首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
The use of 2,2'-azino-di-[3-ethylbenzthiazolinesulfonate(6)] diammonium salt (ABTS) for the enhancement of fingerprints in blood has been investigated. Optimal pH conditions and H2O2 concentrations have been determined using UV/Vis spectroscopy. ABTS is an effective and safe noncarcinogenic (though more expensive) alternative to the presently used 3,3'-diaminobenzidine (DAB) for the development of blood fingerprints, especially on porous surfaces. The bright green color of the oxidized ABTS is an advantage on certain colored surfaces where the dark brown color of DAB does not stand out well from the background. Development with ABTS does not interfere with subsequent DAB treatment, making ABTS a "nothing-to-lose" reagent. ABTS can be used after ninhydrin treatment, but the reverse is not the case.  相似文献   

2.
A rapid colorimetric method for detection of p‐phenylenediamine (PPD) in various biological samples is developed. The o‐cresol test for acetaminophen detection has been modified to detect PPD in blood, urine, gastric contents, and liver. After precipitating protein with trichloroacetic acid solution (2 mL, 10% w/v), biological specimens were required to convert PPD metabolites to PPD by acid hydrolysis. Finally, o‐cresol solution (1 mL, 1% w/v), hydrogen peroxide (200 μL, 3%v/v), and concentrated ammonium hydroxide (0.5 mL) were added in the biological samples. The presence of PPD was indicated by formation of violet color which was turned to bluish green color within 10–15 min. The limit of detection was found to be 2 mg/L in blood, urine, and gastric contents and 2 mg/Kg in liver. This method is also free from any potential interference by p‐aminophenol, acetaminophen, and other amine drugs under test conditions. This method was successfully employed to thirteen fatal cases of PPD poisoning.  相似文献   

3.
Laser detection of latent fingerprints on a white paper has been performed, previously. Ultraviolet fluorescence from various kinds of printer toner and ink used for home printers were measured to study fluorescence imaging of fingerprints on a color-printed white paper. The experimental system consisted of a nanosecond pulsed tunable laser and a cooled CCD camera. Excitation wavelengths are 230 and 280 nm. Fourteen printers consisting of three color laser printers, three color inkjet printers, five monochrome laser printers, two monochrome copy machines, and a color copy machine were tested. Toner and ink of most printers exhibited fluorescence in the region from 360 to 550 nm. In most cases, clear fluorescence images were obtained by time-resolved imaging with a band-pass filter and 280-nm excitation. However for toners from laser color printers that showed strong fluorescence, better results were obtained with 230-nm excitation. Latent fingerprints on a photograph page and a black-character page of a newspaper were also imaged.  相似文献   

4.
本文介绍了一种双重免疫酶标染色方法(单酶法)。其原理是过氧化也物酶遇DAB-CoCl2-H2O2显蓝黑色,遇DAB-H2O2显棕黄色,两种颜色对比鲜明。将此法应用于检测法医尸检材料心和脑中的有关抗原,效果良好。该法灵敏、简便、经济,且切片可长期保存,困而有一定的实用价值。  相似文献   

5.
Apparatus to produce a spatially and temporally uniform heat source is described and this is used to visualize latent fingerprints deposited onto thermal paper by raising the temperature of the paper. Results show an improvement over previous research when fingerprint deposits are aged or the developed fingerprints faint; visualization being enhanced by the use of a blue LED light source of 465 nm peak wavelength. An investigation of the components in fingerprint sweat likely to affect the solubility and hence color change of the dye present in the thermal paper has shown that polar protic solvents able to donate a proton are favored and a polar amino acid found commonly in eccrine fingerprint sweat (lysine) has been shown able to produce the desired color change. Aged fingerprint deposits on thermal paper from a variety of sources up to 4 years old have been visualized with this technique.  相似文献   

6.
Literature defining ‘police legitimacy’ lacks qualitative research on those populations most often targeted by law enforcement agencies, including people of color in urban areas. This same literature defines police legitimacy as something unquestionable and automatic. Exploration of this concept is limited to strategies to increase public ‘trust’ in police, and public compliance to their authority. We address these limitations in the available scholarship through an analysis of interviews with a diverse sample of Oakland (CA) residents on their experiences with the Oakland Police Department (OPD). Their narratives are presented in the historical context of controversy, budget problems, federal investigations, and racialized violence that help to define the relationship between OPD and Oakland communities. Those interviewed, universally observed OPD’s failure to address the most common crime problems in the city, while others, particularly people of color, found them to be a personal or public threat to safety. Their narratives fly in the face of the manifest functions of municipal police forces, are fully supported by the contemporary empirical history of the OPD, and suggest the illegitimate authority – including the monopoly on the use of force – of organizations like OPD in a democratic society.  相似文献   

7.
应用斑点ELISA快速进行体液(斑)的血型测定   总被引:2,自引:2,他引:0  
<正> 在法医学上体液(斑)的血型测定一般常规应用中和试验、吸收试验、解离试验及混合凝集反应。这些试验既耗时,又需较高的技术,且要新鲜标准红细胞指示结果。本实验系应用我们自己提纯标酶的抗-A,-B与抗-H单克隆抗体A,利用斑点ELISA来进行体液(斑)的血型测定。通过颜色变化直接判断血型。  相似文献   

8.
目的根据胶带粘面上潜在手印的特点,利用染料和潜手印的理化性质,研究开发胶带粘面手印荧光显现剂。方法在各种胶带粘面上显现潜在手印,并与常规的碳素墨水染色法进行比较。结果在长波紫外线照射下手印呈黄色明亮荧光,手印纹线清晰、连贯,基本不受手印遗留时间、客体表面颜色和性质的影响。结论胶带粘面上的汗潜手印和血潜手印用荧光显现剂显现效果优于碳素墨水染色法,在实际案件的侦破中有较好的应用前景。  相似文献   

9.
Latent fingerprint deposits on thermal paper sourced from the U.S., China, the U.K., and Australia have been visualized by heating. U.S. and Chinese sourced paper produced two distinct types of fingerprint development. In one type (type 1), the paper dye colors where the deposit is present (as previously reported) and in the other type (type 2) the ‘inverse’ of this gives paper coloring only in areas not coincident with the deposit. Both development types gave identifiable fingerprints, the majority fading within 24 h of heating. Fingerprint development from U.K. and Australian sourced paper was exclusively type 1 and resistant to fading. Temperatures for fingerprint visualization were higher for U.S. paper (64–71°C) and Chinese paper (75–95°C) than for U.K. and Australian sourced paper (43–50°C). Particularly for Chinese sourced paper, these temperatures were within a few degrees of the normal paper color temperature. A mechanism for type 2 fingerprint development is proposed.  相似文献   

10.
Color separation is an image processing technique that has often been used in forensic applications to differentiate among variant colors and to remove unwanted image interference. This process can reveal important information such as covered text or fingerprints in forensic investigation procedures. However, several limitations prevent users from selecting the appropriate parameters pertaining to the desired and undesired colors. This study proposes the hybridization of an interactive differential evolution (IDE) and a color separation technique that no longer requires users to guess required control parameters. The IDE algorithm optimizes these parameters in an interactive manner by utilizing human visual judgment to uncover desired objects. A comprehensive experimental verification has been conducted on various sample test images, including heavily obscured texts, texts with subtle color variations, and fingerprint smudges. The advantage of IDE is apparent as it effectively optimizes the color separation parameters at a level indiscernible to the naked eyes.  相似文献   

11.
This study was aimed at determining the effect of seven blood enhancement reagents on the subsequent Profiler Plus fluorescent STR DNA analysis of fresh or aged bloody fingerprints deposited on various porous and nonporous surfaces. Amido Black, Crowle's Double Stain. 1,8-diazafluoren-9-one (DFO), Hungarian Red, leucomalachite green, luminol and ninhydrin were tested on linoleum, glass, metal, wood (pine, painted white), clothing (85% polyester/15% cotton, 65% polyester/35% cotton, and blue denim) and paper (Scott 2-ply and Xerox-grade). Preliminary experiments were designed to determine the optimal blood dilutions to use to ensure a DNA typing result following chemical enhancement. A 1:200 blood dilution deposited on linoleum and enhanced with Crowle's Double Stain generated enough DNA for one to two rounds of Profiler Plus PCR amplification. A comparative study of the DNA yields before and after treatment indicated that the quantity of DNA recovered from bloody fingerprints following enhancement was reduced by a factor of 2 to 12. Such a reduction in the DNA yields could potentially compromise DNA typing analysis in the case of small stains. The blood enhancement chemicals selected were also evaluated for their capability to reveal bloodmarks on the various porous and nonporous surfaces chosen in this study. Luminol. Amido Black and Crowle's Double Stain showed the highest sensitivity of all seven chemicals tested and revealed highly diluted (1:200) bloody fingerprints. Both luminol and Amido Black produced excellent results on both porous and nonporous surfaces, but Crowle's Double Stain failed to produce any results on porous substrates. Hungarian Red, DFO, leucomalachite green and ninhydrin showed lower sensitivities. Enhancement of bloodmarks using any of the chemicals selected, and short-term exposure to these same chemicals (i.e., less than 54 days), had no adverse effects on the PCR amplification of the nine STR systems surveyed (D3S 1358, HumvWA, HumFGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820) or of the gender determination marker Amelogenin. The intensity of the fluorescent signals was very similar and the allele size measurements remained constant and identical to those of untreated bloody fingerprints. No additional background fluorescence was noted. Continuous exposure (for 54 days) to two of the seven enhancement chemicals selected (i.e., Crowle's Double Stain and Hungarian Red) slightly reduced the amplification efficiency of the longer STR loci in profiles of fresh and 7 to 14-day-old bloodprints. This suggests that long-term exposure to these chemicals possibly affects the integrity of the DNA molecules. This study indicates that significant evidence can be obtained from fresh or aged bloody fingerprints applied to a variety of absorbent and nonabsorbent surfaces which are exposed to different enhancement chemicals for short or long periods of time. It also reaffirms that PCR STR DNA typing procedures are robust and provide excellent results when used in concert with fluorescence-based detection assays after fingerprint identification has taken place.  相似文献   

12.
High dynamic range (HDR) imaging is a function that combines five images with different exposures into a single image. This technique may provide fine ridge details of fingerprint images for forensic latent fingerprint examination. Therefore, viewing fingerprints under optimal conditions is of paramount importance. This paper analyzes HDR and non‐HDR photos by using the Michelson contrast formula. The Michelson formula will provide a measurement to determine whether better contrast between the background and print can be achieved using the HDR function and if the background color affects the quality of the images. Two hypothesis were tested: (i) the HDR image provides more details of fingerprints with a better tone, greater clarity, and contrast than a normally exposed image regardless of the background color; (ii) the background color does not affect the quality of HDR fingerprint images overall, but the multi‐color background may increase the contrast of HDR fingerprint images in some cases.  相似文献   

13.
The design of chemical compounds for development of latent fingerprints is explored computationally. Our main findings are: (a) We show why past attempts to improve the widely used ninhydrin gave relatively small improvements (referring to color only). The optical transition is connected with a "transition core" and therefore is influenced little by substitution on the aromatic rings. (b) We propose new analogues of ninhydrin with a significant potential such as thiono derivatives.  相似文献   

14.
目的建立巯基丁二酸修饰的水溶性碲化镉量子点溶液(MSA/CdTe QDs)显现多种客体表面的血潜指纹的方法。方法利用量子点对人体血液成分的特异性标识作用,365nm紫外光激发使其荧光显像。结果 MSA/CdTe溶液显现时间显著短于文献报导的同类方法;显现效果和灵敏度优于显现血潜指纹常用试剂四甲基联苯胺和氨基黑10B。结论水溶性MSA/CdTe溶液适于显现多种客体表面的血潜指纹,效果优异。  相似文献   

15.
Abstract: This study develops new histomorphological algorithms for Maya populations’ human ribs and tests the applicability of published algorithms. Thin sections from the fourth rib of 36 individuals of known age were analyzed under polarized light microscopy. Osteon population density (OPD, the concentration of intact and fragmented osteons per mm2), cortical area (CA), and osteon size (OS) were recorded. Seven algorithms were calculated, using all combinations of variables, and compared to the performance of published formulas. The OPD‐based formulas deviate from the known age 8.7 years on average, while those from OS and CA deviate between 10.7 and 12.8 years. In comparison, our OPD‐based algorithms perform better than the one by Stout and Paine and much better than Cho et al. In conclusion, algorithms should be developed using OPD for different ethnic groups; although Stout and Paine’s can be used for Maya and maybe Mesoamerican individuals.  相似文献   

16.
The purpose of this research is to assess the vulnerabilities of a high resolution fingerprint sensor when confronted with fake fingerprints. The study has not been focused on the decision outcome of the biometric device, but essentially on the scores obtained following the comparison between a query (genuine or fake) and a template using an AFIS system. To do this, fake fingerprints of 12 subjects have been produced with and without their cooperation. These fake fingerprints have been used alongside with real fingers. The study led to three major observations: First, genuine fingerprints produced scores higher than fake fingers (translating a closer proximity) and this tendency is observed considering each subject separately. Second, scores are however not sufficient as a single measure to differentiate these samples (fake from genuine) given the variation due to the donors themselves. That explains why fingerprint readers without vitality detection can be fooled. Third, production methods and subjects greatly influence the scores obtained for fake fingerprints.  相似文献   

17.
Latent fingerprint deposits on thermal paper have been visualized noninvasively at visible wavelengths when illuminated with a UV‐A light source (peak 365 nm). A higher intensity UV source (250 W/m2 at 0.38 m) gave superior fingerprint visibility when compared with a 60 W/m2 (at 0.4 m) source. Removing the visible (blue) component of the light source emission did not adversely affect the visibility of the fingerprint. Sample fingerprints from 100 donors, when examined 24 h after deposition, produced identifiable fingerprints from nearly 34% of fingerprint deposits. A mechanism for the observed visibility is proposed based on low emission of visible wavelengths from areas of thermal paper coincident with the fingerprint deposit, when illuminated with UV. This is likely due to a weak color change in the thermal paper dye arising from protonated amino acid components of the sweat. This effect was not observed on nonthermal paper.  相似文献   

18.
The purpose of this research is to determine if latent fingerprints deposited on the exterior glass surfaces of vehicles, then covered in debris, can be recovered. Past research used liquid latex to lift soot to recover trace evidence. Recently, liquid latex has been used to recover latent fingerprints along the bottom of vehicles. In this study, a total of 216 latent fingerprints were deposited on the exterior windows of three vehicles. Three control and three experimental latent fingerprints were placed on each side window. The vehicles collected debris for either 2, 3, or 4 weeks. After debris collection, liquid latex was applied to the experimental sections. The underlying fingerprints were developed with white granular powder. Control fingerprints were developed directly with white granular powder. A chi-square test revealed a significant difference in fingerprint recovery between the control and liquid latex method (X2 = 9.026, d.f. = 1, p = 0.003). An odds ratio determined that the control method increases the probability of latent fingerprint recovery by 2.68. Fisher's exact test indicated that there is no statistically significant difference between the detail of the recovered control and experimental fingerprints (p = 0.065). This study demonstrates that recovery of fingerprints is possible using the liquid latex method; however, the control method recovers more fingerprints on the glass exterior of vehicles. If latent fingerprints are thought to be present on the exterior glass surfaces of vehicles, the control method should be used to improve vehicle processing by investigators.  相似文献   

19.
目的研究油红O显现手印配方中各物质的作用及其对显现效果的影响。方法对配方中的主要成分进行定性、定量实验来分析、考察实验结果。结果油红O粉末的颜色与显出的手印纹线颜色关系较大,溶液中的氢氧化钠关系着显出的手印纹线与背景的反差。结论 Alexandre Beaudoin公布的配方稳定、显现效果好,值得在实践工作中推广。  相似文献   

20.
目的 探究高仿真制模伪造指印的识别方法.方法 选取多个印泥指印作为母版,分别采用曝光法制作指模,将母版指印与对应的伪造指印进行整体比较及显微比较.结果 伪造指印较母版指印尺寸存在差异、纹线略变粗、纹线间隔略变小、细节特征易黏连、细小痕迹及细微特征不反映或反映不全、单根纹线的墨迹分布平实且缺少细微漏白等.结论 识别伪造指...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号