首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Due to the suspicion of a gynaecologist, a pathologist was suspected of incorrect diagnoses in cases of breast cancer and the interchanging of tissue samples. Many women applied to the attorney's bureau to clarify the reproaches. The privately owned laboratory for pathology was searched and 926 histological slides, roughly the same number of paraffin blocks and about 20 formalin fixed tissue samples were confiscated. Together with other confiscated material, at least 1236 histological slides and additional 249 paraffin blocks had to be sorted. Histological slides and paraffin blocks were matched with patients as far as possible following the laboratory book. Many of the warranted samples which were diagnosed as containing the carcinoma by the pathologist were missing. A total of 160 samples were chosen and rediagnosed by two independent pathologists. The formalin fixed tissue was negative for DNA most likely due to storage in formalin for years. Most of the histological slides were positive for DNA. On the whole, 18 expertises about histological findings and the DNA results were given. In some cases only DNA results could be presented, as previous experts had only performed DNA examinations without controlling the histological diagnosis. In six cases a carcinoma could be confirmed and the DNA profile matched with patient's DNA; in seven cases a carcinoma was confirmed without match with the patient; in two cases the carcinoma could not be confirmed in the presented samples. A jurisdictional solution was impossible because the accused pathologist died during the investigation. In conclusion, it must be stated that a DNA examination of histological slides should never be performed without a rediagnosis of an independent pathologist and photographic documentation of the findings. Whenever possible, material should be left on the slide.  相似文献   

2.
Abstract: Archived slides of cell smears treated with histological stains for sperm detection are often the only source of DNA available when cold cases are reopened. There have been conflicting reports as to the negative effects of particular histological stains on DNA recovery and quality from human cells, making stain selection an important consideration for forensic laboratories. This study investigates the effect of several staining systems on DNA recovery from histological slide samples stored from 0 to 10 weeks. DNA profiles obtained after analysis of these samples with AmpFlSTR® Identifiler? and increased cycle AmpFlSTR® SGM Plus? short tandem repeat (STR) profiling systems and the effects that these stains have on DNA quantity and quality over time are described. Results indicate that Christmas Tree and Hematoxylin and Eosin stains do not have significantly different effects on DNA quality after 10‐week storage of slides. This research will assist scientists to select staining systems that have minimal deleterious effects on the DNA recovered.  相似文献   

3.
New multiplex PCR sets of commonly used short tandem repeat (STR) markers have been developed to produce PCR products that are reduced in size when compared to standard commercial STR kits. The reduction in size of these amplicons can facilitate the examination and analysis of degraded DNA evidence by improving amplification efficiency. This "miniSTR" approach will permit current forensic practitioners to use STR markers and instrumentation already present in their laboratories and to generate genotyping data that is directly comparable to reference samples and searchable through the FBI's Combined DNA Index System (CODIS) databases. This paper discusses the development of these new primer sets and presents some initial results in the analysis of degraded and aged DNA samples. A method for removal of problematic fluorescent dye artifacts is also described. Comparison studies in over 100 samples have verified that these miniSTR primers can provide fully concordant results to commercial STR kits and can provide improved signal from degraded DNA specimens. These miniplex sets should prove valuable in the analysis of samples where allele dropout and reduced sensitivity of larger STR alleles occurs.  相似文献   

4.
《Science & justice》2023,63(5):588-597
Titanium dioxide (titania, TiO2) is frequently used as a coating for a variety of self-cleaning products, such as antifogging vehicle mirrors, ceramic tiles, and glass windows because of its distinct physiochemical features. When exposed to light TiO2 causes photocatalytic decomposition of organic contaminants, potentially compromising DNA integrity. The impact of TiO2-coated commercial glasses, Bioclean® and SaniTise™, on trace DNA persistence, recovery, and profiling was investigated. DNA in saliva and touch samples deposited on self-cleaning glass slides exposed to indoor fluorescent light for up to seven days was more degraded than control samples indicating some degree of fluorescent light-induced photocatalytic activity of the self-cleaning surfaces. When exposed to sunlight, DNA yields from saliva and touch samples deposited on the titania-coated substrates decreased rapidly, with a corresponding increase in DNA degradation. After three days no DNA samples applied to self-cleaning glass and exposed to natural sunlight yielded STR profiles. These results suggest that the photocatalytic activation of TiO2 is the likely mechanism of action underlying the extreme DNA degradation on the Bioclean® and SaniTise™ glasses. Consequently, rapid sample collection and use may be warranted in casework scenarios involving TiO2-coated materials.  相似文献   

5.
The PE‐Swab direct STR amplification workflow was developed to process low‐level “touch DNA” samples. In this workflow, a forensic sample is first collected on a 4‐mm PE‐Swab (a novel sample collection device); two 2‐mm punches containing collected samples are then generated from the PE‐Swab and directly amplified for STR typing. Compared to the conventional STR workflow, which involves DNA extraction, purification, and elution volume reduction, the PE‐Swab direct STR amplification workflow does not require sample preparation and takes <60 sec before a touch sample is ready for STR amplification. Because there is no DNA loss due to sample preparation, the PE‐Swab workflow is more sensitive than the conventional STR workflow. The average peak height per sample obtained by the PE‐swab workflow is 3 times higher than that from the conventional workflow with both low‐level single source and two‐contributor mixture samples tested in this study.  相似文献   

6.
When fresh blood is not available as a control in stain investigations extracted teeth, hair, preserved tissue samples, histological slides, cigarette butts or used stamps can also be used. This paper reports on a stain investigation performed 7 months after the death of the victim, where a bedside card from the medical records was successfully employed as a control blood sample. In a series of 10 bedside cards up to 9 years old, the investigation with the PCR method showed recognizable patterns in the STR systems SE 33 and TC 11. Matching patterns could be found from the 4 sections of each card (anti A, anti B, anti AB and anti D). A comparison of the oldest card with a fresh blood sample of the patient also showed matching patterns. AMPFLPs were successful with more recent cards. Using the PCR method typing of bedside cards from medical records up to 10 years old can be used in stain investigations.  相似文献   

7.
目的建立一套显微细胞捕获技术用于法医学生物检材DNA检验方法。方法使用VeritasTM LCM激光捕获仪,采用紫外加红外的捕获方式,对框架覆膜玻片上经苏木素染色口腔上皮细胞进行捕获,采用改良硅珠法提取细胞DNA,使用Identifiler TM试剂盒在5μL体系中进行PCR扩增。结果成功获得20个口腔上皮细胞的13个以上完整STR基因座分型谱带。结论本研究建立的方法适合法医学生物检材制成的染色涂片上细胞的DNA检验。  相似文献   

8.
不同分型方法的STR分型差异   总被引:2,自引:1,他引:1  
目的调查不同的STR分型系统之间分型的一致性。方法 10 0例不同个体的DNA样本分别用单位点聚丙烯酰胺凝胶银染法和PowerPlex16System试剂盒对 13个法医学常用STR位点进行基因分型 ,并比较两种不同分型系统间的分型结果。结果 1例样本在D8S1179位点出现了分型不一致的结果 :银染法的基因型为 12 / 14 ,而用PowerPlex16System试剂盒的分型则为 12 / 15。结论不同的STR分型系统可导致不同的基因分型  相似文献   

9.
当前,DNA检验技术作为打击犯罪的利器,在法医鉴定中发挥着巨大作用。但对于性侵、暴力犯罪等案件中提取的混合DNA样本,尤其是从受害人或嫌疑人的接触物上采集的高度不平衡混合DNA样本,利用常染色体STR检验方法得到的结果通常不是很理想。由于PCR扩增偏倚,从混合样本中检测出痕量DNA分型是一个巨大的挑战,也是当前法医DNA检验的一个难点。近年来的研究显示,利用新型连锁遗传标记DIP-STR,即结合缺失或插入多态性片段DIP(deletion–insertion polymorphisms)和STR的连锁位点,可以用来检测出混合DNA样本中任一性别和细胞起源的微量DNA,甚至在DNA混合比例高达1:1000时,DIP-STR标记的灵敏度、特异性仍旧相对较为理想。因此,DIP-STR标记的分析可以作为常染色体STR检验的有效补充。本文将对DIP-STR在不平衡混合DNA样本分析中的研究背景、方法及其应用前景进行综述。  相似文献   

10.
A new set of multiplexed PCR primers has been applied to the analysis of human skeletal remains to determine their efficacy in analyzing degraded DNA. These primer sets, known as Miniplexes, produce shorter amplicons (50-280 base pairs (bp)) than standard short tandem repeat (STR) kits, but still utilize the 13 CODIS STR loci, providing results that are searchable on national DNA databases. In this study, a set of 31 different human remains were exposed to a variety of environmental conditions, extracted, and amplified with commercial and Miniplex DNA typing kits. The amplification efficiency of the Miniplex sets was then compared with the Promega PowerPlex 16 system. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only 16% of the samples generated full profiles with the Powerplex 16 kit. Complete profiles were obtained for 11 of the 12 Miniplex loci with amplicon sizes less than 200 bp. These data suggest smaller PCR amplicons may provide a useful alternative to mitochondrial DNA for anthropological and forensic analysis of degraded DNA from human skeletal remains.  相似文献   

11.
显微操作法提取混合斑中精子细胞方法的探讨   总被引:10,自引:5,他引:5  
目的尝试建立一种提取混合斑中精子细胞的检测方法。方法在人为控制条件下,制备精液—阴道液混合斑,分别使用显微操作法与差异裂解法分离精子细胞,提取DNA,进行STR基因型检测。结果采用显微操作法检测成功率11/12,差异裂解法成功率1/12,两者有显著性差异。结论显微操作法可有效获取精子细胞,排除女性物质和其它杂质的干扰,STR分型成功率优于差异裂解法。  相似文献   

12.
目的将压力循环技术(PCT)用于指甲DNA提取,并对方法学进行评价。方法收集10份人指甲样本,剪碎约为1mm×1mm大小,采用10%漂白粉水,10%SDS,10%漂白粉水,无菌水清洗样本。10份样本各分成两组,1组用压力循环技术处理,另1组不作处理,提取DNA经复合扩增并进行STR分型检测,用于评价压力循环技术的作用。取5份指甲样本用血浸泡,5份用去离子水浸泡,之后采用上述清洗方法各清洗1-3次,收集各次清洗用的无菌水提取DNA,经STR分型检测,用于评价清洗对去除外源性DNA的效果。结果 10份经压力循环技术处理的样本中有7例比相应未经处理样本DNA提取量更高,但两组进行统计学处理,差异不具有统计学意义(P〉0.05);两组样本中提取DNA含量在0.026 ng以上的样本均得到完整的STR分型,与相应口腔拭子样本对照准确无误。血污染和非血污染样本清洗二次以上,均可避免外源性DNA的污染。结论使用压力循环技术并配合本文清洗方法,可有效提高人指甲DNA的提取效率,并避免外源性生物DNA的干扰,保证DNA分型结果的准确。  相似文献   

13.
目的探讨强奸致孕案葡萄胎组织的DNA检验和STR结果分析。方法用DNA Typer TM15试剂盒对犯罪嫌疑人、受害人血样和流产胚胎组织进行荧光复合STR基因座扩增检测。结果检测的一例流产胚胎组织DNA的STR峰谱表现出部分3条带,且3条带中有两个等位基因来源于犯罪嫌疑人,另外一个来源于受害人,推断为单卵双精子受精的部分性葡萄胎。结论应用STR分型技术可以推断葡萄胎的DNA来源和受精类型,为亲缘关系鉴定提供依据。  相似文献   

14.
FTA Cards (GE Healthcare) have been used for more than 4 years in Denmark for the collection of buccal cells as reference samples in crime cases. Semi-automated protocols for STR typing of DNA on punches of FTA Cards are routinely used. In average, full STR profiles were generated from approximately 95% of the FTA Cards with a standard punching protocol, while partial or no STR profile were obtained from 5% of the samples. Here, the Qiagen BioRobot® EZ1 Workstation (Qiagen) and the EZ1 DNA Investigator Kit (Qiagen) was used to extract DNA from 29 FTA Cards from which a complete STR profile was not generated with the standard punching protocol. All 29 samples were successfully typed with the AmpF?STR® Identifiler™ PCR Amplification Kit (Applied Biosystems) and with the SNPforID 49plex SNP assay. The lowest amount of DNA that resulted in complete STR and SNP profiles was 80 pg. The STR and SNP profiles were identical to those generated from another sample collected from each of the 29 individuals.  相似文献   

15.
Disputes over the identity of a urine sample donor have been reported, and urine authentication by genetic profiling has helped resolved the cases. However, since genotyping of urine is not always required, many drug-testing laboratories may face sample storage issues. Several studies have investigated the use of FTA® cards as a convenient tool for keeping specimen at room temperature for extended periods of time. However, generating complete STR profile from some FTA®-deposited urine samples remains challenging due to low levels of genetic material content, necessitating amendments to the laboratory’s standard protocols. This work therefore aims to evaluate the effects of two DNA template preparation methods, both employing FTA® cards as the storage medium, on the success rates of STR profiling from urine. Specimen from a female volunteer, representing a particularly low-yield sample, was employed. Aliquots of 1 and 2 mL were used as the starting material to evaluate DNA template preparation using the FTA® manufacturer’s protocol for disc purification against elution of DNA from the FTA® using Prepfiler™ Forensic DNA Extraction Kit. AmpFSTR™ Identifiler™ Plus PCR Amplification Kit was used to amplify the STR markers, and the PCR products were analysed using Applied Biosystems™ 3500xL Genetic Analyzer. The DNA profile qualities were examined in terms of number of loci detected and peak height balance. Comparisons with the profiles obtained from DNA isolated using QIAamp® DNA Micro Kit from 1 and 2 mL of the same batch of urine were also made. The optimised protocol was then tested on urine samples from three male volunteers. The results showed that the purification of FTA® punches according to the manufacturer’s protocol enabled full DNA profiles to be obtained from both 1 and 2 mL of urine from all samples tested, including male samples. In contrast, no DNA profile could be generated from the DNA eluted with the Prepfiler™ kit. When compared with the more conventional solid-phase DNA extraction method, the profiles generated from the FTA® punches exhibited similar reproducibility and quality to those from the template isolated by the QIAamp® Kit. This work further demonstrated the feasibility of FTA® cards as a tool for specimen storage and DNA template preparation from small volumes of urine for authentication by STR profiling. Full STR profiles could be generated from sample from both sexes without modification of the PCR conditions or injection time.  相似文献   

16.
An automatic and rapid DNA typing system was employed for personal identification, using fragmentary tissue samples from victims in an airplane accident. Two victims were crushed into small pieces, and 33 samples suspected to belong to them were recovered from under the sea. From each sample, 10 mg was used for testing. The parents' bloods of two presumptive victims were also examined. DNA extraction from samples was performed by the NaI method, and the obtained DNA samples were analyzed with the ABI PRISM system. Among 33 samples, 31 samples were identified to be human tissues, possibly from two victims. The other two samples seemed to be parts of marine animals. ABO blood group, STR polymorphism, and mitochondrial DNA polymorphism typing were possible in every examined human sample. Two victims' fragmentary tissues were identified by determining ABO genotype, STR type and mitochondrial DNA type. The system we employed enabled an accurate typing of many fragmentary samples in a short time, thus contributing to the fast and secure identification of many victims in such cases as big air accidents.  相似文献   

17.
A 96-channel microfabricated capillary array electrophoresis (muCAE) device was evaluated for forensic short tandem repeat (STR) typing using PowerPlex 16 and AmpFlSTR Profiler Plus multiplex PCR systems. The high-throughput muCAE system produced high-speed <30-min parallel sample separations with single-base resolution. Forty-eight previously analyzed single-source samples were accurately typed, as confirmed on an ABI Prism 310 and/or the Hitachi FMBIO II. Minor alleles in 3:1 mixture samples containing female and male DNA were reliably typed as well. The instrument produced full profiles from sample DNA down to 0.17 ng, a threshold similar to that found for the ABI 310. Seventeen nonprobative samples from various evidentiary biological stains were also correctly typed. The successful application of the muCAE device to actual forensic STR typing samples is a significant step toward the development of a completely integrated STR analysis microdevice.  相似文献   

18.
Deng JQ  Li YB  Wu J  Hou YP 《法医学杂志》2006,22(1):39-42
目的探索建立体外STR滑脱模型,研究STR滑脱产生的影响因素,探讨STR的发生机制。方法首先通过全基因组扩增技术—简并寡核苷酸引物PCR(Degenerateoligonucleotide-primedPCR,DOP)对模板DNA样本进行扩增放大,然后以其产物作为后续STR分析的模板,对以上实验过程中的一系列实验条件进行控制,观察滑脱现象的产生情况。结果初步建立了STR的滑脱模型,观察到了STR滑脱现象的发生。结论STR的发生是一系列综合因素作用的结果,DNA模板用量、MgCl2的浓度、DNA聚合酶的性质、样本以及STR的基序组成等因素均可能参与了这一过程。  相似文献   

19.
We devised a simple DNA extraction procedure suitable for STR typing of urine sample. Use of a commercially available DNA/RNA extraction kit equipped with a silica-gel-based membrane made it possible to omit the recovery of urinary nucleated cells by sedimentation before the extraction. Successful genotyping of the TH01, HumTPO and multiplex STRs was achieved using aliquots of urine as small as 100 microL. Furthermore, application of this DNA extraction procedure to frozen urine samples provided STR allele results comparable to results obtained from fresh samples. Therefore, this extraction procedure is considered to be effective for STR typing of urine samples in both the frozen and aqueous state. Furthermore, addition of sodium azide to fresh urine samples prolonged their storage duration even at room temperature.  相似文献   

20.
《Science & justice》2020,60(4):388-397
The Quantiplex® Pro RGQ kit quantifies DNA in a sample, supports the detection of mixtures and assesses the extent of DNA degradation based on relative ratios of amplified autosomal and male markers. Data show no significant difference in the accuracy and sensitivity of quantification between this and the Promega PowerQuant® System, both detecting the lowest amount of DNA tested, 4 pg. Laboratory controlled mixed male:female DNA samples together with mock sexual assault samples were quantified across a range of mixture ratios. Analysis software detected mixed DNA samples across all ratios for both quantification kits. Subsequent STR analysis using the Investigator® 24Plex QS Kit was able to corroborate mixture detection down to 1:25 male:female DNA ratios, past which point mixtures appeared identical to single-source female samples. Analysis software also detected laboratory degraded DNA samples, with data showing a positive trend between the Degradation Index (DI) and length of time of sonication. When used on ancient remains the assay was able to triage samples for further analysis, and STR profiles were concordant with DNA quantification results in all instances. STR analyses of laboratory-controlled sensitivity, mixture, and degradation studies supports the quality metric obtained from quantification. These data support the use of the Quantiplex® Pro RGQ kit for sample screening and quantification in forensic casework and ancient DNA studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号