首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Saliva and saliva-stained materials were examined as potential sources of deoxyribonucleic acid (DNA) for DNA analysis and identity testing. In this paper, the authors demonstrate that DNA was isolated and DNA banding patterns suitable for DNA typing were obtained from fresh saliva and various saliva-stained materials, such as envelopes, buccal swabs, gags, and cigarettes. Furthermore, DNA and DNA banding patterns were obtained from actual forensic evidentiary samples containing mixed saliva/semen stains. The DNA banding patterns obtained from saliva or saliva-stained material were indistinguishable from the patterns obtained from blood or hair from the same individual. Intact DNA was readily isolated and DNA banding patterns were obtained from saliva stored at -20 degrees C and dried saliva stains stored under varying conditions. We conclude that saliva and saliva-stained material can be good sources of DNA for analysis and for DNA typing in certain forensic settings.  相似文献   

3.
Low nanogram quantities of amphetamine were detected in 100μl samples of dried bloodstains using radioimmunoassay. Saliva, saliva stains, semen, and seminal stains also contained measurable quantities of the drug.  相似文献   

4.
In this study we examined the presence of cannabinoids in saliva samples obtained from 24 drug-abusers. The saliva specimens were collected by "EPITOPE" system and the subsequent elution of samples was achieved by centrifugation. The resulting ultrafiltrates have been directly sampled with solid phase micro-extraction (SPME) and then analyzed by GC/MS. Saliva sampling is less invasive than collection of blood.  相似文献   

5.
Fluorescence spectra of sebum-rich latent fingerprints were studied with a tunable laser for non-destructive fingerprint detection without chemical treatment. The tunable laser consists of a nanosecond pulsed Nd-YAG laser and an optical parametric oscillator (OPO) crystal. The fluorescence spectra and images were measured at various excitation wavelengths in the ultraviolet region by the time-resolved fluorescence method. We have previously reported that a typical fluorescence spectrum of fingerprints consists of two peaks located at c. 330 and 440 nm. In order to determine the wavelength of optimal excitation, excitation spectra were measured at wavelengths ranging from 220 to 310 nm. The fluorescence intensity of the 330 nm peak became maximal with excitation at 280 nm. The images of latent fingerprints on white papers were also measured and the clearest image was obtained with excitation at 280 nm. The influence of continuous irradiation on the fluorescence of fingerprints was measured at the optimal excitation wavelengths. The 330 nm peak was strong at first and decreased with continuous irradiation, whereas the 440 nm peak, which was weak at first, increased gradually.  相似文献   

6.
唾液及含唾液检材的DNA分析   总被引:1,自引:0,他引:1  
提取160份唾液及含唾液的检材中的DNA,并根据DNA的质和量进行了DNA指纹图检验或应用聚合酶链反应(PCR)进行了DNA分型。结果表明,唾液和含唾液检材是很好的DNA来源.对其进行DNA分析是可行的。  相似文献   

7.
The purpose of the present study was to identify salivary molecules carrying the ABH blood group antigens in Koreans and to investigate the changes in these antigens according to processing and storage of saliva samples. Secretor or non-secretor phenotypes and salivary components carrying the ABH antigens were identified in 90 subjects, 30 subjects in each ABO blood group, by SDS-PAGE and immunoblotting. Saliva samples were then obtained from 12 secretors-two males and two females in each ABO blood group and aliquots of both fresh saliva samples and their supernatants after centrifugation were stored at room temperature, 4, -20 and -70 degrees C. The same experiments were performed after 1, 3 and 6 months to investigate changes in the blood group antigens. In all 68 secretors, high-molecular-weight salivary mucin (MG1) was found to be the primary carrier of the ABH antigens. A salivary component of approximately 80 kDa also carried H antigen in seven saliva samples of 22 blood type O secretors. The blood group antigens were better detected in centrifuged samples. In saliva samples preserved at room temperature and 4 degrees C, the blood group antigens were either not detected or detected as degraded molecules. No change was found in the blood group antigens in saliva samples preserved at -20 and -70 degrees C for 6 months.  相似文献   

8.
The results presented demonstrate the capacity for spectral enhancement to substantially improve the forensic examination of footwear impressions in blood treated with leucocrystal violet (LCV). The UV-Vis absorption spectra were generated of (i) an aqueous solution of leucocrystal violet, (ii) leucocrystal violet in 3% H(2)O(2), (iii) LCV working solution and (iv) whole blood added to LCV working solution. The resultant fluorescence emission spectra were subsequently generated (lambda(ex)=630nm, lambda(em)=661-900nm). The results indicate that the UV-Vis absorption spectra of an unbuffered solution of whole blood with LCV working solution produces a strong absorbance curve with a maxima at 630nm. Subsequent excitation at this wavelength and generation of the emission spectrum in the fluorescence mode indicates that a solution of whole blood added to LCV working solution is an extremely weak fluorophore. Therefore, to enable an adequate and timely enhancement of blood impression evidence treated with LCV utilising either visible fluorescence or infrared luminescence requires (i) selection of the most appropriate excitation wavelength (lambda(ex)) and emission wavelength (lambda(em)) with extremely narrow band pass filters, which in the absence of substrate matrix interference is excitation at 630nm producing the emission maxima at 665nm and (ii) a visual enhancement system such as a CCD colour IR video camera with image integration.  相似文献   

9.
DNA profiles were generated via direct amplification from blood and saliva samples deposited on various types of swab substrates. Each of the six non-FTA substrates used in this research was punched with a Harris 1.2 mm puncher. After 0.1 μL of blood or 0.5 μL saliva, samples were deposited on each of these punches, samples were pretreated with one of four buffers and washing reagents. Amplification was performed using direct and nondirect autosomal and Y-STR kits. Autosomal and Y-STR profiles were successfully generated from most of these substrates when pretreated with buffer or washing reagents. Concordant profiles were obtained within and between the six substrates, the six amplification kits, and all four reagents. The direct amplification of substrates which do not contain lysing agent would be beneficial to the forensic community as the procedure can be used on evidence samples commonly found at crime scenes.  相似文献   

10.
The present work aimed to study the detection, through lateral flow immunochromatographic (LFI) tests, of saliva samples over time in three different types of fabrics, as well as, the possibility of DNA isolation and characterization from the sample tubes and the cassettes. Fifty microliters of saliva (three samples/time) were deposited in denim, cotton, and polyester. Saliva was identified by SERATEC® Amylase Test and the Crime Scene version SALIVA CS, being able to detect it up to six months of deposition, although with different band intensities. Polyester showed stronger bands than cotton, probably due to its synthetic nature, and denim, as an inked fabric, showed less band intensities. Statistical analyses confirmed significant differences among fabrics, but not over time in the same type of fabric. Total DNA from the sample tubes was successfully recovered, in contrast, from the cassettes, only polyester retrieved amplifiable DNA. These findings indicated that it is possible to recover and identify saliva up to six months after deposition, also obtaining DNA. Future research will be able to expand these results, analyzing the stability of other body fluids, and the sensitivity of lateral flow immunochromatographic tests to detect them.  相似文献   

11.
Latent fingerprints were successfully visualized using fluorescence lifetime imaging (FLIM) on paper which emits strong fluorescence with a lifetime close to that of fingerprints and thus from which it is difficult for time-resolved spectroscopy to visualize fingerprints. Latent fingerprint samples on paper were excited using a 450 nm or 532 nm nanosecond pulsed-laser, and time-resolved fluorescence images were obtained at a delay time of 6–16 ns in intervals of 1 ns, to the excitation pulse. The excitation beam was expanded using a lens, and the fluorescence from the fingerprints was captured using an intensified CCD camera. Because of the large fluorescence intensity of the background paper of approximately two to four orders of magnitude larger than that of the fingerprint, the fingerprint was not visualized on each fluorescence image by time-resolved spectroscopy. However, the fingerprint was visualized in a FLIM image constructed using a series of the fluorescence images for the case with the fluorescence intensity of the background paper being four orders of magnitude larger than that of the fingerprint. The difference in fluorescence lifetime in the FLIM image of the visualized fingerprint and background paper was in the order of 0.1 ns, which was an order of magnitude smaller than the inherent fluorescence lifetime of a few nanoseconds for the fingerprints and paper. It was demonstrated that, at a background fluorescence intensity with a certain order of magnitude larger than that of fingerprints, FLIM has the potential to visualize latent fingerprints which cannot be visualized by time-resolved spectroscopy.  相似文献   

12.
Laser detection of latent fingerprints on a white paper has been performed, previously. Ultraviolet fluorescence from various kinds of printer toner and ink used for home printers were measured to study fluorescence imaging of fingerprints on a color-printed white paper. The experimental system consisted of a nanosecond pulsed tunable laser and a cooled CCD camera. Excitation wavelengths are 230 and 280 nm. Fourteen printers consisting of three color laser printers, three color inkjet printers, five monochrome laser printers, two monochrome copy machines, and a color copy machine were tested. Toner and ink of most printers exhibited fluorescence in the region from 360 to 550 nm. In most cases, clear fluorescence images were obtained by time-resolved imaging with a band-pass filter and 280-nm excitation. However for toners from laser color printers that showed strong fluorescence, better results were obtained with 230-nm excitation. Latent fingerprints on a photograph page and a black-character page of a newspaper were also imaged.  相似文献   

13.
Vaginally inserted plastic tampon applicators were obtained from 42 female volunteers. The applicators were examined for the presence of ABH blood group substances, phosphoglucomutase (PGM), amylase, acid phosphatase, P30, and intact spermatozoa. Each applicator was accompanied by a control blood sample, a saliva specimen, a brief sexual and menstrual history, and method of birth control of the donor. Eight of the male sexual partners of the donors submitted blood and saliva samples. One male sexual partner submitted only a saliva sample. ABH blood group substances corresponding to the donor were recovered from 36 of the 42 applicators. The remaining 6 applicators revealed a combination of the donor's and sexual partner's ABH substances. The female's PGM type was recovered from 34 of the applicators. The remaining 8 applicators failed to show PGM activity. Of the applicators, 15 indicated evidence of prior sexual intercourse by the detection of ABH substances not consistent with the applicator donor (6 samples), high levels of acid phosphatase (11 samples), or recovery of spermatozoa (8 samples) or some combination of these. All applicator samples failed to show the presence of either P30 activity or PGM factors foreign to the female.  相似文献   

14.
Fingerprints deposited at crime scene can be a source of DNA. Previous reports on the effects of fingerprint enhancement methods have focused mainly on fingermarks deposited in blood or saliva. Here, we evaluate the effects of fingerprint enhancement methods on fingerprints deposited on porous surfaces. We performed real‐time quantification and STR typing, the results of which indicated that two methods (iodine fuming and 1,2‐indanedione in ethyl acetate enhancement) had no effect on the quantity of DNA isolated and resultant STR alleles when compared to control samples. DNA quantities and allele numbers were lower for samples enhanced with silver nitrate and 1,2‐indanedione in acetic acid when compared to control samples. Based on DNA quantity, quality, and observable stochastic effects, our data indicated that iodine fuming and 1,2‐indanedione in ethyl acetate were the preferred options for the enhancement of fingerprints on porous surfaces.  相似文献   

15.
胺端基型CdS/PAMAM潜在显现指印的应用   总被引:1,自引:0,他引:1  
目的探索一种新型纳米荧光材料的制备方法及其在潜在指印显现方面的应用前景。方法以聚酰胺-胺(PAMAM)树形分子为模板,原位合成CdS纳米簇。并使用荧光光谱法对产物进行表征:应用这种新型荧光材料对多种客体表面、不同陈旧程度的潜在指印进行显现.并将显现结果与传统荧光染料进行比对。结果该荧光材料在365nm紫外光激发下可以发出很强的可见荧光:与传统的荧光染料相比。-NH2端基型CdS/PA—MAM可以同指印残留物进行靶向结合.其荧光强度高、背景干扰小,指印纹线与客体反差大。结论-NH2端基型CdS/PAMAM可以有效地显出非渗透性客体表面的潜在指EP。  相似文献   

16.
Saliva plus DNA from a suspect is commonly encountered in sexual assault cases on bodily swabs. However, without background knowledge, the weight of this evidence is unknown. It may indicate the presence of saliva resulting from cunnilingus, or it may represent indirect transfer. In this study, females who refrained from cunnilingus donated 43 items of underwear and 19 vaginal swabs. The samples were subjected to Phadebas®, RSID-Saliva and mRNA profiling and were subsequently DNA-profiled to determine the prevalence of background saliva in the female population. The results report that 15.8% of females who refrained from cunnilingus were positive for saliva and a further 10.5% also had DNA from unknown source(s). These findings of the rate of indirect transfer were evaluated with the Bayesian approach, and it was found that the evidence of saliva plus a high foreign DNA source adds moderately strong support to the allegation of cunnilingus.  相似文献   

17.
Abstract: Salivary DNA is encountered in many crimes, such as sexual assaults and murders. In this study, saliva from three male donors was deposited on the skin of three female recipients. The amount of male salivary DNA remaining on the female skin was measured over a 96‐h period using the Quantifiler? Y Human Male DNA Quantification Kit. In eight of the nine experiments, a full male DNA profile matching the donor was obtained even after 96 h. In addition, the study showed that the concentration of salivary DNA varied from donor to donor and from day to day. The efficiency of two recovery methods, wet and dry swabbing and minitaping, was compared. The results indicate the tapelift method gave higher DNA recovery. This study also examined the secondary transfer of salivary DNA from skin to fabrics. Cotton and polyester give higher DNA transfer than leather.  相似文献   

18.
This study aims to show that sensitive detection of ethyl glucuronide in dried blood spotted onto various surfaces after a period of 24h is feasible. At present, there is insufficient information how tightly ethyl glucuronide (EtG) binds to various materials and how easily it can be eluted. 4ml aliquots of blood samples obtained from seven volunteers after consumption of alcoholic beverages were applied to six different surfaces. After drying and a 24h-storage at 20±2°C the samples were re-dissolved in water, and EtG was subsequently analyzed by a LC-MS Paul-type ion trap. A comparison was made between dried and corresponding fluid samples. EtG was detectable in all subjects' samples following consumption of alcohol. EtG was also detectable after a storage time of four weeks at 4°C in whole blood that had been preserved with EDTA. EtG was detectable in all samples dried on different surfaces and its concentration remained relatively constant irrespective of the particular condition of the material. Detection of EtG in blood spots from the scene may indicate recent alcohol consumption in cases where collection of blood remained undone or could not be performed.  相似文献   

19.
《Science & justice》2023,63(3):414-420
The identification of biological fluids or materials in forensic samples is a key requirement in forensic science that relies on chemical and biological based tests, most of which exhibit false positivity. When reporting results from such tests, Forensic Scientists use words such as probable, possible, and likely, without always being able to provide robust support for these conclusions. In collating information about false positive rates for a number of these tests, we found limited research into the cross reactions observed from ‘other’ biological samples in commonly encountered case sample stains. By ‘other’ we mean biological fluids or materials that are not the primary target of the presumptive test being used. Here we carry out a specificity study to fill gaps in the literature for a number of the presumptive chemical, biological and immunochromatographic tests used to presumptively screen for blood, semen and saliva. The tests selected for this study are the widely used tests: Luminol, TMB/Combur3 Test® E, Kastle-Meyer (KM), RSID™ - Blood, ABAcard® HemaTrace®, Acid Phosphatase (AP), ABAcard® p30, RSID™ - Semen, Phadebas® ‘Tube’ Test, Phadebas® ‘Press’ Test, and RSID™ - Saliva tests. Specificity for each of these was tested in known samples, from volunteers, of blood, semen, saliva, urine, sweat, vaginal material, faeces and breast milk, and then false positive rates were determined.  相似文献   

20.
We previously reported that detection of Streptococcus salivarius is feasible for proving the presence of saliva in a forensic sample. Here, a simple and rapid method for the detection of S. salivarius in forensic samples was developed that uses loop-mediated isothermal amplification (LAMP). The LAMP primer set was designed using S. salivarius-specific sequences of glucosyltransferase K. To simplify the procedure, the sample was prepared by boiling and mutanolysin treatment only, and the entire analytical process was completed within 2.5 h. The cut-off value was set at 0.1 absorbance units, measured at 660 nm, upon termination of the reaction. S. salivarius was identified in all saliva samples, but was not detected in other body fluids or on the skin surface. Using this method, S. salivarius was successfully detected in various mock forensic samples. We therefore suggest that this approach is useful for the identification of saliva in forensic practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号