首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and sensitive LC/MS method was developed for the simultaneous analysis of N,N-dimethylamphetamine (DMA), N,N-dimethylamphetamine N-oxide (DMANO), methylamphetamine (MA) and amphetamine (A) in urine samples. Employing an Alltech C18 column for solid phase extraction followed by LC/MS analysis using an Alltech Platinum EPS C18 column with a mixture of ammonium formate (0.01 M, pH 3) and acetonitrile (77:23, v/v) as mobile phase at a flow rate of 0.2 mL/min, simultaneous identification and quantitation of A, MA, DMA and DMANO in urine can be achieved using a 5-min chromatographic run. The calibration ranges were 0.10-3.0 micro g/mL for DMANO, 0.05-3.0 micro g/mL for DMA and 0.05-5.0 micro g/mL for both MA and A. The intra-, inter-day precision and accuracy for all analytes, spiked at three different concentrations in quality control samples, were in the ranges of 1.7-8.6, 4.1-10.0, -11.6 to 12.9%, respectively. The newly developed method was applied to the analysis of urine samples obtained from 118 suspected MA/DMA abusers, with the presence of MA confirmed in their urine samples under the drug-use surveillance program. Of these 118 samples, 43 were found to contain DMANO and 11 with both DMANO and DMA.  相似文献   

2.
The stereoselective analysis of selegiline metabolites in human urine and plasma by gas chromatography using the chiral column with the non-chiral reagent was investigated for the differentiation of selegiline therapy from the methamphetamine (MA) abuse. This method gave clear separations of MA and amphetamine (AM) isomers without any artifactual optical-opposite peaks due to the reagent. After the administration of selegiline tablets, desmethylselegiline (DMS), MA and AM were observed as (−)-isomers in the urine and plasma. Within the first 48 h after dosing, approximately 40% of selegiline administered was excreted in urine as these three metabolites. The parent drug, selegiline, was not detected in any urine or plasma samples. On the other hand, MA and AM were observed only as (+)-isomers in the urine of MA abusers. For the distinction of selegiline users from street MA abusers in urinalysis, (−)-DMS, a specific metabolite of selegiline, was not a suitable marker. (−)-DMS rapidly disappeared from urine and was excreted only 1% of the given dose. By the moment analysis with the trapezoidal integration, the mean residence times of (−)-DMS in plasma and urine were 2.7 and 3.8 h, respectively, which were 5–20 times shorter than those of (−)-MA or (−)-AM. The values of AM/MA in the urine increased from 0.24 to 0.67 (r=0.857) along with time after the selegiline administration. This ratio was not a sufficient marker to differentiate selegiline users from MA abusers, although the values of AM/MA in 74% of MA abusers were less than 0.24. The present GC technique improved the chiral analyses of MA and AM. This chiral analysis is the most useful technique to avoid the misinterpretation in the discrimination between clinical selegiline therapy and illicit MA use.  相似文献   

3.
The long-term stability of drugs and metabolites of forensic interest in urine, and preventive measures against their decomposition have been investigated, with special attention to filtration sterilization. An aseptic urine collection kit, which was recently developed based on filtration sterilization, was utilized for the aseptic collection and storage of urine samples. For evaluating preservation measures, methamphetamine (MA), amphetamine (AP), nitrazepam (NZ), estazolam (EZ), 7-aminoflunitrazepam (7AF), cocaine (COC), and 6-acetylmorphine (6AM) were spiked into urine at 500 ng/mL each, and were monitored for 6 months at 25, 4, and -20 degrees C, after the addition of NaN(3) and/or filtration sterilization using the aseptic collection kit. In severely contaminated urine with bacteria, there were significant losses of 7AF and NZ, and slight decomposition of MA and AP at 25 degrees C. However, such degradation was successfully suppressed by the use of the kit, though the use of the kit and NaN(3) were preferred for 7AF. The kit was also effective in preventing the hydrolyses of COC and 6AM, while it was suggested that the common preservative NaN(3) can accelerate the hydrolysis of such ester-type drugs and metabolites.  相似文献   

4.
Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine.  相似文献   

5.
度冷丁滥用者尿中原体及其代谢产物的分析研究   总被引:2,自引:0,他引:2  
本研究利用GC/MS(EI.PCI)技术,在度冷丁滥用者尿中确认了6种代谢产物。并建立了GC/FID分析度冷丁及其代谢产物的方法。方法线性范围为0.1~20μg/ml,变异系数小于10%,最小检出量为50ng/ml,适用于度冷丁成瘾者尿中含量的测定。  相似文献   

6.
We encountered three methamphetamine (MA) body packers presenting simultaneously, one of whom died. Three Nigerian men (39, 35, and 37 years old) who attempted to smuggle were found to contain 35 (498 g), 21 (292 g), and 5 packages (73 g) of methamphetamine hydrochloride (MA-HCl) in their stomachs, respectively. Packages were wrapped with plastic film and Scotch tape. The 39-year-old man died with acute poisoning from c. 20 g of MA-HCl that had leaked from the packages into the stomach. His plasma MA concentration was 8.6 microg/mL when he was hospitalized (17 h before his death). Autopsy findings showed extreme pulmonary congestion and edema as well as moderate hepatic edema and several petechiae. Quantitative analysis was performed by gas chromatography/mass spectrometry. Extremely high concentrations of MA and its metabolite amphetamine (AP) were found in cardiac blood (63.5 microg/mL and 1.2 microg/mL), urine (4,518 microg/mL and 72.4 microg/mL), gastric contents (8,490 microg/mL and 16.9 microg/mL), and in all other autopsy samples. These high concentrations confirmed that the cause of death was acute MA poisoning. Furthermore, impurity-profiling analysis of the seized MA revealed that the MA smuggled by the three suspects originated from the same batch.  相似文献   

7.
A simple and miniaturized sample preparation method for determination of amphetamines in urine was developed using on-column derivatization and gas chromatography-mass spectrometry (GC-MS). Urine was directly applied to the extraction column that was pre-packed with Extrelut and sodium carbonate. Amphetamine (AP) and methamphetamine (MA) in urine were adsorbed on the surface of Extrelut. AP and MA were then converted to a free base and derivatized to N-propoxycarbonyl derivatives using propylchloroformate on the column. Pentadeuterated MA was used as an internal standard. The recoveries of AP and MA from urine were 100 and 102%, respectively. The calibration curves showed linearity in the range of 0.50-50 microg/mL for AP and MA in urine. When urine samples containing two different concentrations (0.50 and 5.0 microg/mL) of AP and MA were determined, the intra-day and inter-day coefficients of variation were 1.4-7.7%. This method was applied to 14 medico-legal cases of MA intoxication. The results were compared and a good agreement was obtained with a HPLC method.  相似文献   

8.
A fatal overdose involving case by 5-methoxy-N,N-diisopropyltryptamine (5-MeO-DIPT) is reported. 5-MeO-DIPT and its two metabolites, 5-hydroxy-N,N-diisopropyltryptamine (5-OH-DIPT) and 5-methoxy-N-isopropyltryptamine (5-MeO-NIPT), were identified by LC-MS. The level of 5-MeO-DIPT, 5-OH-DIPT and 5-MeO-NIPT in blood and urine was 0.412, 0.327 and 0.020 microg/ml, and 1.67, 27.0 and 0.32 microg/ml, respectively. These blood and urine levels were higher than published data for such poisoning.  相似文献   

9.
This study compared endogenous gamma-hydroxybutyric acid (GHB) concentrations in various postmortem fluid samples of 25 autopsy cases. All bodies were stored between 10-20 degrees C until autopsy, and the intervals between death and autopsy were less than 2 days (6-48 h). GHB concentrations were measured by headspace gas chromatography after GHB was converted to gamma-butyrolactone. Endogenous GHB concentrations were significantly higher in femoral venous blood (4.6+/-3.4 microg/ml, n=23) than in cerebrospinal fluid (1.8+/-1.5 microg/ml, n=9), vitreous humor (0.9+/-1.7 microg/ml, n=8), bile (1.0+/-1.1 microg/ml, n=9) and urine (0.6+/-1.2 microg/ml, n=12). GHB concentrations were similar in blood samples taken from different sites. Cut-off limits of 30 and 10 microg/ml are proposed for blood and urine, respectively, to discriminate between exogenous and endogenous GHB in decedents showing no or little putrefaction (postmortem intervals usually 48 h or less). The criterion established for endogenous GHB in postmortem urine may also be applicable to analytical results in cerebrospinal fluid, vitreous humor and bile from deceased persons.  相似文献   

10.
Acetylcodeine (AC), an impurity of illicit heroin synthesis, was investigated as a urinary biomarker for detection of illicit heroin use. One hundred criminal justice urine specimens that had been confirmed positive by GC/MS for morphine at concentrations >5000 ng/ml were analyzed for AC, 6-acetylmorphine (6AM), codeine, norcodeine and morphine. The GC/MS analysis was performed by solid phase extraction and derivatization with propionic anhydride. Total codeine and morphine concentrations were determined by acid hydrolysis and liquid/liquid extraction. AC was detected in 37 samples at concentrations ranging from 2 to 290 ng/ml (median, 11 ng/ml). 6AM was also present in these samples at concentrations ranging from 49 to 12 600 ng/ml (median, 740 ng/ml). Of the 63 specimens negative for AC, 36 were positive for 6AM at concentrations ranging from 12 to 4600 ng/ml (median, 124 ng/ml). When detected, the AC concentrations were an average of 2.2% (0.25 to 10.2%) of the 6AM concentrations. There was a positive relationship between AC concentrations and 6AM concentrations (r=0.878). Due to its very low concentration in urine, AC was found to be a much less reliable biomarker for illicit heroin use than 6AM in workplace or criminal justice urine screening programs. However, AC detection could play an important role in determining if addicts in heroin maintenance programs are supplementing their supervised diacetylmorphine doses with illicit heroin.  相似文献   

11.
The elimination time of illicit drugs and their metabolites is of both clinical and forensic interest. In order to determine the elimination time for various drugs and their metabolites we recruited 52 volunteers in a protected, low-step detoxification program. Blood samples were taken from each volunteer for the first 7 days, daily, urine sample for the first 3 weeks, daily. Urine was analyzed using a fluorescence-polarization immunoassay (FPIA) and gas chromatography/mass spectrometry (GC/MS), serum using GC/MS. The elimination times of the drugs and/or their metabolites in urine and serum as well as the tolerance intervals/confidence intervals were determined. Due to the sometimes extremely high initial concentrations and low cut-off values, a few of the volunteers had markedly longer elimination times than those described in the literature. The cut-off values were as follows: barbiturates II (200ng/ml), cannabinoids (20ng/ml), cocaine metabolites (300ng/ml), opiates (200ng/ml). GC/MS detected the following maximum elimination times: total morphine in urine up to 270.3h, total morphine and free morphine in serum up to 121.3h, monoacetylmorphine in urine up to 34.5h, 11-nor-9-carboxy-delta-9-tetrahydrocannabinol (THC-COOH) in urine up to 433.5h, THC-COOH in serum up to 74.3h, total codeine in urine up to 123h, free codeine in urine up to 97.5h, total codeine in serum up to 29h, free codeine in serum up to 6.3h, total dihydrocodeine (DHC) in urine up to 314.8h, free DHC in urine up to 273.3h, total and free DHC in serum up to 50.1h. Cocaine and its metabolites were largely undetectable in the present study.  相似文献   

12.
Impurity profiling of methamphetamine (MA) using thermal desorption (TD) and gas chromatography-mass spectrometry (GC-MS) was examined. Using TD/GC-MS, impurities were extracted and separated under various conditions. Optimal chromatograms were obtained when a 20 mg MA sample was extracted at 120 degrees C for 3 min using a TD instrument, followed by separation of the extracts using a non-polar capillary column coated with (5%phenyl)-methylpolysiloxane. MA samples from nine different batches were analyzed under optimized conditions. Compounds related to the structure of MA, such as benzaldehyde, benzyl alcohol, amphetamine, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, and N-acetylephedrine, were detected in the chromatograms without any laborious extraction procedure. Compounds such as ethanol, diethyl ether, and acetic acid, which are considered reagents and solvents for MA synthesis, were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different among the samples. Impurity profiling of MA using TD was compared with that using liquid-liquid extraction (LLE). Better reproducibility of peak areas was obtained using LLE, whereas higher intensities and numbers of peaks were detected using TD. Solvents were extracted more effectively using TD. The nine batches of MA were classified using both extraction procedures. The nine batches were divided roughly into two groups using data from LLE. Subsequently, the groups were classified in detail using data from TD. TD can be used to provide supplemental information for LLE, and the combination of these extraction methods can be helpful for impurity profiling of MA.  相似文献   

13.
Nineteen crystalline methamphetamine ('ice') seizures captured by the Australian Federal Police (AFP) at the Australian border between 1998 and 2002 were analysed. Using a modified gas chromatograph-mass spectrometry (GC-MS) impurity profiling approach of these samples we have identified >30 compounds associated with methamphetamine and/or its synthetic route. Major impurities detected include 1,2-dimethyl-3-phenylaziridine 8, dimethylamphetamine 14, N-formylmethamphetamine 24, N-acetylmethamphetamine 25, 1,3-dimethyl-2-phenylnaphthalene 32, 1-benzyl-3-methylnaphthalene 33 and methamphetamine dimer 34. These data are suggestive of ephedrine/pseudoephedrine as the main precursor of the 'ice' samples seized during 1998-2002. Additionally the two naphthalenes 32 and 33 further identified that 15 items in 9 seizures were produced via the more specific ephedrine/hydriodic acid/red phosphorus method. One sample comprised 75% dimethylamphetamine and 9.7% methamphetamine, representing the first Australian seizure of imported dimethylamphetamine reported.  相似文献   

14.
We report a case of intoxication resulting from the ingestion of a liquid, sold in the illicit market as "liquid ecstasy," which was found to contain 1,4-butanediol, a metabolic precursor of gamma-hydroxybutiric acid (GHB). Identification of the substance in the liquid was performed by gas chromatography-mass spectrometry (GC-MS).The toxicological analysis of blood, urine and gastric content of the victim was performed by immunoassay and gas chromatography with nitrogen-phosphorus detection as screening techniques and by means of GC-MS for confirmation and quantitation of 1,4-butanediol and GHB. The following drug concentrations were found: 82 microg/ml (blood), 401 microg/ml (urine) and 7.4 microg/ml (gastric content) for 1,4-butanediol and 103 microg/ml (blood), 430.0 microg/ml (urine) for GHB. In addition to these, other drugs detected and their blood concentration found in this case were methylenedioxymethylamphetamine (MDMA) 0.23 microg/ml and its metabolite methylenedioxyphenylamphetamine (MDA) 0.10 microg/ml. In the urine, a concentration of 0.10 microg/ml of benzoylecgonine was also found.  相似文献   

15.
A simple and highly sensitive method for analysis of derivatized methamphetamine (MA) and amphetamine (AM) in whole blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry electron impact ionization selected ion monitoring (GC-MS-EI-SIM). A whole blood sample, deuterated-MA (d(5)-MA), as an internal standard (IS), tri-n-propylamine and pentafluorobenzyl bromide were placed in a vial. The vial was heated and stirred at 90 degrees C for 30min. Then the extraction fiber of the SPME was exposed at 90 degrees C for 30min in the headspace of the vial while being stirred. The derivatives adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves showed linearity in the range of 0.5-1000ng/g for both MA and AM. The time for analysis was about 80min per sample. In addition, this proposed method was applied to two autopsy cases where MA ingestion was suspected. In one case, MA and AM concentrations in the mixed left and right heart blood were 165 and 36.9ng/g, respectively. In the other case, MA and AM concentrations were 1.79 and 0.119 microg/g in the left heart blood, and 1.27 and 0.074 microg/g in the right heart blood, respectively.  相似文献   

16.
A fast and simple method to detect some commonly abused illicit drugs, amphetamine, methamphetamine, 3,4-methylendioxy-amphetamine (MDA), 3,4-methylendioxy-methamphetamine (MDMA), 3,4-methylendioxy-N-ethylamphetamine (MDEA) and phencyclidine (PCP) in urine using solvent microextraction (SME) combined with gas chromatography (GC) analysis has been developed. The extraction is conducted by suspending a 2 microl drop of chloroform in a 2 ml urine sample. Following 8 min of extraction, the organic solvent is withdrawn into the syringe and injected into a GC with a pulsed discharge helium ionization detector (PDHID). The effects of different extraction solvents and times, pH and sample preparation were studied. The optimized method was capable of detecting drugs in urine at concentrations below Substance Abuse and Mental Health Services Administration (SAMHSA) established cut-off values for preliminary testing. Good linearity and reproducibility of extraction were obtained. The limits of detection were 0.5 microg/ml for amphetamine, 0.1 microg/ml for methamphetamine and MDA, 0.05 microg/ml for MDMA, 0.025 microg/ml for MDEA and 0.015 microg/ml for PCP. Relative standard deviation (R.S.D.) values ranged between 5 and 20% for the studied drugs.  相似文献   

17.
Pholedrine (4'-hydroxymethamphetamine) is a cardiovascular agent exerting hypertensive and adrenergic effects. High doses may cause a drop in the peripheral circulation blood flow and increase blood pressure, heart rate and body temperature up to a state of central respiratory paralysis. A 15-year-old girl who suffered from heavy agitation and hallucinations was admitted to the intensive care unit in a comatose state. The clinical findings included a maximum heart rate of 170 bpm and a body temperature of 43.8 degrees C. Resuscitation measures were in vain and abandoned after approximately 2h. A toxicological emergency analysis using GC/MS revealed a considerable amount of pholedrine in blood and urine. A method for determining pholedrine in human body fluids utilizing high-performance liquid chromatography (HPLC)/tandem mass spectrometry (LC-MS/MS) with a turbo ion-spray source was developed, using D11-methamphetamine and D5-methylenedioxymethamphetamine as internal standards. Samples were prepared by SPE extraction using SPEC-C18AR/MP3((R)) columns, which yielded the best extraction recovery (67%). Chromatographic separation was achieved at pH 5 on an RP-18 stationary phase applying gradient elution from 50 to 70% of B (methanol/acetonitrile 3/1 (v/v), 0.02% acetic acid) in A (5mM ammonium acetate/acetonitrile 95/5 (v/v), 0.02% acetic acid). Supra-pure acetic acid was added to the post-column effluent with a flow rate of 0.2 microl/min to optimize ionization. Detection was carried out in the positive ionization, multiple reaction monitoring (MRM) mode. The chromatograms showed no interference from other substances. The limit of detection (LOD, S/N=3) of pholedrine was 0.8 ng/ml and its lower limit of quantification (LLOQ, S/N=10) 3ng/ml. The calibration curve was linear (r=0.999) in the range 1-100 ng/ml. Samples with higher concentrations were diluted to suit the working range. The intra-day R.S.D. between 5 and 80 ng/ml were 3.8-8.7% and the inter-day R.S.D. between 5 and 100 ng/ml were 6.7-10.7%. The pholedrine concentrations in blood and urine collected when the girl was still alive were 16.1 microg/ml (R.S.D. 10.5%) and 1120 microg/ml (R.S.D. 8%), respectively. In post-mortem samples, they were 23.0 microg/ml (R.S.D. 5.1%) in heart blood and 27.3 microg/g (R.S.D. 6.6%) in the liver.  相似文献   

18.
The profiling of impurities in methamphetamine (MA) using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) is described. The extraction of the impurities with an SPME fiber was examined under varying conditions. Optimal chromatograms were obtained when a 50 mg MA sample at 85 degrees C for 30 min was extracted using a fiber coated with divinylbenzene/carboxen/polydimethylsiloxane. MA samples from nine different origins were analyzed under optimized extraction conditions. Compounds related to MA such as benzaldehyde, benzyl alcohol, amphetamine, benzyl methyl ketone, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, N-acetylamphetamine, N-acetylmethamphetamine and N-formylmethamphetamine were detected in the chromatograms. Trace amounts of ethanol, diethyl ether and acetic acid were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different, depending on the sample. After the areas of the eight principal peaks were converted to their square root and logarithm, similarities among the samples were evaluated by Euclidian distance, cosine distance and correlation coefficient. The results showed that a combination of logarithmic conversion and cosine distance was the most suitable for discriminating and classifying the samples. HS-SPME/GC-MS is a simple and effective method for the extraction and identification of impurities. The present method, in combination with an appropriate statistical analysis, would be useful for developing a profile of impurities in MA.  相似文献   

19.
A simple and rapid procedure for the determination of methyl-parathion (m-p) in post-mortem biological samples was developed using headspace solid phase microextraction (SPME) and gas chromatography (GC) with nitrogen-phosphorous detection (NPD). Methyl-parathion was extracted on 85 microm polyacrylate SPME fiber. Salt addition, extraction temperature, and extraction time were optimized to enhance the sensitivity of the method. The linearity (y = 0.0473x - 0.0113, R2 = 0.9992) and the dynamic range (0.1-40 microg/ml) were found very satisfactory. The recoveries of methyl-parathion were found to be 46% in spiked human whole blood, 53% in spiked homogenized liver tissue, and 54% in spiked homogenized kidney tissue compared with samples prepared in water. The coefficients of variations for 2, 4, and 20 microg/ml of methyl-parathion in blood ranged from 0.9 to 5.1%, whereas the detection limit of the method was satisfactory (1 ng/ml in aqueous samples, 50 ng/ml in whole blood). The developed procedure was applied to post-mortem biological samples from a 21-year-old woman fatally poisoned (suicide) by intravenous injection of methyl-parathion. The intact insecticide was found in the post-mortem blood at a concentration of 24 microg/ml. No methyl-parathion was detected in the liver, kidneys, and gastric contents.  相似文献   

20.
目的 通过UPLC-HRMS检测分析体外人肝微粒体模型中合成大麻素类新精神活性物质AB-CHMINACA的代谢物并与一例真实滥用者的尿液样本进行对比,从而对体外人肝微粒体模型预测体内代谢物的一致性进行评价研究.方法 通过建立体外人肝微粒体孵育模型模拟人体体内代谢过程,尿液样本经简单的乙腈沉淀蛋白后利用高分辨质谱(HRM...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号