首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   71篇
  免费   2篇
工人农民   2篇
世界政治   1篇
法律   68篇
政治理论   1篇
综合类   1篇
  2024年   8篇
  2023年   43篇
  2021年   10篇
  2020年   3篇
  2018年   1篇
  2016年   1篇
  2013年   2篇
  2006年   2篇
  2003年   1篇
  1998年   1篇
  1995年   1篇
排序方式: 共有73条查询结果,搜索用时 15 毫秒
41.
The recovery of identifiable fingerprints from fired cartridge cases is challenging. Therefore, the characterization of chemical modifications and their effects on fingerprint integrity post-firing is essential. In this study, the primary fingerprint lipids, including myristic acid, pentadecanoic acid, palmitoleic acid, palmitic acid, stearic acid, squalene, and cholesterol in fired and unfired cartridges, were extracted with acetonitrile, followed by derivatization using N,O-Bis(trimethylsilyl)trifluoroacetamide with 1% trimethylchlorosilane (BSTFA/1%TMCS). Squalane was used as the internal standard, and all quantifications were performed using gas chromatography coupled with mass spectrometry using a triple-quadrupole mass filter. All lipids identified in the unfired cartridges were also detected in the fired cartridges, and statistical analysis using Student's t-test and F tests was performed with a 95% confidence level. The concentration of lipids in the unfired cartridges was found to be similar to that detected in the fired cartridges, except for squalene, the recovery of which was 28% lower in the fired cartridges.  相似文献   
42.
The rise of fentanyl and fentanyl analogs in the drug supply pose serious threats to public health. Much of these compounds enter the United States through shipping routes. Here we provide a method for fentanyl screening and analysis that utilizes pressure-sensitive adhesive (PSA) lined paper to recover drug residues from parcel-related surfaces. The paper used is commercially available repositionable notes (also called post-it or sticky notes). From this paper, mass spectra were obtained by paper spray-mass spectrometry (PS-MS), where PSA paper served as both a sampling and analysis substrate. Seven fentanyl-related compounds were analyzed: fentanyl, 4-anilino-N-phenethylpiperidine (4-ANPP), N,1-diphenethyl-N-phenylpiperidin-4-amine (phenethyl-4-ANPP), valerylfentanyl, 4-fluoroisobutyrylfentanyl (4-FIBF), carfentanil, and p-fluorofentanyl. These compounds were recovered by PSA paper and identified by PS-MS from packaging tape and plastic at 50 ng and from cardboard and shipping labels at 100 ng. The impact of cutting agents on PS-MS analysis of fentanyl analogs was explored. No trends of analyte suppression were found at high concentrations of the cutting agents caffeine, diphenhydramine, and lidocaine when recovered from surfaces. A cartridge that required no precise cutting of PSA paper prior to sampling or analysis was evaluated for use in PS-MS for fentanyl screening. Recovery and detection of fentanyl from plastic sheeting was demonstrated with this cut-free cartridge. The cut-free cartridge showed somewhat less consistency and lower analyte signal than the standard cartridge, but performance was suitable for potential screening applications. In combining PSA surface sampling with PS-MS for drug screening, both sampling and detection of fentanyl-related compounds is simple, rapid, and low-cost.  相似文献   
43.
Forensic casework samples often include human hairs, teeth, and bones. Hairs with roots are routinely processed for DNA analysis, while rootless hairs are either not tested or processed using mitochondrial DNA. Bones and teeth are submitted for human remains identifications for missing persons and mass disaster cases. DNA extraction from these low templates and degraded samples is challenging. The new InnoXtract DNA extraction method utilizes magnetic beads that are optimized to bind small DNA fragments, as small as 100 base pairs, to purify high-yield DNA from compromised samples. This validation study evaluates InnoXtract's ability to obtain amplifiable DNA from samples such as rootless hairs and skeletal remains. Studies performed include sensitivity, stability, repeatability, reproducibility, non-probative samples, and comparison to standard organic extractions. Sensitivity studies demonstrate average yield recoveries ranging from 53% to 100% and 73% to 85% for the InnoXtract hair and bone methods, respectively. Studies demonstrate consistent results across a range of sample types, such as insulted and un-insulted bone and teeth, as well as hair shafts from donors of various ages, gender, race, and hair characteristics. The InnoXtract bone method outperformed organic extraction. The method was successfully automated on a MagMAX™ Express-96, with recoveries over 70% relative to the manual version. InnoXtract has the potential as an automated high-throughput, high-yield bone extraction method with 6 h of total extraction time for up to 96 samples. The validation study results demonstrate that the InnoXtract kits produce high-yield and high-quality DNA from compromised bone, teeth, and hair shaft samples.  相似文献   
44.
Ethanol stability in preserved antemortem blood has been widely studied since it is a common practice in cases involving suspected impaired driving to collect antemortem blood in evacuated blood tubes containing sodium fluoride. In some situations, antemortem blood is submitted to a forensic laboratory for ethanol analysis in evacuated blood tubes that contain only an anticoagulant. There has been limited research on ethanol stability in antemortem blood stored without a preservative. On two occasions, antemortem blood was collected from five ethanol-free individuals into 6-ml Vacutainer® tubes containing only 10.8 mg potassium EDTA. The blood tubes were spiked with ethanol to approximately either 0.08 or 0.15 g/dl. Dual-FID headspace gas chromatography was used to analyze 58 blood tubes, 29 from each session, for ethanol 1 day after sample collection and again after 1 year of refrigerated storage (~4°C). Statistically significant decreases in ethanol were detected at the 0.05 level of significance. Mean decreases in ethanol after 1 year of storage for the 0.08 and 0.15 g/dl samples were 0.013 and 0.010 g/dl, respectively. The mean ethanol decrease across all tubes was 0.012 g/dl. The range of decreases for the 58 blood tubes was 0.003–0.018 g/dl. The mean ethanol decreases measured in this unpreserved antemortem blood are comparable in magnitude to those previously observed in antemortem blood containing sodium fluoride after 1 year of refrigerated storage. Ethanol did not increase in the antemortem blood samples despite the absence of sodium fluoride.  相似文献   
45.
Optical tweezers have a wide range of uses for mechanical manipulation of objects in the microscopic range. This includes both living and static cells in a variety of biomedical and research applications. Single-focus optical tweezers, formed by focusing a laser beam through a high numerical aperture immersion objective, create a significant force, which enables controlled transport of a variety of different cell types and morphologies in three dimensions. Optical tweezers have been previously reported to capture and separate spermatozoa from a reconstituted simulated postcoital sample. We report herein the development of a simplified, more efficient cell transfer protocol that can separate and isolate both spermatozoa as well as leukocytes, with similar efficiencies as those previously reported. The new cell transfer method was used to separate sperm cells from a reconstituted mixture of spermatozoa and vaginal epithelial cells, with complete STR profiles developed from 50 cells with little evidence of contribution from the female contributor to the mixture. This modified protocol was then used to separate 21 samples of enriched leukocytes, with trapped cells ranging from 5 to 22 cells. Complete STR profiles were developed from as few as 10 leukocytes. Thus, with minimal sample preparation and a short trapping time, this method has the potential to provide an alternative to traditional differential extraction methods for separation of sperm:nonsperm mixtures while also providing versatility for separation of cells with differing morphologies.  相似文献   
46.
47.
We have developed a technique that allows investigators to confirm the presence of blood, semen, and/or saliva in a crime scene sample. It is a confirmatory test where multiple samples can be processed in less than an hour, and it is potentially portable, permitting samples to be processed at the crime scene. Samples at a scene giving a positive result can be further processed while those failing to do so may be ignored. There is a large and growing backlog of DNA evidence in the USA, slowing down the criminal justice system. This backlog has continued to grow despite an increase in the ability to process evidence faster. This technique uses quantum dot molecular beacons to test for tissue‐specific RNA species, identifying particular body fluids. We have demonstrated the tissue specificity of molecular beacons for blood, semen, and saliva.  相似文献   
48.
49.
Latent fingerprints were successfully visualized using fluorescence lifetime imaging (FLIM) on paper which emits strong fluorescence with a lifetime close to that of fingerprints and thus from which it is difficult for time-resolved spectroscopy to visualize fingerprints. Latent fingerprint samples on paper were excited using a 450 nm or 532 nm nanosecond pulsed-laser, and time-resolved fluorescence images were obtained at a delay time of 6–16 ns in intervals of 1 ns, to the excitation pulse. The excitation beam was expanded using a lens, and the fluorescence from the fingerprints was captured using an intensified CCD camera. Because of the large fluorescence intensity of the background paper of approximately two to four orders of magnitude larger than that of the fingerprint, the fingerprint was not visualized on each fluorescence image by time-resolved spectroscopy. However, the fingerprint was visualized in a FLIM image constructed using a series of the fluorescence images for the case with the fluorescence intensity of the background paper being four orders of magnitude larger than that of the fingerprint. The difference in fluorescence lifetime in the FLIM image of the visualized fingerprint and background paper was in the order of 0.1 ns, which was an order of magnitude smaller than the inherent fluorescence lifetime of a few nanoseconds for the fingerprints and paper. It was demonstrated that, at a background fluorescence intensity with a certain order of magnitude larger than that of fingerprints, FLIM has the potential to visualize latent fingerprints which cannot be visualized by time-resolved spectroscopy.  相似文献   
50.
One of Indonesia characters is welfare state, reflected in Republic Indonesia Constitution in 1945 (UUD NRI year 1945) on Preamble paragraph 4 mentioning the general welfare is the primary aim of the state. Provision of Article 33 paragraph (2), (3), and (4) UUD NRI year 1945 as lives of many people that natural resources inform of water for the greatest prosperity of people's and controlled by state. This is in line with the Constitution Act No. 7 year 2004 on water resources, focus on welfare of people and based on the reflection of democracy spirit. Based on the constitution of Local Government Act No. 32 year 2004, the important role to support the achievement of social welfare problems associated with water (ground water), is crucial. However, the Presidential Decree RI No. 36 year 2010 which provides space for the foreigners to invest in water exploitation orientation, and there was interest~politic of law, so the local government at the beginning prioritize on the welfare of the local people turned into the realm of economic interest to revenue for local government. Based on the statement above, so the problems of people's welfare, democracy and justice are neglected.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号