全文获取类型
收费全文 | 44篇 |
免费 | 3篇 |
专业分类
各国政治 | 3篇 |
工人农民 | 1篇 |
世界政治 | 5篇 |
法律 | 31篇 |
中国政治 | 1篇 |
政治理论 | 5篇 |
综合类 | 1篇 |
出版年
2019年 | 1篇 |
2017年 | 1篇 |
2016年 | 2篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 7篇 |
2011年 | 3篇 |
2010年 | 1篇 |
2008年 | 2篇 |
2007年 | 2篇 |
2006年 | 2篇 |
2005年 | 4篇 |
2004年 | 3篇 |
2003年 | 2篇 |
2002年 | 1篇 |
2001年 | 1篇 |
2000年 | 3篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1990年 | 1篇 |
1988年 | 1篇 |
1987年 | 1篇 |
1986年 | 1篇 |
1983年 | 1篇 |
1978年 | 1篇 |
1974年 | 1篇 |
排序方式: 共有47条查询结果,搜索用时 15 毫秒
41.
42.
尽管标签理论能够解释一些犯罪,但是,研究显示,采取非刑罚措施对预防犯罪并未获得太大成功。目前,阻止方案也许能更有效地减少未成年人的再犯罪率。 相似文献
43.
Recently, much attention has been given to benzodiazepines and gamma-hydroxybutyric acid (GHB) related compounds owing to their alleged widespread use as date-rape drugs. Toxicologists would greatly benefit from a screening method that allows for the simultaneous detection of both groups of substances. A new capillary electrophoresis (CE) method has been developed in the micellar mode to accomplish this separation in under 16 min using a sodium dodecyl sulfate (SDS)/sodium tetraborate/boric acid buffer with an acetonitrile organic modifier. Optimization of SDS and organic modifier concentration, along with pH, were performed on a set of standards containing eight benzodiazepines, GHB, gamma-butyrolactone, and the internal standard, sulfanilic acid. The method was shown to have a detection limit of less than 2 microg/ml for five out of eight benzodiazepines with a linear range of 2.5-100 microg/ml. The detection limit for GHB was 32 mg/ml with a linear range to 2500 microg/ml. This method was applied to the rapid analysis of spiked beverages. GHB spiked beverages were monitored after using a series of simple dilutions to determine the effects of time on the drug analysis. Possible interfering peaks from drugs of abuse and artifacts from a variety of different drink combinations were also studied in detail. A one-step liquid-liquid extraction was the only necessary sample pretreatment. 相似文献
44.
45.
Collin OL Niegel C Derhodes KE McCord BR Jackson GP 《Journal of forensic sciences》2006,51(4):815-818
The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for the nine explosives studied. The PDECD has the benefit that it uses a pulsed plasma to generate the standing electron current instead of a radioactive source. The fast separation time limits on-column degradation of the thermally labile compounds and decreases the peak widths, which results in larger peak intensities and a concomitant improvement in detection limits. The combination of short analysis time and low detection limits make this method a potential candidate for screening large numbers of samples that have been prepared using techniques such as liquid-liquid extraction or solid-phase microextraction. 相似文献
46.
47.
The goal of this paper is to describe applications of two recently developed HPLC methods for the analysis and confirmation of the presence of hydrogen peroxide residues in field studies. The procedure utilizes two different HPLC systems, one with post-column derivatization followed by fluorescence detection (HPLC/FD), and the other with electrochemical detection (HPLC/ED). The two systems were utilized to detect hydrogen peroxide in a variety of typical forensic samples including pre- and post-blast samples, as well as a series of environmental control samples. Peroxide-based organic explosives were also examined due to their propensity to produce peroxide residues following detonation. Because samples collected from post-blast scenes are frequently shipped or stored prior to analysis, the effects of storage time, temperature and type of substrate material on the recovery of hydrogen peroxide residues were also investigated. The combined results of the study demonstrate the capability of two HPLC approaches with selective detection in the analysis and investigation of suspected incidents involving peroxide based explosives. 相似文献