首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An original liquid chromatography method with photodiode-array detection (DAD) is presented for the determination of strychnine in blood. This sensitive method allows the use of only 0.1 ml of sample. The strychnine was isolated from blood using a liquid-liquid extraction procedure and chloroquine as an internal standard. The limits of detection (LOD) and quantification were 0.06 and 0.5 mg/l, respectively. The recovery was 94% and the coefficients of variation (CV) ranged from 5.9 to 10.8%. A fatal case of strychnine poisoning is presented, with a lethal blood concentration of 25 mg/l.  相似文献   

2.
A simple and rapid procedure for the determination of methyl-parathion (m-p) in post-mortem biological samples was developed using headspace solid phase microextraction (SPME) and gas chromatography (GC) with nitrogen-phosphorous detection (NPD). Methyl-parathion was extracted on 85 microm polyacrylate SPME fiber. Salt addition, extraction temperature, and extraction time were optimized to enhance the sensitivity of the method. The linearity (y = 0.0473x - 0.0113, R2 = 0.9992) and the dynamic range (0.1-40 microg/ml) were found very satisfactory. The recoveries of methyl-parathion were found to be 46% in spiked human whole blood, 53% in spiked homogenized liver tissue, and 54% in spiked homogenized kidney tissue compared with samples prepared in water. The coefficients of variations for 2, 4, and 20 microg/ml of methyl-parathion in blood ranged from 0.9 to 5.1%, whereas the detection limit of the method was satisfactory (1 ng/ml in aqueous samples, 50 ng/ml in whole blood). The developed procedure was applied to post-mortem biological samples from a 21-year-old woman fatally poisoned (suicide) by intravenous injection of methyl-parathion. The intact insecticide was found in the post-mortem blood at a concentration of 24 microg/ml. No methyl-parathion was detected in the liver, kidneys, and gastric contents.  相似文献   

3.
4.
Accurate quantification of DNA samples is an important step in obtaining accurate and reproducible short tandem repeat (STR) profiles. Quantitative real-time-PCR has improved the speed and accuracy of DNA quantification over earlier methods, albeit at significantly greater cost per reaction. Here, the performance of reduced volume (10 microL) DNA quantification assays using the Quantifiler Human DNA Quantification Kit was evaluated using commercial standards and single source biological stains (e.g., venous blood, saliva, and semen). In addition, casework-type samples including those subjected to environmental contaminants containing PCR inhibitors and samples having undergone extensive DNA degradation were also quantified. The concentration of DNA in various forensic samples ranged from 0 to 2.9 ng/microL depending on sample source and/or environmental insult. Compared to full-scale reactions, reduced volume assays displayed equivalent to improved amplification efficiency and sample-to-sample reproducibility (+/-0.01-0.17 C(T FAM)). Furthermore, the use of data from reduced-scale Quantifiler reactions facilitated the accurate determination of the amount of sample DNA extract needed to generate quality STR profiles. The use of 10 microL-scale Quantifiler reaction volumes has the practical benefit of increasing the effective number of reactions per kit by 250%; thereby reducing the cost per assay by 60% while consuming less sample. This is particularly advantageous in cases of consumptive testing.  相似文献   

5.
The study aim was to evaluate the feasibility of a Fourier-transformed infrared (FT-IR) analyzer for out-of-laboratory use by screening the exhalations of inebriated individuals, and to determine analysis quality using common breath components and solvents. Each of the 35 inebriated participants gave an acceptable sample. Because of the metabolism of 2-propanol, the subjects exhaled high concentrations of acetone in addition to ethanol. Other volatile ingredients of technical ethanol products (methyl ethyl ketone, methyl isobutyl ketone, and 2-propanol) were also detected. The lower limits of quantification for the analyzed components ranged from 1.7 to 12 microg/L in simulated breath samples. The bias was +/-2% for ethanol and -11% for methanol. Within-day and between-day coefficients of variation were <1% for ethanol and <4% for methanol. The bias of ethanol and methanol analyses due to coexisting solvents ranged from -0.8 to +2.2% and from -5.6 to +2.9%, respectively. The FT-IR method proved suitable for use outside the laboratory and fulfilled the quality criteria for analysis of solvents in breath.  相似文献   

6.
A 55-year-old male Caucasian truck driver was dead at the scene after breathing hydrogen sulfide (H(2)S) produced by an accidental transfer of sodium hydrogen sulfide (NaHS) from a tanker truck to a tank containing 4% sulfuric acid (H(2)SO(4)) and iron(II) sulfate (FeSO(4)). Autopsy of the decedent's body revealed pulmonary edema and passive congestion in lungs, spleen, kidneys, and adrenal glands. Postmortem biological samples were analyzed for carbon monoxide, cyanide, ethanol, and drugs. Since a potential exposure to H(2)S was involved, blood was also analyzed for sulfide (S(2-)). The analysis entailed isolating S(2-) from blood as H(2)S using 0.5M H(3)PO(4), trapping the gas in 0.1M NaOH, and determining the electromotive force using a sulfide ion specific electrode. Acetaminophen at a concentration of 14.3 microg/ml was found in blood, and metoprolol was detected in the blood, liver, and kidney samples. The blood S(2-) level was determined to be 1.68 microg/ml. It is concluded that the cause of death was H(2)S poisoning associated with a hazardous material accident in an industrial situation.  相似文献   

7.
目的建立了生物样品中丁丙诺啡的高效液相色谱-电喷雾串联质谱检测方法。方法样品经固相萃取提取净化、反相液相色谱分离后进行质谱检测,根据保留时间及特征离子进行定性分析,以母离子m/z468进行定量分析。结果在10-500ng/ml(ng/g)范围内峰面积与质量浓度的线性关系良好(r^2〉0.993)。在50、100、500ng/ml(ng/g)3个添加水平,尿、血、肝中丁丙诺啡的平均回收率为74%~94%,日内测定结果的相对标准偏差小于8%,日间测定结果的相对标准偏差小于10%。结论该方法简单、灵敏,特异性强,适用于生物样品中丁丙诺啡的分析检验。  相似文献   

8.
The objective of this study was to determine the presence of corticosteroids in illegal herbal medicines using ultra‐high‐performance liquid chromatography–tandem mass spectrometry. We collected 212 herbal medicine samples that were advertised as being effective for treatment of joint pain and bone aches. Samples were from the Korean commercial market during a span of four years (2010–2013), and the method was validated. The limits of quantification ranged from 0.47 to 15.0 ng/mL, and recoveries ranged from 80.6% to 119.5%. The intra‐ and interday precision ranged from 0.18% to 8.82% and from 0.09% to 8.96%, respectively. Among the samples, three samples (1.4%) were identified as adulterants. Dexamethasone was the only compound detected in the adulterated products. As the corticosteroid–adulteration of herbal medicines may become a major problem and lead to side effects, the continued development of screening procedures for herbal medicines is critical.  相似文献   

9.
A method for the quantitative determination of strychnine in biological fluids by gas chromatography--mass spectrometry is proposed. The preparation of samples for the analysis included extraction of strychnine from blood and urine with the use of AccuBond(II) EVIDEX cartridges for solid-phase extraction and SPEC MP3 disks respectively. The efficiency of extraction was estimated at 0.05 mg/l for blood and 0.02 mg/l for urine. The detection limit was 0.10 mg/l in blood and 0.05 mg/l in urine.  相似文献   

10.
血清中盐酸曲马多的膜式固相萃取及GC/MS/SIM测定   总被引:1,自引:0,他引:1  
Zhu BL  Zhang L  Zhang SY 《法医学杂志》2006,22(6):428-430
目的建立血清中盐酸曲马多的膜式固相萃取(SPE)气-质联用分析方法。方法1mL血清用2mL0.1mol/L磷酸盐缓冲液(pH6)稀释后,用含有C18和强酸型强阳离子交换基团的SPECC18AR/MP3固相萃取柱萃取,洗脱液为含2%氨水的乙酸乙酯;选择SKF525作为内标物,用GC/MS/SIM定量测定。结果在加标量为0.1、0.2和0.5μg/mL的血清样品中,盐酸曲马多的回收率分别为98.9%、92.5%和84.8%,5次测定的RSD分别为3.2%、8.7%和10.9%;线性范围为0.1~4μg/mL,多项式回归相关系数r2=0.9939;检出限为21ng/mL;同一根萃取柱,连续使用5次,没有出现堵塞和污染,回收率及RSD未见下降。结论本方法适合于法医毒物分析。  相似文献   

11.
A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).  相似文献   

12.
Urinary endogenous concentrations of gamma-hydroxybutyric acid (GHB), alpha-hydroxybutyric acid (AHB) and beta-hydroxybutyric acid (BHB) have been investigated for both healthy humans and diabetics by using a newly optimized GC-MS procedure. The endogenous concentrations in healthy volunteers' urine ranged 0.16-2.14 microg/ml for GHB, 0.10-2.68 microg/ml for AHB and 8.51-34.7 microg/ml for BHB. In diabetics, the concentrations ranged 0.17-3.03 microg/ml for GHB, 0.14-124 microg/ml for AHB and 4.94-4520 microg/ml for BHB. Although notably elevated BHB and AHB concentrations were observed for severely uncontrolled diabetics, their GHB concentrations ranged within or near the range seen in healthy humans. The results of this study confirm the previously suggested 10 microg/ml cutoff concentration of urinary GHB to distinguish exogenous GHB, even for uncontrolled diabetic patients suffering severe ketoacidosis.  相似文献   

13.
Imidacloprid [1-(6-chloro-3pyridylmethyl)-N-nitroimidazolidin-2-ylideneamine] is a new and potent nitromethylene insecticide with high insecticidal activity at very low application rates. It is the first highly effective insecticide that, like nicotine, acts on the nervous system, causing blockage of postsynaptic nicotinergic acetylcholine receptors. Two fatal cases with this insecticide in two male individuals, of 33 and 66 years old, are presented. An LC/MS with electrospray method for measuring imidacloprid and its metabolites in post-mortem samples is described. In the chromatographic separation, a reverse-phase column XTerra MS C18 (2.1mm i.d.x 150 mm, 5 microm) was used and the mobile phase composed with acetonitrile and 0.1% formic acid (15:85), at a 0.25 mL/min flow rate. Samples were prepared with a liquid-liquid extraction procedure with dichloromethane. Calibration curves for imidacloprid in blood and urine samples were linear from 0.2 to 15 microg/mL. The mean recovery was 86% with a coefficient of variation of +/-5.9%. The detection limit was 0.002 microg/mL. Quantitative results were obtained for all post-mortem matrices available of the two fatal cases: blood, urine, stomach contents, lung, liver and kidney. The imidacloprid blood concentrations found in two-cases were 12.5 and 2.05 microg/mL. The authors validated a method to detect and quantify imidacloprid in post-mortem samples, and to our knowledge for the first time a post-mortem tissue distribution was performed on various samples for this insecticide.  相似文献   

14.
High performance liquid chromatography with diode array detection (HPLC-DAD) was used to develop a method for the simultaneous determination of morphine, codeine, 6-acetylmorphine (6AM), cocaine, benzoylecgonine (BEG), cocaethylene, methadone and its metabolite, 2-ethylidene-1,5-dimethyldiphenylpyrrolidine (EDDP), in plasma. Following solid-phase extraction with Bond Elut Certify cartridges, chromatography was performed on an X-Terra RP8 column (250 mm x 4.6 mm i.d., 5 microm particle size), using acetonitrile-phosphate buffer pH 6.53 as mobile phase and elution in the gradient mode. The detector response was linear at concentrations over the range 0.1-10 microg/mL in plasma, and the correlation coefficients for the eight drugs studied were all higher than 0.99. The average extraction recoveries from plasma ranged from 60% for BEG to 95% for methadone. The precision was acceptable, with coefficients of variation oscillating between 2.55% and 6.45%. The accuracy was found to be within satisfactory limits (+/- 8.1%). Finally, the method was applied to 21 plasma samples from fatal overdoses, obtaining positive results for two or more drugs.  相似文献   

15.
血液、尿液中氯胺酮及其代谢物去甲氯胺酮的HPLC分析   总被引:5,自引:0,他引:5  
Chen LL  Lia OL  Li WJ  Huang LY  Yan YY  Yang L  Ma XN  He R 《法医学杂志》2008,24(1):38-42
目的 建立血液、尿液中氯胺酮及其代谢物去甲氯胺酮的高效液相色谱(HPLC)分析方法.方法 以非那西丁为内标,检材加入10%的氢氧化钠溶液调节pH值为14,用甲苯提取,离心后取有机层,水浴下吹干,乙腈定容后进HPLC仪分析.结果 检测血液中氯胺酮和去甲氯胺酮的线性范围均是0.05~10μg/mL(r2>0.999 3),检测尿液中氯胺酮和去甲氯胺酮的线性范围均是0.01~50 μg/mL(r2>0.999 5).氯胺酮和去甲氯胺酮在血液和尿液中的检测限分别是0.006 μg/mL和0.003 μg/mL.血液和尿液中氯胺酮和去甲氯胺酮的回收率不低于82.4%.检测血液和尿液中氯胺酮和去甲氯胺酮的日内精密度和日间精密度均小于10.0%.将所建的方法应用于给大鼠氯胺酮后的血液和尿液中的氯胺酮和去甲氯胺酮的测定,得到了氯胺酮和去甲氯胺酮在大鼠的药时曲线和尿排药速率曲线. 结论本方法简便、快捷,适用于血液、尿液中氯胺酮及其代谢物去甲氯胺酮的分析.  相似文献   

16.
目的建立定量分析人全血中马钱子碱和士的宁的高效液相色谱质谱联用法。方法应用Oasis^TM MCX小柱进行固相萃取法提取,XTerra^TM RP18色谱柱分离。结果在该条件下,人血中马钱子碱和士的宁的线性范围为0.01—5.0μg/ml,最小检出限为0.2ng/ml;马钱子碱和士的宁在0.01—5.0μg/ml浓度范围内的回收率均在80%以上。结论高效液相色谱质谱联用法可定量测定血中马钱子碱和士的宁。  相似文献   

17.
A method for simultaneous determination of glycerol and mannitol in various human tissues was devised and for this we used high-performance liquid chromatography (HPLC). Specimens were homogenized in a mixture of chloroform and methanol, phosphate buffer (pH 7.0) and pentaerythritol (IS) solution. After centrifugation, an aliquot of the aqueous layer was evaporated to dryness and derivatized with p-nitrobenzoyl chloride at 50 degrees C for 1h, then applied to HPLC with analytical conditions of: column, CAPCELL PAK C18 MG (250 mm x 3.0 mm i.d., 5 microm, Shiseido Co. Ltd., Tokyo, Japan); column temperature, 1-2 degrees C; mobile phase, 75% acetonitrile-distilled water containing 0.05% trifluoroacetic acid, 0.05% heptafluoro-n-butyric acid and 0.1% triethylamine; flow rate, 0.5 ml/min; wavelength, 260 nm. Calibration curves for both substances were linear in concentration ranges from 1 to 500 microg/0.1g and correlation coefficients exceeded 0.99. The relative standard deviation (R.S.D.) of the method was evaluated at concentrations of 10 and 100 microg/0.1g, and ranged from 0.84 to 10.6%. Using this method, we determined the regional distribution levels of glycerol and mannitol in various tissues from an autopsied brain dead man.  相似文献   

18.
体液中微量士的宁的富集及同时检测   总被引:6,自引:0,他引:6  
Zhang J  He LC  Fu Q 《法医学杂志》2005,21(1):36-38
目的将分子印迹技术运用到法医毒物分析中,建立一种全新的测定体液中微量士的宁的方法。方法运用分子印迹原位聚合技术,在色谱柱中一步合成了对士的宁具有专属识别能力的分子印迹聚合物,以此聚合物为介质,装填一厘米的小柱,建立体液中微量士的宁的富集及同时检测方法。结果以士的宁分子印迹聚合物作为尿液和血浆中微量士的宁的富集和检测介质,方法的检出限为4.9ng,样品回收率均大于92%,相对标准偏差小于6.59%,工作曲线的线性相关系数分别为0.9991和0.9966。运用此方法对中毒家兔血浆和尿液中的士的宁进行了测定。结论建立的新方法可以实现对士的宁专属的、灵敏的检测,适合于法医学毒物分析运用。  相似文献   

19.
A simple and reliable gas chromatographic method with nitrogen-phosphorus detection without derivatization was developed for the detection of several psychiatric drugs in whole blood as part of systematic toxicological analyses (STA). Drugs included mirtazapine, chlorpromazine, methotrimeprazine (levomepromazine), clothiapine, olanzapine, clozapine, haloperidol, and thioridazine. All drugs were studied at concentrations of 100-2,000 microg/L, except haloperidol that was studied at concentrations of 400-8,000 microg/L. In order to select the best blood purification procedure and therefore increase the signal to noise ratio we have compared two solid-phase extraction (SPE) columns, Chem Elut and Bond Elut Certify, for their recovery, precision, sensitivity and matrix purification efficiency. Recoveries for these drugs using Chem Elut columns at 500 and 2,000 microg/L (2,000 and 8,000 microg/L for haloperidol) were in the range 21-65%, with intra-assay and inter-assay precisions of less than 17% and 19%, respectively. Limits of detection (LODs) and limits of quantitation (LOQs) for mirtazapine, chlorpromazine, methotrimeprazine, clothiapine, olanzapine, clozapine, and thioridazine ranged from 62 to 161 microg/L and from 205 to 531 microg/L, respectively. LOD and LOQ for haloperidol were 442 and 1,458 microg/L, respectively. Recoveries of these compounds using Bond Elut Certify columns at 500 and 2,000 microg/L (2,000 and 8,000 microg/L for haloperidol) were in the range 44-97%, with intra-assay and inter-assay precisions of less than 7% and 14%, respectively. LODs and LOQs for mirtazapine, chlorpromazine, methotrimeprazine, clothiapine, olanzapine, clozapine, and thioridazine ranged from 37 to 66 microg/L and from 122 to 218 microg/L, respectively. LOD and LOQ for haloperidol were 156 and 515 microg/L, respectively. Linearity was observed in the studied range for all compounds with r(2) values of >0.999. The use of the mixed-mode bonded-silica Bond Elut Certify columns showed advantages comparing with Chem Elut columns for the screening of these psychotropic agents such as higher recoveries, cleaner extracts, better sensitivity, better precision and less solvent consumption and subsequent disposal.  相似文献   

20.
A fast and efficient procedure has been developed for the analysis of total mercury in human tissues and blood using a hydride vapor generator system coupled to an atomic absorption spectrometer (HVG-AA). Tissue and blood samples were digested in a pressurized microwave decomposition system and the digest diluted prior to formation of free mercury vapor and analysis by atomic absorption. Recovery studies performed on 10 spiked/unspiked pairs of human liver and on 10 spiked/unspiked pairs of human blood samples yielded average recoveries of 99.7% (CV=0.4%) and 101.2% (CV=0.5%), respectively. The method detection limit for liver and blood was 50 microg Hg/kg and 12.5 microg Hg/l, respectively. The "normal" concentrations of mercury in human liver and blood are 33-490 microg Hg/kg and 0.6-59 microg Hg/l, respectively [1]. This method is able to determine mercury poisoning levels and may also be applied to detect mercury near the lower levels of these "normal" ranges, using the standard addition method approach.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号