首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   249篇
  免费   13篇
各国政治   10篇
工人农民   42篇
世界政治   13篇
外交国际关系   12篇
法律   158篇
中国政治   2篇
政治理论   24篇
综合类   1篇
  2024年   8篇
  2023年   48篇
  2022年   1篇
  2021年   15篇
  2020年   14篇
  2019年   11篇
  2018年   14篇
  2017年   12篇
  2016年   17篇
  2015年   10篇
  2014年   11篇
  2013年   29篇
  2012年   11篇
  2011年   9篇
  2010年   5篇
  2009年   4篇
  2008年   10篇
  2007年   6篇
  2006年   5篇
  2005年   3篇
  2004年   5篇
  2003年   3篇
  2002年   2篇
  1998年   1篇
  1997年   2篇
  1996年   2篇
  1995年   2篇
  1987年   2篇
排序方式: 共有262条查询结果,搜索用时 15 毫秒
41.
Novel synthetic opioids contribute considerably to the opioid epidemic, especially with the frequent emergence of structurally similar compounds. This case report describes a fatal intoxication involving 2-methyl AP-237. A 54-year-old Caucasian male was found deceased from an apparent drug overdose. A plastic container labeled “2MAP” and a cut straw were found in the decedent's backpack at the scene. A white substance found in the container tested positive for fentanyl by field testing. According to his medical history, the decedent was treated for a drug overdose 3 years prior to his death. With no diagnostic findings at autopsy, the case was submitted for toxicological analysis. An unknown substance was detected in peripheral blood and urine using gas chromatography with nitrogen phosphorous detection (GC-NPD). Further testing was conducted using gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) which confirmed the presence of 2-methyl AP-237 and potential metabolites in blood and urine. Quantitation by GC-NPD revealed concentrations of 2-methyl AP-237 in blood and urine at 480 ng/mL and 4200 ng/mL, respectively. The toxicological analysis also identified and quantitated alprazolam in the blood at 55 ng/mL. Additionally, the metabolism of 2-methyl AP-237 was investigated and three hydroxylated metabolites were identified in peripheral blood and urine. Limited literature is available for the detection and quantitation of 2-methyl AP-237 in postmortem specimens. Given the toxicological findings with unremarkable autopsy findings, this case is an example of a fatal intoxication involving 2-methyl AP-237.  相似文献   
42.
Anti-forensic technology can play an effective role in protecting information, but it can make forensic investigations difficult. Specifically, file-wiping permanently erases evidence, making it challenging for investigators to determine whether a file ever existed and prolonging the investigation process. To address this issue, forensic researchers have studied anti-forensic techniques that detect file-wiping activities. Many previous studies have focused on the effects of file-wiping tools on $MFT, $LogFile, and $DATA, rather than on Windows artifacts. Additionally, previous studies that have examined Windows artifacts have considered different artifacts, making it difficult to study them in a comprehensive manner. To address this, we focused on analyzing traces in 13 Windows artifacts of 10 file-wiping tools' operations in the Windows operating system comprehensively. For our experiments, we installed each file-wiping tool on separate virtual machines and checked the traces that the tools left behind in each artifact. We then organized the results in a database format. Our analysis revealed that most of the tools left traces on other artifacts, except for JumpList, Open&SavePidlMRU, and lnk. There were also some cases where traces remained on the other three artifacts. Based on our research, forensic investigators can quickly identify whether a file-wiping tool has been used, and it can assist in decision-making for evidence collection and forensic triage.  相似文献   
43.
The secondary dentin deposition that occurs after the tooth formation process results in a decrease in pulp cavity volume in adolescents and adults. The purpose of this critical review was to correlate pulpal and/or dental volume on cone-beam computed tomography (CBCT) with chronological age approximation. A subobjective was to investigate which methodology and CBCT technical parameters would be most appropriate to evaluate this correlation. This critical review followed the PRISMA guidelines, and it was conducted by a search through PubMed, Embase, SciELO, Scopus, Web of Science, Cochrane Library databases, as well as gray literature. Primary studies that used pulp volume, or pulp chamber to tooth volume ratio measured using CBCT were included. Seven hundred and eight indexed and 31 non-indexed records were identified. A qualitative analysis was performed including 25 selected studies with a total of 5100 individuals, age ranging from 8 to 87 years without sex predilection. The most used method was pulp volume/tooth volume. CBCT voxel size ranged between 0.09 and 0.5. Manual segmentation associated with threshold algorithms was used in most of the studies. Correlation between the pulp volume/tooth volume ratio was moderate: −0.66 for the upper central incisors, −0.59 for upper canines and −0.56 for lower canines. High heterogeneity was observed among the studies. It is concluded that pulp volume should be used with caution in age estimation. Evidence supports the preferable use of upper incisors with pulp volume/tooth volume ratio for age estimation. There is not enough evidence that voxel size interferes in age estimation by pulp volume.  相似文献   
44.
The storage and use of explosives is regulated at the state and federal level, with a particular focus on physical security and rigorous accounting of the explosive inventory. For those working with explosives for the training and testing of explosive-detecting canines, cross-contamination is an important concern. Hence, explosives intended for use with canine teams must be placed into secondary storage containers that are new, clean, and airtight. A variety of containers meet these requirements and include screw-top glass jars (e.g., mason jars). However, an additional need from the explosive-detecting canine community is secondary containers that can also be used as training aids whereby the volatiles emitted by explosives are emitted in a predictable and stable manner. Currently, a generally accepted method for the storage of explosives and controlled emission of explosive vapor for canine detection does not exist. Ideally, such containers should allow odor to escape from the training aid but block external contaminates such as particulates or other volatiles. One method in use places the explosive inside a permeable cotton bag when in use for training and then stores the cotton bag inside an impermeable nylon bag for long-term storage. This paper describes the testing of an odor permeable membrane device (OPMD) as a new way to store and deploy training aids. We measured the evaporation rate and flux of various liquid explosives and volatile compounds that have been identified in the headspace of actual explosives. OPMDs were used in addition to traditional storage containers to monitor the contamination and degradation of 14 explosives used as canine training aids. Explosives were stored individually using traditional storage bags or inside an OPMD at two locations, one of which actively used the training aids. Samples from each storage type at both locations were collected at 0, 3, 6, and 9 months and analyzed using Fourier Transform Infrared (FTIR) Spectroscopy and Gas Chromatography–Mass Spectrometry (GC–MS) with Solid-Phase Microextraction (SPME). FTIR analyses showed no signs of degradation. GC–MS identified cross-contamination from ethylene glycol dinitrate (EGDN) and/or 2,3-dimethyl-2,3-dinitrobutane (DMNB) across almost all samples regardless of storage condition. The contamination was found to be higher among training aids that were stored in traditional ways and that were in active use by canine teams.  相似文献   
45.
This work presents a data survey regarding the qualitative chemical analysis of drugs seized by the Police in the state of Minas Gerais between July 2017 and June 2022, including an evaluation of labeling of 265 samples of anabolic androgenic steroids (AAS) seized in 2020. The Active Pharmaceutical Ingredients (API) present in the samples were identified through chemical analysis and classified by system Anatomical Therapeutic Chemical (ATC) methods. Analysis of the labeling information for 265 samples of AAS followed the guidance of legislation RDC 71 (2009) from ANVISA. For this study 6355 seized pharmaceuticals underwent qualitative chemical analysis that corresponded to 7739 APIs successfully identified and classified. Among the components studied AAS, psychostimulants, anesthetics, and analgesics were the most commonly examined. AAS seized and tested increased by over 100% and for the majority of the samples analyzed were found to not match the labeling on the packaging. In the meantime, anti-obesity drugs presented a prominent increase of 400% from 2020/1 to 2021/2, during covid-19 quarantine. Seized pharmaceuticals and tests can support information in the planning of public health and safety policies.  相似文献   
46.
Human hairs are one of the most commonly encountered items of trace evidence. Currently, conventional methods for hair analysis include microscopic comparison and DNA analysis (nuclear and mitochondrial). Each approach has its own drawbacks. Hair proteins are stable and offer an alternative to DNA testing, as demonstrated with proteomics for distinguishing humans. However, proteomics is complicated and requires identifying peptides to remain intact following harsh sample preparation methods. Alternatively, the actual amino acid content of a hair sample may also offer important identifying information and actually requires proteins and peptides to be broken down completely rather than remaining intact. This study evaluated the discriminating power of using hair amino acid ratios to differentiate hair samples from 10 unrelated individuals with dark colored hair. Hair proteins were digested, derivatized, and analyzed using gas chromatography–mass spectrometry. Amino acid ratios were calculated for each individual and comparisons using ANOVA and post-hoc pairwise t-test with Bonferroni correction were made with amino acid ratios for individuals. Overall, out of the 45 possible pairwise comparisons between all hair samples, 38 (84%) were differentiable. Out of the 36 possible pairwise comparisons between brown haired individuals, 32 (89%) were considered differentiable using univariate statistics. Multivariate statistics were also attempted but, overall, univariate models were sufficient for exclusionary purposes. These results indicate that amino acid ratio analysis can potentially be used as an exclusionary method using hair if DNA analysis cannot be performed, or to corroborate conclusions made following microscopic analysis.  相似文献   
47.
48.
Political ideology is an increasingly powerful force in support of public policy. Historically, nuclear energy has found more support among political conservatives. This study updates the literature on political ideology and support for nuclear energy by examining how political ideology is associated with perceptions of nuclear energy and trust of nuclear information sources. After excluding participants with incomplete data, and participants within 50 miles of a nuclear reactor, the analytical sample size for the analysis examining political ideology and perceptions of nuclear energy was 4153. The analytical sample includes a total of 1035 participants within a 50-mile radius of INL, 710 participants from within Idaho who lived further than 50 miles from INL, 1899 participants from other states (more than 50 miles from a nuclear reactor), and 509 Non-Idaho participants living within 50 miles of a nuclear reactor. Logistic regression was used to determine how political ideology was associated with perceptions of nuclear energy and trust in different sources regarding radioactive waste, after controlling for demographics and location. While liberal participants near INL were less favorable towards nuclear energy, and more trusting in impact scientists to tell the truth about radioactive waste than their conservative counterparts, this was not consistent across the US. Our findings reveal the complexity of political ideology and the perceptions of nuclear issues and how proximity influences perceptions. The perceptions of political moderates were particularly important in providing a more complex understanding of political ideology and nuclear energy issues.  相似文献   
49.
While canines are most commonly trained to detect traditional explosives, such as nitroaromatics and smokeless powders, homemade explosives (HMEs), such as fuel–oxidizer mixtures, are arguably a greater threat. As such, it is imperative that canines are sufficiently trained in the detection of such HMEs. The training aid delivery device (TADD) is a primary containment device that has been used to house HMEs and HME components for canine detection training purposes. This research assesses the odor release from HME components, ammonium nitrate (AN), urea nitrate (UN), and potassium chlorate (PC), housed in TADDs. Canine odor recognition tests (ORTs) were used with analytical data to determine the detectability of TADDs containing AN, UN, or PC. Headspace analysis by gas chromatography/mass spectrometry (GC/MS) with solid-phase microextraction (SPME) or online cryotrapping were used to measure ammonia or chlorine, as well as other unwanted odorants, emanating from bulk AN, UN, and PC in TADDs over 28 weeks. The analytical data showed variation in the amount of ammonia and chlorine over time, with ammonia from AN and UN decreasing slowly over time and the abundance of chlorine from PC TADDs dependent on the frequency of exposure to ambient air. Even with these variations in odor abundance, canines previously trained to detect bulk explosive HME components were able to detect all three targets in glass and plastic TADDs for at least 18 months after loading. Detection proficiency ranged from 64% to 100% and was not found to be dependent on either age of material.  相似文献   
50.
Synthetic cannabinoids are sprayed onto plant material and smoked for their marijuana‐like effects. Clandestine manufacturers modify synthetic cannabinoid structures by creating closely related analogs. Forensic laboratories are tasked with detection of these analog compounds, but targeted analytical methods are often thwarted by the structural modifications. Here, direct analysis in real time coupled to accurate mass time‐of‐flight mass spectrometry (DART‐TOF‐MS) in combination with liquid chromatography quadruple time‐of‐flight mass spectrometry (LC‐QTOF‐MS) are presented as a screening and nontargeted confirmation method, respectively. Methanol extracts of herbal material were run using both methods. Spectral data from four different herbal products were evaluated by comparing fragmentation pattern, accurate mass and retention time to available reference standards. JWH‐018, JWH‐019, AM2201, JWH‐122, 5F‐AKB48, AKB48‐N‐(4‐pentenyl) analog, UR144, and XLR11 were identified in the products. Results demonstrate that DART‐TOF‐MS affords a useful approach for rapid screening of herbal products for the presence and identification of synthetic cannabinoids.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号