首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Anecdotal reports suggest that high environmental or occupational exposures to the fuel oxygenate methyl tert-butyl ether (MTBE) may result in breath concentrations that are sufficiently elevated to cause a false positive on commercial breath-alcohol analyzers. We evaluated this possibility in vitro by establishing a response curve for simulated breath containing MTBE in ethanol. Two types of breath-alcohol analyzers were evaluated. One analyzer's principle of operation involves in situ wet chemistry (oxidation of ethanol in a potassium dichromate solution) and absorption of visible light. The second instrument uses a combination of infrared absorption and an electrochemical sensor. Both types of instruments are currently used, although the former method represents older technology while the latter method represents newer technology.The percent blood alcohol response curve was evaluated over a breath concentration range thought to be relevant to high-level environmental or occupational exposure (0-361 microg/l). Results indicate that MTBE positively biases the response of the older technology Breathalyzer when evaluated as a single constituent or in combination with ethanol. We conclude that a false positive is possible on this instrument if the MTBE exposure is very high, recent with respect to testing, and occurs in combination with ethanol consumption. The interference can be identified on the older technology instrument by a time dependent post-reading increase in the instrument response that does not occur for ethanol alone. In contrast, the newer technology instrument using infrared and electrochemical detectors did not respond to MTBE at lower levels (0-36 microg/l), and at higher levels (>72 microg/l) the instrument indicated an "interference" or "error". For this instrument, a false positive does not occur even at high MTBE levels in the presence of ethanol.  相似文献   

2.
目的建立自动顶空-气相色谱(HS-GC)内标曲线法测定血中乙醇含量的不确定评估方法。方法从分析测定程序着手,依据不确定度评定的指导性文件,分析不确定度来源,量化不确定度分量,计算检测结果的合成标准不确定度和扩展不确定度。结果各相对不确定度来自于检材重复性检测为3.4%,乙醇标准溶液为0.71%,检材为0.61%,叔丁醇内标溶液为0.41%,标准曲线为1.1%,气相色谱仪为1.3%,血液中乙醇的相对扩展不确定度为3.9%。结论血液中乙醇含量的不确定度主要来源于检材重复性检测、气相色谱仪、乙醇标准曲线。  相似文献   

3.
A woman who died in 1837 was exhumed for the purposes of moving the grave to another location. During the excavation, small white deposits of stone were uncovered in the right abdominal region, inferior to the rib cage and superior to the ilium blade. These stones were analyzed for cholesterol, bilirubin, and calcium following solubilization using methyl tert-butyl ether as a solvent. The results of these clinical chemistry analyses showed that these stones consisted primarily of cholesterol. Under these particular soil conditions encountered in this case, cholesterol gall stones are stable for at least 165 years.  相似文献   

4.
A case of fatal poisoning due to the combined effect of alcohol and gasoline following an automobile accident is described. Toxicological analyses by means of gas chromatography and gas chromatography-mass spectrometry permitted the identification and quantitation of alcohol and several hydrocarbons in the heart blood and in the gas in the lung. Great variation was found in the estimates of blood gasoline concentration, depending on which of six constituents of gasoline was chosen for quantitation. The cause of this variation is discussed, together with the possible mechanisms leading to death.  相似文献   

5.
Compositional analysis of the organic additives in smokeless handgun powder can provide forensic information to associate known and questioned samples. A reliable method for the quantitative extraction of smokeless powder additives would strengthen these measurements. To achieve quantitative recovery, both supercritical fluid extraction (SFE) and ultrasonic solvent extraction (USE) were evaluated as candidate techniques. Following a detailed evaluation of the solvent choice, the recovery of spiked additive compounds, and the effect of the powder matrix, a reliable USE technique was developed. When quantitative USE recovery of the target analytes, nitroglycerin (NG), diphenylamine (DPA), and ethyl centralite (EC), is coupled with additive measurement by micellar capillary electrophoresis (CE), compositional information can be obtained in less than 1 h.  相似文献   

6.
A protocol is presented for the collection and analysis of gunshot residues (GSR) from hair. A fine-toothed comb is used for collection of the residues. A small zip-closure bag serves as a container for both sample storage and extraction of the characteristic organic powder additives. The success of this residue recovery approach was tested on simulated shooters and victims using mannequin-supported human wig hair as well as on human shooters. Residues were collected from four weapons: a revolver and semi-automatic pistol, rifle and shotgun. One characteristic additive, nitroglycerin, was detected by capillary electrophoresis (CE) in the majority of the collection experiments.  相似文献   

7.
The Dr?ger 7110 MK III FIN Evidential breath analyzer is classified as a quantitative analyzer capable to provide sufficient evidence for establishing legal intoxication. The purpose of this study was to evaluate ethanol specificity of this instrument in the presence of other solvents. Effects of eight possible interfering compounds on ethanol analysis were determined in a procedure simulating a human breathing. Most of the compounds studied had either a negligible effect on ethanol analysis (acetone, methyl ethyl ketone, and methyl isobutyl ketone) or were detected in very low concentrations before influencing ethanol readings (methanol, ethyl acetate, and diethyl ether). However, 1-propanol and 2-propanol increased the ethanol readings significantly. Thus, Dr?ger ethanol readings should be interpreted carefully in the presence of propanol.  相似文献   

8.
Two deep frozen persons, a female and a male, were found dead in a car. There had been an explosive fire inside the car which had extinguished itself. On the floor inside the car were large pools of liquid which smelled of gasoline. The autopsy findings and routine toxicological analyses could not explain the cause of death. Carboxyhemoglobin levels in the blood samples were <10%. Analysis with a headspace gas chromatography revealed methyl tert‐butyl ether (MTBE) concentrations of 185 mg/L (female victim) and 115 mg/L (male victim) in peripheral blood. The urine MTBE concentrations were 150 mg/L and 256 mg/L, respectively. MTBE is a synthetic chemical which is added to gasoline as a fuel oxygenate. Gasoline poisoning is likely to be the cause of the death in these two cases, and MTBE can be a suitable marker of gasoline exposure, when other volatile components have vaporized.  相似文献   

9.
"蛋白粉"、瘦肉精等危害人体健康的添加剂不属于食品,生产销售上述添加剂不能定性为生产销售有毒有害食品罪。研发、生产、销售危害人体健康的添加剂必须介入他人的有责行为才会发生危害社会结果,不宜定性为以危险方法危害公共安全罪。无相应合格产品存在或不属质量不合格的不能定性为生产销售伪劣产品罪。生产销售绝对不允许买卖产品不宜定性为非法经营罪,即使属于非法经营或生产销售伪劣产品也要达5万元以上才能入罪,无法规制会危害人体健康但数额未达5万元以上的行为。《刑法》规定的漏洞导致司法机关选择最相类似罪名定处有破坏罪刑法定原则的危险,故我国《刑法》应增设研发、生产、销售危害人体健康添加剂罪。  相似文献   

10.
Five Intoxilyzer 4011AS-As were tested for their response to eleven chemicals and one mixture of chemicals. The air/water partition ratios were also determined for these eleven chemicals and one mixture. The chemicals tested and their approximate partition ratios were the following: acetaldehyde (190:1), acetone (341:1), acetonitrile (578:1), isoprene (1:1), isopropanol (1671:1), methanol (3229:1), methylene chloride (11:1), methyl ethyl ketone (229:1), toluene (5.5:1), 1,1,1-trichloroethane (14:1), trichloroethylene (20:1), and a 50:50 mixture of 1,1,1-trichloroethane and trichloroethylene (14:1). Of the eleven chemicals and one mixture studied during this experiment, only three, isopropanol, toluene, and methyl ethyl ketone, could reasonably interfere with the test, and then only under unusual circumstances--those circumstances being a slight additive effect to a breath ethanol concentration near the level required for prosecution. Any substantial additive effect from these three substances would illuminate the interference light which invalidates the test. The mean illumination point of the interference light was 0.0286 g/210 L for methyl ethyl ketone, 0.0294 for toluene, and between 0.0116 and 0.0292 for the apparent alcohol concentration for isopropanol, depending on the amount of isopropanol metabolized to acetone. Even with these unusual circumstances considered, the Intoxilyzer 4011AS-A must be viewed as an effective way of determining the ethanol concentration in human breath for evidential purposes.  相似文献   

11.
目的探讨火场样品中汽油与稀释剂燃烧残留物的区分方法。方法样品用ATD—GC—MS法检验,检验结果通过对芳烃、烷烃、茚满、和萘系列的4个特征离子色谱图与已知汽油和稀释剂作比较,并结合向量夹角法计算样品与汽油色谱指纹图的相似度来区分汽油与稀释剂残留物。结果个别品种的稀释剂燃烧残留物与汽油很相似,但彼此有某些差别。结论使用本方法,一般能将汽油与稀释剂燃烧残留物区分开。  相似文献   

12.
Measurements of the type and concentration of propellant and stabilizer additives in smokeless gunpowder are used by forensic scientists investigating the source of explosives and by military laboratories assuring the safety and efficacy of munitions. The National Institute of Standards and Technology recently assessed the state-of-the-practice of smokeless powder measurements through an international measurement comparison exercise. We here present results provided by the five participants (of 20 total) reporting quantitative as well as qualitative values for two handgun reloading powders. All five of these participants reported values for nitroglycerin (NG), ethyl centralite (EC), diphenylamine (DPA), and N-nitrosodiphenylamine (NnDPA). Several participants additionally reported the concentrations of secondary stabilizer decomposition products. The unstable NG propellant additive appears to be more susceptible to method-specific calibration biases then are the stabilizer additives. All results from one participant were strongly biased relative to those of the other four. The within-participant measurement uncertainties for all analytes were self-reported to be 1 to 5% relative; among the four concordant participants, the measurement ranges are 5 to 10% relative. There was little consistency among the participants as to what components of measurement variance were included in their uncertainty statements. A discussion of the certainties in these measurements and factors that affect the accuracy of gunpowder additive determinations is presented.  相似文献   

13.
The investigation of uncertain fatalities requires accurate determination of the cause of death, with assessment of all factors that may have contributed to it. Gasoline is a complex and highly variable mixture of aliphatic and aromatic hydrocarbons that can lead to cardiac arrhythmias due to sensitization of the myocardium to catecholamines or acts as a simple asphyxiant if the vapors displace sufficient oxygen from the breathing atmosphere. This work describes a sudden occupational fatality involving gasoline. The importance of this petroleum distillate detection and its quantitative toxicological significance is discussed using a validated analytical method. A 51 year-old Caucasian healthy man without significant medical history was supervising the repairs of the telephone lines in a manhole near to a gas station. He died suddenly after inhaling gasoline vapors from an accidental leak. Extensive blistering and peeling of skin were observed on the skin of the face, neck, anterior chest, upper and lower extremities, and back. The internal examination showed a strong odor of gasoline, specially detected in the respiratory tract. The toxicological screening and quantitation of gasoline was performed by means of gas chromatography with flame ionization detector and confirmation was performed using gas chromatography-mass spectrometry. Disposition of gasoline in different tissues was as follows: heart blood, 35.7 mg/L; urine, not detected; vitreous humor, 1.9 mg/L; liver, 194.7 mg/kg; lung, 147.6 mg/kg; and gastric content, 116,6 mg/L (2.7 mg total). Based upon the toxicological data along with the autopsy findings, the cause of death was determined to be gasoline poisoning and the manner of death was accidental. We would like to alert on the importance of testing for gasoline, and in general for volatile hydrocarbons, in work-related sudden deaths involving inhalation of hydrocarbon vapors and/or exhaust fumes.  相似文献   

14.
An extraction and determination method of most important amphetamine derivatives in serum has been developed. The procedure comprises liquid-liquid extraction with tert-butyl methyl ether of the sample under basic conditions, centrifugation, formation of hydrochloric salts after the separation of organic phase, vacuum evaporation of the organic solvent at 60 degrees C, and trifluoroacetylation by on-line flash injection with MBTFA. GC analysis was performed by electron impact GC-MS in SIM mode. In this way satisfactory identification of 12 amphetamine derivatives could be obtained. Amphetamine, methamphetamine, MDA, MDMA and MDEA could be analyzed by using pentadeuterated analogs as internal standards. Low limits of detection 2.5-6.9 ng/mL could be reached. The assay was linear within the 5-100 ng/mL range with a regression coefficient greater than 0.999 for each compound. Our derivatization method is of low cost since only 1 microL of MBTFA is used for each flash trifluoroacetylation.  相似文献   

15.
Alcohol has been the most important knockout drug in history and literature and continues to play an essential role up to now. Blunt force to the head in the form of a knockout punch is another mechanism leading to a transient loss of consciousness. Diethyl ether and chloroform are among the classical knockout substances. Although they have meanwhile been replaced by modern sedatives and hypnotics, their use is still observed in isolated cases.  相似文献   

16.
PurposeStates have adopted a number of international instrument dedicated in full or in part to privacy and data protection, at multilateral or regional levels, in binding or non-binding form. This article discusses the potential and context of the emergence of a possible global standard on data protection focusing on the 1981 Council of Europe Convention for the Protection of Individuals with Regard to the Processing of Personal Data, as amended (Convention 108+).AimsWith due regard being paid to the dynamic technological and business environment that surrounds policy-making in the field of personal data protection, this article attempts to look at some strengths, weaknesses, opportunities and challenges of Convention 108+ in the competition for becoming a global standard. It seeks to identify possible future directions and priorities, taking into account the evolving nature of international relations in a more multipolar world where multilateralism is less obviously the preferred approach to international issues.FindingsInformed by an in-depth study of relevant international instruments relating to the right to privacy this article explores several strengths and opportunities that may be built on to promote a global role for Convention 108+, but also some weaknesses and threats. In sum, it concludes that the Convention is relatively well placed to ambition becoming a global standard.  相似文献   

17.
Gas chromatography-mass spectrometry was used to compare gasoline samples obtained from different sources based on the difference in amounts of certain components found in the headspace of gasoline using target response data. Many suspected arson cases involve comparing an ignitable liquid extracted from fire debris to a liquid found in a suspect's possession to determine if they could have had a common source. Various component ratios are proposed for determining if an unevaporated gasoline sample could have originated from the same source as an evaporated gasoline extracted from fire debris. Fifty and 75% evaporated gasoline samples were both found to contain similar ratios of certain components when compared with its unevaporated source gasoline. The results of the comparisons in this study demonstrate that for cases involving gasoline that has been evaporated up to 50% and extracted from pine, it is possible to eliminate comparison samples as originating from the same source. The results of the 75% comparisons suggest it may be possible to apply the same type of comparison to cases involving 75% evaporated gasoline.  相似文献   

18.
Three public opinion studies examined public attitudes toward prevalence reduction (PR; reducing the number of people engaging in an activity) and harm reduction (HR; reducing the harm associated with an activity) across a wide variety of domains. Studies 1 and 2 were telephone surveys of California adults’ views on PR and HR strategies for a wide range of risk domains (heroin, alcoholism, tobacco, skateboarding, teen sex, illegal immigration, air pollution, and fast food). “Moral outrage” items (immoral, disgusting, irresponsible, dangerous) predicted preference for PR over HR, with disgust the most important predictor. In contrast, preferences were not predicted by whether the risk behavior was common, no one else’s business, or harmless. Study 3 explored whether there are domains where liberals might reject HR. A sample of liberal students preferred HR > PR for heroin, but PR > HR for ritual female circumcision; path analysis suggested that this reversal was explained by moral outrage rather than consequentialist judgments of harm to self and harm to others.  相似文献   

19.
目的建立火场中汽油燃烧残留物ATD-GC-MS检验结果评价方法。方法将模拟燃烧样品用ATD-GC-MS法检验,检验结果通过对芳烃、烷烃、茚满、和萘系列的4个特征离子色谱图与已知汽油作比较,并利用向量夹角法计算样品与汽油色谱指纹图的相似度来对检验结果作评价。结果有汽油作助燃剂的模拟燃烧样品与汽油色谱指纹图的相似度一般大于90%,无汽油作助燃剂的样品则在60%以下。结论利用样品的4个特征离子色谱图与已知汽油作比较,并结合样品与汽油色谱指纹图相似度的计算,能对检验结果作出客观、可靠和准确的评价。  相似文献   

20.
Alternative fuels, specifically biodiesel, biodiesel blends, and E85 fuel, have been gaining a market share over the past few years. With the emergence of these fuels, fire debris analysts should be able to recognize their characteristics since these fuels may be encountered in casework. In this study, pure biodiesel (B100) and a 20% blend of pure biodiesel with petroleum diesel (B20) are examined as liquids and are extracted from debris samples using both passive headspace concentration and solvent extraction. Typical fire debris instrumental conditions are used to analyze these samples. Components of B100 and B20 may be observed in debris samples extracted using the passive headspace concentration method, but the chromatographic patterns are different from the pure liquid samples. When solvent extraction is used as a secondary extraction method on debris samples, the resulting patterns are consistent with the pure liquids of B100 and B20. E85 fuel, a blend of 85% ethanol and 15% gasoline, can be extracted using a typical fire debris extraction technique but requires slight modifications to typical fire debris instrumental conditions. E85 is shown at various stages of evaporation to demonstrate the resiliency of the ethanol. Additionally, samples of E85 were placed on carpet, burned and extinguished to demonstrate the effects of the suppression medium on the retention of ethanol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号