首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The main objectives of the European project "Collaborative Harmonization of Methods for Profiling of Amphetamine Type Stimulants" (CHAMP) funded by the sixth framework programme of the European Commission, included the harmonization of MDMA profiling methods and the creation of a common database in a drug intelligence perspective. In the preliminary stages of this project, the participating laboratories analysed the physical characteristics, the chemical composition and the organic impurities of MDMA tablets, using the previously harmonized methods. The aim of the present work was to apply statistical treatments to the recorded data in order to evaluate their potential in the fight against drug trafficking. Comparable working procedures were applied on the different types of data. The first part of this article deals with organic impurities data, while the second part focuses on the potential of the physical characteristics. Organic impurities data were recorded by a harmonized Gas Chromatography/Mass Spectrometry (GC/MS) method previously developed. Statistical analysis provided a selection of pertinent variables among the 46 organic impurities identified in the chromatograms. Correlation coefficients were used to yield separation between populations of samples coming from the same synthesis batch and samples coming from different batches. It was shown that correlation measurements based on Pearson and cosine functions applied to the data pre-treated by normalisation to the sum of peak responses followed by the square root provided an excellent discrimination between the two populations. The statistical methods applied to organic impurities profiles proved to be excellent techniques to differentiate samples from different batches and to highlight operational links between samples.  相似文献   

2.
Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.  相似文献   

3.
One of the tasks of the European project entitled “Collaborative Harmonisation of Methods for Profiling of Amphetamine Type Stimulants” (CHAMP) funded by the sixth framework programme of the European Commission was to develop a harmonised methodology for MDMA profiling and the creation of a common database in a drug intelligence perspective. Part I was dedicated to the analysis of organic impurities formed during synthesis in order to investigate traffic tendencies and highlight potential links between samples, whereas this part focuses on physical characteristics of the MDMA tablets. Diameter, thickness, weight and score were demonstrated to be reliable and relevant features in this drug intelligence perspective. Distributions of samples coming from the same post-tabletting batch (post-TB) and samples coming from different post-TB were very well discriminated by using the squared Euclidean or the Manhattan distance on standardised data. Our findings demonstrated the possibility to discriminate between MDMA samples issued from different post-TB and to find out links between samples coming from a same post-TB. Furthermore, the hypothesis that most of the MDMA samples found on the international market come from the same countries was supported.  相似文献   

4.
One of the tasks of the European project entitled “Collaborative Harmonisation of Methods for Profiling of Amphetamine Type Stimulants” (CHAMP) funded by the sixth framework programme of the European Commission was to develop a harmonised methodology for MDMA profiling and the creation of a common database in a drug intelligence perspective. Part I was dedicated to the analysis of organic impurities formed during synthesis in order to investigate traffic tendencies and highlight potential links between samples, whereas this part focuses on physical characteristics of the MDMA tablets. Diameter, thickness, weight and score were demonstrated to be reliable and relevant features in this drug intelligence perspective. Distributions of samples coming from the same post-tabletting batch (post-TB) and samples coming from different post-TB were very well discriminated by using the squared Euclidean or the Manhattan distance on standardised data. Our findings demonstrated the possibility to discriminate between MDMA samples issued from different post-TB and to find out links between samples coming from a same post-TB. Furthermore, the hypothesis that most of the MDMA samples found on the international market come from the same countries was supported.  相似文献   

5.
Harmonisation and optimization of analytical and statistical methodologies were carried out between two forensic laboratories (Lausanne, Switzerland and Lyon, France) in order to provide drug intelligence for cross-border cocaine seizures. Part I dealt with the optimization of the analytical method and its robustness. This second part investigates statistical methodologies that will provide reliable comparison of cocaine seizures analysed on two different gas chromatographs interfaced with a flame ionisation detectors (GC-FIDs) in two distinct laboratories. Sixty-six statistical combinations (ten data pre-treatments followed by six different distance measurements and correlation coefficients) were applied. One pre-treatment (N+S: area of each peak is divided by its standard deviation calculated from the whole data set) followed by the Cosine or Pearson correlation coefficients were found to be the best statistical compromise for optimal discrimination of linked and non-linked samples. The centralisation of the analyses in one single laboratory is not a required condition anymore to compare samples seized in different countries. This allows collaboration, but also, jurisdictional control over data.  相似文献   

6.
Solid-phase microextraction (SPME) is a relatively new technique in which a small, polymer-coated fiber is employed to extract volatile and semivolatile organic compounds from the sealed headspace above a questioned sample. SPME, coupled with gas chromatography/mass spectrometry (GC/MS), was used to characterize impurities in illicit methamphetamine samples. Trace impurities present in a specimen were tentatively identified using mass-spectral databases and included 1,2-dimethyl-3-phenyl-aziridine (indicating synthesis via a halogenated ephedrine intermediate), ethyl vanillin (a flavoring compound), and caffeine (a stimulant used as cutting agent). The types and numbers of organic compounds sampled by SPME were compared with those collected by various solvent extraction protocols. In addition to unambiguously confirming the presence of methamphetamine, SPME-GC/MS analyses detected approximately 30 more organic analytes than were found by GC/MS following the ethyl acetate extraction method adopted by the United Nations International Drug Control Programme. SPME-GC/MS is a superior method for generating material "fingerprint" profiles in methamphetamine samples. The detection and characterization of increased points of comparison in drug samples provide more detailed chemical signatures for both intelligence and operational information.  相似文献   

7.
In Hong Kong, ecstasy tablets are more commonly known as "Fing Tau Yuen", literally meaning "Shake Head Pills". The tablets contain mainly amphetamine-type stimulants (ATS) including 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MA) and/or ketamine. Adulterant such as caffeine was also detected in the tablets. This paper reports a study on the impurity profiles of ecstasy tablets from 89 seizures in Hong Kong from 2002 to early 2004. Tablet samples were extracted by diethyl ether under alkaline condition and then analyzed by gas GC-MS. The chromatograms obtained were compared. A total of 19 identified impurities were selected as markers for impurity profiling. They are different precursors, intermediates and by-products. The data matrices were examined by hierarchical cluster analysis (HCA), and then the ecstasy tablets were classified into different groups. Cluster analysis of ecstasy tablets is shown to be capable of providing intelligence on clandestine laboratory networks.  相似文献   

8.
Methamphetamine (MA) tablet production confers chemical and physical properties. This study developed a simple and effective physical characteristic profiling method for MA tablets with capital letter “WY” logos, which realized the discrimination between linked and unlinked seizures. Seventeen signature distances extracted from the “WY” logo were explored as factors for multivariate analysis and demonstrated to be effective to represent the features of tablets in the drug intelligence perspective. Receiver operating characteristic (ROC) curve was used to evaluate efficiency of different pretreatments and distance/correlation metrics, while “Standardization + Euclidean” and “Logarithm + Euclidean” algorithms outperformed the rest. Finally, hierarchical cluster analysis (HCA) was applied to the data set of 200 MA tablet seizures randomly selected from cases all around China in 2015, and 76% of them were classified into a group named after “WY‐001.” Moreover, the “WY‐001” tablets occupied 51–80% tablet seizures from 2011 to 2015 in China, indicating the existence of a huge clandestine factory incessantly manufacturing MA tablets.  相似文献   

9.
The profiling of impurities in methamphetamine (MA) using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) is described. The extraction of the impurities with an SPME fiber was examined under varying conditions. Optimal chromatograms were obtained when a 50 mg MA sample at 85 degrees C for 30 min was extracted using a fiber coated with divinylbenzene/carboxen/polydimethylsiloxane. MA samples from nine different origins were analyzed under optimized extraction conditions. Compounds related to MA such as benzaldehyde, benzyl alcohol, amphetamine, benzyl methyl ketone, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, N-acetylamphetamine, N-acetylmethamphetamine and N-formylmethamphetamine were detected in the chromatograms. Trace amounts of ethanol, diethyl ether and acetic acid were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different, depending on the sample. After the areas of the eight principal peaks were converted to their square root and logarithm, similarities among the samples were evaluated by Euclidian distance, cosine distance and correlation coefficient. The results showed that a combination of logarithmic conversion and cosine distance was the most suitable for discriminating and classifying the samples. HS-SPME/GC-MS is a simple and effective method for the extraction and identification of impurities. The present method, in combination with an appropriate statistical analysis, would be useful for developing a profile of impurities in MA.  相似文献   

10.
Methamphetamine (MA) is one of the most frequently abused drugs worldwide. The aim of this study is to improve the analytical method for profiling MA impurity in order to compare and classify MA crystals seized in different countries and to investigate the relationships between seizures. To compare MA samples seized in Japan and Thailand, the following analytical method was adopted. A 50mg sample of MA.HCl was dissolved in 1ml of buffer solution (four parts 0.1M phosphate buffer, pH 7.0, and one part 10% Na(2)CO(3)), impurities were extracted with 0.5ml of ethyl acetate containing four internal standards (n-decane, n-pentadecane, n-eicosane and n-octacosane) and analyzed by gas chromatography with a flame ionization detector on a DB-5 capillary column (0.32mm i.d.x30m, film thickness 1.0mum). Fourteen characteristic peaks on chromatograms were selected for the comparison and classification of samples, and the data were evaluated by the Euclidean distance of the relative peak areas after logarithmic transformation. Sixty-nine samples seized in Japan and 42 seized in Thailand were analyzed. The samples were classified into four groups roughly by cluster analysis. In addition, when it was difficult to compare samples that had fewer impurities on chromatograms obtained from liquid-liquid extraction (LLE), solid-phase microextraction (SPME) was effective. Because many characteristic peaks were detected using SPME, SPME made it easy to compare samples of high purity. The combination of LLE and SPME was useful for impurity profiling of MA samples seized in different countries.  相似文献   

11.
In this study, a new method was developed for the impurity profiling of illicit MDMA tablets. The extraction efficiency, linearity, repeatability and reproducibility of the method were evaluated. Eighty two MDMA tablets coming from presumed unrelated large seizures in 2004 (n >500 tablets) were analyzed by gas chromatography mass spectrometry (GC-MS) in order to assess the discrimination power of the method. The latter was found to be practical, robust, relatively easy to perform, highly discriminative and yielding good chromatography. In addition, some new impurities were detected and identified. Their chemical structures and mass spectra are reported.  相似文献   

12.
《Science & justice》2014,54(1):32-41
Traditional forensic drug profiling involves numerous analytical techniques, and the whole process is typically costly and may be time consuming. The aim of this study was to investigate the possibility of prioritising techniques utilised at the Australian Federal Police (AFP) for the chemical profiling of 3,4-methylenedioxymethylamphetamine (MDMA). The outcome would provide the AFP with the ability to obtain more timely and valuable results that could be used in an intelligence perspective. Correlation coefficients were used to obtain a similarity degree between a population of linked samples (within seizures) and a population of unlinked samples (between different seizures) and discrimination between the two populations was ultimately achieved. The results showed that gas chromatography–mass spectrometry (GC–MS) was well suited as a single technique to detect links between seizures and could be used in priority for operational intelligence purposes. Furthermore, the method was applied to seizures known or suspected (through their case information) to be linked to each other to assess the chemical similarity between samples. It was found that half of the seizures previously linked by the case number were also linked by the chemical profile. This procedure was also able to highlight links between cases that were previously unsuspected and retrospectively confirmed by circumstantial information. The findings are finally discussed in the broader forensic intelligence context, with a focus on how they could be successfully incorporated into investigations and in an intelligence-led policing perspective in order to understand trafficking markets.  相似文献   

13.
Nineteen crystalline methamphetamine ('ice') seizures captured by the Australian Federal Police (AFP) at the Australian border between 1998 and 2002 were analysed. Using a modified gas chromatograph-mass spectrometry (GC-MS) impurity profiling approach of these samples we have identified >30 compounds associated with methamphetamine and/or its synthetic route. Major impurities detected include 1,2-dimethyl-3-phenylaziridine 8, dimethylamphetamine 14, N-formylmethamphetamine 24, N-acetylmethamphetamine 25, 1,3-dimethyl-2-phenylnaphthalene 32, 1-benzyl-3-methylnaphthalene 33 and methamphetamine dimer 34. These data are suggestive of ephedrine/pseudoephedrine as the main precursor of the 'ice' samples seized during 1998-2002. Additionally the two naphthalenes 32 and 33 further identified that 15 items in 9 seizures were produced via the more specific ephedrine/hydriodic acid/red phosphorus method. One sample comprised 75% dimethylamphetamine and 9.7% methamphetamine, representing the first Australian seizure of imported dimethylamphetamine reported.  相似文献   

14.
Organic impurities of methamphetamine may show different patterns by synthesis. In the present study, we tried to find the impurities reflecting the conditions of synthesis by comparing impurity patterns of the methamphetamine samples synthesized by different methods. Sixteen methamphetamine samples were synthesized from ephedrine and pseudoephedrine by the three different manufacturing methods of Emde, Nagai and Moscow. The synthesized samples were extracted with ethyl acetate containing four internal standards, and the patterns of the organic impurities were investigated by GC-MS and GC-FID . Through the investigation, we found 10 peaks appearing in the latter part of GC chromatograms are characteristic to synthesis. The areas of the selected peaks were converted to the variables suitable for the statistical calculation, and the synthesized samples could be classified into four groups through the resultant cluster analysis.  相似文献   

15.
Improvements in printing technology have exacerbated the problem of document counterfeiting, prompting the need for analytical techniques that better characterize inks for forensic analysis and comparisons. In this study, 319 printing inks (toner, inkjet, offset, and Intaglio) were analyzed directly on the paper substrate using scanning electron microscopy‐energy dispersive spectroscopy (SEM‐EDS) and Laser Ablation‐Inductively Coupled Plasma‐Mass Spectrometry (LA‐ICP‐MS). As anticipated, the high sensitivity of LA‐ICP‐MS pairwise comparisons resulted in excellent discrimination (average of ~ 99.6%) between different ink samples from each of the four ink types and almost 100% correct associations between ink samples known to originate from the same source. SEM‐EDS analysis also resulted in very good discrimination for different toner and intaglio inks (>97%) and 100% correct association for samples from the same source. SEM‐EDS provided complementary information to LA‐ICP‐MS for certain ink types but showed limited utility for the discrimination of inkjet and offset inks.  相似文献   

16.
The present study focused on the stability of 22 amphetamine impurities dissolved in six organic solvents: isooctane, toluene, ethanol, dichloromethane, ethyl acetate, and diethyl ether. The aim was to find the most inert, and thereby most suitable, solvent for amphetamine profiling. Mixtures of the impurities were prepared in the different solvents, and changes in the concentrations of the individual compounds over-time were monitored by gas chromatographic analysis after 0, 4, 12, 24, 48, and 96 h. Isooctane and toluene provided the most inert conditions, although, a few of the impurities were insufficiently stable in these two solvents. The present experiments were performed as a part of the development of a harmonized method for profiling of amphetamine. The results can be used to support the choice of organic solvents for sample preparation. They also provide information about the stability of the impurities that are found in profiles of illicit amphetamine. This is essential due to the fact, that unstable compounds can have a negative influence on the comparison of profiles.  相似文献   

17.
A sexual assault case was received in the laboratory. Upon examination, a small bloodstain was located on a bed sheet that was recovered from the defendant's motel room. Typing the whole blood samples from the defendant and the victim revealed that both blood samples exhibited identical phenotypes in eleven different genetic markers. Gm(1) and Gm(2) analysis was then performed on the two whole blood samples which provided discrimination between the two parties.  相似文献   

18.
Abstract: A genetic database was established with the aim of documenting the genetic diversity of Cannabis sativa in Australia for future utilization in forensic investigations. The database consisted of genotypes at 10 validated short tandem repeat loci for 510 plants representing drug seizures from across Australia and 57 fiber samples. A total of 106 alleles and 314 different genotypes were detected. All fiber samples exhibited unique genotypes while 55% of the drug samples shared a genotype with one or more samples. Shared genotypes were mostly found within seizures; however, some genotypes were found among seizures. Statistical analysis indicated that genotype sharing was a consequence of clonal propagation rather than a lack of genetic resolution. Thus, the finding of shared genotypes among seizures is likely due to either a common supplier, or direct links among seizures. Notwithstanding the potential intelligence information provided by genetic analysis of C. sativa, our database analysis also reveals some present limitations.  相似文献   

19.
Ketamine (KT) is widely abused for hallucination and also misused as a "date-rape" drug in recent years. An analytical method using positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS) with an automatic solid-phase extraction (SPE) apparatus was studied for the determination of KT and its major metabolite, norketamine (NK), in urine. Six ketamine suspected urine samples were provided by the police. For the research of KT metabolism, KT was administered to SD rats by i.p. at a single dose of 5, 10 and 20mg/kg, respectively, and urine samples were collected 24, 48 and 72 h after administration. For the detection of KT and NK, urine samples were extracted on an automatic SPE apparatus (RapidTrace, Zymark) with mixed mode type cartridge, Drug-Clean (200 mg, Alltech). The identification of KT and NK was by PCI-GC-MS. m/z238 (M+1), 220 for KT, m/z 224 (M+1), 207 for NK and m/z307 (M+1) for Cocaine-D(3) as internal standard were extracted from the full-scan mass spectrum and the underlined ions were used for quantitation. Extracted calibration curves were linear from 50 to 1000 ng/mL for KT and NK with correlation coefficients exceeding 0.99. The limit of detection (LOD) was 25 ng/mL for KT and NK. The limit of quantitation (LOQ) was 50 ng/mL for KT and NK. The recoveries of KT and NK at three different concentrations (86, 430 and 860 ng/mL) were 53.1 to 79.7% and 45.7 to 83.0%, respectively. The intra- and inter-day run precisions (CV) for KT and NK were less than 15.0%, and the accuracies (bias) for KT and NK were also less than 15% at the three different concentration levels (86, 430 and 860 ng/mL). The analytical method was also applied to real six KT suspected urine specimens and KT administered rat urines, and the concentrations of KT and NK were determined. Dehydronorketamine (DHNK) was also confirmed in these urine samples, however the concentration of DHNK was not calculated. SPE is simple, and needs less organic solvent than liquid-liquid extraction (LLE), and PCI-GC-MS can offer both qualitative and quantitative information for urinalysis of KT in forensic analysis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号