1.
A Bayesian soft classification method combined with target factor analysis (TFA) is described and tested for the analysis of fire debris data. The method relies on analysis of the average mass spectrum across the chromatographic profile (i.e., the total ion spectrum, TIS) from multiple samples taken from a single fire scene. A library of TIS from reference ignitable liquids with assigned ASTM classification is used as the target factors in TFA. The class-conditional distributions of correlations between the target and predicted factors for each ASTM class are represented by kernel functions and analyzed by Bayesian decision theory. The soft classification approach assists in assessing the probability that ignitable liquid residue from a specific ASTM E1618 class, is present in a set of samples from a single fire scene, even in the presence of unspecified background contributions from pyrolysis products. The method is demonstrated with sample data sets and then tested on laboratory-scale burn data and large-scale field test burns. The overall performance achieved in laboratory and field test of the method is approximately 80% correct classification of fire debris samples.  相似文献   

2.
A multistep classification scheme was used to detect and classify ignitable liquid residues in fire debris into the classes defined by the ASTM E1618‐10 standard method. The total ion spectra (TIS) of the samples were classified by soft independent modeling of class analogy (SIMCA) with cross‐validation and tested on fire debris. For detection of ignitable liquid residue, the true‐positive rate was 94.2% for cross‐validation and 79.1% for fire debris, with false‐positive rates of 5.1% and 8.9%, respectively. Evaluation of SIMCA classifications for fire debris relative to a reviewer's examination led to an increase in the true‐positive rate to 95.1%; however, the false‐positive rate also increased to 15.0%. The correct classification rates for assigning ignitable liquid residues into ASTM E1618‐10 classes were generally in the range of 80–90%, with the exception of gasoline samples, which were incorrectly classified as aromatic solvents following evaporative weathering in fire debris.  相似文献   

3.
Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618‐10 standard method. A multistep classification procedure was tested by cross‐validation based on model data sets comprised of the time‐averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory‐scale and field test burns were also used to test the model. The optimal model's true‐positive rate was 81.3% for cross‐validation samples and 70.9% for fire debris samples. The false‐positive rate was 9.9% for cross‐validation samples and 8.9% for fire debris samples.  相似文献   

4.
Classification of ignitable liquids in accordance with voluntary consensus-based standards published by ASTM International has become increasingly specific, relying upon both the chemical composition and the boiling point range of submitted ignitable liquids. This classification system includes among others, specific classes for distillates and dearomatized distillates. In this study, a variety of medium-range ignitable liquids were analyzed by gas chromatography-mass spectrometry. Several methods of data analysis were utilized to examine the relative aliphatic and aromatic contents in these liquids. Results show that commercially available products in the medium range exhibit a broad range of compositions with respect to the relative proportion of aliphatic and aromatic compounds and that some liquids may not be easily classified. This study demonstrates the importance of examining the proportion of aliphatics:aromatics for classifying such liquids and suggests guidelines for differentiating medium range distillates, dearomatized distillates, and blended products.  相似文献   

5.
The application of comprehensive two-dimensional gas chromatography (GC x GC) for the forensic analysis of ignitable liquids in fire debris is reported. GC x GC is a high resolution, multidimensional gas chromatographic method in which each component of a complex mixture is subjected to two independent chromatographic separations. The high resolving power of GC x GC can separate hundreds of chemical components from a complex fire debris extract. The GC x GC chromatogram is a multicolor plot of two-dimensional retention time and detector signal intensity that is well suited for rapid identification and fingerprinting of ignitable liquids. GC x GC chromatograms were used to identify and classify ignitable liquids, detect minor differences between similar ignitable liquids, track the chemical changes associated with weathering, characterize the chemical composition of fire debris pyrolysates, and detect weathered ignitable liquids against a background of fire debris pyrolysates.  相似文献   

6.
Ignitable liquids such as fuels, alcohols and thinners can be used in criminal activities, for instance arsons. Forensic experts require to know their chemical compositions, as well as to understand how different modification effects could impact them, in order to detect, classify and identify them properly in fire debris. The acid alteration/acidification of ignitable liquids is a modification effect that sharply alters the chemical composition, for example, of gasoline and diesel fuel, interfering in the forensic analysis and result interpretation. However, to date there is little information about the consequences of this effect over other accelerants of interests. In this research paper, the alteration by sulfuric acid of several commercial thinners and other accelerants of potential use in arsons is studied in-depth. For that purpose, spectral (by ATR-FTIR) and chromatographic (by GC–MS) data were obtained from neat and acidified samples. Then, the spectral and chromatographic modifications of each studied ignitable liquid were discussed, proposing several chemical mechanisms that explain the new by-products produced and the gradual disappearance of the initial compounds. Hydrolysis, Fischer esterification and alkylation reactions are involved in the modification of esters, alcohols, ketones and aromatic compounds of the studied ignitable liquids. This information could be crucial for correctly identifying these accelerants. Additionally, an exploratory analysis revealed that some of the most altered ignitable liquid samples might be very similar with each other, which could have impact on casework.  相似文献   

7.
Vinyl flooring manufacturers use plasticizers to decrease the viscosity and increase the pliability of vinyl. Several ignitable liquid plasticizers used in the manufacture of vinyl flooring were identified and investigated in this study. Twenty-nine collections from five major vinyl manufacturers, a total of 72 samples, were analyzed using passive headspace concentration in accordance with the American Society for Testing and Materials (ASTM E 1412-00) and gas chromatographic-mass spectrometric (GC-MS) analysis as described in ASTM E 1618-01 (1,2). Norpar products and TXIB (2,2,4-trimethyl-1,3-pentanediol diisobutyrate) are ignitable liquids common to the manufacture of vinyl flooring and were identified in all recently obtained samples. Isopar H is an ignitable liquid found in various products such as charcoal starters, copier toners, and some solvents (2). Of the 29 collections analyzed, Isopar H was only identified in Armstrong's Interflex-Traditions pattern.  相似文献   

8.
Abstract: In fire debris analysis, weathering of ignitable liquids and matrix interferences can make the identification of ignitable liquid residues (ILRs) difficult. An objective method was developed to associate ILRs with the corresponding neat liquid with discrimination from matrix interferences using principal components analysis (PCA) and Pearson product moment correlation (PPMC) coefficients. Six ignitable liquids (gasoline, diesel, ultra pure paraffin lamp oil, adhesive remover, torch fuel, paint thinner) were spiked onto carpet, which was burned, then extracted using passive headspace extraction, and analyzed by gas chromatography‐mass spectrometry. Both light and heavy burn conditions were investigated. In the PCA scores plot, ignitable liquids were discriminated based on alkane and aromatic content. All ILRs were successfully associated with the corresponding neat liquid using both PCA and PPMC coefficients, regardless of the extent of burning. The method developed in this research may make the association of ILRs with corresponding neat liquids more objective.  相似文献   

9.
In arson cases, the collection and detection of traces of ignitable liquids on a suspect's hands can provide information to a forensic investigation. Police forces currently lack a simple, robust, efficient and reliable solution to perform this type of swabbing.In this article, we describe a study undertaken to develop a procedure for the collection of ignitable liquid residues on the hands of arson suspects. Sixteen different collection supports were considered and their applicability for the collection of gasoline traces present on hands and their subsequent analysis in a laboratory was evaluated. Background contamination, consisting of volatiles emanating from the collection supports, and collection efficiencies of the different sampling materials were assessed by passive headspace extraction with an activated charcoal strip (DFLEX device) followed by gas chromatography–mass spectrometry (GC–MS) analysis. After statistical treatment of the results, non-powdered latex gloves were retained as the most suitable method of sampling.On the basis of the obtained results, a prototype sampling kit was designed and tested. This kit is made of a three compartment multilayer bag enclosed in a sealed metal can and containing three pairs of non-powdered latex gloves: one to be worn by the sampler, one consisting of a blank sample and the last one to be worn by the person suspected to have been in contact with ignitable liquids. The design of the kit was developed to be efficient in preventing external and cross-contaminations.  相似文献   

10.
Identification of an ignitable liquid in fire debris evidence can be complicated due to evaporation of the liquid, matrix interferences, and thermal degradation of both the liquid and the matrix. In this research, liquids extracted from simulated fire debris were compared to the original liquid using multivariate statistical procedures. Neat and evaporated gasoline and kerosene standards were spiked onto nylon carpet, which was subsequently burned. The ignitable liquid residues were extracted using a passive headspace procedure and analyzed by gas chromatography-mass spectrometry. Pearson product moment correlation coefficients, hierarchical cluster analysis, and principal components analysis were used to compare the liquids extracted from the carpet to the corresponding neat liquid. For each procedure, association of the extracts according to liquid type was possible, albeit not necessarily to the specific evaporation level. Of the three procedures investigated, principal components analysis offered the most promise since contributions from matrix interferences were essentially eliminated.  相似文献   

11.
ASTM standards for fire debris analysis: a review   总被引:7,自引:0,他引:7  
The American Society for Testing and Materials (ASTM) recently updated its standards E 1387 and E 1618 for the analysis of fire debris. The changes in the classification of ignitable liquids are presented in this review. Furthermore, a new standard on extraction of fire debris with solid phase microextraction (SPME) was released. Advantages and drawbacks of this technique are presented and discussed. Also, the standard on cleanup by acid stripping has not been reapproved.Fire debris analysts that use the standards should be aware of these changes.  相似文献   

12.
Fast Gas Chromatography (GC) allows for analysis times that are a fraction of those seen in traditional capillary GC. Key modifications in fast GC include using narrow, highly efficient columns that can resolve mixtures using a shorter column length. Hence, a typical fast GC column has an inner diameter of 100–180 μm. However, to maintain phase ratios that are consistent with typical GC columns, the film thickness of fast GC stationary phases are also low (e.g., 0.1–0.18 μm). Unfortunately, decreased film thickness leads to columns with very low sample capacity and asymmetric peaks for analytes that are not sufficiently dilute. This paper describes micro-bore (50 μm i.d.) capillary columns with thick films (1.25 μm), and low phase ratios (10). These columns have greater sample capacity yet also achieve minimum plate heights as low as 110 μm. Hence, separation efficiency is much higher than would be obtained using standard GC columns. The capillary columns were prepared in-house using a simple static-coating procedure and their plate counts were determined under isothermal conditions. The columns were then evaluated using temperature programming for fast GC–MS analysis of ignitable liquids and their residues on fire debris exemplars. Temperature ramps of up to 75 °C min?1 could be used and separations of ignitable liquids such as gasoline, E85 fuel, and lighter fluid (a medium petroleum distillate) were complete within 3 min. Lastly, simulated fire debris consisting of ignitable liquids burned on carpeting were extracted using passive headspace absorption-elution and the residues successfully classified.  相似文献   

13.
《Science & justice》2020,60(4):381-387
Two-dimensional gas chromatography is a mature, yet underutilised, separation technique able to provide the high resolution and peak capacity required for the study of complex samples such as oils. This paper presents the development of a comprehensive two-dimensional gas chromatography method with flame ionisation detection to profile easily available ignitable liquids commonly found in arson cases. The use of 2D chromatograms to profile different potential ignitable liquids was also explored for classification purposes. The chemical fingerprints produced were visually different and allowed the distinction of all the petroleum products tested. How the chemical fingerprints of each fuel changed over time was also assessed. Each sample was subjected to weathering with aliquots (1 mL) being collected every half hour for a five-hour period. Principal component analysis of the resulting data was able to demonstrate the effect of weathering for all fuels tested and established that it was still possible to differentiate between the various petrochemicals even after weathering. The work demonstrates an optimised analytical method for petrochemical product analysis that provides forensic scientists with a robust, fast and sensitive technique that can be used to determine not only which ignitable liquid was used in a fire (even after the fact) but also provide information on the specific fuel used.  相似文献   

14.
The recent National Academy of Sciences report on forensic sciences states that the study of fire patterns and debris in arson fires is in need of additional work and eventual standardization. We discuss a recently introduced method that can provide predicted evaporation patterns for ignitable liquids as a function of temperature. The method is a complex fluid analysis protocol, the advanced distillation curve approach, featuring a composition explicit data channel for each distillate fraction (for qualitative, quantitative, and trace analysis), low uncertainty temperature measurements that are thermodynamic state points that can be modeled with an equation of state, consistency with a century of historical data, and an assessment of the energy content of each distillate fraction. We discuss the application of the method to kerosenes and gasolines and outline how expansion of the scope of fluids to other ignitable liquids can benefit the criminalist in the analysis of fire debris for arson.  相似文献   

15.
The differing effects of weathering and microbial degradation are described here in a comprehensive study that involved 50 different ignitable liquids from the Ignitable Liquids Database and Reference Collection. Examples of ignitable liquid residues from each of the main classes established by the American Society of Testing and Materials are presented. Weathering was accomplished via evaporation, whereas microbial degradation was carried out on soil at room temperature for periods of up to 21 days. Major trends included the rapid degradation of long n‐alkanes and monosubstituted alkyl benzenes (e.g., toluene, ethylbenzene, and propylbenzene). Surprisingly, some longer branched alkanes (e.g., trimethyloctanes) were also susceptible to microbial attack. Although all ignitable liquids examined suffered at least to some extent from microbial degradation, gasoline, petroleum distillates, and oxygenates were the most susceptible. Isoparaffinic and naphthenic–paraffinic products were the most resistant to microbial degradation.  相似文献   

16.
《Science & justice》2014,54(6):401-411
In the investigation of arson, evidence connecting a suspect to the fire scene may be obtained by comparing the composition of ignitable liquid residues found at the crime scene to ignitable liquids found in possession of the suspect. Interpreting the result of such a comparison is hampered by processes at the crime scene that result in evaporation, matrix interference, and microbial degradation of the ignitable liquid.Most commonly, gasoline is used as a fire accelerant in arson. In the current scientific literature on gasoline comparison, classification studies are reported for unevaporated and evaporated gasoline residues. In these studies the goal is to discriminate between samples of several sources of gasoline, based on a chemical analysis. While in classification studies the focus is on discrimination of gasolines, for forensic purposes a likelihood ratio approach is more relevant.In this work, a first step is made towards the ultimate goal of obtaining numerical values for the strength of evidence for the inference of identity of source in gasoline comparisons. Three likelihood ratio methods are presented for the comparison of evaporated gasoline residues (up to 75% weight loss under laboratory conditions). Two methods based on distance functions and one multivariate method were developed. The performance of the three methods is characterized by rates of misleading evidence, an analysis of the calibration and an information theoretical analysis.The three methods show strong improvement of discrimination as compared with a completely uninformative method. The two distance functions perform better than the multivariate method, in terms of discrimination and rates of misleading evidence.  相似文献   

17.
A new, fast, and ultra-sensitive headspace sampling method using the Capillary Microextraction of Volatiles (CMV) device is demonstrated for the analysis of ignitable liquid residues (ILRs) in fire debris. This headspace sampling method involves the use of a heated can (60°C) to aid in the recovery of volatile organic compounds (VOCs) from medium and heavy petroleum distillates. Our group has previously reported the utility of CMV to extract gasoline at ambient temperature in less than 5 min in the field. This work evaluates the recovery and analysis of low mass loadings (tens of ng) of VOCs from charcoal lighter fluid, kerosene, and diesel fuel. Nonane, decane, undecane, tridecane, tetradecane, and pentadecane were selected for evaluation of recovery to represent these ILR classes. The face-down heated can headspace sampling technique was compared to the previously reported, non-heated, paper cup headspace sampling technique. Mass recovery improvements of 50%–200% for five of the six target compounds in diesel fuel were achieved compared to the non-heated sampling method. The average relative standard deviation (reported as % RSD) between the replicate trials decreased from an average of 28% to 6% when using the heated can method. Ignitable liquids were spiked onto burned debris in a live burn exercise and sampled using the heated can and paper cup headspace sampling techniques. The heated sampling technique reported here, for the first time, demonstrates an effective extraction method that when coupled to a portable GC–MS instrument allows for a sampling and analysis protocol in the field in less than 30 min.  相似文献   

18.
The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid‐phase microextraction (HS‐SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS‐SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions—extraction temperature, incubation and exposure time—were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled‐atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris.  相似文献   

19.
Solid-phase microextraction (SPME) is well documented with respect to its convenience and applicability to sampling volatiles. Nonetheless, fire debris analysts have yet to widely adopt SPME as a viable extraction technique, although several fire debris studies have demonstrated the utility of SPME coupled with gas chromatography-mass spectrometry (GC-MS) to identify ignitable liquids. This work considers the expansion of SPME sampling from the customary thermal desorption mode to solvent-based analyte desorption for the analysis of ignitable residues. SPME extraction fibers are desorbed in 30 microL of nonaqueous solvent to yield a solution amenable to conventional GC-MS analysis with standard autosampler apparatus. This approach retains the advantages of convenience and sampling time associated with thermal desorption while simultaneously improving the flexibility and throughput of the method. Based on sampling results for three ignitable liquids (gasoline, kerosene, anddiesel fuel) in direct comparisons with the widely used activated charcoal strip (ACS) method this methodology appears to be a viable alternative to the routinely used ACS method.  相似文献   

20.
The effects of a Micelle Encapsulator Fire Suppression Agent (F-500, Hazard Control Technologies Inc., Fayetteville, Georgia) on the routine analysis of fire debris samples by Gas Chromatography (GC) were studied. When mixed with water the product can be used in the suppression of Class A and Class B fires. Laboratory tests were performed to determine whether or not the product has any effect on the analysis for ignitable liquids by GC, in particular for gasoline, medium petroleum distillates. and heavy petroleum distillates. Test burns were suppressed using either the micelle encapsulator or water and samples collected from these burns were analyzed. The results of analysis show that use of the micelle encapsulator at a fire scene may affect the chromatographic data obtained from samples collected by the investigator. However, the effect does not prevent the identification of common ignitable liquids in fire debris samples.  相似文献   