首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
This study was aimed at determining the effect of seven blood enhancement reagents on the subsequent Profiler Plus fluorescent STR DNA analysis of fresh or aged bloody fingerprints deposited on various porous and nonporous surfaces. Amido Black, Crowle's Double Stain. 1,8-diazafluoren-9-one (DFO), Hungarian Red, leucomalachite green, luminol and ninhydrin were tested on linoleum, glass, metal, wood (pine, painted white), clothing (85% polyester/15% cotton, 65% polyester/35% cotton, and blue denim) and paper (Scott 2-ply and Xerox-grade). Preliminary experiments were designed to determine the optimal blood dilutions to use to ensure a DNA typing result following chemical enhancement. A 1:200 blood dilution deposited on linoleum and enhanced with Crowle's Double Stain generated enough DNA for one to two rounds of Profiler Plus PCR amplification. A comparative study of the DNA yields before and after treatment indicated that the quantity of DNA recovered from bloody fingerprints following enhancement was reduced by a factor of 2 to 12. Such a reduction in the DNA yields could potentially compromise DNA typing analysis in the case of small stains. The blood enhancement chemicals selected were also evaluated for their capability to reveal bloodmarks on the various porous and nonporous surfaces chosen in this study. Luminol. Amido Black and Crowle's Double Stain showed the highest sensitivity of all seven chemicals tested and revealed highly diluted (1:200) bloody fingerprints. Both luminol and Amido Black produced excellent results on both porous and nonporous surfaces, but Crowle's Double Stain failed to produce any results on porous substrates. Hungarian Red, DFO, leucomalachite green and ninhydrin showed lower sensitivities. Enhancement of bloodmarks using any of the chemicals selected, and short-term exposure to these same chemicals (i.e., less than 54 days), had no adverse effects on the PCR amplification of the nine STR systems surveyed (D3S 1358, HumvWA, HumFGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820) or of the gender determination marker Amelogenin. The intensity of the fluorescent signals was very similar and the allele size measurements remained constant and identical to those of untreated bloody fingerprints. No additional background fluorescence was noted. Continuous exposure (for 54 days) to two of the seven enhancement chemicals selected (i.e., Crowle's Double Stain and Hungarian Red) slightly reduced the amplification efficiency of the longer STR loci in profiles of fresh and 7 to 14-day-old bloodprints. This suggests that long-term exposure to these chemicals possibly affects the integrity of the DNA molecules. This study indicates that significant evidence can be obtained from fresh or aged bloody fingerprints applied to a variety of absorbent and nonabsorbent surfaces which are exposed to different enhancement chemicals for short or long periods of time. It also reaffirms that PCR STR DNA typing procedures are robust and provide excellent results when used in concert with fluorescence-based detection assays after fingerprint identification has taken place.  相似文献   

3.
The use of a new technique, Fourier transform infrared (FTIR) chemical imaging, has been demonstrated for the enhancement of latent fingermarks on a number of surfaces. Images of untreated fingermarks on glass backgrounds with excellent ridge detail were acquired using infrared chemical imaging. High quality fingermarks on glass backgrounds were also developed using ethyl cyanoacrylate (super glue) fuming and subsequent infrared chemical imaging. This new method allows the collection of images from backgrounds that traditionally pose problems for current fingermark detection methods. The background may, for example, be highly colored, have a complex pattern, or possess other pattern or image characteristics that make it difficult to separate fingermark ridges using traditional optical or luminescent visualization. One background that has proven to be a challenging surface for the development of latent fingermarks is the Australian polymer banknote. To demonstrate the power and applicability of infrared chemical imaging, fingermarks fumed with ethyl cyanoacrylate were successfully imaged from Australian polymer banknotes.  相似文献   

4.
The use of ortho- and para-phenylenediamine (OPD & PPD respectively) for the enhancement of fingerprints in blood has been investigated. Optimal pH conditions and H2O2 concentrations have been determined using UV/Vis spectroscopy. Both OPD and PPD are effective and less hazardous alternatives to the presently used 3,3'-diaminobenzidine (DAB) for the development of blood fingerprints, especially on porous surfaces. The orange color of OPD and the purple color of PPD offer alternative colors to the brown color of DAB and the light green color of ABTS for standing out against particular backgrounds. Both OPD and PPD can be used after ninhydrin treatment, but the reverse is not the case.  相似文献   

5.
Pyridyldiphenyl triazine (PDT) and three of its analogues were compared as practical reagents for visualizing unseen impressions left on the hands of a person who has held a firearm. The parent compound, PDT, gave the best results using intensity and clarity as measuring criteria. The effectiveness of the PDT reaction was then studied on 147 volunteers who had held firearms in their hands. Identifiable impressions of the metallic parts of the weapons were developed on the hands of 103 volunteers (70%). Results with females were slightly higher than with males, however, the difference was possibly statistically insignificant, and needs further study. Ferroprint and Ferrotrace, 5 commercial preparations that are based on the PDT reaction, have become a part of the professional equipment of every crime scene technician in Israel.  相似文献   

6.
Most footwear marks made in blood on a surface such as fabric tend to be enhanced in situ rather than physically recovered using a lifting technique prior to enhancement. This work reports on the use of an alginate material to recover the impressed footwear marks made in blood and deposited on a range of fabric types and colours. The lifted marks were then enhanced using acid black 1 and leuco crystal violet with excellent results.This presents a new method for the lifting and recovery of blood impressions in situ from crime scene followed by subsequent mark enhancement of the lifted impression.  相似文献   

7.
Digital enhancement software was used to enhance bitemark photographs. This enhancement technique improved the resolution of the bitemark images. Lucis was the software program utilized in this study and case applications. First, this technique was applied on known bitemark images to evaluate the potential effectiveness of this digital enhancement method. Subsequently, Lucis was utilized on two separate unsolved cases involving enhancement of bitemark evidence. One case involved a severely beaten infant with a bitemark on the upper thigh. The second case involves a bitemark observed on the breast of a female sexual assault strangulation victim. In both cases, bitemark images were significantly improved after digital enhancement.  相似文献   

8.
This study investigated the application of chemical imaging to the detection of latent fingerprints using the Condor macroscopic chemical imaging system (ChemImage Corp., Pittsburgh, USA). Methods were developed and optimised for the visualisation of untreated latent fingerprints and fingerprints processed with DFO, ninhydrin, cyanoacrylate, and cyanoacrylate plus rhodamine 6G stain. The results obtained with chemical imaging were compared to the detection achieved using conventional imaging techniques. The Condor significantly improved the detection of many prints, especially those that might be considered poor quality or borderline prints. Prints on newspaper treated with ninhydrin and DFO, and prints on white and yellow paper treated with ninhydrin, benefited the most from chemical imaging detection. In many cases, fingerprints undetectable using conventional imaging techniques could be visualised with chemical imaging. Ridge detail from untreated prints on yellow paper was also detected using the Condor. When prints of high quality were examined, both detection techniques produced quality results. The results of this project demonstrate that chemical imaging offers advantages over conventional visualisation techniques when examining latent fingerprints, especially those that would be considered difficult, such as weak prints or prints on surfaces that produce highly luminescent backgrounds. Standard testing procedures for the detection and enhancement of fingerprints by chemical imaging are presented and discussed.  相似文献   

9.
Fourier transform infrared (FTIR) chemical imaging allows the collection of fingerprint images from backgrounds that have traditionally posed problems for conventional fingerprint detection methods. In this work, the suitability of this technique for the imaging of fingerprints on a wider range of difficult surfaces (including polymer banknotes, various types of paper, and aluminum drink cans) has been tested. For each new surface, a systematic methodology was employed to optimize settings such as spectral resolution, number of scans, and pixel aggregation in order to reduce collection time and file-size without compromising spatial resolution and the quality of the final fingerprint image. The imaging of cyanoacrylate-fumed fingerprints on polymer banknotes has been improved, with shorter collection times for larger image areas. One-month-old fingerprints on polymer banknotes have been successfully fumed and imaged. It was also found that FTIR chemical imaging gives high quality images of cyanoacrylate-fumed fingerprints on aluminum drink cans, regardless of the printed background. Although visible and UV light sources do not yield fingerprint images of the same quality on difficult, nonporous backgrounds, in many cases they can be used to locate a fingerprint prior to higher quality imaging by the FTIR technique. Attempts to acquire FTIR images of fingerprints on paper-based porous surfaces that had been treated with established reagents such as ninhydrin were all unsuccessful due to the swamping effect of the cellulose constituents of the paper.  相似文献   

10.
On December 15, 2004, the Drug Enforcement Administration (DEA) published a Final Rule corrected January 4, 2005) that implemented new regulations concerning chemical mixtures that contain any of the 27 listed chemicals. The Final Rule added a new provision not previously raised by DEA in any proposed rulemaking. This newly introduced provision exempted domestic and import transactions in chemical mixtures that are regulated solely due to the presence of the List II solvent chemicals acetone, ethyl ether, 2-butanone, or toluene from the Controlled Substances Act (CSA) recordkeeping and reporting requirements. Because this exemption was not previously proposed in any rulemaking, DEA implemented this exemption on an interim basis and requested public comment on this exemption provision. Based upon a review of all comments, DEA is finalizing this exemption. As such, domestic and import transactions in chemical mixtures containing the List II chemicals acetone, ethyl ether, 2-butanone, and toluene shall be exempt from CSA chemical recordkeeping and reporting requirements.  相似文献   

11.
We report a case of fatal copper sulfate poisoning of a 30-year-old woman following treatment by an iNyanga ("witch-doctor"). The patient died 2 days later, having lapsed into a coma. Postmortem examination revealed that the patient had died of aspiration pneumonia.  相似文献   

12.
Current blood-level data are presented for drugs and chemicals of toxicologic interest. The data represent an update of previously published compilations of therapeutic, toxic and lethal blood-levels.  相似文献   

13.
14.
A dead body was found near the sea and a commercial port in north-east Italy. The man had been shot and then burnt, by using a large volume of fire accelerant. The chemical composition of the flammable mixture had to be determined in order to aid police investigations. GC-MS analysis of residual cloth and soil identified a common gasoline, together with some unrelated compounds deriving from the container used to carry the inflammable liquid. A reconstruction of the event, an examination of the surroundings where the crime took place and the cryptic chemicals found, enabled the investigators to restrict and intensify their enquiries within a specific area.  相似文献   

15.
16.
The Drug Enforcement Administration (DEA) is finalizing the Interim Rule with Request for Comment published in the Federal Register on April 23, 2007. The Interim Rule controlled the chemical N-phenethyl-4- piperidone (NPP) as a List I chemical under the Controlled Substances Act. Clandestine laboratories are using this chemical to illicitly manufacture the schedule II controlled substance fentanyl. No comments to the Interim Rule were received. This Final Rule finalizes the regulations without change.  相似文献   

17.
18.
正义是衡量一种法律制度是否可欲的终极价值目标。从正义这一价值判断标准出发,对美国反倾销法进行分析,将会使我们认识其本质:以社会福利为代价保护国内某些产业的利益,是一种实质非正义的法律体系。  相似文献   

19.
This review chronicles the characteristics of deliberate and accidental mass poisonings that occurred in World Wars I and II, in Bhopal, and in other historical cases up to and including modern wars. It also considers approaches to the investigation of such cases from the medicolegal as well as general standpoints.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号