首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 209 毫秒
1.
Visualization of fingerprint deposits by digital color mapping of light reflected from the surface of heated brass, copper, aluminum, and tin has been investigated using Adobe® Photoshop®. Metals were heated to a range of temperatures (T) between 50°C and 500°C in 50°C intervals with enhancement being optimal when the metals are heated to 250°C, 350°C, 50°C, and 300°C, respectively, and the hue values adjusted to 247°, 245°, 5°, and 34°, respectively. Fingerprint visualization after color mapping was not degraded by subsequent washing of the metals and color mapping did not compromise the visibility of the fingerprint for all values of T. The optimum value of T for fingerprint visibility is significantly dependent of the standard reduction potential of the metal with Kendall's Tau (τ) = 0.953 (p < 0.001). For brass, this correlation is obtained when considering the standard reduction potential of zinc rather than copper.  相似文献   

2.
This study investigated whether routinely used forensic tests can distinguish 3‐day‐old or 2‐week‐old fly artifacts, produced after feeding on human blood, semen, or saliva, from the biological fluid. Hemastix®, Hemident?, and Hemascein? were unable to distinguish blood from artifacts. Hemastix® returned false positives from negative controls. ABAcard® Hematrace® and Hexagon OBTI could distinguish blood from 3‐day‐old artifacts, but not 2‐week‐old artifacts. Phadebas® and SALIgAE® were unable to distinguish saliva from artifacts. RSID?‐Saliva was able to distinguish saliva from 3‐day‐old artifacts, but not 2‐week‐old artifacts. Semen tests Seminal Acid Phosphatase, RSID?‐Semen, and ABAcard® p30 were all able to distinguish semen from 3‐day‐old artifacts, but not 2‐week‐old artifacts. The tests investigated cannot be relied upon to distinguish artifacts from biological fluids. However, if an artifact is identified by its morphology, a positive result may indicate which biological fluid the fly consumed, and this knowledge may prove useful for investigators searching for DNA.  相似文献   

3.
A form of physical vapor deposition, called the conformal‐evaporated‐film‐by‐rotation (CEFR) method, was optimized for the conformal deposition of columnar thin films (CTFs) on sebaceous fingermarks. Relying on the surface topology of the fingermark, the CTF development technique is different from traditional development techniques. After the optimization of the development conditions, the CTF development technique was found to be superior to traditional development methods on several nonporous substrates: the smooth side of Scotch® Multitask, Gorilla®, and Scotch® Duct tapes; clear and black soft plastics; stained and sealed walnut and cherry woods; partial bloody fingermarks on stainless steel; and discharged cartridge casings. It was equally as good as other development techniques on other substrates, but worse on a few. The optimization study is expected to assist in designing a mobile CEFR apparatus capable of on‐scene development of fingermarks.  相似文献   

4.
Luminol, Bluestar®, and Hemascein® were tested to compare detection sensitivities to latent blood. Untreated, EDTA‐treated human blood, and a catalytically similar blood substitute were diluted (neat to 1:1,000,000) and pipetted onto a variety of substrates. Luminol and Bluestar® performed similarly on all surfaces and fabrics. Hemascein® yielded poor results on wood surfaces, but performed well in the detection of latent blood on fabrics. Results from untreated, EDTA‐treated, and synthetic blood results indicate that EDTA‐treated blood is similar or slightly less sensitive than untreated blood at all dilutions and on all substrates, and the synthetic blood is less sensitive than real blood, but consistent in detection threshold and thus is useful as a training aid. Additionally, some foods and household chemicals that have previously been shown to cross‐react were tested with Bluestar®, Hemascein®, and luminol. Hemascein® cross‐reacted with many substances, while both luminol reagents were more discriminating.  相似文献   

5.
In sexual assault cases DNA profiling of spermatozoa can be of critical importance. Most methods use differential extraction of the spermatozoa to separate it from the female component. Here we have compared two commercially available differential extraction methods, the QIAamp® DNA mini kit (Qiagen) and Differex™ with the DNA IQ® System (Promega). Simulated postcoital samples were prepared using buccal cells from a female donor and spermatozoa from three male donors. A dilution series ranging from neat semen to a 1:1500 dilution (semen:dH2O) was prepared and mixed with an equal volume of saliva from a female donor. Extraction efficiency was assessed using DNA concentration measured with NanoDrop 2000 and Quantifiler® Human DNA Quantification Kit and the profile count of full, partial and mixed DNA profiles generated using SGM Plus and PowerPlex® ESI 17. Statistical analysis was carried out using Randomisation in R, which is a robust model making no assumption of the distribution of data. Based on the amount of DNA extracted and the types of profiles no significant difference in the performance of the two extraction kits was seen. However, the processing time taken with the Differex™ System was about half than that of the QIAamp® DNA mini kit and involved fewer liquid transfers.  相似文献   

6.
Abstract: Forensic anthropologists routinely macerate human bone for the purposes of identity and trauma analysis, but the heat and chemical treatments used can destroy genetic evidence. As a follow‐up to a previous study on nuclear DNA recovery that used pig ribs, this study utilizes human skeletal remains treated with various bone maceration techniques for nuclear DNA amplification using the standard Combined DNA Index System (CODIS) markers. DNA was extracted from 18 samples of human lower leg bones subjected to nine chemical and heat maceration techniques. Genotyping was carried out using the AmpF?STR® COfiler® and AmpF?STR® Profiler Plus® ID kits. Results showed that heat treatments via microwave or Biz/Na2CO3 in sub‐boiling water efficiently macerate bone and produce amplifiable nuclear DNA for genetic analysis. Long‐term use of chemicals such as hydrogen peroxide is discouraged as it results in poor bone quality and has deleterious effects on DNA amplification.  相似文献   

7.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

8.
Abstract: The design and preliminary characterization of a novel sensor for drugs of abuse, DETECHIP®, is described in this proof‐of‐concept note. Combining both colorimetric and fluorimetric assays, DETECHIP® is suitable for lab and field use. More than a conventional spot test which provides a single “yes or no” answer, DETECHIP® provides twenty responses for a more complete characterization of suspect material. This is accomplished by visually noting colorimetric and fluorescent changes of carefully selected dyes upon the addition of test analytes, including drugs of abuse, with respect to controls. Color and fluorescence changes are recorded numerically so that a 20 digit identification code can be constructed for comparison of test analytes and known compounds. DETECHIP® is applicable to a variety of drugs, both plant‐derived and synthetic, addressing the need to use several different spot tests simultaneously for a single sample.  相似文献   

9.
Significant efforts are being devoted to the development of methods enabling rapid generation of short tandem repeat (STR) profiles in order to reduce turnaround times for the delivery of human identification results from biological evidence. Some of the proposed solutions are still costly and low throughput. This study describes the optimization of an analytical process enabling the generation of complete STR profiles (single‐source or mixed profiles) for human identification in approximately 5 h. This accelerated process uses currently available reagents and standard laboratory equipment. It includes a 30‐min lysis step, a 27‐min DNA extraction using the Promega Maxwell®16 System, DNA quantification in <1 h using the Qiagen Investigator® Quantiplex HYres kit, fast amplification (<26 min) of the loci included in AmpF?STR® Identifiler®, and analysis of the profiles on the 3500‐series Genetic Analyzer. This combination of fast individual steps produces high‐quality profiling results and offers a cost‐effective alternative approach to rapid DNA analysis.  相似文献   

10.
The purpose of this study was to identify and compare patterns of trauma associated with AutoPulse® CPR and manual CPR. Finalized autopsy records from 175 decedents brought to the Harris County Institute of Forensic Sciences were reviewed, 87 received manual‐only CPR, and 88 received AutoPulse® CPR (in combination with manual CPR as per standard protocol). The characteristic pattern observed in manual‐only CPR use included a high frequency of anterior rib fractures, sternal fractures, and midline chest abrasions along the sternum. The characteristic pattern observed in AutoPulse® CPR use included a high frequency of posterior rib fractures, skin abrasions located along the anterolateral chest and shoulder, vertebral fractures, and a few cases of visceral injuries including liver lacerations, splenic lacerations, and hemoperitoneum. Knowledge of the AutoPulse® CPR injury pattern can help forensic pathologists differentiate therapeutic from inflicted injuries and therefore avoid an erroneous assessment of cause and manner of death.  相似文献   

11.
Abstract: A sexual assault case resulted in a pregnancy, which was subsequently aborted. The alleged father of the fetus was unknown. Maternal and fetal types were obtained using the 11‐locus AmpF?STR® SGM Plus® kit. The national DNA database was searched for the paternal obligatory alleles and detected two suspects who could not be excluded as father of the male fetus. Additional typing using the AmpF?STR® Minifiler? kit, containing three additional autosomal loci, was not sufficient to exclude either suspect. Subsequent typing using the PowerPlex® 16, containing four additional loci, and Y‐Filer? kits resulted in excluding one suspect. Searching a database for paternal obligatory alleles can be fruitful, but is fraught with possible false positive results so that finding a match must be taken as only preliminary evidence.  相似文献   

12.
Abstract: Pyrodex ® and Triple Seven ® are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex ® contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven ® lacks sulfur but also contains 3‐nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography–mass spectrometry. Each derivative was clearly resolved from other components, and high‐quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.  相似文献   

13.
Abstract: Differentiation of 21 glitter lip‐glosses from seven manufacturers was attempted by pyrolysis gas chromatography/mass spectroscopy. Samples were pyrolyzed on a ribbon probe at 800°C for 20 sec and analyzed with an Agilent® 6890N Network GC System and Agilent® 5973 Network Mass Selective Detector with MSD Productivity ChemStation® Data Analysis software. The total ion chromatograms obtained were examined and differences in the presence or absence of certain chromatographic peaks corresponding to certain pyrolysis products (e.g., styrene, cyclohexane) noted. In cases where the total ion chromatograms between lip‐glosses were similar, select ion profiling was performed. Of the 21 lip‐glosses, 15 were differentiated by either the total ion chromatograms alone or through select ion profiling. Considering that lip‐glosses are typically worn by young women (who are disproportionately victims of sexual assault), this study offers the potential of being able to provide investigative leads in sexual assault investigations with evidentiary samples of this kind.  相似文献   

14.
Abstract: This article extends the application of 1,2,4‐triazine‐based chromogenic reagents to the detection of nonferrous metal traces left on contact with canvas and human skin. The possibility of detection of iron traces resulting from contact with objects made of stainless steel was investigated as well. Additionally, the ability of triazines to form chromatic complexes with Zn2+, Ni2+, Co2+, Cu2+, Cr3+, and Al3+ ions was studied spectrophotometrically. Molar absorption coefficients, ranging from 8.8 to 29.9 × 103/M/cm, provide high sensitivity of 1,2,4‐triazines toward nonferrous ions, thus, enabling the detection at concentrations as low as a few μM. The method was sensitive enough to detect traces resulting from a 1‐min contact with a stainless steel made object, which is commonly considered as a corrosion‐resistant material. The amounts of metal ions transferred to the skin after a 2‐min contact with objects made of brass, zinc, and copper were sufficient to develop chromatic imprints.  相似文献   

15.
Abstract: Analysis of length polymorphism at short tandem repeat (STR) loci utilizing multiplex polymerase chain reaction (PCR) remains the primary method for genotyping forensic samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit is an improved version of the AmpF?STR® Identifiler® PCR Amplification Kit and amplifies the core CODIS loci: D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, CSF1PO, FGA, TH01, TPOX, and vWA. Additional loci amplified in the multiplex reaction are the sex‐determinant, amelogenin, and two internationally accepted loci, D2S1338 and D19S433. While the primer sequences and dye configurations were unchanged, the AmpF?STR® Identifiler® Plus PCR Amplification Kit features an enhanced buffer formulation and an optimized PCR cycling protocol that increases sensitivity, provides better tolerance to PCR inhibitors, and improves performance on mixture samples. The AmpF?STR® Identifiler® Plus PCR Amplification Kit has been validated according to the FBI/National Standards and Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The validation results support the use of the AmpF?STR® Identifiler® Plus PCR Amplification Kit for human identity and parentage testing.  相似文献   

16.
Psilocybe cubensis, or “magic mushroom,” is the most common species of fungus with psychedelic characteristics. Two primer sets were designed to target Psilocybe DNA using web‐based software and NBCI gene sequences. DNA was extracted from eighteen samples, including twelve mushroom species, using the Qiagen DNeasy® Plant Mini Kit. The DNA was amplified by the polymerase chain reaction (PCR) using the primers and a master mix containing either a SYBR® Green I, Radiant? Green, or LCGreen Plus® intercalating dye; amplicon size was determined using agarose gel electrophoresis. The PCR assays were tested for amplifiability, specificity, reproducibility, robustness, sensitivity, and multiplexing with primers that target marijuana. The observed high resolution melt (HRM) temperatures for primer sets 1 and 7 were 78.85 ± 0.31°C and 73.22 ± 0.61°C, respectively, using SYBR® Green I dye and 81.67 ± 0.06°C and 76.04 ± 0.11°C, respectively, using Radiant? Green dye.  相似文献   

17.
The use of narrow‐banded visible light sources in improving the visibility of injuries has been hardly investigated, and studies examining the extent of this improvement are lacking. In this study, narrow‐banded beams of light within the visible light spectrum were used to explore their ability in improving the visibility of external injuries. The beams of light were induced by four crime‐lites® providing narrow‐banded beams of light between 400 and 550 nm. The visibility of the injuries was assessed through specific long‐pass filters supplied with the set of crime‐lites®. Forty‐three percent of the examined injuries improved in visibility by using the narrow‐banded visible light. In addition, injuries were visualized that were not visible or just barely visible to the naked eye. The improvements in visibility were particularly marked with the use of crime‐lites® “violet” and “blue” covering the spectrum between 400–430 and 430–470 nm. The simple noninvasive method showed a great potential contribution in injury examination.  相似文献   

18.
The purpose of this study was to determine the factors affecting the accuracy of 3D models and 3D prints of cranial blunt force trauma, to evaluate the applicability and limitations of modeling such injuries. Three types of cranial blunt force lesions were documented (hinge, depressed, and comminuted) using three forms of surface scanning (laser, structured light scanner, and photogrammetry) at two different quality settings (standard and high). 3D printed models of the lesions were produced using two different materials (a gypsum‐like composite powder called VisiJet® PXL and an acrylic engineered composite plastic called VisiJet® M3 in crystal colour). The results of these analyzes indicate the prints in this study exhibit some statistically significant differences from the actual bone lesions, but details of the lesions can be reproduced to within 2 mm accuracy.  相似文献   

19.
Forensic evidence samples are routinely found as stains on various substrates, which may contain substances known to inhibit polymerase chain reaction (PCR). The goal of this study was to evaluate post‐Chelex®100 purification using powdered activated carbon (PAC). Mock crime scene DNA extracts were analyzed using quantitative PCR and short tandem repeat (STR) profiling to test the DNA recovery and inhibitor removal using PAC with those of the Amicon®Ultra 100K. For extracted bloodstains on soil and wood substrates, PAC and Amicon®Ultra 100K generated similar DNA yield and quality. Moreover, the two methods significantly decreased the concentration of humic substances and tannins compared to nonpurified extracts (< 0.001). In instances where extracts contained indigo dye (bloodstains on denim), Amicon®Ultra 100K performed better than PAC due to improved amplifiability. Efficient adsorption of humic substances and tannins, which are common inhibitors, indicates PAC's potential application in the purification of high‐template DNA extracts.  相似文献   

20.
Qiagen's Investigator? Quantiplex kit, a total human DNA quantitation kit, has a 200‐base pair internal control, fast cycling time, and scorpion molecules containing a covalently linked primer, probe, fluorophore, and quencher. The Investigator? Quantiplex kit was evaluated to investigate a value under which complete short tandem repeat (STR) failure was consistently obtained. Buccal swabs were extracted using the Qiagen QIAamp® DNA Blood Mini Kit, quantified with the Investigator? Quantiplex kit using a tested half‐volume reaction, amplified with the ABI AmpFlSTR® Identifiler kit, separated on the 3100Avant Genetic Analyzer, and data analyzed with GeneMapper® ID v.3.2. While undetected samples were unlikely to produce sufficient data for statistical calculations or CODIS upload (2.00 alleles and 0.82 complete loci on average), data may be useful for exclusionary purposes. Thus, the Investigator? Quantiplex kit may be useful for predicting STR success. These findings are comparable with previously reported data from the Quantifiler? Human kit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号