首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   58篇
  免费   0篇
各国政治   1篇
工人农民   3篇
世界政治   3篇
法律   42篇
政治理论   9篇
  2024年   6篇
  2023年   27篇
  2021年   6篇
  2013年   2篇
  2011年   1篇
  2004年   1篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
  1998年   2篇
  1992年   2篇
  1991年   1篇
  1990年   1篇
  1986年   1篇
  1985年   1篇
  1979年   1篇
  1977年   2篇
  1966年   1篇
排序方式: 共有58条查询结果,搜索用时 15 毫秒
51.
Human remains from forensic and bioarcheological contexts are often fragmentary, requiring methods for estimating a forensic profile that are based upon limited skeletal features. In 2017, Berg and Keryhercz created an online application, (hu)MANid, that provides sex and ancestry estimation from mandibular morphoscopic traits and linear measurements. In this study, we examine the utility of the (hu)MANid application in a diverse, urban US adult sample (aged 20–45; n = 143) derived from computed tomography (CT) scans. We secondarily conduct a preliminary analysis of the program's utility in a sample of adolescents (aged 15–17; n = 40). Six morphoscopic, and eleven morphometric traits were recorded as directed by the literature associated with the (hu)MANid program. Percent correct classification and posterior predictive values were calculated for the sex and ancestry estimations output by the program; chi-squared tests were employed to compare self-reported and predicted ancestry. In the adult sample, sex was accurately predicted for 75.52% of the sample. Ancestry prediction, however, was less favorable ranging from 19.3% to 50% correct. For the adolescent sample, correct sex estimation (45%) did not surpass what could occur by chance alone, though ancestry prediction fared better than in the larger adult sample (percent correct prediction overall average: 47.5%, range 35.71%–71.43%). The (hu)MANid application shows utility for use with CT scan-derived adult samples for sex estimation, but caution is warranted for ancestry estimation and use with samples that may not have reached full adult maturity.  相似文献   
52.
Xylazine sedative, muscle relaxant, and analgesic used in a veterinary setting. Although xylazine was never approved for therapeutic use in humans, it has become popular in the street drug market as a cutting or bulking agent in the fentanyl and heroin supply. Recently, there has been a significant increase in the detection of xylazine in postmortem forensic toxicology casework. Xylazine can be identified during routine toxicology screening utilizing instrumentation such as gas chromatography–mass spectrometry and liquid chromatography–mass spectrometry. Using the Miami-Dade Medical Examiner's LIMS system, all cases received between 2015 and 2022 in which xylazine was reported were reviewed. The cases studied include accidental drug overdose deaths in Miami-Dade County as well as Collier County (Naples), Florida. In total, there are 170 cases; the majority are accidental polydrug overdoses involving White males between the ages of 25 and 44 years old. Of the 170 cases, 37% listed xylazine as the cause of death. 13% of cases contained only xylazine and fentanyl while the remaining 87% of deaths were attributed to polydrug toxicity involving two or more substances. The prevalence of xylazine can be attributed to its increasing popularity rather than an increase in caseload. In 2019, xylazine was present in only 4% of all accidental fentanyl overdoses. By 2021, this percentage has increased sixfold, with xylazine present in 24% of all accidental fentanyl overdoses. Despite a decrease in fentanyl overdoses in 2022, the percentage of xylazine detection remained the same.  相似文献   
53.
In order to detect latent fingerprints that could be damaged by liquid or powder reagents, non-destructive processes such as gaseous reagents have been developed. In this report, we propose the use of fine mist generated when hot vapor of high-boiling-point liquids is rapidly cooled by surrounding air for fingermark detection. Octyl acetate (OA), 2-phenoxyethanol (2PE), and methyl decanoate (MD) were found to efficiently produce mist when heated to 230°C. By combining these liquids with p-dimethylaminocinnamaldehyde (DMAC) and cyanoacrylate (CN), our team demonstrated effective fluorescence staining of cyano-treated fingermarks using DMAC/OA misting or DMAC/2PE misting, and one-step fluorescence detection of latent fingermarks without cyanoacrylate treatment using DMAC/OA/CN misting or DMAC/MD/CN misting. Fingermark fluorescence was efficiently observed by excitation with a blue LED light (max. wavelength 470 nm) equipped with an interference filter and passing through a 520 nm long-pass filter. We successfully obtained fluorescent images from fingermarks on several substrate materials using the developed misting method.  相似文献   
54.
The need to detect fentanyl and its analogs in the field is an important capability to help prevent unintentional exposure or overdose on these substances, which may result in death. Many portable methods historically used in the field by first responders and other field users to detect and identify other chemical substances, such as hazardous materials, have been applied to the detection and identification of these synthetic opioids. This paper describes field portable spectroscopic methods used for the detection and identification of fentanyl and its analogs. The methods described are automated colorimetric tests including lateral flow assays; vibrational spectroscopy (mid-infrared and Raman); gas chromatography–mass spectrometry; ion mobility spectrometry, and high-pressure mass spectrometry. In each case the background and key details of these technologies are outlined, followed by a discussion of the application of the technology in the field. Attention is paid to the analysis of complex mixtures and limits of detection, including the required spectral databases and algorithms used to interrogate these types of samples. There is also an emphasis on providing actionable information to the (likely) non-scientist operators of these instruments in the field.  相似文献   
55.
56.
57.
The opioid epidemic has affected the United States (US) for decades with fentanyl and its analogs accounting for a recent surge in morbidity and mortality. Currently, there is a relative lack of information characterizing fentanyl-related fatalities specifically in the Southern US. A retrospective study was conducted to examine all postmortem fentanyl-related drug toxicities in Travis County, Texas, encompassing Austin (one of the fastest-growing cities in the US), from 2020 to 2022. Fentanyl contributed to 2.6% and 12.2% of deaths submitted for toxicology between 2020 and 2022, respectively, representing a 375% increase in fentanyl-related deaths over this 3-year period (n = 517). Fentanyl-related fatalities primarily occurred in males in their mid-30s. Fentanyl and norfentanyl concentrations ranged from 0.58 to 320 ng/mL and 0.53 to 140 ng/mL with mean (median) concentrations of 17.2 ± 25.0 (11.0) and 5.6 ± 10.9 (2.9) ng/mL, respectively. Polydrug use was present in 88% of cases, with methamphetamine (or other amphetamines) (25%), benzodiazepines (21%), and cocaine (17%) representing the most frequently identified concurrent substances. Co-positivity rates of various drugs and drug classes widely varied over time. Scene investigations reported illicit powder(s) (n = 141) and/or illicit pill(s) (n = 154) in 48% (n = 247) of fentanyl-related deaths. Illicit oxycodone (44%, n = 67) and illicit “Xanax” (38%, n = 59) pills were frequently reported on scene; however, toxicology only identified oxycodone and alprazolam in 2 and 24 of these cases, respectively. The results of this study provide a better understanding of the fentanyl epidemic in this region creating an opportunity to promote increased awareness, shift focus to harm reduction, and aid in minimizing public health risks.  相似文献   
58.
The 4- Aminophenol (4-AP) colorimetric test is a fast, easy-to-use, and cost-effective presumptive assay of cannabis plant material producing different chromophores with THC-rich cannabis (blue color) and with CBD-rich cannabis (pink color). The main drawback of the 4-AP test is a brief observation window where the color rapidly changes to black, limiting the utility of the test. We now report for the first time, the identification of the product chromophores between 4-AP and CBD/THC as well as propose an explanation and a solution for the color degradation of the chromophores. The identification of the chromophores is provided by spectroscopic (UV–Vis), chromatography, and mass spectrometry (TLC and LC-QToF-MS). Oxidation of excess 4-AP (Reagent A) in the presence of NaOH (Reagent B) produces the black color observed for the previously reported 4-AP tests and reported in the literature. The adjustment of reactants concentrations and volumes of 4-AP:THC/CBD to a 1:1 ratio significantly reduces the black oxidation by-product and increases the observation window up to 2 h instead of the previously reported 5–10 min. For the first time, mass spectrometry and chromatography confirmed that the reaction of THC and CBD with 4-AP produced chromophores with m/z (M + H) = 420, consistent with proposed indophenol structures. The TLC method developed confirmed the separation between CBD and THC chromophores. The specificity of the test is also reported, showing false positive results for the presence of THC (blue color) for samples of thyme and oregano. LDA and SIMCA models showed that the optimized 4-AP procedure performs better than the previously reported 4-AP color test.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号