首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Technical characteristics of the used fire-arm and ammunition, the firing range and the shot through garments of the victim are essential factors, that exercise an influence on the appearance of gunshot injuries. An exemplary case-report shall emphasize the importance of these factors. It deals with a suicidal double-shot fired from an automatic rifle by a young soldier. The wounds were localized in the left chest region and the adjacent skin was blackened by soot in a remarkable geometrical pattern, although an ammunition with a smokeless charge has been used. By means of comparative shots we have good reasons to suppose this phenomenon to be caused by rests of gun powder and pressure of the explosion gas leaved in the barrel after the first shot. The second projectile pushed out this explosion gas to the skin that had been uncovered in a star-shaped way by the first shot.  相似文献   

2.
Pumpguns are shotguns with pump action whose injuries and wound mechanisms have several special features: extremely high kinetic energy of the shot (2500 to 3500 J) frequent cases of "Kr?nlein shots" (exenteration of the brain) punchmark/imprint immediately adjacent to the entrance wound from the front of the pipe magazine exit wounds from buckshot may be similar to pellet entrance injuries from a distant shotgun discharge the use of various shotgun cartridges (plastic ammunition, slug bullet, various lead pellets) within the same weapon. The change in the Austrian gun law and the banning of the pumpgun in 1995 is also discussed in the article.  相似文献   

3.
A total of 103 suicidal and 29 homicidal gunshot fatalities were evaluated. In 42% of the suicides, characteristic findings like blood spatters and/or powder soilings, could be found on the shooting hand by naked-eye inspection indicating the importance of an accurate examination of the deceased's hands at autopsy for a preliminary diagnosis. Petechial hemorrhages of the conjunctivae due to the gas pressure after discharge of the weapon were observed in 22% of those cases with contact shot wounds to the head/neck, but not in cases of distant shot injuries following the use of non-high velocity ammunition. Therefore, conjunctival petechiae can be regarded as an additional but optional sign of contact head shots in cases without alterations possibly influencing the development of conjunctival pin-point bleedings. The evidence of such findings can be of practical importance if the entrance shot wound cannot be examined for whatever reason.  相似文献   

4.
We report three cases where fatal neck injuries were caused by blanks from starting pistols. The weapons were loaded with blank cartridges or tear gas cartridges. Neither live ammunition nor any form of projectile was used. All three cases involved a contact discharge. The gas pressure caused by firing the weapons created extensive wound cavities in all three cases. Each victim died from blood loss as a result of ruptured cervical vessels; there were no air embolisms. In one case, a man shot himself eight times with two different starting pistols, and the wounds could be matched to each gun by the muzzle imprint marks on the neck.  相似文献   

5.
Now and again ammunition is offered emphasizing its "less deadly" or "not at all deadly" effects. On application, however, these types of ammunition contrary to the manufacturer's allegations turn out to be a real threat. On the one hand results can be rather harmful while on the other side at court a remonstration on the grounds of not knowing such outcome beforehand may be successful. Under these aspects construction and effects of a special small shot ammunition for revolvers (Speer 38/357 Shot Shells, manufactured by CCI), of the cartridge "Short-Stop", manufactured by MB Associates in San Ramon (California) and, in connexion with own casework, a "shock-defense" sort of ammunition, manufactured by Rauchalles (Offenburg, West Germany) are compared and discussed with respect to their construction and effects.  相似文献   

6.
The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region, and thereafter penetrated the left side of the neck, causing tearing of the left common carotid artery and the right internal carotid artery. The entrance wound in the axilla was larger than the other wounds, and before autopsy it was believed that the shotgun had been fired twice, causing one wound in the neck and one wound perforating the infraclavicular region and exiting through the left axillary region. Thus, this case shows that unusual wound patterns in shotgun fatalities can easily lead to incorrect assumptions with regard to number and direction of shots fired unless thorough investigation is carried out postmortem.  相似文献   

7.
The Tucson Police Department, Tucson, AZ, has begun using the Polyshok Impact Reactive Projectile (IRP), a new type of shotgun ammunition that includes a lead bead core that travels within single, plastic-encased projectile. On impact, the core is released to distribute over a small area, thereby disintegrating on impact to reduce the likelihood of exit or collateral damage on missed shots. After a brief review of shotgun slug ballistics and wound characteristics and a discussion of the mechanism of the Polyshok IRP, we report the first death in the United States from this ammunition. Findings included a single entrance wound with plastic ammunition components and small lead particles recovered from the body, the combination of which normally would suggest a close-range shooting with birdshot. However, the characteristics of this ammunition create different patterns than are found with slugs or shot, so that a medical examiner unfamiliar with the Polyshok IRP could draw inaccurate conclusions about ammunition and range of fire. Because the single projectile fired from this ammunition is composed of both plastic and lead, plastic components are likely to be found within the wound at any range of fire, unlike traditional shot or slug ammunition. Also, the small size of lead particles found spread through the wound cavity would ordinarily suggest a small-size shot, whereas the external appearance of the wound (a single entrance with no dispersion of shot) and the pattern of tissue destruction are more consistent with the patterns of injury associated with shotgun slugs.  相似文献   

8.
Handgun ammunition that contains multiple pellets (birdshot) comes in two forms. We describe here the autopsy and radiographic findings in three individuals who were fatally wounded with Glaser safety ammunition and contrast the findings to those reported in shot shell injuries.  相似文献   

9.
Stellate wounds are to be expected in gunshot injuries to the liver and spleen. As to their configuration, they resemble the skin breaks in an absolute close-range shot. The exit wound is larger than the entry wound. The genesis and utility of such injuries for reconstruction of the shot direction are discussed with reference to seven gunshot mortalities. Stellate wounds could also be achieved by shooting at isolated cadaver organs. The experimentally produced gunshot wounds differed from those produced in vivo in that the entry and exit wounds were equally large.  相似文献   

10.
The suicidal infliction of two gunshot wounds to the head represents a critical issue for medicolegal investigation. In principle, simultaneous infliction with two firearms or third parties' involvement, i.e. two consecutive gunshots, have to be considered. We report for the first time on a case of suicidal infliction of two simultaneous gunshots to the head (oral, temporal) with Action 4 expanding ammunition. A male had robbed two service guns and committed suicide thereafter under the influence of high-dose alcohol and cocaine. Interestingly, Action 4 ammunition had been used, leading to an uncommon gunshot wound morphology and extensive backspatter. At the scene, these findings caused confusion; moreover, the number of gunshot wounds was unclear, until autopsy revealed two gunshot wounds to the head, which had obviously been inflicted simultaneously. Expanding ammunition like QD-PEP and Action 4, used by several German federal state police forces, can cause an atypical gunshot wound morphology, most probably due to its peculiar deformation behaviour. Investigators should be careful when interpreting gunshot wound morphology at the scene after usage of such expanding ammunition. With regard to reconstruction in cases of two gunshot wounds to the head and two guns at the scene, two simultaneous gunshots should be taken into consideration.  相似文献   

11.
We report two cases of suicide by multiple gunshots to the head. The first victim (of two shots) fired the first shot, which was observed, into his mouth, leading to damage to the left optic nerve and frontal lobe. The man still was able to drive his car home, where he shot himself in his right temple. He died 2 days later. The second victim (of three shots) was a 58-year-old man who was found dead on his bed. Reconstruction of the case disclosed that the first shot had passed through his tongue and slightly damaged the second cervical vertebral body. He then shot himself in his right temple, leading to damage of the temporal lobe. Finally, he shot himself in his left temple, resulting in destruction of the pons. In the first case, an amateurishly modified 8-mm blank revolver firing 6.35-mm- (.25)-caliber ammunition was used; in the second case, a rifle firing 5.6-mm (.22)-caliber ammunition with a reduced charge was used. In both cases, low-energy transfer to brain tissue by the initial bullets was due to low bullet energy or due to the bullets' missing the brain or vital centers.  相似文献   

12.
Distribution of irritant on the target after a shot from a 99 mm gas gun ME-38 COMPACT from different distances and gas gun MAUZER (a 9 mm HSc model) in use of different ammunition was studied. There is a correlation between irritant distribution characteristics, distance of shot and cartridge brand.  相似文献   

13.
The elemental objects of the research study are: determination of time periods corresponding to gunshot residue particles (GSR) deposition after the shot from selected pistols and a revolver, and evaluation of the deposited particles number. For several shooting experiments were used a pistol CZ model 85, caliber 9 mm Luger with common ammunition 9 mm Luger FMJ Sellier & Bellot, a pistol CZ model 70, caliber 7.65 mm Browning (32 ACP) with common 7.65 mm Browning FMJ Sellier & Bellot ammunition and a revolver S&W Modell 60, barell length 2-1/8', cal. .38 Special with common Sellier&Bellot (FMJ) ammunition. The results of the study have indicated the behavior of GSR particles deposited after a single discharge. The overall time interval of GSR particles deposition and the number of deposited particles with the above mentioned arms and ammunition were established. The results can potentially be used for clarifying the situation at crime scenes and for subsequent interpretation of GSR evidential value in caseworks.  相似文献   

14.
When interpreting firearm injuries, the distinction between gunshot wounds and shotgun wounds is important, and separation of these categories is typically straightforward. However, .410 bore firearms can make the classification difficult. Shotguns and revolvers that can fire the same .410 bore ammunition are readily available. This study investigates the soot and gunpowder deposits and pellet patterning of these two types of weapons using cartridges specially designed for .410 bore revolvers and standard birdshot pellet ammunition. For both ammunition types, the revolver had more prompt pellet dispersion and positive detection of gunpowder at greater distances compared to the shotgun. Additionally, .410 bore slugs are of similar caliber to many common bullets. In comparing the .410 bore slugs to equivalent bullets, some morphologic differences may be imparted on the skin by the slugs, but the greatest insight into the weapon remained with the retained projectiles.  相似文献   

15.
Reported is the case of a man killed by a neighbor with a shotgun loaded with a unusual ammunition. The cartridge contained several shots chained together by metallic wires. Such ammunition has been used for hunting purposes but is now banned, so it can be handmade only. The joined pellets produce a wound with features that are different from those of a wound made by a regular load of pellets. Several interpretive problems are caused by the unknown number of pellets contained in the shell and the effects of the wire holding the shot together.  相似文献   

16.
We examined six cases (four homicides, two suicides) involving gunshot wounds with .25 ACP ammunition. The nature of these cases is described in this article.  相似文献   

17.
Wounds of high‐energy centerfire rifles and shotguns represent distinctive injuries of forensic importance. Previous studies of contact wounds have shown variability in the potential of these weapons to produce bursting wounds of the head. The present study analyzed contact head wounds owing to 26 centerfire rifles and nine shotgun slugs and compared them with respect to weapon, ammunition, entry wound site, and projectile kinetic energy. The bursting effect, defined for this study as disruption of at least 50% of the head, occurred in 25/35 of cases and was related to kinetic energy. Bursting was associated with energies <2700 ft‐lbs in 12/22 cases and energies >2700 ft‐lbs in 13/13 cases. The volume of gunpowder gas injected into the wound was considered as contributing to the bursting phenomenon. There was no relation of bursting to the specific entrance wound site, type of ammunition, or projectile fragmentation.  相似文献   

18.
使用国产7.62mm口径微声轻型冲锋枪,以不同距离射击实验动物,制成带消音器枪弹创,并使用国产7.62mm口径轻型冲锋枪作对照进行对比观察。结果表明:在接触和近距离射击时,带消音器枪弹刻与典型枪弹剑比较有明显不同;根据消音器的结构和原理,结合实验结果,建立了带消音器枪弹创的形态学特征及其诊断依据。为法医学检验鉴定提供了实验性资料。  相似文献   

19.
The goal of this study was the reproduction of shape and pattern of gunshot residues in near contact and contact gunshot wounds by a series of experimental gunshots on a skin and soft tissue model. The aim was to investigate the shape and direction of soot deposits with regard to the muzzle according to different muzzle-target angles, firing distances, type of ammunition and weapon and barrel length. Based on a review of the literature and on the results of the experiments the authors could make the following statements of gunshot residues in angled contact and close contact gunshot: (1) gunshot residues on the target surface can be differentiated in a "inner" and "outer powder soot zone"; (2) the outer powder soot zone is much less visible than the inner powder soot zone and may lack on human skin; (3) with increasing muzzle target distance both inner and outer powder soot halo increase in size and decrease in density; (4) in angled shots the inner powder soot halo shows an eccentric, elliptic shape which points towards the muzzle, regardless of ammunition, calibre and barrel length; (5) the outer powder soot points away from the muzzle in angled contact and close contact shots.  相似文献   

20.
The purpose of weapons designed for self-defence and their ammunition is to allow effective defence without causing serious injury provided that the recommended minimum firing distance is observed. However, close-range and contact shots to vulnerable body regions may cause severe or even fatal injuries. The authors report on a suicide who fired a fatal shot in his mouth with a weapon for self-defence. The weapon used was a double-barrelled SAPL break-action gun, mod. GC 54, from which a Mini Gomm-Cogne, cal. 12/50 rubber shot shell was fired. The wound findings and ballistic characteristics of the weapon are presented and discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号