increased risk of contamination. While the macroscopic colour and UV-fluorescence of cremated bone give hints to temperature exposure of the bone's outer surface, its histological appearance can be used as a reliable indicator for the assessment of the overall degree of burning.  相似文献   

20.
There is limited published data to aid interpretation of analytical findings from hair analysis. The aim of the study was to collate 6-monoacetylmorphine (6-AM) and morphine concentrations in head and pubic hair from heroin users and to propose reference ranges and relate these to the amount of heroin used. The ratio of morphine-to-6-AM was also investigated. A total of 82 head hair samples divided into 173 segments of various lengths and 15 pubic hair samples were collected at postmortem from heroin users. The hair was analysed using a previously published method. A statistical evaluation demonstrated that in head hair, the lower, middle and upper concentration ranges of 6-AM were 0.1–0.9, 0.9–12.5 and 12.5–154.1 ng/mg and those of morphine were 0.1–0.8, 0.8–6.0 and 6.0–36.3 ng/mg. In pubic hair, the lower, middle and upper concentration ranges of 6-AM were 0.2–0.5, 0.5–2.3 and 2.3–18.2 ng/mg and those of morphine were 0.2–0.4, 0.4–2.4 and 2.4–13.3 ng/mg. The morphine-to-6-AM ratio showed a large variation. The ratio tended to decrease from proximal to distal segments. The statistical results suggest low, middle and high concentration ranges which we propose can be used for estimating the amount of heroin consumed into corresponding low or occasional, regular or habitual and heavy or excessive drug use. The ratio of morphine-to-6-AM showed great variation and did not support the proposal that a ratio less than 0.77 is needed to prove ingestion of heroin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号