首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In post-mortem work, blood is a potential source of external contamination of hair. The present study was carried out to investigate the amount of drug absorbed into hair which has been contaminated with blood containing either cocaine or BE. Solutions were prepared containing 0.05, 0.1, 0.2, 0.5 and 3.0 μg/mL of either cocaine or BE in human blood. Samples of approximately 3.2 g of drug-free hair were contaminated by soaking in the blood solutions for 5 min. They were then removed and left at room temperature. Approximately 0.5 g of hair was collected from each of the blood soaked hair samples at 6 h, 1, 2, 4 and 7 days after contamination. As each hair sample was collected it was shampoo-washed to prevent further drug absorption. Hair samples were analysed in triplicate using a fully validated method described previously. EME and cocaethylene were also measured in order to find out if cocaine or BE was breaking down to these compounds. Both cocaine and BE were absorbed into hair in significant concentrations when the concentration in the blood was 0.5 μg/mL or greater; cocaine was more readily absorbed than BE. Cocaine broke down to EME (<LOQ) at 0.5 μg/mL and to EME (>LOQ) and BE (<LOQ) at 3.0 μg/mL. When the blood concentration of cocaine was 0.5 μg/mL or less, there was no evidence of it breaking down to form BE. From the samples soaked in blood containing BE, there was no evidence of the BE breaking down. The absorption of drug into hair did not increase as the contamination period increased from 6 h to 7 days.  相似文献   

2.
Identification of cocaine and subsequent quantification immediately after seizure are problems for the police in developing countries such as Brazil. This work proposes a comparison between the Raman and FT‐IR techniques as methods to identify cocaine, the adulterants used to increase volume, and possible degradation products in samples seized by the police. Near‐infrared Raman spectra (785 nm excitation, 10 sec exposure time) and FT‐IR‐ATR spectra were obtained from different samples of street cocaine and some substances commonly used as adulterants. Freebase powder, hydrochloride powder, and crack rock can be distinguished by both Raman and FT‐IR spectroscopies, revealing differences in their chemical structure. Most of the samples showed characteristic peaks of degradation products such as benzoylecgonine and benzoic acid, and some presented evidence of adulteration with aluminum sulfate and sodium carbonate. Raman spectroscopy is better than FT‐IR for identifying benzoic acid and inorganic adulterants in cocaine.  相似文献   

3.
Although poaching is a common wildlife crime, the high and prohibitive cost of specialised animal testing means that many cases are left un-investigated. We previously described a novel approach to wildlife crime investigation that looked at the identification of human DNA on poached animal remains (Tobe, Govan and Welch, 2011). Human DNA was successfully isolated and amplified from simulated poaching incidents, however a low template protocol was required which made this method unsuitable for use in many laboratories. We now report on an optimised recovery and amplification protocol which removes the need for low template analysis.Samples from 10 deer (40 samples total — one from each leg) analysed in the original study were re-analysed in the current study with an additional 11 deer samples. Four samples analysed using Chelex did not show any results and a new method was devised whereby the available DNA was concentrated. By combining the DNA extracts from all tapings of the same deer remains followed by concentration, the recovered quantity of human DNA was found to be 29.5 pg ± 43.2 pg, 31 × greater than the previous study. The use of the Investigator Decaplex SE (QIAGEN) STR kit provided better results in the form of more complete profiles than did the AmpF?STR® SGM Plus® kit at 30 cycles (Applied Biosystems). Re-analysis of the samples from the initial study using the new, optimised protocol resulted in an average increase of 18% of recovered alleles. Over 17 samples, 71% of the samples analysed using the optimised protocol showed sufficient amplification for comparison to a reference profile and gave match probabilities ranging from 7.7690 × 10? 05 to 2.2706 × 10? 14.The removal of low template analysis means this optimised method provides evidence of high probative value and is suitable for immediate use in forensic laboratories. All methods and techniques used are standard and are compatible with current SOPs. As no high cost non-human DNA analysis is required the overall process is no more expensive than the investigation of other volume crime samples. The technique is suitable for immediate use in poaching incidents.  相似文献   

4.
Allele frequency distributions for 24 short tandem repeat (STR) loci were determined using the PowerPlexR Fusion System (Promega) in 407 Japanese samples. The most informative locus among the 22 STR loci, excluding Amelogenin and DYS391, was Penta E (power of discrimination (PD) = 0.98), while the least informative was TPOX(PD = 0.831). The 22 loci combined matching probability (MP) was calculated to be 4.13 × 10−26. These parameters indicated the usefulness of this 24 STR analysis in forensic personal identification and parentage testing among Japanese population.  相似文献   

5.
PurposeTo construct an empirically rigorous typology of multiple homicide offenders (MHOs).MethodThe current study conducted latent class analysis of the official records of 160 MHOs sampled from eight states to evaluate their criminal careers.ResultsA 3-class solution best fit the data (?2LL = ?1123.61, Bayesian Information Criterion (BIC) = 2648.15, df = 81, L2 = 1179.77). Class 1 (n = 64, class assignment probability = .999) was the low-offending group marked by little criminal record and delayed arrest onset. Class 2 (n = 51, class assignment probability = .957) was the severe group that represents the most violent and habitual criminals. Class 3 (n = 45, class assignment probability = .959) was the moderate group whose offending careers were similar to Class 2.ConclusionA sustained criminal career with involvement in versatile forms of crime was observed for two of three classes of MHOs. Linkages to extant typologies and recommendations for additional research that incorporates clinical constructs are proffered.  相似文献   

6.
IntroductionIn this paper, the authors presented a case of acrylamide poisoning in a middle-aged woman who had underwent unsuccessful cosmetic surgery six years earlier. The victim was told that the product that had been injected into her face was Restylane®, which mainly contained sodium hyaluronate and was the first and only Food and Drug Administration (FDA)-approved dermal filler for lip enhancement in the USA for more than 20 years. Widespread facial infections occurred several years post-injection; finally, the victim had to undergo removal surgery. Acrylamide poisoning was strongly suspected based on the victim's clinical manifestation. The product that had been injected into the victim's face was probably polyacrylamide hydrogel-based product, which had been prohibited by the State Food and Drug Administration (SFDA) in China in 2006. To confirm this suspicion, a systematical method was established to differentiate varieties of cosmetic surgery products and identify residential acrylamide.MethodsThe removed objects, original products and a certified reference sample of Restylane® were collected for examination. A direct microscopic examination was applied as a rapid screening method. Fourier transform infrared (FTIR) microspectroscopy analysis was subsequently performed to distinguish the main components from each sample. Automated solid phase extraction, ultra high performance liquid chromatography (SPE UHPLC) analysis was ultimately utilised and optimised to detect the residual acrylamide. Chromatographic separation was achieved on an ACQUITY UHPLC HSS T3 column. The mobile phase consisted of 0.01% aqueous formic acid solution and acetonitrile. The tunable UV (TUV) detection wavelength was at 202 nm.ResultsThe microscopic examination indicated that different samples had different morphological characteristics, depending on their main components. The FTIR spectrum showed that different polymers could be distinguished according to the CO stretching vibration (1655 cm? 1), NH bending vibration (1540 cm? 1) and CO stretching vibration (1078 and 1045 cm? 1). The UHPLC results demonstrated that the calibration curve was linear in the range of 0.5–20.0 μg/mL, with a correlation coefficient of 0.999. The average recoveries of the method were 99–107% with an RSD of 1.6–6.3%. The detection limit was 0.1 μg/mL (S/N = 3). The analytical time was 6 min per sample. Acrylamide was detected in the allegedly Restylane® injection.ConclusionsThis systematical method provides a rapid, accurate and sensitive determination of polyacrylamide and residual acrylamide. The microscopic and FTIR spectroscopic examinations help to verify the existence of polyacrylamide quickly and easily. The optimised SPE UHPLC-TUV method offers a simpler and more sensitive approach to confirm the amount of acrylamide, comparing to the methods in the literature.  相似文献   

7.
For 12 volunteers of a drinking experiment the concentration–time-courses of ethyl sulfate (EtS) and ethanol were simulated and fitted to the experimental data. The concentration–time-courses were described with the same mathematical model as previously used for ethyl glucuronide (EtG). The kinetic model based on the following assumptions and simplifications: a velocity constant kform for the first order formation of ethyl sulfate from ethanol and an exponential elimination constant kel. The mean values (and standard deviations) obtained for kform and kel were 0.00052 h?1 (0.00014) and 0.561 h?1 (0.131), respectively. Using the ranges of these parameters it is possible to calculate minimum and maximum serum concentrations of EtS based on stated ethanol doses and drinking times. The comparison of calculated and measured concentrations can prove the plausibility of alleged ethanol consumption and add evidence to the retrospective calculation of ethanol concentrations based on EtG concentrations.  相似文献   

8.
Recently, different portable hand-held and battery-powered dental X-ray units have become available. Especially for forensic odontological purposes, they offer diverse advantages such as for use in disaster areas and crime-scene locations as also in autopsy rooms and mortuaries. For any application, the most important feature of these hand-held devices is the delivered image quality. The aim of this study is to evaluate the radiographic image quality acquired by two portable X-ray devices in combination with two types of image receptors and to compare the findings with the image quality of a standard intra-oral X-ray device.Eleven samples consisting of eight teeth, two dry skeletal specimens and one formalin-fixed mandible part were mounted on blocks for standardised (re)positioning. Radiological images were acquired with two hand-held (AnyRay® 60 kVp, 0.02–4.00 mAs and NOMAD® 60 kVp, 0.023–2.277 mAs) and one wall-mounted (MinRay® 60/70 kVp 0.14–22.4 mAs) X-ray device combined with two image receptor systems (VistaScan® phosphor storage plate (PSP) and SIGMA® M CMOS Active Pixel technology sensor). The effect of X-ray source-to-object distance (SOD) was checked at 20 cm in conjunction with object to image receptor distances (OIDs) of 0.8 and 2.5 cm. For each parameter setup, the exposure times were run from low till high. An expert consent statement was achieved by agreement of four expert observers selecting the optimal images based on a developed four point quality rating system. Next, a selection of the images was assembled in a set of 198 observation screens and scored by seven observers. The observation screens were designed to compare observer scores, relations between devices, receptors and OIDs and images obtained from the different devices at equal exposure levels (mAs). All results were statistically analysed.Radiological image quality was significantly higher for phosphor plate compared with the CMOS digital receptor system (p < 0.0001). Furthermore, a significantly superior image quality was obtained for OID = 0.8 than for OID = 2.5 (p = 0.039). A significant difference in image quality between the three devices was also established (p = 0.02). The present study demonstrated the feasibility of portable X-ray systems for forensic odontological applications based on rendering optimal image quality, provided an in vitro guideline of optimal parameter settings and offered a radiological image database usable in further research.  相似文献   

9.
Age estimation of an individual whether living or dead is an intimidating task in forensic investigations. Since teeth are more resistant to most peri- and post-mortem changes, they are frequently used for identification and age estimation when skeletal remains are in poor condition. However, most methods are destructive and warrant extraction of teeth which is not feasible in living individuals. Cameriere's et al. put forth a radiographic method of age estimation by pulp to tooth area ratio (AR) in canines and revealed a linear regression between age and the AR. In the present study, we estimated the AR in 456 canines (upper, lower and both) in an Indian sample (114 males and 114 females) using radiovisiography technique. Linear regression equations were derived for upper canine, lower canine and both using the AR to estimate chronological age. Additionally, the efficacy of these equations was also evaluated in younger age group (<45 years). The formulas derived, i.e., age = 96.795 ? 513.561x1 (Eq. (1)) for upper canine, age = 88.308 ? 458.137x2 (Eq. (2)) for lower canine and age = 99.190 ? 283.537x1 ? 306.902x2 + 400.873x1x2 (Eq. (3)) for both the canines were applied to predict the chronological age. The mean value of residuals using these regression equations ranged from 4.28 to 6.39 years with upper canine equation generally giving a precise result. When these equations were applied for younger ages (<45 years), the regression equation derived from both canines gave a better result (mean residual 2.70 years). Overall these equations were better able to predict the age in younger ages, i.e., up to 45 years.  相似文献   

10.
《Science & justice》2014,54(6):451-458
Textile fibres were transferred to the hands of ten living subjects and their persistence was determined after hand washing. Average number of fibres transferred was 300 ± 133 (female 288 ± 92, male 311 ± 163) per 100 cm2 hand area in the 100 experiments. However the number of fibres transferred was not gender dependent but individual dependent. The hand texture of subjects was compared with the number of fibres transferred but the relationship was not observed. The number of fibres transferred varied significantly for the 10 repeated experiments performed under the same conditions for the same subject.The subjects were then asked to wash their hands with water. One test group washed their hands with standing water, and the other with running tap water. Afterwards, the number of fibres remaining on the test subjects' hands were investigated. Migration of the fibres on the surface of the observed hands did occur but total loss of transferred fibre after hand washing did not occur. The average number of fibres remaining per 100 cm2 hand area was 14 ± 10 (range = 3–72) for hand washing with standing water, and 10 ± 12 (range = 0–79) for washing with running tap water. The results of this study show the possibility of finding fibres on the hands of a person involved in a criminal case even after hand washing before fibre collection.  相似文献   

11.
A continual challenge in the field of forensic DNA analysis is the amplification and interpretation of degraded and low-copy number (LCN) DNA obtained from amounts of limited biological evidence. It has been well established that DNA profiles obtained from the amplification of low quality, degraded, and/or LCN DNA samples are often of limited value due to the frequent occurrence of preferential amplification during polymerase chain reaction (PCR). The by-products of preferential PCR amplification are often observed as inter- and intra-locus peak imbalance, allelic dropout, and/or locus dropout. These are all artifacts that are identified during the interpretation phase of analysis rather than by improving the quality of the DNA present. While it is theoretically possible to obtain a complete DNA profile from a single cell, in reality, profiles obtained from suboptimal amounts of DNA are difficult to interpret and frequently inconsistent when replicated. Inspired by advances in next-generation sequencing techniques, we propose a methodology for simultaneously normalizing the abundance of PCR products across all short tandem repeat (STR) loci using the DNA exonuclease, duplex-specific nuclease (DSN). DSN is an enzyme isolated from the hepatopancreas of Red King (Kamchatka) crab that possesses a strong affinity for digesting double stranded DNA (dsDNA) and has limited activity toward single stranded DNA (ssDNA). Degraded DNA known to display peak imbalance and allele dropout was amplified using AmpFlSTR® Identifiler® Plus for 28 cycles. Following amplification, samples were denatured at 99.9 °C for 5 min and incubated with one unit of DSN at 62 °C in a 28 μl volume for 1 min. Nuclease activity was terminated through the addition of equal volume of 10 mM EDTA and 95 °C incubation for 2 min. Following DSN treatment, 21 of 30 alleles within the known profile exhibited some improvement in peak height balance. The findings obtained support the potential use of DSN treatment as a method for normalizing STR profiles and improving the quality of data from degraded and low quantity DNA samples.  相似文献   

12.
A gas chromatography–mass spectrometry (GC–MS) method was developed and validated for the simultaneous qualification and quantification of methamphetamine (MA), amphetamine (AP), 3,4-methylenedioxy-N-methylamphetamine (MDMA), 3,4-methylenedioxy-N-amphetamine (MDA), ketamine (KET) and norketamine (NKT) in fingernails. Fingernail samples (20 mg) were washed with distilled water and methanol, digested with 1.0 M sodium hydroxide at 95 °C for 30 min, and then extracted with ethyl acetate. Extract solutions were evaporated to dryness, derivatized using heptafluorobutyric anhydride (HFBA) at 60 °C for 30 min, and analyzed by GC–MS. The linear ranges were 0.1–20.0 ng/mg for AP, MDMA and NKT, 0.2–20.0 ng/mg for MA and MDA, and 0.4–20.0 ng/mg for KET, with the coefficients of determination (r2  0.9989). The intra- and inter-day precisions were within 7.1% and 10.6%, respectively. The intra- and inter-day accuracies were ?10.9% to 0.8% and ?4.3% to 4.5%, respectively. The limits of detections (LODs) and the limits of quantifications (LOQs) for each analyte were lower than 0.094 ng/mg and 0.314 ng/mg, respectively. The recoveries were in the range of 72.3–94.9%. The average fingernail growth rates of two subjects for three years and six subjects for two months were 3.12 mm/month and 3.16 mm/month, respectively. The method proved to be suitable also for the simultaneous detection and quantification of MA, MDMA, KET and their metabolites in fingernails.  相似文献   

13.
《Science & justice》2014,54(6):421-426
The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC–MS (UHPLC–MS/MS) method and an SPME–GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A — direct injection of 10 μL in UHPLC–MS/MS in positive electrospray ionisation (ESI) mode and B — sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port.The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC–MS/MS and 0.5 ng/mL in SPME–GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC–MS/MS the LLOD was 20 ng/mL.Both methods were applied to 70 samples coming from roadside tests. By SPME–GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL.  相似文献   

14.
《Science & justice》2014,54(1):3-21
An LTQ-Orbitrap FTMS is a new (hybrid) mass spectrometric (MS) analyzer. It allows for the acquisition of full scan MSn (n-stage fragmentations, n = 1  n) spectra with the linear ion trap detector (LTQ) at high speed and/or with the Fourier Transform-detector (Orbitrap) with ultra high mass resolution (> 60,000 at m/z < 400 amu) and high mass accuracy (≤ 1 ppm with internal calibration). In addition it may be coupled with liquid chromatography (LC) with photo diode array (PDA) detection.Two methods for the forensic screening and confirmation of all common trace explosives in post-blast residues have been developed on this instrument using atmospheric pressure chemical ionization (APCI). In one run, the nitrogen-containing explosives are analyzed with the combination of “LC-(PDA)-APCI(−)-LTQ MS2/Orbitrap FTMS” (Method 1). In another run, peroxide explosives are analyzed with “LC-APCI(+)-LTQ MS2/Orbitrap FTMS” (Method 2).The performance of both methods has been validated according to procedures defined in the EU COMMISSION DECISION implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results (DC 2002/657/EC) and other standards (NEN 17025 and NEN 7777). The methods are highly selective due to the simultaneous utilization of the Orbitrap FTMS and LTQ MS2, both of which are highly selective detectors Tested explosive compounds can be detected in the molecular ion form by the Orbitrap analyzer with minimal mass interference in different matrices when using an extremely narrow mass tolerance detection window (≤ 2 ppm). The identification of a detected compound follows an identification point system. Experimental results show that almost all explosive compounds meet the confirmation criteria (minimum 4 points) required for the positive identification by the DC 2002/657/EC.  相似文献   

15.
Many scientists of varying clinical backgrounds have described the phenomenon of spermaturia in animals, adolescents as well as fertile and infertile men. Nevertheless, research for an expert opinion on a law case in the field of forensic medicine revealed a lack of valid information about the longevity of spermatozoa in post-ejaculatory urine (PEU) of fertile men.Our goal was to measure the appearance of vivid sperm in PEU while considering the factor of time in order to predict a realistic interval, in which positive sperm findings might occur. Therefore ten healthy, young men donated their sperm for fertility analysis and a urine sample prior to and after ejaculation. The time intervals between ejaculation and the first micturition were preset ranging between 30 min and maximal 11 h. Each ejaculate underwent a semen analysis. The pre- and post-ejaculatory urine samples were screened for the presence of viable and motile spermatozoa. Semen parameters were determined and related to the sperm findings in the precipitate of the urine samples. The amount, the viability and motility status of the detected spermatozoa were recorded after each preset time interval.The results showed that none of the 10 participants had sperm in their urine samples prior to ejaculation. The average sperm concentration was 50.1 ± 25.8 million/ml. After a time span of 30 min 59.5% of the first fractions of PEU samples were sperm positive, after 2 and 4 h still 70%, and after 5 h sperm were no longer detected. The last motile spermatozoa could be found after 4.5 h. It seems that remaining sperm in the urethra are washed out with the first micturition in the majority of fertile men, however, the conclusion as to whether sperm findings >5 h after ejaculation are improbable needs to be confirmed by further investigations.  相似文献   

16.
Previous studies have documented gender-related differences in a number of aspects of the pharmacology of opiates, including their analgesic activity, stimulative properties and generation of physical dependence. The current experiments were carried out with the aim to examine whether male–female differences exist in the blood and brain levels of opiates attained after their intraperitoneal injection to male and female Wistar rats. The tests were performed 5, 15, 45 and 120 min after the animal treatment with seized heroin. Gas chromatography–mass spectrometry (GC–MS) method was developed to quantitatively determine opiate alkaloids in blood and brain regions (known for their high concentration of μ-opiate receptors): cortex, brainstem, amygdala and basal ganglia. Maximal contents of opiates in blood of animals of both genders were found in the second measurement time (15 min), the values measured in the males being significantly higher, which suggests a faster passage of the opiates from blood to brain tissue in female animals. The highest content of opiates in the brain tissue of female animals was measured 15 min and with male animals 45 min after the treatment, which also indicates faster distribution of opiates from blood to brain in the female compared to male rats. The highest proportion of opiates was found in the basal ganglia of the animals of both genders. The obtained results offer the possibility of selecting this part of the brain tissue of both males and females as a representative sample for identifying and assessing contents of opiates.  相似文献   

17.
PCR amplification of tetrameric short tandem repeats (STRs) can lead to Taq enzyme slippage and artefact products typically one repeat unit less in size than the parent STR. These back stutter or n ? 4 amplification products are low-level relative to the amplification of the parent STR but are widely seen in the forensic community where tetrameric STRs are employed in the generation of DNA profiles. To aid the interpretation of DNA mixtures where minor contributor(s) might be present in comparable amounts to the back stutter products, the typical amounts of back stutter generated have been well characterised and guidelines for interpretation are in place. However, further artefacts thought to be Taq enzyme slippage leading to products with one repeat unit greater than the parent sequence (n + 4 or forward stutter) or two repeats less (n ? 8 or double back stutter) also occur, but these have not been well characterised despite their potential influence in mixture interpretations. Here we present findings with respect to these additional artefacts from a study of 10,000 alleles and include guidelines for interpretation.  相似文献   

18.
The study of decaying organisms and death assemblages is referred to as forensic taphonomy, or more simply the study of graves. This field is dominated by the fields of entomology, anthropology and archaeology. Forensic taphonomy also includes the study of the ecology and chemistry of the burial environment. Studies in forensic taphonomy often require the use of analogues for human cadavers or their component parts. These might include animal cadavers or skeletal muscle tissue. However, sufficient supplies of cadavers or analogues may require periodic freezing of test material prior to experimental inhumation in the soil. This study was carried out to ascertain the effect of freezing on skeletal muscle tissue prior to inhumation and decomposition in a soil environment under controlled laboratory conditions. Changes in soil chemistry were also measured. In order to test the impact of freezing, skeletal muscle tissue (Sus scrofa) was frozen (?20 °C) or refrigerated (4 °C). Portions of skeletal muscle tissue (~1.5 g) were interred in microcosms (72 mm diameter × 120 mm height) containing sieved (2 mm) soil (sand) adjusted to 50% water holding capacity. The experiment had three treatments: control with no skeletal muscle tissue, microcosms containing frozen skeletal muscle tissue and those containing refrigerated tissue. The microcosms were destructively harvested at sequential periods of 2, 4, 6, 8, 12, 16, 23, 30 and 37 days after interment of skeletal muscle tissue. These harvests were replicated 6 times for each treatment. Microbial activity (carbon dioxide respiration) was monitored throughout the experiment. At harvest the skeletal muscle tissue was removed and the detritosphere soil was sampled for chemical analysis. Freezing was found to have no significant impact on decomposition or soil chemistry compared to unfrozen samples in the current study using skeletal muscle tissue. However, the interment of skeletal muscle tissue had a significant impact on the microbial activity (carbon dioxide respiration) and chemistry of the surrounding soil including: pH, electroconductivity, ammonium, nitrate, phosphate and potassium. This is the first laboratory controlled study to measure changes in inorganic chemistry in soil associated with the decomposition of skeletal muscle tissue in combination with microbial activity.  相似文献   

19.
《Science & justice》2014,54(6):459-464
Using a desorption/ionization technique, easy ambient sonic-spray ionization coupled to mass spectrometry (EASI-MS), documents related to the 2nd generation of Brazilian Real currency (R$) were screened in the positive ion mode for authenticity based on chemical profiles obtained directly from the banknote surface. Characteristic profiles were observed for authentic, seized suspect counterfeit and counterfeited homemade banknotes from inkjet and laserjet printers. The chemicals in the authentic banknotes' surface were detected via a few minor sets of ions, namely from the plasticizers bis(2-ethylhexyl)phthalate (DEHP) and dibutyl phthalate (DBP), most likely related to the official offset printing process, and other common quaternary ammonium cations, presenting a similar chemical profile to 1st-generation R$. The seized suspect counterfeit banknotes, however, displayed abundant diagnostic ions in the m/z 400–800 range due to the presence of oligomers. High-accuracy FT-ICR MS analysis enabled molecular formula assignment for each ion. The ions were separated by 44 m/z, which enabled their characterization as Surfynol® 4XX (S4XX, XX = 40, 65, and 85), wherein increasing XX values indicate increasing amounts of ethoxylation on a backbone of 2,4,7,9-tetramethyl-5-decyne-4,7-diol (Surfynol® 104). Sodiated triethylene glycol monobutyl ether (TBG) of m/z 229 (C10H22O4Na) was also identified in the seized counterfeit banknotes via EASI(+) FT-ICR MS. Surfynol® and TBG are constituents of inks used for inkjet printing.  相似文献   

20.
For nearly 30 years, the methods utilized in illicit cocaine hydrochloride production have remained relatively consistent. Cocaine hydrochloride is typically produced one kilogram at a time. As a result, each individual kilogram is unique and distinct from other kilograms in any particular seizure based on the total alkaloid profile, occluded solvent profile, and isotopic signature. Additionally, multi-kilogram cocaine seizures are often comprised of cocaine from several different coca growing regions. There has been a documented shift in this type of processing based on the recent analysis of a large cocaine seizure in the Eastern Pacific. Signature analyses of samples from 21 kg randomly selected from a 517 kg seizure were virtually identical. Triplicate analyses of each sample via gas chromatography with flame ionization detection, static headspace gas chromatography mass spectrometry, and isotope ratio mass spectrometry were completed. An initial outlier evaluation of the data and an in-depth univariate analysis indicated there was no statistically significant difference among the 21 samples at the 95% confidence interval. Principal components analysis did reveal consistent minor deviations between the samples and known authentic data from the Nariño coca growing region of Colombia. These deviations were only observed on the latter principal components and could be explained by differences in solvent selection during cocaine hydrochloride processing. Chemical analyses in addition to a thorough statistical evaluation suggest a shift in the traditional small-batch method of cocaine processing to a multi-kilogram, high throughput approach.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号