首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The use of amphetamine and 'ecstasy' (MDMA) has increased exponentially in many European countries since the late nineties, leading to a rapid growth in the number of clinical and forensic analyses. Therefore, a rapid screening procedure for these substances in biological specimens has become an important part of routine toxicological analysis in forensic laboratories. The objective of this study was to evaluate the Cozart amphetamine enzyme-linked immunosorbent assay (ELISA) for the screening of plasma samples and oral fluid samples (collected with the Intercept device). Authentic plasma samples from drivers (n=360) were screened, using an 1:5-fold dilution. True positive, true negative, false positive and false negative results were determined relative to the in-house routine GC-MS analysis. Samples consisted of 144 amphetamine-only positives, 141MDMA/MDA-only positives, and 74 negatives when using the limit of quantitation as the cut-off level for confirmation (10 ng/mL). Using these results, receiver operating characteristic (ROC) curves were generated and optimal cut-off values for the screening assay were calculated. Analysis showed that the ELISA is able to predict the presence of either amphetamine or *MDMA/MDA (*MDMA as its metabolite MDA) in plasma samples with 98.3% sensitivity and 100% specificity at a cut-off value of 66.5 ng/mL d-amphetamine equivalents. A similar analysis was conducted on 216 oral fluid specimens collected from a controlled double blind study. Subjects received placebo or a high (100 mg) or low (75 mg) dose of MDMA. Oral fluid samples were collected at 1.5 and 5.5h after administration. Combined results of the analysis of the high and low dose oral fluid samples indicated a screening cut-off of 51 ng/mL d-amphetamine equivalents with both a sensitivity and specificity of 98.6% (using a LC-MS/MS confirmation cut-off of 10 ng/mL). In conclusion, these data indicate that the Cozart AMP EIA plates constitute a fast and accurate screening technique for the identification of amphetamine and MDMA/MDA positive plasma samples and oral fluid specimens (collected with Intercept. It should be emphasized that method validation should be performed for each type of biological matrix.  相似文献   

2.
A controlled study was undertaken to determine the stability of the designer drugs MDA, MDMA and MDEA in pooled serum, whole blood, water and urine samples over a period of 21 weeks. The concentrations of the individual designer drugs in the various matrices were monitored over time, in the dark at various temperatures (-20, 4 or 20 degrees C), for a low (+/- 6 ng/ml for water, serum and whole blood and +/- 150 ng/ml for urine) and a high concentration level (+/- 550 ng/ml for water, serum and whole blood and +/- 2500 ng/ml for urine). Compound concentrations were measured using a validated HPLC assay with fluorescence detection. Our study demonstrated no significant loss of the designer drugs in water and urine at any of the investigated temperatures for 21 weeks. The same results were observed in serum for up to 17 weeks, and up to 5 weeks in whole blood. After that time, the compounds could no longer be analyzed due to matrix degradation, especially in the low concentration samples that were stored at room temperature. This study demonstrates that the designer drugs, MDA, MDMA and MDEA are stable when stored at -20 degrees C for 21 weeks, even in haemolysed whole blood.  相似文献   

3.
The aim of this study was to assess the effectiveness of two current on-site oral fluid (OF) drug detection devices (OraLab and Dr?ger), as part of the Spanish participation in the Roadside Testing Assessment Project (ROSITA Project). The study was done in collaboration with the Spanish Traffic Police, in Galicia (NW Spain), during 2004 and 2005. A total of 468 drivers selected at the police controls agreed to participate through informed consent. In addition, saliva samples were collected and sent to the laboratory to confirm the on-site results. For this purpose, two different analytical liquid chromatography-mass spectrometry (LC-MS) methods were used to detect 11 drugs or metabolites in a 300 microL sample. Simultaneous analysis of morphine, 6-acetylmorphine, amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB, cocaine and benzoylecgonine was carried out using 100 microL of oral fluid, after an automated solid phase extraction. A different LC-MS method was performed to detect Delta(9)-THC in 200 microL of oral fluid using liquid-liquid extraction with hexane at pH 6. Both methods were fully validated, including linearity (1-250 ng/mL, 2-250 ng/mL) recovery (>50%), within-day and between-day precision (CV<15%), accuracy (mean relative error<15%), limit of detection (0.5 and 1 ng/mL), quantitation (1 and 2 ng/mL) and matrix effect. All of the positive cases and a random selection of 30% of the negatives were analyzed for confirmation analysis. Good results (sensitivity, specificity, accuracy, positive predictive value and negative predictive value>90%) were obtained for cocaine and opiates by OraLab, and for cocaine by Dr?ger. However, the results for the other compounds could be improved for both detection devices. Differences in the ease of use and in the interpretation mode (visual or instrumental) were observed.  相似文献   

4.
Identification of 6-acetylmorphine, a specific metabolite of heroin, is considered to be definitive evidence of heroin use. Although 6-acetylmorphine has been identified in oral fluid following controlled heroin administration, no prevalence data is available for oral fluid specimens collected in the workplace. We evaluated the prevalence of positive test results for 6-acetylmorphine in 77,218 oral fluid specimens collected over a 10-month period (January-October 2001) from private workplace testing programs. Specimens were analyzed by Intercept immunoassay (cutoff concentration=30 ng/ml) and confirmed by GC-MS-MS (cutoff concentrations=30 ng/ml for morphine and codeine, and 3 ng/ml for 6-acetylmorphine). Only morphine-positive oral fluid specimens were tested by GC-MS-MS for 6-acetylmorphine. A total of 48 confirmed positive morphine results were identified. An additional 107 specimens were confirmed for codeine only. Of the 48 morphine-positive specimens, 32 (66.7%) specimens were positive for 6-acetylmorphine. Mean concentrations (+/-S.E.M.) of morphine, 6-acetylmorphine and codeine in the 32 specimens were 755+/-201, 416+/-168 and 196+/-36 ng/ml, respectively. Concentrations of 6-acetylmorphine in oral fluid ranged from 3 to 4095 ng/ml. The mean ratio (+/-S.E.M.) of 6-acetylmorphine/morphine was 0.33+/-0.06. It is suggested that, based on controlled dose studies of heroin administration, ratios >1 of 6-acetylmorphine/morphine in oral fluid are consistent with heroin use within the last hour before specimen collection. The confirmation of 6-acetylmorphine in 66.7% of morphine-positive oral fluid specimens indicates that oral fluid testing for opioids may offer advantages over urine in workplace drug testing programs and in testing drugged drivers for recent heroin use.  相似文献   

5.
There were 13,176 roadside drug tests performed in the first year of the random drug-testing program conducted in the state of Victoria. Drugs targeted in the testing were methamphetamines and Δ9-tetrahydrocannabinol (THC). On-site screening was conducted by the police using DrugWipe®, while the driver was still in the vehicle and if positive, a second test on collected oral fluid, using the Rapiscan®, was performed in a specially outfitted “drug bus” located adjacent to the testing area. Oral fluid on presumptive positive cases was sent to the laboratory for confirmation with limits of quantification of 5, 5, and 2 ng/mL for methamphetamine (MA), methylenedioxy-methamphetamine (MDMA), and THC, respectively. Recovery experiments conducted in the laboratory showed quantitative recovery of analytes from the collector. When oral fluid could not be collected, blood was taken from the driver and sent to the laboratory for confirmation. These roadside tests gave 313 positive cases following GC–MS confirmation. These comprised 269, 118, and 87 cases positive to MA, MDMA, and THC, respectively. The median oral concentrations (undiluted) of MA, MDMA, and THC was 1136, 2724, and 81 ng/mL. The overall drug positive rate was 2.4% of the screened population. This rate was highest in drivers of cars (2.8%). The average age of drivers detected with a positive drug reading was 28 years. Large vehicle (trucks over 4.5 t) drivers were older; on average at 38 years. Females accounted for 19% of all positives, although none of the positive truck drivers were female. There was one false positive to cannabis when the results of both on-site devices were considered and four to methamphetamines.  相似文献   

6.
A rapid and sensitive method using LC-MS/MS triple stage quadrupole for the determination of traces of amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA, "ecstasy"), 3,4-methylenedioxyethamphetamine (MDEA), and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in hair, blood and urine has been developed and validated. Chromatography was carried out on an Uptisphere ODB C(18) 5 microm, 2.1 mm x 150 mm column (Interchim, France) with a gradient of acetonitrile and formate 2 mM pH 3.0 buffer. Urine and blood were extracted with Toxitube A (Varian, France). Segmented scalp hair was treated by incubation 15 min at 80 degrees C in NaOH 1M before liquid-liquid extraction with hexane/ethyl acetate (2/1, v/v). The limits of quantification (LOQ) in blood and urine were at 0.1 ng/mL for all analytes. In hair, LOQ was <5 pg/mg for MA, MDMA, MDEA and MBDB, at 14.7 pg/mg for AP and 15.7 pg/mg for MDA. Calibration curves were linear in the range 0.1-50 ng/mL in blood and urine; in the range 5-500 pg/mg for MA, MDMA, MDEA and MBDB, and 20-500 pg/mg for AP and MDA. Inter-day precisions were <13% for all analytes in all matrices. Accuracy was <20% in blood and urine at 1 and 50 ng/mL and <10% in hair at 20 and 250 pg/mg. This method was applied to the determination of MDMA in a forensic case of single administration of ecstasy to a 16-year-old female without her knowledge during a party. She suffered from hyperactivity, sweating and agitation. A first sample of urine was collected a few hours after (T+12h) and tested positive to amphetamines by immunoassay by a clinical laboratory. Blood and urine were sampled for forensic purposes at day 8 (D+8) and scalp hair at day 60 (D+60). No MDMA was detected in blood, but urine and hair were tested positive, respectively at 0.42 ng/mL and at 22 pg/mg in hair only in the segment corresponding to the period of the offence, while no MDA was detectable. This method allows the detection of MDMA up to 8 days in urine after single intake.  相似文献   

7.
The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the Cozart Amphetamine Microplate EIA and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart Amphetamine Microplate EIA for amphetamine in oral fluid over forty assays was 2.74-7.1% CV (within assay) and 3.4-7.0% CV (within day). A total of 78 samples were positive for various amphetamines and related designer drugs. The Cozart Amphetamine Microplate EIA, using a cutoff of 45 ng/ml amphetamine equivalents in neat oral fluid, had a sensitivity of 91.7+/-3.3% and a specificity of 95.9+/-1.9% versus GC-MS using a cutoff of 30 ng/ml. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

8.
The U.S. Department of Health and Human Services (HHS) drug testing standards were published in 1988 and revised in 1994, 1998, and 2004. In 2004, significant revisions defining, standardizing, and requiring specimen validity testing on Federal employee donor urine specimens were included. In a separate notice, HHS proposed to establish scientific and technical guidelines for the Federal Workplace Drug Testing Program to: (1) permit laboratory testing of hair, oral fluid, and sweat patch specimens in addition to urine specimens for marijuana, cocaine, phencyclidine, opiates (with focus on heroin), and amphetamines [including methylenedioxymethamphetamine (MDMA), methylenedioxyethamphetamine (MDEA), methylenedioxyamphetamine (MDA)]; (2) permit use of on-site point of collection test (POCT) devices to test urine and oral fluid at collection sites; (3) permit use of instrumented initial test (screening only) facilities [IITF] to quickly identify negative specimens; and (4) add training requirement for collectors, on-site testers, and MROs. This proposal was published in the Federal Register on 13 April 2004, with a 90-day public comment period. The Substance Abuse and Mental Health Services Administration, HHS, reviewed those comments and is preparing the Final Notice that will define the requirements for such testing, including: specimen collection procedures, custody and control procedures that ensure donor specimen identity and integrity, testing facility, initial and confirmatory test cutoff concentrations, analytical testing methods, result review and reporting, evaluation of alternative medical explanations for presence of drug or metabolite in the donor's specimen, and laboratory certification issues. Voluntary pilot performance testing (PT) programs for each specimen type are on-going since April 2000 to determine how to prepare PT materials for specimens other than urine to evaluate laboratories' ability to routinely achieve accuracy and precision required. Certification programs will be developed using the current urine drug testing National Laboratory Certification Program model. The addition of accurate and reliable workplace drug testing using hair, oral fluid, and sweat patch specimens will complement urine drug testing, and aid in combating industries devoted to suborning drug testing through adulteration, substitution, and dilution. For example, hair testing may detect chronic drug use for up to 90 days and be useful in pre-employment situations; oral fluid testing may detect drug use in past hours and be useful in post-accident situations; sweat patch testing may be useful in follow-up drug testing and treatment programs; POCTs and IITFs may be most useful for quickly identifying specimens that are negative for drugs and indicate that the specimen is valid.  相似文献   

9.
We present a validated method for the simultaneous analysis of basic drugs which comprises a sample clean-up step, using mixed-mode solid-phase extraction (SPE), followed by LC-MS/MS analysis. Deuterated analogues for all of the analytes of interest were used for quantitation. The applied HPLC gradient ensured the elution of all the drugs examined within 14 min and produced chromatographic peaks of acceptable symmetry. Selectivity of the method was achieved by a combination of retention time, and two precursor-product ion transitions for the non-deuterated analogues. Oral fluid was collected with the Intercept, a FDA approved sampling device that is used on a large scale in the US for workplace drug testing. However, this collection system contains some ingredients (stabilizers and preservatives) that can cause substantial interferences, e.g. ion suppression or enhancement during LC-MS/MS analysis, in the absence of suitable sample pre-treatment. The use of the SPE was demonstrated to be highly effective and led to significant decreases in the interferences. Extraction was found to be both reproducible and efficient with recoveries >76% for all of the analytes. Furthermore, the processed samples were demonstrated to be stable for 48 h, except for cocaine and benzoylecgonine, where a slight negative trend was observed, but did not compromise the quantitation. In all cases the method was linear over the range investigated (2-200 microg/L) with an excellent intra-assay and inter-assay precision (coefficients of variation <10% in most cases) for QC samples spiked at a concentration of 4, 12 and 100 microg/L. Limits of quantitation were estimated to be at 2 microg/L with limits of detection ranging from 0.2 to 0.5 microg/L, which meets the requirements of SAMHSA for oral fluid testing in the workplace. The method was subsequently applied to the analysis of Intercept samples collected at the roadside by the police, and to determine MDMA and MDA levels in oral fluid samples from a controlled study.  相似文献   

10.
The purpose of this study was to determine the performance characteristics of the Cozart microplate EIA for detecting opiates in oral fluid from patients in a drug misuse treatment program. Oral fluid samples were collected using the Cozart RapiScan Collection System from 216 donors who were receiving treatment for their addiction and were monitored for drug abuse. A further 40 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory by using the Cozart microplate EIA for opiates and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart microplate oral fluid EIA for opiates over 40 assays was 0.43% to 9.13% CV (within assay) and 2.9% to 9.1% CV (within day). A total of 109 samples were positive for various opiates. The Cozart microplate EIA for opiates in oral fluid, using a cut-off of 30 ng/ml morphine equivalents in neat oral fluid, had a sensitivity of 99.1 +/- 2.1% and a specificity of 94.4 +/- 2.2% versus GC-MS. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.  相似文献   

11.
There is no toxicological analysis of gamma-hydroxybutyrate (GHB) applied routinely in cases of driving under influence (DUI); therefore the extent of consumption of this drug might be underestimated. Its consumption is described as occurring often concurrently with amphetamine or ecstasy. This study examines 196 serum samples which were collected by police during road side testing for GHB. The samples subject to this study have already been found to be positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDEA). Analysis has been performed by LC/MS/MS in the multiple reaction monitoring (MRM) mode. Due to its polarity, chromatographic separation of GHB was achieved by a HILIC column. To differentiate endogenous and exogenous levels of GHB, a cut-off concentration of 4μg/ml was applied. Of the 196 samples, two have been found to be positive for GHB. Of these samples, one sample was also positive for amphetamine and one for MDMA. Whilst other amphetamine derivates were not detected in these samples, both samples were found to be positive for cannabinoids. These results suggest that co-consumption of GHB with amphetamine or ecstasy is relatively low (1%) for the collective of this study.  相似文献   

12.
Hair of young subjects (N = 36) suspected for drug abuse was analysed for morphine, codeine, heroin, 6-acetylmorphine, cocaine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA). The analysis of morphine, codeine, heroin, 6-acetylmorphine, cocaine, and methadone in hair included incubation in methanol, solid-phase extraction, derivatisation by the mixture of propionic acid anhydride and pyridine, and gas chromatography/mass spectrometry (GC/MS). For amphetamine, methamphetamine, MDA, MDMA, and MDEA analysis, hair samples were incubated in 1M sodium hydroxide, extracted with ethyl acetate, derivatised with heptafluorobutyric acid anhydride (HFBA), and assayed by GC/MS. The methods were reproducible (R.S.D. = 5.0-16.1%), accurate (85.1-100.6%), and sensitive (LoD = 0.05-0.30ng/mg). The applied methods confirmed consumption of heroin in 18 subjects based on positive 6-acetylmorphine. Among these 18 heroin consumers, methadone was found in four, MDMA in two, and cocaine in two subjects. Cocaine only was present in two, methadone only in two, methamphetamine only in two, and MDMA only in seven of the 36 subjects. In two out of nine coloured and bleached hair samples, no drug was found. Despite the small number of subjects, this study has been able to indicate the trend in drug abuse among young people in Croatia.  相似文献   

13.
A fast method was designed for the simultaneous determination of amphetamine (A), methamphetamine (MA), PMA, MDA, MDMA, MDEA and MBDB in urine. The drugs were analysed by LC (ESI)-MS/MS, after a simple liquid-liquid extraction in the presence of the deuterated analogues. Reverse phase separation on an Atlantis dC18 Intelligent Speed column was achieved in less than 4 min under gradient conditions, and the total run time was 8 min. The method was fully validated, including linearity (1-1000 ng/mL for A, MDMA, MDEA and MBDB; 2-1000 ng/mL for MDA and PMA; 1-200 ng/mL for MA; r2>0.99 for all compounds), recovery (>80%), within-day and between-day precision and accuracy (CV and MRE<12.7% for intermediate level and ULOQ, and <17.2% for LLOQ), limit of detection (0.2 ng/mL for MDMA, MDEA and MBDB; 0.5 ng/mL for A, MA and PMA; 1 ng/mL for MDA) and quantitation (1 ng/mL for A, MA, MDMA, MDEA and MBDB; 2 ng/mL for MDA and PMA) and relative ion intensities. No matrix effect was observed. The procedure proved to be sensitive, specific and rapid, and was applied to real forensic cases.  相似文献   

14.
An analytical method using solid-phase extraction (SPE) and high-performance liquid chromatography-mass spectrometry (LC-MS) has been developed and validated for the confirmation of Delta(9)-tetrahydrocannabinol (THC) in oral fluid samples. Oral fluid was extracted using Bond Elut LRC-Certify solid-phase extraction columns (10 cm(3), 300 mg) and elution performed with n-hexane/ethyl acetate. Quantitation made use of the selected ion-recording mode (SIR) using the most abundant characteristic ion [THC+H(+)], m/z 315.31 and the fragment ion, m/z 193.13 for confirmation, and m/z 318.00 for the protonated internal standard, [d(3)-THC+H(+)]. The method proved to be precise for THC, in terms of both intra-day and inter-day analyses, with coefficients of variation less than 10%, and the calculated extraction efficiencies for THC ranged from 76 to 83%. Calibration standards spiked with THC between 2 and 100 ng/mL showed a linear relationship (r(2)=0.999). The method presented was applied to the oral fluid samples taken from the volunteers during the largest music event in Portugal, named Rock in Rio-Lisboa. Oral fluid was collected from 40 persons by expectoration and with Salivette. In 55% of the samples obtained by expectorating, THC was detected with concentration ranges from 1033 to 6552 ng/mL and in 45% of cases THC was detected at concentrations between 51 and 937 ng/mL. However, using Salivette collection, 26 of the 40 cases had an undetectable THC.  相似文献   

15.
Two hundred and forty-seven serum samples which have been collected by police during roadside testing and have been found positive for amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and/or 3,4-methylenedioxyethamphetamine (MDE) were analyzed for gamma-hydroxybutyrate (GHB). Serum samples were spiked with deuterated GHB as internal standard and acetonitrile was added to achieve dilution and protein precipitation. Samples were analyzed with a LC-MS/MS system operated in the multiple reaction monitoring mode (MRM) using a TurboIonSpray source. Chromatographic separation was achieved using a Synergi Polar RP column applying a gradient elution with a runtime of 15 min. To differentiate between endogenous and exogenously administered GHB a cut-off concentration of 10 microg/mL was applied. Five samples exceeded this concentration and were found positive for GHB. These samples were only found positive for amphetamine but no other amphetamine derivatives were detected, while in three samples THC and in one sample cocaine, benzoylecgonine and ethanol were found.  相似文献   

16.
Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), and ketamine (KT) are widely abused recreational or anorectic drugs in Korea and are regulated under the Controlled Substance Act in Korea. Phenylalkylamines and ketamine analysis is normally performed using both urine and hair samples but there is no established method for the simultaneous analysis of all these phenylalkylamines and ketamine in oral fluids. Oral fluid is easy to collect/handle and can provide an indication of recent drug abuse. In this study, to confirm the presence of phenylalkylamine derivatives and ketamine in oral fluid after screening with an immunoassay, an analytical method using automated solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed and fully validated according to international guidelines. The applicability of the assay was demonstrated by analyzing of authentic oral fluid samples and the results of oral fluid analysis were compared with those in urine and hair to to evaluate the feasibility of oral fluid in forensic cases. The recovery of phenylalkylamines and ketamine from oral fluid collection devices was also assessed. Oral fluid specimens from 23 drug abuse suspects submitted by the police were collected using Salivette (Sarstedt, Nümbrecht, Germany), Quantisal (Immunalysis, Pomona, CA) or direct expectoration. The samples were screened using a biochip array analyzer (Evidence Investigator, Randox, Antrim, UK). For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE (RapidTrace, Zymark, MA, USA) with a mixed-mode cation exchange cartridge (CLEAN SCREEN, 130 mg/3 ml, UCT, PA, USA) and derivatization with trifluoroacetic anhydride (TFA). The results from the immunoassay were consistent with those from GC-MS. Twenty oral fluid samples gave positive results for MA, AM, PT and/or PM among the 23 cases, which gave positive results in urine and/or hair. Although large variations in the MA, AM, PT and PM concentrations were observed in three different specimens, the oral fluid specimen was useful for demonstrating phenylalkylamines and ketamine abuse as an alternative specimen for urine.  相似文献   

17.
In this study we reviewed the post-mortem cases in the years 1999-2004 that were presented at the Netherlands Forensic Institute. The concentrations of amphetamine-based drugs in femoral blood from cases of suspected unnatural death were compared with concentrations in whole blood from non-fatal cases of driving under the influence (DUI cases) and with literature. Furthermore, the combinations with other drugs and/or alcohol were investigated. Amphetamine-based drugs were present in 70 post-mortem cases and 467 DUI cases. The most detected amphetamine-based drug was MDMA, followed by amphetamine. The presence of MDA could usually be explained by metabolism of MDMA. Methamphetamine and MDEA were rarely present. Frequently, the amphetamine-based drugs were taken in combination with alcohol and/or other non-amphetamine-based drugs such as cocaine or cannabinoids. The 70 post-mortem cases were divided into 38 amphetamine-based drug caused (i.e. the amphetamine-based drug directly caused or contributed to the death) and 32 amphetamine-based drug related deaths (i.e. death was not directly caused by the amphetamine-based drug). In the latter category, other (poly)drug intoxications and death by violence or drowning were the most frequent causes of death. In 30 cases, MDMA caused death directly. The range in blood concentrations of MDMA in these cases was substantial, i.e. 0.41-84 mg/L with a median concentration of 3.7 mg/L (n=30). MDMA blood concentrations in the MDMA related deaths (n=20) and in the DUI cases (n=360) varied up to 3.7 and 4.0 mg/L, respectively. Seven victims died from the direct effects of amphetamine; the blood concentration of amphetamine ranged from 0.24 to 11.3 mg/L, with a median concentration of 1.7 mg/L (n=7). The median concentrations of amphetamine in the amphetamine related deaths (n=13) and the DUI cases (n=208) were much lower, i.e. 0.28 and 0.22 mg/L, respectively. Amphetamine blood concentrations up to 6.0 and 2.3 mg/L were seen in the drug related deaths and DUI cases, respectively. The most frequently encountered amphetamine-based drugs in the investigated deaths were MDMA and amphetamine. The majority of MDMA- and amphetamine-caused deaths, i.e. 90% of these deaths, occurred with blood concentrations above 1.5 and 0.80 mg/L, respectively. MDMA and amphetamine blood concentrations in drug related deaths and DUI cases, however, overlap the range of fatal concentrations. Therefore, MDMA or amphetamine concentrations should never be used alone to establish the cause of death.  相似文献   

18.
尿中MDMA及其代谢物的GC和GC/MS分析   总被引:3,自引:0,他引:3  
Shen M  Yan W  Shen B  Xiang P  Huang Z  Liu W  Bo J 《法医学杂志》1998,14(1):10-11,24
考察MDMA在人体内的代谢以及建立尿中MDMA和体内主要代谢物MDA的分析方法。尿样水解后经液-液提取处理,用GC/MS(EI、PCI)和GC/FID法分析。人摄入MDMA后尿中MDA和原体MDMA比约为0.10~0.14。GC/MS/SIM和GC/FID法的最低检出限为2ng/ml和50ng/ml,回收率大于85%,变异系数小于10%。该法简便快速、灵敏度高、结果可靠,可用于MDMA滥用者的尿样鉴定。MDA/MDMA浓度比可作为评判毒分结果的参考指标。  相似文献   

19.
A fast and simple method to detect some commonly abused illicit drugs, amphetamine, methamphetamine, 3,4-methylendioxy-amphetamine (MDA), 3,4-methylendioxy-methamphetamine (MDMA), 3,4-methylendioxy-N-ethylamphetamine (MDEA) and phencyclidine (PCP) in urine using solvent microextraction (SME) combined with gas chromatography (GC) analysis has been developed. The extraction is conducted by suspending a 2 microl drop of chloroform in a 2 ml urine sample. Following 8 min of extraction, the organic solvent is withdrawn into the syringe and injected into a GC with a pulsed discharge helium ionization detector (PDHID). The effects of different extraction solvents and times, pH and sample preparation were studied. The optimized method was capable of detecting drugs in urine at concentrations below Substance Abuse and Mental Health Services Administration (SAMHSA) established cut-off values for preliminary testing. Good linearity and reproducibility of extraction were obtained. The limits of detection were 0.5 microg/ml for amphetamine, 0.1 microg/ml for methamphetamine and MDA, 0.05 microg/ml for MDMA, 0.025 microg/ml for MDEA and 0.015 microg/ml for PCP. Relative standard deviation (R.S.D.) values ranged between 5 and 20% for the studied drugs.  相似文献   

20.
This paper describes the analytical methodology for the determination of MDMA, MDA, MDEA and MBDB in oral fluid. After a liquid–liquid extraction, the analysis was carried out by high performance liquid chromatography (HPLC), with fluorescence detection. The detector wavelength was fixed at 285 nm for excitation and 320 nm for emission. The mobile phase, a mixture of phosphate buffer (pH = 5) and acetonitrile (75:25), and the column, Kromasil 100 C8 5 μm 250 mm × 4.6 mm, allowed good separation of the compounds in an isocratic mode in only 10 min. The method was validated and showed good limits of detection (2 ng/mL) and quantitation (10 ng/mL) for all the amphetamine derivatives. No interfering substances were detected. A stability study of these compounds in oral fluid stored at three different temperatures (−18, 4 and 20 °C) over 10 weeks was conducted, showing a time-dependent degradation of the four compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号