全文获取类型
收费全文 | 115篇 |
免费 | 12篇 |
专业分类
各国政治 | 8篇 |
工人农民 | 8篇 |
世界政治 | 15篇 |
外交国际关系 | 5篇 |
法律 | 60篇 |
中国政治 | 1篇 |
政治理论 | 30篇 |
出版年
2023年 | 2篇 |
2022年 | 1篇 |
2021年 | 3篇 |
2020年 | 6篇 |
2019年 | 4篇 |
2018年 | 7篇 |
2017年 | 6篇 |
2016年 | 10篇 |
2015年 | 5篇 |
2014年 | 6篇 |
2013年 | 17篇 |
2012年 | 2篇 |
2011年 | 9篇 |
2010年 | 2篇 |
2009年 | 7篇 |
2008年 | 6篇 |
2007年 | 7篇 |
2006年 | 6篇 |
2005年 | 8篇 |
2004年 | 3篇 |
2003年 | 1篇 |
2002年 | 1篇 |
2001年 | 1篇 |
1997年 | 3篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1988年 | 1篇 |
1965年 | 1篇 |
排序方式: 共有127条查询结果,搜索用时 0 毫秒
111.
The exposition to heavy metal-rich airborne due to fire practicing has forced to the development of heavy metal-free environmental ammunition primers all over the world. Here we characterize the GSR elements present in the Brazilian lead-free ammunition produced by Companhia Brasileira de Cartuchos (CBC) and commercialized by MagTech in the U.S. and Europe under the name CleanRange centerfire cartridges. Both first and second generations of CleanRange in calibers 9 mm Luger, .40 S&W, .380 AUTO and .38 SPL were analyzed and compared to regular Brazilian CBC ammunition by scanning electron microscopy/energy dispersive spectroscopy. Differences in composition and morphology of GSR particles from the two generations of CleanRange were observed. The first generation ammunition (found in Europe) presented spherical particles, being strontium the only unique element detected. The second generation (found in the U.S.) produced irregular particles composed mostly by potassium, aluminum, silicon and calcium. We can conclude that identification of GSR derived from CBC second generation lead-free ammunition in suspects' hands may be impossible without the addition of a distinct metallic taggant in the primer composition by the manufacturer. 相似文献
112.
P Fernandez A M Bermejo M Lopez-Rivadulla A Cruz E Rodriguez A Otero 《Forensic science international》1991,49(2):215-224
The chief clinical and analytical aspects of the suicide of a 21-year-old male with psychiatric problems by parenteral administration of a 200 g/l aqueous solution of paraquat are described. Paraquat levels were determined in plasma, urine, kidney, liver and lung after autopsy. Tissue damage was studied by electron microscopy. The death ensued from pulmonary dysfunction 15 days after hospital admission. 相似文献
113.
Christopher Phillips Anna Barbaro Luís Fernandez Formoso David Ballard Denise Syndercombe Court Ángel Carracedo Maviky Lareu 《Forensic Science International: Genetics Supplement Series》2009,2(1):25-26
We constructed a simple STR pentaplex of new loci recommended as next generation markers for the European Standard Set (ESS) comprising normal-amplicon STRs: D12S391 and D1S1656, plus mini-amplicon STRs: D2S441, D10S1248 and D22S1045. Validation of the pentaplex included evaluation of its ability to amplify DNA from a variety of degraded forensic casework samples. Although the ESS-pentaplex was designed in the first instance to generate allele frequency data to supplement existing databases of established STRs, the multiplex proved to be a valuable tool for the analysis of challenging DNA when certain markers of Identifiler or MiniFiler occasionally failed. 相似文献
114.
Color Stability of Dental Restorative Materials Submitted to Heat Sources,for Forensic Purposes 下载免费PDF全文
Roberto Cesar Biancalana D.D.S. M.Sc. Sergio Augusto de Freitas Vicente D.D.S. M.Sc. Fernanda de Carvalho Panzeri Pires‐de‐Souza D.D.S. M.Sc. Ph.D. 《Journal of forensic sciences》2017,62(2):355-360
During postmortem examination of the dental arches of carbonized victims, dental restorative materials may be found. The aim of this study was to evaluate the effect of heat source action on the color stability of composite resin (CR) and glass ionomer cement (GIC) restorations, to discriminate between them and compare with antemortem dental data. Sixty bovine teeth (30 CR and 30 GIC) were prepared (6 × 6 × 2 mm) and separated into groups (n = 10). The color readouts were taken by spectrophotometer, before and after heat action (100°C, 200°C, 300°C), in an oven for 15 min. There were color alterations for all coordinates (ΔE, ΔL*, Δa* eΔb*) for both materials. GIC presented greater change. The authors concluded that it is possible to distinguish between the materials by the color changes analyzed by instrumental method, helping victim identification. 相似文献
115.
Michelle Wood Marleen Laloup Maria del Mar Ramirez Fernandez Kevin M. Jenkins Michael S. Young Jan G. Ramaekers Gert De Boeck Nele Samyn 《Forensic Science International Supplement Series》2005,150(2-3):227
We present a validated method for the simultaneous analysis of basic drugs which comprises a sample clean-up step, using mixed-mode solid-phase extraction (SPE), followed by LC–MS/MS analysis. Deuterated analogues for all of the analytes of interest were used for quantitation. The applied HPLC gradient ensured the elution of all the drugs examined within 14 min and produced chromatographic peaks of acceptable symmetry. Selectivity of the method was achieved by a combination of retention time, and two precursor-product ion transitions for the non-deuterated analogues. Oral fluid was collected with the Intercept®, a FDA approved sampling device that is used on a large scale in the US for workplace drug testing. However, this collection system contains some ingredients (stabilizers and preservatives) that can cause substantial interferences, e.g. ion suppression or enhancement during LC–MS/MS analysis, in the absence of suitable sample pre-treatment. The use of the SPE was demonstrated to be highly effective and led to significant decreases in the interferences. Extraction was found to be both reproducible and efficient with recoveries >76% for all of the analytes. Furthermore, the processed samples were demonstrated to be stable for 48 h, except for cocaine and benzoylecgonine, where a slight negative trend was observed, but did not compromise the quantitation. In all cases the method was linear over the range investigated (2–200 μg/L) with an excellent intra-assay and inter-assay precision (coefficients of variation <10% in most cases) for QC samples spiked at a concentration of 4, 12 and 100 μg/L. Limits of quantitation were estimated to be at 2 μg/L with limits of detection ranging from 0.2 to 0.5 μg/L, which meets the requirements of SAMHSA for oral fluid testing in the workplace. The method was subsequently applied to the analysis of Intercept® samples collected at the roadside by the police, and to determine MDMA and MDA levels in oral fluid samples from a controlled study. 相似文献
116.
Fernandez Dennis; De Leon Laurie; Kemeny David 《Jnl of Intellectual Property Law & Pract》2006,1(9):593-598
Legal context. Some state legislatures are considering billswhich would require those applying for a drivers licenceto provide one or more biometric identifiers. The US federalgovernment is tending towards eavesdropping on conversationsand investing in data mining efforts while on the other handanti "big-brother" technologies are also emerging to counterthis trend and protect privacy. The demand for technology toprotect privacy will no doubt increase as the demand for defenceand security spending increases. We also live in a world wherebioterrorist acts are a constant threat and therefore demandfor biological detection devices and nanotechnology is growingdaily. Key points. Current technology advances in biometrics, surveillance,biological detection and nanotechnology can be used both toprotect and to jeopardize the security and privacy of individuals.As such, the importance of intellectual property in these areascannot be underestimated. Practical significance. Companies are advised to go onthe offensive. All companies should aggressively protecttheir core technology in numerous facets such as patent protection,copyright, trade marks and trade secrets. In the high tech arenathis is especially important because the demand for securityand privacy necessitates the development of advanced applicationsand in turn the quality of protectable IP for the companiesthat develop the technology increases. Additionally, companiesshould also pursue an offensive strategy that includes analyzingemerging standards and competitor focus so that they can acquirea competitive advantage or secure cross-licensing of anotherstechnology. 相似文献
117.
Palermo MT Di Luigi M Dal Forno G Dominici C Vicomandi D Sambucioni A Proietti L Pasqualetti P 《International journal of offender therapy and comparative criminology》2006,50(6):654-660
Childhood disruptive behaviors can be precursors to later deviance. To verify the efficacy of karate, a complex psychomotor activity that enhances self-regulation and executive skills, as an intervention for externalizing behaviors, 16 children, ranging in age from 8 to 10 years, and meeting diagnostic criteria for oppositional defiant disorder were studied. Eight were randomly assigned to a 10-month Wa Do Ryu karate program, whereas 8 children received no intervention. The children were assigned to a larger karate class, composed of typically developing youngsters. Three domains of temperament--intensity, adaptability, and mood regulation--were measured at the beginning and the end of the training period in all 16 participants. A significant improvement in temperament scale scores was measured in the karate group for all tested items compared to controls. Karate, when properly taught, can be a useful adjunct in multimodal programs aimed at externalizing behavior reduction. 相似文献
118.
Laloup M Del Mar Ramirez Fernandez M Wood M De Boeck G Maes V Samyn N 《Forensic science international》2006,161(2-3):175-179
Oral fluid (collected with the Intercept((R)) device) and plasma samples were obtained from 139 individuals suspected of driving under the influence of drugs and analyzed for Delta(9)-tetrahydrocannabinol (THC), the major psychoactive constituent of cannabis, using a validated quantitative LC-MS-MS method. The first aim of the study was to investigate the correlation between the analytical data obtained in the plasma and oral fluid samples, to evaluate the use of oral fluid as a 'predictor' of actual cannabis influence. The results of the study indicated a good accuracy when comparing THC detection in oral fluid and plasma (84.9-95.7% depending on the cut-off used for plasma analysis). ROC curve analysis was subsequently used to determine the optimal cut-off value for THC in oral fluid with plasma as reference sample, in order to 'predict' a positive plasma result for THC. When using the LOQ of the method for plasma (0.5 ng/mL), the optimal cut-off was 1.2 ng/mL THC in oral fluid (sensitivity, 94.7%; specificity, 92.0%). When using the legal cut-off in Belgium for driving under the influence in plasma (2 ng/mL), an optimal cut-off value of 5.2 ng/mL THC in oral fluid (sensitivity, 91.6%; specificity, 88.6%) was observed. In the second part of the study, the performance of the on-site Dr?ger DrugTest for the screening of THC in oral fluid during roadside controls was assessed by comparison with the corresponding LC-MS-MS results in plasma and oral fluid. Since the accuracy was always less than 66%, we do not recommend this Dr?ger DrugTest system for the on-site screening of THC in oral fluid. 相似文献
119.
Carlos?A.?HemaisEmail author Henrique?M.?Barros Elizabeth?O.?R.?Rosa 《The Journal of Technology Transfer》2005,30(3):303-314
The Brazilian polymer industry (plastics, rubbers, fibers, adhesives, paints, and varnishes) is the fastest growing segment of the Petrochemical Chain. Since the polymer industry is characterized as science based, the capacity to create technology is vital for its long-range survival in the market. This paper analyzes how Brazilian polymer firms maintain their technological competitiveness, explains the main modes of technology transfer, and evaluates the degree of technological dependence of this industry. The methodology consisted of a database built with data from the Brazilian Patent Office. To confirm the findings, interviews were conducted with staff members from seven Brazilian polymer firms. The data base analysis and the interviews reveal that, in spite of the fact that Research and Development (R&D) and technological innovation have a fundamental role in their competitiveness, the firms are technologically dependent upon foreign suppliers. 相似文献
120.
Barcelona 2002: law, ethics, and human rights. Global battle cry: health is a right, not a commodity
Fernandez I 《Canadian HIV/AIDS policy & law review / Canadian HIV/AIDS Legal Network》2002,7(2-3):80-84
Health is a fundamental right, not a commodity to be sold at a profit, argues Irene Fernandez in the second Jonathan Mann Memorial Lecture delivered on 8 July 2002 to the XIV International AIDS Conference in Barcelona. Ms Fernandez had to obtain a special permit from the Malaysian government to attend the Conference because she is on trial for having publicly released information about abuse, torture, illness, corruption, and death in Malaysian detention camps for migrants. This article, based on Ms Fernandez' presentation, describes how the policies of the rich world have failed the poor world. According to Ms Fernandez, the policies of globalization and privatization of health care have hindered the ability of developing countries to respond to the HIV/AIDS epidemic. The article decries the hypocrisy of the industrialized nations in increasing subsidies to farmers while demanding that the developing world open its doors to Western goods. It points out that the rich nations have failed to live up their foreign aid commitments. The article concludes that these commitments--and the other promises made in the last few years, such as those in the United Nations' Declaration of Commitment on HIV/AIDS--can only become a reality if they are translated into action. 相似文献