首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid and sensitive method using LC-MS/MS triple stage quadrupole for the determination of traces of amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA, “ecstasy”), 3,4-methylenedioxyethamphetamine (MDEA), and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in hair, blood and urine has been developed and validated. Chromatography was carried out on an Uptisphere ODB C18 5 μm, 2.1 mm × 150 mm column (Interchim, France) with a gradient of acetonitrile and formate 2 mM pH 3.0 buffer. Urine and blood were extracted with Toxitube A® (Varian, France). Segmented scalp hair was treated by incubation 15 min at 80 °C in NaOH 1 M before liquid–liquid extraction with hexane/ethyl acetate (2/1, v/v). The limits of quantification (LOQ) in blood and urine were at 0.1 ng/mL for all analytes. In hair, LOQ was <5 pg/mg for MA, MDMA, MDEA and MBDB, at 14.7 pg/mg for AP and 15.7 pg/mg for MDA. Calibration curves were linear in the range 0.1–50 ng/mL in blood and urine; in the range 5–500 pg/mg for MA, MDMA, MDEA and MBDB, and 20–500 pg/mg for AP and MDA. Inter-day precisions were <13% for all analytes in all matrices. Accuracy was <20% in blood and urine at 1 and 50 ng/mL and <10% in hair at 20 and 250 pg/mg. This method was applied to the determination of MDMA in a forensic case of single administration of ecstasy to a 16-year-old female without her knowledge during a party. She suffered from hyperactivity, sweating and agitation. A first sample of urine was collected a few hours after (T + 12 h) and tested positive to amphetamines by immunoassay by a clinical laboratory. Blood and urine were sampled for forensic purposes at day 8 (D + 8) and scalp hair at day 60 (D + 60). No MDMA was detected in blood, but urine and hair were tested positive, respectively at 0.42 ng/mL and at 22 pg/mg in hair only in the segment corresponding to the period of the offence, while no MDA was detectable. This method allows the detection of MDMA up to 8 days in urine after single intake.  相似文献   

2.
A fast method was designed for the simultaneous determination of amphetamine (A), methamphetamine (MA), PMA, MDA, MDMA, MDEA and MBDB in urine. The drugs were analysed by LC (ESI)-MS/MS, after a simple liquid-liquid extraction in the presence of the deuterated analogues. Reverse phase separation on an Atlantis dC18 Intelligent Speed column was achieved in less than 4 min under gradient conditions, and the total run time was 8 min. The method was fully validated, including linearity (1-1000 ng/mL for A, MDMA, MDEA and MBDB; 2-1000 ng/mL for MDA and PMA; 1-200 ng/mL for MA; r2>0.99 for all compounds), recovery (>80%), within-day and between-day precision and accuracy (CV and MRE<12.7% for intermediate level and ULOQ, and <17.2% for LLOQ), limit of detection (0.2 ng/mL for MDMA, MDEA and MBDB; 0.5 ng/mL for A, MA and PMA; 1 ng/mL for MDA) and quantitation (1 ng/mL for A, MA, MDMA, MDEA and MBDB; 2 ng/mL for MDA and PMA) and relative ion intensities. No matrix effect was observed. The procedure proved to be sensitive, specific and rapid, and was applied to real forensic cases.  相似文献   

3.
The metabolite-to-parent drug ratios were determined in the hair of 2444 methamphetamine (MA) abusers who had produced MA-positive hair results from 2001 to May 2005 and in the hair of 53 ecstasy abusers who had produced positive methylenedioxymethamphetamine (MDMA) hair results from 2002 to May 2005. For the hair analyses, hair strands were washed, cut into small pieces and extracted for 20 h in 1 mL methanol containing 1% HCl. Drugs in the extract were determined by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring after derivatization with trifluoroacetic anhydride. The six range groups were divided as follows on the basis of MA concentrations in hair (n = 2389): 0.5-5 ng/mg (n = 950), 5-10 ng/mg (n = 582), 10-20 ng/mg (n = 503), 20-30 ng/mg (n = 160), 30-40 ng/mg (n = 80), more than 40 ng/mg (n = 114) to assess the correlations between MA concentrations and metabolite-to-parent drug ratios. In groups of higher MA concentrations, lower ratios of AP/MA were found, and there was a statistically significant difference among six range groups. Comparisons of age groups (tens, twenties, thirties, forties, fifties, and sixties) and male and female subjects for the ratios of AP/MA showed a statistically significant difference. The detection of metabolites and the parent drug with reasonable ratios was found to be a useful indicator for distinguishing internal drug incorporation from external contamination. In our study, MA users can produce 0.4-116% (mean = 9%) of amphetamine (AP) concentrations in hair, and ecstasy users 1-110% (mean = 12%) of methylenedioxyamphetamine (MDA) in appropriately washed hair samples.  相似文献   

4.
The aim of the study was to determine the enantioselective disposition of 3,4-methylenedioxymethamphetamine (MDMA) and other amphetamine-type stimulants (ATS) in segmented hair specimens of self-declared ecstasy abusers, who took part in a double-blind placebo-controlled six-way crossover study during approximately 7 weeks, during which they received a 75 and a 100 mg dose of racemic MDMA twice. Hair specimens were washed and cut into pieces of 2 cm length. After digestion and solid phase extraction, the enantiomers were derivatized with a chiral agent (2S,4R)-N-heptafluorobutyryl-4-heptafluorobutoyloxy-prolyl chloride, developed at the authors laboratory and quantified by gas chromatography coupled to mass spectrometry operating in the negative chemical ionization mode. Most of the hair specimens that were tested positive for MDMA showed a predominance of the (R)-enantiomer. The R/S ratios of MDMA varied between 1.02 and 2.75 and total concentrations ranged from 0.1 to 20.1 ng/mg. The enantiomers of its metabolite 3,4-methylenedioxyamphetamine (MDA) were also quantified in most hair segments. The R/S ratios of MDA varied between 0.60 and 1.60, while the concentrations of the enantiomers ranged from 10 to 160 pg/mg hair. When segmental analysis was performed on single hair specimens, no inversion of the R versus S ratios of MDMA and MDA was observed. The predominance of (R)-MDMA in hair was in accordance with those already published for other matrices. Furthermore, both enantiomers of amphetamine (AM) were also detected in hair segments of four volunteers and the R/S ratios ranged from 1.00 to 1.47.  相似文献   

5.
Drug use histories were collected from 100 subjects recruited from the "dance scene" in and around Glasgow, Scotland. In addition, each subject donated a hair sample which was analyzed by gas chromatography/mass spectrometry (GC/MS) for amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MD MA) and 3,4-methylenedioxyethylamphetamine (MDEA). The hair samples were analyzed in two 6 cm segments or in full, ranging from 1.5 to 12 cm depending on the length of the hair. Approximately 10 mg of hair was ground to a fine powder before treatment with beta-glucuronidase/aryl sulfatase. A solid-phase extraction procedure was carried out followed by derivatization with pentafluoropropionic anhydride (PFPA). All extracts were analyzed by gas chromatography/mass spectrometry (GC/MS). Of the 139 segments analyzed, 77 (52.5%) were positive for at least one of the five amphetamines. The drug concentrations found in the hair were compared with the self-reported drug histories. A concordance of greater than 50% was found between the self-report data and levels detected in hair. However, no correlation was found between the reported number of "ecstasy" tablets consumed and the drug levels detected in hair. An increase in the average drug levels measured was observed from low to high use (number of "ecstasy" tablets/month). A large number of false negatives and a low number of false positives were observed.  相似文献   

6.
In a double-blind placebo controlled study on psychomotor skills important for car driving (Study 1), a 75 mg dose of +/- 3,4-methylenedioxymethamphetamine (MDMA) was administered orally to 12 healthy volunteers who were known to be recreational MDMA-users. Toxicokinetic data were gathered by analysis of blood, urine, oral fluid and sweat wipes collected during the first 5h after administration. Resultant plasma concentrations varied from 21 to 295 ng/ml, with an average peak concentration of 178 ng/ml observed between 2 and 4h after administration. MDA concentrations never exceeded 20 ng/ml. Corresponding MDMA concentrations in oral fluid, as measured with a specific LC-MS/MS method (which required only 50 microl of oral fluid), generally exceeded those in plasma and peaked at an average concentration of 1215 ng/ml. A substantial intra- and inter-subject variability was observed with this matrix, and values ranged from 50 to 6982 ng/ml MDMA. Somewhat surprisingly, even 4-5h after ingestion, the MDMA levels in sweat only averaged 25 ng/wipe. In addition to this controlled study, data were collected from 19 MDMA-users who participated in a driving simulator study (Study 2), comparing sober non-drug conditions with MDMA-only and multiple drug use conditions. In this particular study, urine samples were used for general drug screening and oral fluid was collected as an alternative to blood sampling. Analysis of oral fluid samples by LC-MS/MS revealed an average MDMA/MDEA concentration of 1121 ng/ml in the MDMA-only condition, with large inter-subject variability. This was also the case in the multiple drug condition, where generally, significantly higher concentrations of MDMA, MDEA and/or amphetamine were detected in the oral fluid samples. Urine screening revealed the presence of combinations such as MDMA, MDEA, amph, cannabis, cocaine, LSD and psilocine in the multiple-drug condition.  相似文献   

7.
The Bavarian State Bureau of Investigation in Munich has the exclusive responsibility for investigation of criminal acts. One considerable expertise is that of hair analysis. According to the legal system in Germany, there is a special interest when some clients' hair tested positive for illicit drugs. An accused with a lot of drugs in his hair will be treated as a supposed addict and will be guaranteed extenuating circumstances. The instrumentation used for hair analysis is a powerful analytical tool: a Varian 3400 gas chromatograph linked to a Finnigan Tandem-MS (TSQ 700). The methanol extraction method is used for the detection of illegal drugs and metabolites: amphetamine, methamphetamine, MDA, MDMA (ecstasy), MDE, MBDB, methadone, THC, EDDP (metabolite of methadone), cocaine, benzoylecgonine, cocaethylene, opiates (dihydrocodeine, codeine, heroin, 6-monoacetylmorphine, morphine, acetylcodeine). For the detection of 9-carboxy-THC by negative chemical ionization the hair sample is hydrolyzed under alkaline conditions. Solid-phase extraction is used for clean-up. The LOQ for the determination of 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic-acid is 0.16 pg/mg hair. An unsurpassed combination for rendering an expert opinion based on hair analysis may be: a forensic expert using diligence and experience, coupled with the performance of a sophisticated analytical instrument.  相似文献   

8.
Hair of young subjects (N = 36) suspected for drug abuse was analysed for morphine, codeine, heroin, 6-acetylmorphine, cocaine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyethylamphetamine (MDEA). The analysis of morphine, codeine, heroin, 6-acetylmorphine, cocaine, and methadone in hair included incubation in methanol, solid-phase extraction, derivatisation by the mixture of propionic acid anhydride and pyridine, and gas chromatography/mass spectrometry (GC/MS). For amphetamine, methamphetamine, MDA, MDMA, and MDEA analysis, hair samples were incubated in 1M sodium hydroxide, extracted with ethyl acetate, derivatised with heptafluorobutyric acid anhydride (HFBA), and assayed by GC/MS. The methods were reproducible (R.S.D. = 5.0-16.1%), accurate (85.1-100.6%), and sensitive (LoD = 0.05-0.30ng/mg). The applied methods confirmed consumption of heroin in 18 subjects based on positive 6-acetylmorphine. Among these 18 heroin consumers, methadone was found in four, MDMA in two, and cocaine in two subjects. Cocaine only was present in two, methadone only in two, methamphetamine only in two, and MDMA only in seven of the 36 subjects. In two out of nine coloured and bleached hair samples, no drug was found. Despite the small number of subjects, this study has been able to indicate the trend in drug abuse among young people in Croatia.  相似文献   

9.
The prevalence and age distribution of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in hair samples by gas chromatography/mass spectrometry (GC/MS) were studied. The recoveries obtained from hair were 97% and 99% for MDMA and MDA, respectively. The inter- and intra-assay precision and accuracy were determined. Out of 791 hair samples, 44 (5.6 %) contained MDMA and/or MDA. Out of these 44 subjects, urinalyses from 35 were negative for both MDMA and MDA, while only 9 were positive. We also evaluated concentrations of MDMA and MDA, and the metabolite-to-parent drug ratios. This study showed that the abuse of MDMA or MDA was found principally among young adults and male abusers. We found the epidemiology of ecstasy users in Korea between March 2002 and April 2003.  相似文献   

10.
SPE/UPLC法检测血中吗啡、苯丙胺类及氯胺酮   总被引:1,自引:0,他引:1  
目的建立SPE/UPLC方法在同一条件下同时检测血中吗啡、苯丙胺类及氯胺酮。方法采用SCX 3cc(60mg)固相萃取柱萃取血中吗啡、MA、MDMA、MDA及氯胺酮,用超高效液相色谱(UPLC)-二极管阵列检测器(PDA)检测,结合保留时间和紫外光谱进行定性、定量分析,对实验各环节进行优化,并进行实际案例检测。结果吗啡、MA、MDMA、MDA、氯胺酮的固相萃取提取回收率分别为81.4%±2.51%、88.2%±2.48%、91.8%±2.03%、93.8%±1.46%、74.8%±2.27%,峰面积和质量浓度的线性关系良好(r〉0.999),线性范围分别为0.08~100μg/mL、0.4~100μg/mL、0.2~75μg/mL、0.3~75μg/mL、0.4~100μg/mL,检出限分别为30pg、200pg、80pg、100pg、200pg。结论本文所建方法适用于血中吗啡、苯丙胺类、氯胺酮常见毒品的筛选及定量分析。  相似文献   

11.
A controlled study was undertaken to determine the stability of the designer drugs MDA, MDMA and MDEA in pooled serum, whole blood, water and urine samples over a period of 21 weeks. The concentrations of the individual designer drugs in the various matrices were monitored over time, in the dark at various temperatures (-20, 4 or 20 degrees C), for a low (+/- 6 ng/ml for water, serum and whole blood and +/- 150 ng/ml for urine) and a high concentration level (+/- 550 ng/ml for water, serum and whole blood and +/- 2500 ng/ml for urine). Compound concentrations were measured using a validated HPLC assay with fluorescence detection. Our study demonstrated no significant loss of the designer drugs in water and urine at any of the investigated temperatures for 21 weeks. The same results were observed in serum for up to 17 weeks, and up to 5 weeks in whole blood. After that time, the compounds could no longer be analyzed due to matrix degradation, especially in the low concentration samples that were stored at room temperature. This study demonstrates that the designer drugs, MDA, MDMA and MDEA are stable when stored at -20 degrees C for 21 weeks, even in haemolysed whole blood.  相似文献   

12.
A simple and rapid method for direct simultaneous determination of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA) and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in seized tablets was developed using gas chromatography with flame ionization detection. Separation of all six underivatized amphetamines, including diphenylamine as internal standard, was performed in about 6 min, using SPB-50 capillary column. Amphetamine and methamphetamine eluted with negligible tailing while the other amphetamines had highly symmetrical peaks. Sensitivity per component on-column was in the nanogram range, and reproducibility from 2.6 to 6.6% at low concentration (2.4 microg/mL) and from 1.2 to 2.6% at high (70 microg/mL) concentration. The method has a wide linear range, from Limit of detection (LOD) to almost 200 microg/mL, thus allowing analysis of different samples across a wide range of possible concentrations of amphetamines. This simple, fast and precise method using gas chromatography--flame ionization detector (GC--FID), in conjunction with other methods (TLC, IR, HPLC), can be used for identification of amphetamines and direct determination in seized tablets, especially in laboratories with heavy workload.  相似文献   

13.
Phentermine (PT) has been widely used as an anti-obesity drug. This drug has to be used with caution due to its close resemblance with amphetamines in its structure and toxicity profile. Recently, PT is in distribution by illegal modes and is found to be available through sources such as the internet, thus their misuse and/or abuse is threatening to be a serious social issue. In the present study, 32 cases of drug suspects were observed for PT abuse, detected using hair samples for drug analysis. PT and other amphetamines, such as methamphetamine (MA), amphetamine (AP), 3,4-methylenedioxyamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA), were extracted using 1% HCl in methanol for 20 h at 38°C. The extracts were derivatized with trifluoroacetic anhydride (TFAA) and analyzed using gas chromatography/mass spectrometry (GC/MS). Among the 32 cases of PT abuse, MA and its main metabolite, AP were identified in seven cases and MDMA and its main metabolite, MDA were detected in two other cases.  相似文献   

14.
A fast and simple method to detect some commonly abused illicit drugs, amphetamine, methamphetamine, 3,4-methylendioxy-amphetamine (MDA), 3,4-methylendioxy-methamphetamine (MDMA), 3,4-methylendioxy-N-ethylamphetamine (MDEA) and phencyclidine (PCP) in urine using solvent microextraction (SME) combined with gas chromatography (GC) analysis has been developed. The extraction is conducted by suspending a 2 microl drop of chloroform in a 2 ml urine sample. Following 8 min of extraction, the organic solvent is withdrawn into the syringe and injected into a GC with a pulsed discharge helium ionization detector (PDHID). The effects of different extraction solvents and times, pH and sample preparation were studied. The optimized method was capable of detecting drugs in urine at concentrations below Substance Abuse and Mental Health Services Administration (SAMHSA) established cut-off values for preliminary testing. Good linearity and reproducibility of extraction were obtained. The limits of detection were 0.5 microg/ml for amphetamine, 0.1 microg/ml for methamphetamine and MDA, 0.05 microg/ml for MDMA, 0.025 microg/ml for MDEA and 0.015 microg/ml for PCP. Relative standard deviation (R.S.D.) values ranged between 5 and 20% for the studied drugs.  相似文献   

15.
A solid-phase enzyme immunoassay involving microtiter plates was recently proposed by International Diagnostic Systems corporation (IDS) to screen for buprenorphine in human serum. The performance of the kit led us to investigate its applicability in other biological matrices such as urine or blood, and also hair specimens. Low concentrations of buprenorphine were detected with the ELISA test and confirmed by HPLC/MS (buprenorphine concentrations measured by HPLC/MS: 0.3 ng/mL in urine, 0.2 ng/mL in blood, and 40 pg/mg in hair). The intra-assay precision values were 8.7% at 1 ng/mL of urine (n = 8), 11.5% at 2 ng/mL in serum (n = 8), and 11.5% at 250 pg/mg of hair (n = 8), respectively. The immunoassay had no cross-reactivity with dihydrocodeine, ethylmorphine, 6-monoacetylmorphine, pholcodine, propoxyphene, dextromoramide, dextrometorphan at 1 and 10 mg/L, or codeine, morphine, methadone, and its metabolite EDDP. A 1% cross-reactivity was measured for a norbuprenorphine concentration of 50 ng/mL. Finally, the immunoassay was validated by comparing authentic specimens results with those of a validated HPLC/MS method. From the 136 urine samples tested, 93 were positive (68.4%) after the ELISA screening test (cutoff: 0.5 ng/mL) and confirmed by HPLC/MS (buprenorphine concentrations: 0.3-2036 ng/mL). From the 108 blood or serum samples screened, 27 were positive (25%) after the ELISA test with a cutoff value of 0.5 ng/mL (buprenorphine concentrations: 0.2-13.3 ng/mL). Eighteen hair specimens were positive (72%) after the screening (cutoff: 10 pg/mg) and confirmed by LC/MS (buprenorphine concentrations: 40-360 pg/mg). The ELISA method produced false positive results in less than 21% of the cases, but no false negative results were observed with the immunological test. Four potential adulterants (hypochloride 50 mL/L, sodium nitrite 50 g/L, liquid soap 50 mL/L, and sodium chloride 50 g/L) that were added to 10 positive urine specimens (buprenorphine concentrations in the range 5.3-15.6 ng/mL), did not cause a false negative response by the immunoassay.  相似文献   

16.
It has recently been reported that purity of illicit tablets of ecstasy (MDMA) is now high. Our objective was to confirm whether hair of drug users, who request only ecstasy from their supplier, contains MDMA in the absence of other drugs. GC-MS analysis of scalp hair segments disclosed the presence of MDMA in 19 of 21 subjects and amphetamine/methamphetamine in eight subjects. Surprisingly, seven subjects had hair levels of the MDMA metabolite, MDA, equal to or greater than those of MDMA, suggesting use of MDA in addition to that of MDMA. These amphetamine derivatives might be included by clandestine laboratories to enhance effects of the drug cocktail or because of a perception that MDA synthesis might be simpler than that of MDMA. Drug users and investigators examining possible brain neurotoxic effects of MDMA need to consider that "ecstasy" tablets can contain MDA and methamphetamine despite no demand for the drugs.  相似文献   

17.
This paper describes the analytical methodology for the determination of MDMA, MDA, MDEA and MBDB in oral fluid. After a liquid–liquid extraction, the analysis was carried out by high performance liquid chromatography (HPLC), with fluorescence detection. The detector wavelength was fixed at 285 nm for excitation and 320 nm for emission. The mobile phase, a mixture of phosphate buffer (pH = 5) and acetonitrile (75:25), and the column, Kromasil 100 C8 5 μm 250 mm × 4.6 mm, allowed good separation of the compounds in an isocratic mode in only 10 min. The method was validated and showed good limits of detection (2 ng/mL) and quantitation (10 ng/mL) for all the amphetamine derivatives. No interfering substances were detected. A stability study of these compounds in oral fluid stored at three different temperatures (−18, 4 and 20 °C) over 10 weeks was conducted, showing a time-dependent degradation of the four compounds.  相似文献   

18.
Identification of 3,4-methylenedioxy-N-methylamphetamine (MDMA, ecstasy) in five cases of intoxication using nuclear magnetic resonance (NMR) spectroscopy of human urine is reported. A new water suppression technique PURGE (Presaturation Utilizing Relaxation Gradients and Echoes) was used. A calibration curve was obtained using spiked samples. The method gave a linear response (correlation coefficient of 0.992) over the range 0.01–1 mg/mL. Subsequently, quantitation of the amount of MDMA present in the samples was performed. The benefit and reliability of NMR investigations of human urine for cases of intoxication with MDMA are discussed.  相似文献   

19.
A gas chromatography-mass spectrometry (GC-MS) method is described for the screening and detection of morphine, codeine, cocaine, benzoylecgonine, methylecgonine, cocaethylene, delta-9-tetrahydrocannabinol (THC), 11-nor-9-carboxy-THC (THC-COOH), 11-hydroxy-THC (11-OH-THC), amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymetamphetamine (MDMA) and N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB) in small blood samples and bloodstains using solid phase SPE columns and a pipetting robot (Gilson Aspec XL). The detection limits are in the order of 1.62-4.10 ng/50 microl spot (amphetamines), 0.15-0.82 ng/50 microl spot (cannabinoids), 1.67-4.70 ng/50 microl spot (cocaine and derivatives) and 4.53-4.91 ng/50 microl spot (opiates) and the correlation factors are between 0.9957 and 0.9999. The method has proven useful in forensic cases with only small sample volumes or bloodstains.  相似文献   

20.
In mid 2009 Victoria introduced compulsory drug testing of blood taken from all injured drivers taken to hospital. Δ(9)-Tetrahydrocannabinol (THC), methylamphetamine (MA) and 3,4-methylenedioxy-methylamphetamine (MDMA) are prohibited and if drivers are positive to any amount an automatic penalty is enforced. Laboratory screens were conducted on preserved blood using ELISA testing for cannabis metabolite and methylamphetamines and a fully validated LC-MS/MS method for 105 drugs including THC, amphetamines, opioids, benzodiazepines, antidepressants and antipsychotics and a number of other psychoactive substances using a minimum of two transitions per drug. Conventional GC-testing for ethanol was used to screen and quantify the presence of alcohol. 1714 drivers were tested and showed alcohol in 29% (≥ 0.01 g/100mL) and drugs in 35%. The positive rate for the three drugs prohibited by legislation was 12.5%. The prevalence of THC, MA and MDMA was 9.8%, 3.1%, and 0.8%, respectively. The range of THC concentrations in blood was 2-42 ng/mL (median 7) of which 70% had a concentration of 10 ng/mL or higher. The range of concentrations for MA and MDMA was 0.02-0.4 and 0.03-0.3mg/L (median for both drugs was 0.05 mg/L). Drugs of any type were detected in 35% of cases. The other drugs were largely prescribed drugs such as the antidepressants (9.3%) and benzodiazepines (8.9%). Neither 6-acetylmorphine nor cocaine (or benzoylecgonine) was detected in these cases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号