首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到2条相似文献,搜索用时 0 毫秒
1.
Since the beginning of our work in 2003 our laboratory has focused exclusively on STR DNA from bone, a powerful tool in missing person cases. In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, recovered from water, degraded, and/or contain inhibitory substances. To address these challenges, this study has evaluated the performance of relatively new STR kits Investigator® 24plex QS kit (Qiagen) and GlobalFiler™ PCR Amplification kit (Thermo Fisher Scientific) by comparing it with current uses of the AmpFLSTR® Identifiler® Plus kit (Applied Biosystems) to obtain genetic information from skeletal remains. We analyzed 20 bone samples of skeletal remains from routine casework submitted for body identifications by law enforcement corresponding using Investigator® 24plex QS kit and GlobalFiler™ PCR Amplification kit, previously analysed AmpFLSTR® Identifiler® Plus kit (Thermo Fisher Scientific). The data indicates that the STR profiles obtained using the GlobalFiler™ and Investigator® 24plex QS kit for analysis of skeletal remains has shown results in an increased number of reportable genetic loci, and provide greater power of discrimination in comparison to the Identifiler® Plus Kit. Advanced extraction and purification techniques, together with more sensitive and robust new amplification kits allowed us to overcome the challenges associated with processing compromised skeletal remains and ultimately obtain full STR DNA profiles in 99% of the bones.  相似文献   

2.
Abstract: A year after the introduction of Identifiler? into the forensic DNA laboratories of the Institute of Environmental Science and Research Limited (ESR), increasing occurrences of dropout of the three loci, D7S820, D18S51, and FGA, were observed in samples where the DNA was not degraded and sufficient DNA was present that full DNA profiles were to be expected. The dropout was either partial or complete at these loci. Full profiles could sometimes be obtained by reamplification of samples using the same input amount of DNA. After a thorough investigation of the methods and procedures used in the laboratory, the cause of this inhibition was identified as the cleaning agent TriGene? ADVANCE. This was determined after the deliberate addition of varying amounts of different cleaning reagents into the DNA amplification reactions. At concentrations of 0.004% TriGene? ADVANCE caused inhibition resulting in tri‐loci dropout. At concentrations of 0.04% and higher, complete inhibition was observed. An effect was also seen on the amplification of samples using the Y STR profiling system PowerPlex®Y. This work highlights the importance of checking all reagents and chemicals prior to use, even those with no apparent direct influence on the DNA profiling process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号