首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Improvements in detection limits/sensitivity and lower sample consumption are potential benefits of reducing PCR reaction volumes used in forensic DNA typing of crime scene samples. This premise was studied first with experimental mixtures and a nine-loci megaplex, which demonstrated stochiometric amplification and accurate detection. Next, adjudicated casework samples were subjected to amplification under 15 different template DNA to PCR reaction volume ratios. Reduction of PCR reaction volume and DNA down to 10 microL and 0.500 ng, respectively, produced identical profiles with the same signal intensity and heterozygous allele peak height ratio (HR). Reduction to 5 microL and 0.063 ng yielded HR values that were slightly affected in one to three STR loci. PCR reaction volume reduction can enhance detection and sensitivity while reducing the consumption of irreplaceable crime scene samples.  相似文献   

2.
Abstract:  With <100 pg of template DNA, routine short tandem repeat (STR) analysis often fails, resulting in no or partial profiles and increased stochastic effects. To overcome this, some have investigated preamplification methods that include the addition of proofreading enzymes to the PCR cocktail. This project sought to determine whether adding proofreading polymerases directly in the STR amplification mixture would improve the reaction when little template DNA is available. Platinum Taq High Fidelity and GeneAmp High Fidelity were tested in Profiler Plus? STR reactions alone and in combination with AmpliTaq® Gold. All reactions included the additional step of a post‐PCR purification step. With both pristine low template DNA and casework samples, the addition of these polymerases resulted in comparable or no improvement in the STR amplification signal. Further, stochastic effects and artifacts were observed equally across all enzyme conditions. Based on these studies, the addition of these proofreading enzymes to a multiplex STR amplification is not recommended for low template DNA work.  相似文献   

3.
The forensic community continues to seek improvements in DNA typing methods on aspects such as sensitivity and efficacy. Reducing the volume of the AmpFlSTR Profiler Plus reagents offered greater sensitivity and improved the chance of obtaining useful results for samples with very low quantities of DNA and multiple source samples. On the downside, amplifications initiated with less than 0.4 ng of DNA exhibited a twofold increase in the standard deviation of peak ratios. This research suggested a twofold approach to analyzing samples. For samples with greater than 0.25 ng of DNA, a 25 microL reaction is appropriate. Samples that did not demonstrate quantifiable results, or that have less than 0.25 ng, can be amplified by drying the sample directly in the PCR tube and amplifying in a 5 microL reaction. The analyst can expect at least limited results with as little as 0.03 ng of DNA in the 5 microL reaction.  相似文献   

4.
Laboratory procedures used in short tandem repeat (STR) analysis were subjected to various scenarios that assessed reliability and identified potential limitations. These validation studies were designed as recommended by the Technical Working Group on DNA Analysis Methods (TWGDAM) and the DNA Advisory Board (DAB) (17,18). Various DNA samples were amplified by the polymerase chain reaction (PCR) using AmpFlSTR PCR Amplification Kits (i.e., AmpFlSTR Green I, Profiler, Profiler Plus, and COfiler kits), detected with ABI Prism instrumentation, and analyzed using GeneScan and Genotyper software. Data acquired in these studies reinforced an existing body of knowledge and expertise regarding application and interpretation of STR typing in the forensic science community. Consistent STR genotypes were detected in various body tissues and fluids. Inter-laboratory comparisons produced concordant genotype results. Quantitative interpretational aids for DNA mixtures were characterized. Ability of the typing systems to type potentially compromised samples reliably was evaluated. Nonprobative case evidentiary DNA was successfully amplified, genotyped, and interpreted. Potential limitations or cautionary factors in the interpretation of minimal fluorescence intensity were demonstrated. Differential amplification between loci was observed when PCR was inhibited; preferential amplification typically was not. Single AmpFlSTR locus amplification did not offer consistent benefit over AmpFlSTR multiplexing, even in cases of DNA degradation or PCR inhibition. During rigorous evaluation, AmpFlSTR PCR Amplification Kits reproducibly yielded sensitive and locus-specific results, as required in routine forensic analyses.  相似文献   

5.
An approach for generating DNA profiles when critical samples have been consumed and a power outage occurs during the polymerase chain reaction (PCR) amplification reaction is described. This study demonstrates that a complete and accurate DNA short tandem repeat profile can be obtained: (1) when single source DNA samples are amplified for 26, 27, or 28 cycles using the Profiler Plus and COfiler Amplification Kits after an interruption in amplification, (2) from mock samples when PCR amplification has been interrupted early (after five cycles) or late (after 18 cycles) and the sample is subjected to an additional round of amplification, even after incubation of the sample at room temperature overnight, and (3) from nonprobative casework samples interrupted after approximately 18 cycles of amplification, an overnight incubation at room temperature and subjected to one or two additional rounds of PCR amplification for approximately 26 total cycles. Samples interrupted before five completed cycles and subjected to additional PCR cycles yielded variable results.  相似文献   

6.
Human stool samples from eight volunteers were stored under various conditions and extracted by three different procedures. Fecal material and tissue paper soiled with fecal material obtained from a crime scene were also extracted. Extracted DNA was amplified using the AmpFlSTR Profiler Plus, AmpFlSTR COfiler, and the AmpFlSTR Identifiler PCR amplification kits for the detection of the autosomal STR allelic patterns. DNA extracted from the male volunteers and from the soiled tissue paper evidence sample was also amplified using the Y-PLEX 6 and Y-PLEX 5 amplification kits. Analysis of the amplified products was carried out by capillary electrophoresis on the ABI PRISM 310 Genetic Analyzer. Autosomal and Y-STR profiles obtained from the fecal material were concordant with the results from the donors' buccal swabs.  相似文献   

7.
The performance of two commercial multiplex kits that together amplify the 13 core short tandem repeat (STR) loci currently in use by forensic laboratories and the U.S. national Combined DNA Indexing System (CODIS) were evaluated. The typing systems examined were AmpFlSTR Profiler Plus and AmpFlSTR COfiler (PE Applied Biosystems, Foster City, CA). Electrophoretic separation and detection of the fluorescent PCR products was achieved by capillary electrophoresis (CE) using an ABI Prism 310 Genetic Analyzer. The studies addressed the on-site validation of the instrument, the software, and each typing system. These studies included instrument sensitivity, resolution, precision, binning, peak height ratios, mixtures, stutter, and the amplification of non-probative and simulated forensic samples. Other additional developmental-type work is also reported herein, such as species specificity testing and amplification of environmentally insulted samples. Amplification conditions were found to be robust and the primer sets shown to be specific to human DNA. Stutter and peak height ratios fell within limits published by the manufacturer and other laboratories. The data demonstrate that the CE instrument can consistently resolve fragments differing in length by one base and that the +/-0.5 base bin used by the Genotyper software is acceptable for making accurate allele calls. Correct typing results were obtained from non-probative and simulated case samples, as well as samples exposed to outdoor environmental conditions. The results support the conclusion that DNA extracted from biological samples routinely encountered in the forensic laboratory can be reliably analyzed with AmpFlSTR Profiler Plus and COfiler using CE.  相似文献   

8.
A feasibility study of short tandem repeat (STR) genotyping of telogen phase hairs in particular, and hair shaft in general, is presented. A number of extraction procedures in common use were investigated and the quantities of nuclear DNA (nuDNA) delivered were quantified via a real-time PCR assay. The extracts were subjected to two variations on AmpFlSTR Profiler Plus PCR amplification strategies (extended cycles, two rounds of PCR) and the genotypes compared. Nuclear DNA was found to persist in human hair shafts, albeit at very low levels. Full Profiler Plus profiles consistent with the hair donor were obtained from 100 mg hair shaft samples (bleached and unbleached). These were, however, mixed profiles, indicating low copy number (LCN) contamination in the extracts. Single telogen hair clubs and single hair shafts delivered partial profiles with usually only one allele of heterozygous loci. Telogen phase hairs yielded the same amount of nuDNA (and no more) as hair shafts (either anagen or telogen). Whether hair shafts dissolved or not in lysis buffer had no effect on either the quantitated yield of DNA or on the chance of obtaining a correct genotype. These results provide evidence that genomic DNA resides on the exterior of the hair shaft and we use this information to suggest an optimal procedure for nuDNA extraction from keratinised hair samples: soaking hairs in simple digestion buffers containing Tris-HCl, a salt and a chelating agent without prior cleaning of the hair shafts. It is proposed that cleaning removes most of the recoverable DNA. This procedure was applied to obtain genotypes from 3 cm hair shafts which matched reference profiles from the donors at up to 9 out of 10 AmpFlSTR Profiler Plus STR loci. When the genotyping success was measured by counting the number of matches between the two dominant alleles at each locus for each extract with the reference DNA profile of the hair donor, the success was found to be highly dependent on the donor. The number of matching alleles varied between not less than 10 for one donor to no more than two for another donor. These results may well be linked to the environmental experience of the hairs from each donor prior to removal.  相似文献   

9.
DNA typing of degraded DNA samples can be a challenging task when using the current commercially available multiplex short tandem repeat (STR) analysis kits. However, the ability to type degraded DNA specimens improves by redesigning current STR marker amplicons such that smaller sized polymerase chain reaction (PCR) products are generated. In an effort to increase the amount of information derived from these types of DNA samples, the AmpFlSTR MiniFiler PCR Amplification Kit has been developed. The kit contains reagents for the amplification of eight miniSTRs which are the largest sized loci in the AmpFlSTR Identifiler PCR Amplification Kit (D7S820, D13S317, D16S539, D21S11, D2S1338, D18S51, CSF1PO, and FGA). Five of these STR loci (D16S539, D21S11, D2S1338, D18S51, and FGA) also are some of the largest loci in the AmpFlSTR SGM Plus kit. This informative nine-locus multiplex, which includes the gender-identification locus Amelogenin, has been validated according to the FBI/National Standards and SWGDAM guidelines. Our results demonstrate significant performance improvements in models of DNA degradation, PCR inhibition, and nonprobative samples when compared to the AmpFlSTR Identifiler and SGM Plus kits. These data support that the MiniFiler kit will increase the likelihood of obtaining additional STR information from forensic samples in situations in which standard STR chemistries fail to produce complete profiles.  相似文献   

10.
A 96-channel microfabricated capillary array electrophoresis (muCAE) device was evaluated for forensic short tandem repeat (STR) typing using PowerPlex 16 and AmpFlSTR Profiler Plus multiplex PCR systems. The high-throughput muCAE system produced high-speed <30-min parallel sample separations with single-base resolution. Forty-eight previously analyzed single-source samples were accurately typed, as confirmed on an ABI Prism 310 and/or the Hitachi FMBIO II. Minor alleles in 3:1 mixture samples containing female and male DNA were reliably typed as well. The instrument produced full profiles from sample DNA down to 0.17 ng, a threshold similar to that found for the ABI 310. Seventeen nonprobative samples from various evidentiary biological stains were also correctly typed. The successful application of the muCAE device to actual forensic STR typing samples is a significant step toward the development of a completely integrated STR analysis microdevice.  相似文献   

11.
To assist the interpretation of STR DNA typing results from forensic casework samples containing mixtures, the range of heterozygous allele peak height and peak area ratios (HR) and stutter percentages (stutter %) for the loci comprised in the AmpFlSTR Profiler Plus (PP) kit were assessed on 468 database and 275 casework single source samples. Stutter % medians were similar for database and casework samples, ranging from 2% to 7%. The upper limit of the stutter value range was 16%, calculated as median +3 SD, although lower locus-specific values could be used. HR medians were 93 +/- 6.5% for database samples, 88 +/- 12% for casework samples. For casework samples, the maximum signal imbalance noted was 52%, calculated as median -3 SD. No significant difference was observed between peak height and peak area calculated values. This study shows the importance of selecting the proper reference database for the establishment of HR threshold values.  相似文献   

12.
A preliminary study was conducted to assess the capability of a new alcohol-based tissue fixative, GenoFix, to preserve DNA from biopsy tissues stored at room temperature and/or -20 degrees C in a freezer, for subsequent short tandem repeat (STR) DNA typing analysis. Fresh human smooth muscle samples were stored at room temperature in GenoFix for one month and up to one year and seven months before being processed using the megaplex STR systems, AmpFlSTR Profiler Plus and AmpFlSTR COfiler. Alternatively, muscle tissues in GenoFix were placed at -20 degrees C in a freezer for up to 3 1/2 years following two to three months in the fixative at room temperature. DNA analysis was also carried out on tissues stored in GenoFix for one month at room temperature and subsequently paraffin-embedded and stored at room temperature for four years. The AmpFlSTR Profiler Plus and AmpFlSTR COfiler STR profiles produced, using DNA extracted from all fixed tissue samples, were of very good quality. The fluorescent signals were well balanced across the nine STR loci or six loci comprised in the megaplexes surveyed and profiles showed no differences with those observed for the control blood of the respective donor patients. Continuous exposure to GenoFix at room temperature (up to one year and seven months) did not compromise the STR typing analysis of the fixed tissues. No adverse effects were noted on the STR typeability of tissues fixed with GenoFix and stored at -20 degrees C in a freezer for up to 3 1/2 years. STR profiles generated from the paraffin-embedded tissues fixed in GenoFix were of excellent quality. This preliminary study suggests that GenoFix can be used to store tissue samples at room temperature for up to one year and seven months or at -20 degrees C in a freezer for longer storage (up to 3 1/2 years). This new and odorless tissue fixative promotes tissue and DNA preservation in a very effective manner and as such may prove useful in criminal investigations or mass disaster identifications carried out in remote locations and in which a small or large number of tissue samples are collected for further analyses.  相似文献   

13.
A population study of Chamorros and Filipinos using short tandem repeat (STR) loci amplified with the AmpFlSTR Profiler Plus PCR amplification kit demonstrated an excess of observed homozygosity at the D8S1179 locus. Use of a different set of D8S1179 primers to type the same samples did not demonstrate an excess of homozygosity and showed discordant genotypes at the D8S1179 locus. A single point mutation, G-to-A transition, 16 nucleotides from the 3' end of the reverse primer, was identified to cause allele dropout when using the AmpFlSTR Profiler Plus primer set. An additional D8S1179 reverse primer specific for the variant was constructed resulting in the recovery of the null allele. The primer was included in the newly developed AmpFlSTR Identifiler PCR amplification kit. No deleterious effects or non-specific peaks were observed in validation experiments evaluating primer concentration, Mg2+ concentration, annealing temperature and population samples.  相似文献   

14.
Abstract:  Evidentiary traces may contain low quantities of DNA, and regularly incomplete short tandem repeat (STR) profiles are obtained. In this study, higher capillary electrophoresis injection settings were used to efficiently improve incomplete STR profiles generated from low-level DNA samples under standard polymerase chain reaction (PCR) conditions. The method involves capillary electrophoresis with higher injection voltage and extended injection time. STR peak heights increased six-fold. Inherent to the analysis of low-level DNA samples, we observed stochastic amplification artifacts, mainly in the form of allele dropout and heterozygous peak imbalance. Increased stutter ratios and allele drop-in were rarely seen. Upon STR typing of 10:1 admixed samples, the profile of the major component did not become overloaded when using higher injection settings as was observed upon elevated cycling. Thereby an improved profile of the minor component was obtained. For low-level DNA casework samples, we adhere to independent replication of the PCR amplification and boosted capillary electrophoresis.  相似文献   

15.
Fingerprinting brushes have the potential to collect and transfer DNA during powdering. Squirrel-hair fingerprint brushes exposed to specific sets of saliva stains and brushes used in routine casework were tested for their ability to collect and transfer DNA containing material using standard DNA extraction procedures and AmpFlSTR Profiler Plus amplification and typing procedures. The tests found that the risk of transferring DNA during powdering and having a detrimental impact on the analysis increases if the examiner powders over either biological stains (such as blood or saliva) or very fresh prints and uses more sensitive PCR amplification and typing procedures. We advocate caution when powdering prints from which DNA may also be collected and provide options for consideration to limit the risk of transferred DNA contamination while fingerprinting.  相似文献   

16.
A method for genomic DNA recovery from different types of PCR product mixes suitable for multiplex amplification and typing using the Profiler Plus STR typing system has been investigated. The application of this method is of significance in cases where the original DNA samples have been exhausted due to repeated typing analyses in an effort to maximize their evidentiary value. Such cases typically involve samples analyzed using the available DNA typing systems of the time which gave a markedly lower power of discrimination, either alone or in combination, compared to that of modern multiplex STR typing systems. It was found that an effective method for recovering genomic DNA from HLA-DQA1 +PM and CTT triplex amplification mixes, suitable for reproducible achievement of the complete Profiler Plus profile, involved the use of Amicon Microcon-100 microconcentrators. Interestingly, this method was not required to achieve the complete nine STR profile using D1S80 amplification mixes.  相似文献   

17.
Prior to forensic implementation, a profiling system requires validation following the recommendations presented by the Technical Working Group on DNA Analysis Methods (TWGDAM). In this work two such systems, AmpFlSTR Profiler Plus and AmpFfSTR COfiler have been validated according to the guidelines provided by TWGDAM. Profiler Plus and COfiler simultaneously amplify nine and six STR loci respectively; both also amplify a portion of the amelogenin gene. Performance of the two STR multiplex systems under conditions set forth by TWGDAM was robust and reproducible, indicating that these systems are suitable for use in forensic analysis. Additionally, specific sections of the TWGDAM validation guidelines are especially valuable in terms of familiarizing users with particular limitations of the systems prior to taking on casework.  相似文献   

18.
The use of the polymerase chain reaction (PCR) to define deoxyribonucleic acid (DNA) types at several loci was investigated. PCR was used to amplify nine short tandem repeat (STR) loci along with the amelogenin locus on the X and Y chromosomes using the AmpF/STR Profiler Plus PCR amplification kit (Perkin Elmer). Rib bones were collected from 12 individuals. Five cm portions were buried at a depth of approximately 30 cm and 5 cm portions were left on the surface of the ground. Samples were exposed to the environment for periods of time ranging from two weeks to 17 months. Dried blood standards were prepared for use as reference standards for each rib sample. Bone, muscle, and bone marrow were collected from each sample. DNA from each tissue type was extracted. Complete profile results were obtained from the surface bone samples out to an exposure time of 17 months. None of the muscle or bone marrow samples produced complete profile results beyond eight weeks. All DNA typing results from complete or incomplete profiles were consistent with DNA typing results of the corresponding blood standard. Results suggest that using the AmpF/STR Profiler Plus PCR Amplification Kit is a valid way to establish the DNA profile of tissue types from human remains.  相似文献   

19.
The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.  相似文献   

20.
Abstract:  The time required for short tandem repeat (STR) amplification is determined by the temperature ramp rates of the thermal cycler, the components of the reaction mix, and the properties of the reaction vessel. Multiplex amplifications in microfluidic biochip-based and conventional tube-based thermal cyclers have been demonstrated in 17.3 and 19 min, respectively. Optimized 28-cycle amplification protocols generated alleles with signal strengths above calling thresholds, heterozygous peak height ratios of greater than 0.65, and incomplete nontemplate nucleotide addition and stutter of less than 15%. Full CODIS-compatible profiles were generated using the Profiler Plus ID, COfiler and Identifiler primer sets. PCR performance over a wide range of DNA template levels from 0.006 to 4 ng was characterized by separation and detection on a microfluidic electrophoresis system, Genebench-FX. The fast multiplex PCR approach has the potential to reduce process time and cost for STR analysis and enables development of a fully integrated microfluidic forensic DNA analysis system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号