There are specific challenges related to forensic dental radiology and difficulties in aligning X‐ray equipment to teeth of interest. Researchers used 3D printing to create a new device, the combined holding and aiming device (CHAD), to address the positioning limitations of current dental X‐ray devices. Participants (N = 24) used the CHAD, soft dental wax, and a modified external aiming device (MEAD) to determine device preference, radiographer's efficiency, and technique errors. Each participant exposed six X‐rays per device for a total of 432 X‐rays scored. A significant difference was found at the 0.05 level between the three devices (p = 0.0015), with the MEAD having the least amount of total errors and soft dental wax taking the least amount of time. Total errors were highest when participants used soft dental wax—both the MEAD and the CHAD performed best overall. Further research in forensic dental radiology and use of holding devices is needed. 相似文献
A rapid, accurate, precise, reproducible, economical, and environmentally gentle method using capillary electrophoresis (CE) is presented for the routine analysis of methamphetamine, amphetamine, MDA, MDMA, MDEA, and cocaine in seized drugs. The methodology uses a 32 cm by 50 microm capillary (length to detector 23.5 cm) with a commercially available buffer kit and diode array UV detection. Dynamic coating of the capillary surface is accomplished by flushing with base for 1 min, a proprietary polycation for 1 min, and then a proprietary polyanion for 2 min. This approach provides a relatively high and stable electroosmotic flow (EOF), even at low pHs. The background electrolyte (BGE) contains 75 mM phosphate buffer (pH 2.5) with the same polyanion as above. Using this methodology, amphetamine, methamphetamine, MDA, MDMA, MDEA, and an internal standard (n-butylamphetamine) are baseline resolved in less than 5 min. The run-to-run migration time %RSDs and peak area %RSDs are typically <0.3% and <2.1%, respectively. The day-to-day and capillary-to-capillary migration time %RSDs are <1.5% and <2.1%, respectively. The %RSDs of the relative migration times compared with the internal standard on a day-to-day and capillary-to-capillary basis are <0.2% and <0.06%, respectively. The linear dynamic range using peak areas range from 0.003 to 0.10 mg/mL. The correlation coefficients are >0.9998, with all calibration curves passing at or near the origin. Similar data are obtained for cocaine and its internal standard henyltoloxamine. None of the compounds usually encountered in illicit samples interfere with the target compound (e.g., methamphetamine and cocaine) or the internal standard. Quantitative results for synthetic mixtures and seized exhibits are in good agreement with actual values, and also with results obtained from other techniques. The relatively high EOF for the dynamically coated capillary system allows for the screening of basic, acidic, and neutral adulterants in drug seizures; identification is facilitated by the use of automated UV library searches. 相似文献
Relatively few studies have considered the impact of the COVID-19 pandemic on intimate partner violence (IPV) advocates or the agencies where they work. In this study, based on United States IPV advocates’ experiences working with survivors during the COVID-19 pandemic, we conducted interviews to explore: 1) personal challenges and resilience working as IPV advocates during the COVID-19 pandemic; 2) how agencies adapted to the pandemic to support IPV survivors and advocates; and 3) specific needs and challenges of culturally-specific agencies. We conducted semi-structured interviews with 53 IPV advocates from June to November 2020. Participants were included if they worked directly with survivors, identified as an IPV advocate, worked at a US-based agency, and spoke and understood English. We created a sampling matrix to ensure adequate representation from IPV advocates serving survivors from communities which have been marginalized. Interviews were conducted through a virtual platform by a trained member of the research team. We used an inductive thematic analysis approach, with weekly coding meetings to resolve discrepancies in coding. Five themes emerged from the data: 1) IPV advocates described how working as an IPV advocate during the COVID-19 pandemic impacted them personally; 2) agencies developed new methods of addressing IPV advocates’ needs; 3) agencies developed new solutions to address pandemic-related client needs; 4) transitioning advocacy work to virtual formats created challenges but also opportunities and; 5) pandemic limitations and impacts compounded pre-pandemic challenges for culturally specific agencies. IPV advocates are frontline workers who have played essential roles in adjusting services to meet survivor needs during the COVID-19 pandemic while simultaneously coping with pandemic impacts on themselves and their agencies. Developing inter-agency collaborations and promoting advocates’ safety and wellbeing during future public health crises will help support IPV survivors.
Crime, Law and Social Change - Justice as a concept has permeated sociolegal scholarship in the U.S. since the founding of Law and Society as a field in the mid 1960s. Much of this scholarship has... 相似文献
Several different methods can be employed to test for gunshot residue (GSR) on a decedent's hands, including scanning electron microscopy with energy dispersive x-ray (SEM/EDX) and inductive coupled plasma-atomic emission spectrometry (ICP-AES). In part I of this 2-part series, GSR results performed by SEM/EDX in undisputed cases of suicidal handgun wounds were studied. In part II, the same population was studied, deceased persons with undisputed suicidal handgun wounds, but GSR testing was performed using ICP-AES. A total of 102 cases were studied and analyzed for caliber of weapon, proximity of wound, and the results of the GSR testing. This study found that 50% of cases where the deceased was known to have fired a handgun immediately prior to death had positive GSR results by ICP/AES, which did not differ from the results of GSR testing by SEM/EDX. Since only 50% of cases where the person is known to have fired a weapon were positive for GSR by either method, this test should not be relied upon to determine whether someone has discharged a firearm and is not useful as a determining factor of whether or not a wound is self-inflicted or non-self-inflicted. While a positive GSR result may be of use, a negative result is not helpful in the medical examiner setting as a negative result indicates that either a person fired a weapon prior to death or a person did not fire a weapon prior to death. 相似文献