首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of methodologies using inexpensive, fast, and reliable instrumention is desirable in illicit drug analysis. The purpose of this study was based on cyclic voltammetry technique to differentiate the electrochemical behavior of ?9‐THC, the psychoactive substance in marijuana, and five different extract plants to yield false positive results after analysis protocol for cannabinoids using thin‐layer chromatography and Fast Blue B salt. After applying a deposition potential of ?0.5 V in a glassy carbon working electrode, the results indicated an anodic peak current at 0.0 V versus Ag/AgCl after addition of ?9‐THC solution in the electrochemical cell, and limits of detection and quantification were 1.0 ng mL?1 and 3.5 ng mL?1, respectively. Other interfering plants showed distinct amperometric responses. This methodology was useful to detect ?9‐THC even in the presence of the Fast Blue B salt, which avoided false positive results for all the studied extract plants.  相似文献   

2.
The aim of this study was to clarify whether positive results for prostate‐specific antigen (PSA) and acid phosphatase (AP) occur in postmortem swabs from the genito‐anal region in males (n = 80; 4 regions) and females (n = 20; 3 regions) and to calculate the positive predictive value (PPV) concerning the presence of spermatozoa. In male subjects, the highest incidence of positive test results was found in urethral swabs (PSA 76%, AP 71%) and the lowest frequencies appeared in perianal and rectal swabs (15–20%). Microscopic evaluation for spermatozoa was positive between 39% in urethral swabs and 1% in rectal swabs. PPV regarding positive identification of spermatozoa was 33.3% for PSA and 31.5% for AP. The combination of both tests yielded a PPV of 38.2%. In female cases, no spermatozoa were identified, and one case was PSA‐ and AP‐positive in perianal swabs. Our findings indicate that PSA and AP tests are of limited value for the postmortem detection of spermatozoa in male subjects.  相似文献   

3.
目的检测人体不同体液内前列腺特异抗原(PSA)含量,探讨其法医学价值。方法收集成年人(19~63岁)晨尿40份(男28份、女12份)、血液58份(男45份、女13份)、唾液25份(男14份、女11份);青少年(10~15岁)男性晨尿205份;哺乳期(25~31岁)女性乳汁9份;使用Cobas e411型全自动电化学发光免疫分析系统及T-PSA定量测定试剂盒,检测各样本T-PSA含量;分析不同体液及不同年龄青少年男性尿液PSA含量差异。结果除男、女性唾液外,其它样本均可检测到PSA,其中成年男性尿液含量最高,与其它体液比较具有显著性差异(P<0.000 1);青少年男性各年龄组尿液PSA含量随年龄逐年增高,11岁及以下年龄组含量不足1ng/mL,14岁及以上年龄组可超过1 000ng/mL。结论前列腺发育成熟的男性尿液PSA含量较高,在进行精液斑的法医学检验时应给予充分注意。  相似文献   

4.
Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR‐FT‐IR spectroscopy, the risk for false‐positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer‐applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection.  相似文献   

5.
Abstract: Use of immunochromatographic membranes for the detection of prostate‐specific antigen (PSA) has become commonplace in forensic laboratories. Experiments were designed to test the newly developed Seratec® SeraQuant? for accuracy, precision, and consistency in the quantitation of PSA. PSA standards were diluted with buffers and run on the instruments. Values obtained were examined for accuracy (was the correct value obtained?) and precision (were multiple sample values consistent?). To test for variation between instruments, large volumes of diluted PSA standard were run repeatedly on six units and the values obtained were plotted against the known PSA values to obtain a standard curve for each instrument. Fifty membranes having negative or weak positive results were then run on the six units, and the adjusted values were recorded and compared. Results of these experiments indicate that the instruments are accurate and precise in the quantitation of low levels of PSA.  相似文献   

6.
Abstract: Tests for the identification of semen commonly involve the microscopic visualization of spermatozoa or assays for the presence of seminal markers such as acid phosphatase (AP) or prostate‐specific antigen (PSA). Here, we describe the rapid stain identification kit for the identification of semen (RSID?‐Semen), a lateral flow immunochromatographic strip test that uses two antihuman semenogelin monoclonal antibodies to detect the presence of semenogelin. The RSID?‐Semen strip is specific for human semen, detecting <2.5 nL of semen, and does not cross‐react with other human or nonhuman tissues tested. RSID?‐Semen is more sensitive with certain forensic evidence samples containing mixtures of vaginal secretions and semen than either of the commercially available PSA‐based forensic semen detection tests or tests that measure AP activity that were tested in parallel. The RSID?‐Semen kit also allows sampling a fraction of a questioned stain while retaining the majority of the sample for further processing through short tandem repeat analysis.  相似文献   

7.
Assigning the gender of a DNA contributor in forensic analysis is typically achieved using the amelogenin test. Occasionally, this test produces false‐positive results due to deletions occurring on the Y chromosome. Here, a four‐marker “YFlag” method is presented to infer gender using single‐base extension primers to flag the presence (or absence) of Y‐chromosome DNA within a sample to supplement forensic STR profiling. This method offers built‐in redundancy, with a single marker being sufficient to detect the presence of male DNA. In a study using 30 male and 30 female individuals, detection of male DNA was achieved with c. 0.03 ng of male DNA. All four markers were present in male/female mixture samples despite the presence of excessive female DNA. In summary, the YFlag system offers a method that is reproducible, specific, and sensitive, making it suitable for forensic use to detect male DNA.  相似文献   

8.
In a case of robbery in which the criminals passed through the garden adorned with calamondin trees (Citrus madurensis), the investigators found in the grass six calamondin fruits, some undamaged, while others apparently bitten. The fruits were collected and sent to the laboratory for DNA analysis to verify the presence of saliva and robbers' DNA profile. A specific immunochromatographic strip test for saliva confirmed the presence of human salivary α‐amylase, but similar positive results were also observed for intact calamondin and other citrus fruits. Further analysis with a specific automated amylase test confirmed the absence of amylase activity. DNA quantification and typing using a specific forensic kit revealed no human DNA presence in any fruits. This case report demonstrates for the first time the occurrence of false positives when human saliva is sought on citrus fruits.  相似文献   

9.
The aim of this study was to develop chemical improvements to the original Weber protocol, in order to increase the intensity and time length of light emission and to eliminate false‐positive reactions. The intensity and duration of light were measured on serial blood dilutions using a plate reader chemiluminometer. Blood stains of various concentrations were impregnated in pure cellulose, dried, and luminol solution was added with/without the potential enhancers. An in silico study was also conducted, aiming to demonstrate the enhancing mechanism of hemoglobin denaturation using 8 M urea. The luminol blood detection test revealed important improvements after urea pretreatment or in the presence of monochloro‐triazinyl‐β‐cyclodextrin. This approach also eliminated the false‐positive reaction from sodium hypochlorite. These improvements could provide a higher sensitivity under particular circumstances such as old or washed blood stains, leading to a better localization for further DNA typing and higher quality photographic analysis.  相似文献   

10.
Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618‐10 standard method. A multistep classification procedure was tested by cross‐validation based on model data sets comprised of the time‐averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory‐scale and field test burns were also used to test the model. The optimal model's true‐positive rate was 81.3% for cross‐validation samples and 70.9% for fire debris samples. The false‐positive rate was 9.9% for cross‐validation samples and 8.9% for fire debris samples.  相似文献   

11.
Isoscape refinement is an essential component for accurately predicting region‐of‐origin in forensic investigations involving isotope analysis of unidentified human remains. Stable oxygen (δ18O) and hydrogen (δ2H) isotopes were measured from 57 tap water samples collected across Mississippi to model refined isoscapes for the state. A tap water conversion equation, δ18Otw=1.64 δ18Op?31.35, was developed for the southeastern USA to test the prediction accuracy of the δ18Otw isoscape using individuals with known residential histories. A local Mississippi resident (USAFA‐134) was assigned with 90% probability to the correct region‐of‐origin reported by the participant. Assignments for Georgia residents (USAFA‐118 and USAFA‐205) had variable results, predicting USAFA‐118 from Mississippi and USAFA‐205 as a nonlocal resident. Stable isotope values often overlap geographically and a multi‐isotope approach should be used when narrowing region(s)‐of‐origin(s). This study demonstrates the utility of refining isoscapes and the importance of tissue calibration in prediction assignments of human remains.  相似文献   

12.
13.
Abstract:  The detection of prostate-specific antigen (PSA) and visualization of spermatozoa from forensic-type samples containing semen exposed to simulated gastric juice was investigated as a support for forensic practice. Samples of simulated gastric juice mixed with semen were prepared and incubated for up to 4 h at 37°C. Samples were deposited on cotton cloth and on ceramic plates and allowed to dry. The samples were examined for the presence of PSA using the Seratec® PSA Semiquant immunochromatographic membrane test. Microscope slides were prepared, stained, and analyzed for spermatozoa. Spermatozoa were detected in all samples, and PSA was detected on neat samples and on samples from the ceramic plate after incubation for up to 4 h. PSA was not detected in the samples deposited on cotton cloth at incubation times greater than 15 min. This may serve as a support for examinations performed when vomit or vomit-stained evidence is submitted for analysis.  相似文献   

14.
The stability of salivary α‐amylase is a critical factor in both catalytic and immunological method‐based forensic saliva identification. This study aimed to assess the sensitivity of catalytic and immunological tests on degraded saliva samples. Degraded saliva stains were prepared by microbial decomposition using humid soil. Salivary α‐amylase activity was catalytically detected both qualitatively and quantitatively using the Phadebas® amylase test. As immunological methods, we conducted qualitative and quantitative tests using the RSID?‐saliva test and ELISA, respectively. Salivary α‐amylase activity of degraded samples (incubated at 37°C for 12 h) was significantly lower than that of controls in the quantitative tests. All the degraded samples obtained by the humid soil produced negative results in the Phadebas® tests, but showed positive results in the RSID?‐saliva test and ELISA. These results suggest that immunological tests are effective for testing degraded saliva samples that have lost their enzymatic activity.  相似文献   

15.
Abstract: The Food and Drug Administration does not require surgical sutures to be tracked by manufacturer, physician, or patient; thereby, surgical sutures have been of little use to forensic practitioners who are tasked with establishing a positive identification with biological evidence. This study demonstrates the investigative process used to pinpoint suture manufacturers by presenting a case where surgical sutures were a distinctive characteristic that aided in the positive identification of skeletal remains. The suture’s manufacturer, construction material and structure, size, and medical use was determined by contacting a local surgical suture and orthopedic implant manufacturer and utilizing publicly available manufacturer websites, which provide catalogs and specific product details. This research was one of many lines of evidence used to establish the positive identification of a 47‐year‐old male.  相似文献   

16.
Abstract: Blood‐borne viral infections are widespread among injecting drug users; however, it is difficult to include these patients in serological surveys. Therefore, we developed a national surveillance program based on postmortem testing of persons whose deaths were drug related. Blood collected at autopsy was tested for anti‐HBc, anti‐HBs, anti‐hepatits C virus (HCV), or anti‐human immunodeficiency virus (HIV) antibodies using commercial kits. Subsets of seropositive samples were screened for viral genomes using sensitive in‐house and commercial polymerase chain reaction (PCR) assays. Hepatitis B virus (HBV) DNA was detected in 20% (3/15) of anti‐HBc‐positive/anti‐HBs‐negative samples, HCV RNA was found in 64% (16/25) of anti‐HCV‐positive samples, and HIV RNA was detected in 40% (6/15) of anti‐HIV‐positive samples. The postmortem and antemortem prevalences of HBV DNA and HCV RNA were similar. Postmortem HIV RNA testing was less sensitive than antemortem testing. Thus, postmortem PCR analysis for HBV and HBC infection is feasible and relevant for demonstrating ongoing infections at death or for transmission analysis during outbreaks.  相似文献   

17.
Short tandem repeats (STR)s have been the eligible markers for forensic animal genetics, despite single‐nucleotide polymorphisms (SNP)s became acceptable. The technology, the type, and amount of markers could limit the investigation in degraded forensic samples. The performance of a 32‐SNP panel genotyped through OpenArraysTM (real‐time PCR based) was evaluated to resolve cattle‐specific forensic cases. DNA from different biological sources was used, including samples from an alleged instance of cattle rustling. SNPs and STRs performance and repeatability were compared. SNP call rate was variable among sample type (average = 80.18%), while forensic samples showed the lowest value (70.94%). The repeatability obtained (98.7%) supports the used technology. SNPs had better call rates than STRs in 12 of 20 casework samples, while forensic index values were similar for both panels. In conclusion, the 32‐SNPs used are as informative as the standard bovine STR battery and hence are suitable to resolve cattle rustling investigations.  相似文献   

18.
This is the first report on development of a library search‐based screening system for 3,4‐methylenedioxymethamphetamine (MDMA) in ecstasy tablets using a portable near‐infrared (NIR) spectrometer. The spectrum library consisted of spectra originating from standard substances as well as mixtures of MDMA hydrochloride (MDMA‐HCl) and diluents. The raw NIR spectra were mathematically pretreated, and then, a library search was performed using correlation coefficient. To enhance the discrimination ability, the wavelength used for the library search was limited. Mixtures of MDMA‐HCl and diluents were used to decide criteria to judge MDMA‐positive or MDMA‐negative. Confiscated MDMA tablets and medicinal tablets were used for performance check of the criteria. Twenty‐two of 27 MDMA tablets were truly judged as MDMA‐positive. Five false‐negative results may be caused by compounds not included in the library. No false‐positive results were obtained for medicinal tablets. This system will be a useful tool for on‐site screening of MDMA tablets.  相似文献   

19.
Analyzing and identifying skeletal remains becomes increasingly difficult when remains have been cremated, especially in cases where the cremated material may have been intentionally contaminated with nonskeletal material. This study examined the potential of X‐ray fluorescence spectrometry (XRF) to detect the presence of nonskeletal contaminants in samples of cremains. Eleven samples of cremains were variably combined with concrete mix and analyzed using XRF. Photon counts of elements in each sample were analyzed, and the coefficient of determination (R2) using unweighted linear regression as a function of percent cremains was calculated. Results showed that with changes in the proportion of skeletal material and contaminant, there were significant (R2 > 0.90) changes in detected levels of phosphorus, potassium, zinc, aluminum, and sulfur. The use of XRF is concluded to be a valid approach in the identification of the presence of nonskeletal material in potentially contaminated cremains.  相似文献   

20.
Seminal fluid represents a common biological material recovered from sexual assault crime scenes. Such samples can be prescreened using different techniques to determine cell type and relative amount before submitting for full STR profiling. The ParaDNA® Screening System is a novel forensic test which identifies the presence of DNA through amplification and detection of two common STR loci (D16S539 and TH01) and the Amelogenin marker. The detection of the Y allele in samples could provide a useful tool in the triage and submission of sexual assault samples by enforcement authorities. Male template material was detected on a range of common sexual assault evidence items including cotton pillow cases, condoms, swab heads and glass surfaces and shows a detection limit of 1 in 1000 dilution of neat semen. These data indicate this technology has the potential to be a useful tool for the detection of male donor DNA in sexual assault casework.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号