首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   109篇
  免费   20篇
外交国际关系   4篇
法律   120篇
中国政治   1篇
综合类   4篇
  2023年   1篇
  2022年   4篇
  2021年   5篇
  2020年   7篇
  2019年   6篇
  2018年   4篇
  2017年   3篇
  2016年   7篇
  2015年   7篇
  2014年   4篇
  2013年   6篇
  2012年   9篇
  2011年   4篇
  2010年   11篇
  2009年   8篇
  2008年   9篇
  2007年   11篇
  2006年   6篇
  2005年   2篇
  2004年   2篇
  2003年   1篇
  2001年   3篇
  2000年   3篇
  1999年   1篇
  1997年   1篇
  1994年   1篇
  1992年   1篇
  1983年   2篇
排序方式: 共有129条查询结果,搜索用时 15 毫秒
11.
The elemental composition and postfiring residues of several "lead-free" or "nontoxic" centerfire handgun ammunition types currently available to the general public were examined. Offerings from Winchester, Remington/UMC, Federal and Speer were obtained from retail sources in both .45 ACP and 9 mm when possible. A total of 112 postfiring residue samples (SEM pins) were collected at varying distances from the muzzle, at two distances from target and from the shooter's hands. An additional 20 samples were collected by direct ignition of primers. Qualitative determinations were carried out using scanning electron microscopy (SEM)/electron dispersive spectrometry (EDS) analysis. All types tested contained aluminum (Al), silicon (Si), copper (Cu), and zinc (Zn). Most contain traces of sulfur and calcium. Winchester WinClean and Remington LeadLess contained potassium as the principle ingredient. Federal BallistClean contained barium, while Speer Lawman CleanFire contained strontium. In the main, these compared favorably with manufacturers' MSDS publications and patents granted. The characterizations undertaken here will be of use to the forensic electron microscopist as these formulations gain popularity.  相似文献   
12.
Vacuum metal deposition (VMD) has been previously demonstrated as an effective development technique for latent fingermarks and in some cases has been shown to enhance prints developed with cyanoacrylate (CA) (superglue) fuming. This work utilizes scanning electron microscopy (SEM) to investigate the interactions of the two development techniques when applied to latent fingermarks on low-density polyethylene. CA is shown to act principally on the eccrine deposits around sweat pores, where polymerization results in long polymer fibrils a few 100 nm in width. Subsequent VMD processing results in additional areas of development, for example, between pores. However, the primary mode of deposition of zinc is by interaction with the polymerized CA, the fibrils of which become decorated with zinc nanoparticles. Areas with limited CA deposition and no significant polymerization are also enhanced with the VMD process, resulting in increased print development.  相似文献   
13.
微波消解-扫描电镜联用法在溺死诊断中的应用   总被引:1,自引:1,他引:0  
目的探讨微波消解-扫描电镜联用法在溺死诊断中的应用价值。方法收集已知死因的尸体标本105例,其中水中尸体85例(生前溺死70例,死后抛尸入水15例),陆地自然死亡尸体20例。水中死亡案例同时收集落水处水样。分别用微波消解-扫描电镜联用法(方法 A)和硝酸破机-光镜联用法(方法 B)对上述尸体的离体肺、肝、肾、骨髓组织及水样进行硅藻定性、定量检测。结果①溺死尸体的肺、肝、肾、骨髓中及落水处水样硅藻检出率:A法分别为100%、94.3%、92.9%、82.9%、100%,硅藻检验阳性率为100%;B法分别为90%、62.9%、51.4%、28.6%、92.9%,硅藻检验阳性率为65.7%。②两种方法检出的硅藻种类与落水处水样中硅藻的种类均一致。③两种方法在死后入水尸体离体的肺中也检出少量硅藻(<3个/2g肺组织),但在死后入水尸体的其它脏器及陆地自然死亡尸体脏器中均未检出硅藻。结论微波消解-扫描电镜联用法较硝酸破机-光镜联用法对尸体离体组织脏器中的硅藻检出率高,方法灵敏,定性准确。  相似文献   
14.
Bismuth oxychloride (BiOCl) was the first viable synthetic pearl pigment developed 50 years ago. It was only used for a limited time period in automotive paint (model years 1998–2000), serving to produce luster for a single Chrysler black metallic color. Identification of this pigment in an unknown automotive paint can thus facilitate determination of the vehicle of origin. Bismuth oxychloride imparts effects similar to those produced by silver/white mica pearlescent pigments, and such a pigment was used together with bismuth oxychloride in at least one original equipment manufacturer (OEM) basecoat. Silver/white micas are now used primarily in white pearl tricoat systems. This article describes the identification of bismuth oxychloride and silver/white mica pearlescent pigments in automotive finishes using FT‐IR spectroscopy, X‐ray fluorescence (XRF) spectrometry, and SEM/EDS analysis. Data for some cadmium pigments, which were used in automotive paint several decades ago, are also presented as they produce infrared absorptions similar to that of bismuth oxychloride.  相似文献   
15.
This research demonstrates the value of laser scanning confocal microscopy (LSCM) as a research tool in osteological studies, and diagenetic studies in particular. LSCM combines properties of light and scanning electron microscopy using laser light to excite fluorophores throughout the z-axis, developing a 3-D image. Using differential staining and selecting for specific wavelengths of light, one can image targeted materials. This research is divided into two parts: visualizing bone structures such as proteins and their decompositional products and visualizing diagenesis. Part one of this study utilized pig bones as a means of testing the overall ability of LSCM to fluoresce bone. Twenty-three samples were imaged, including 13 samples from a decompositional study conducted 5 years previous, and 10 “fresh” samples collected from a commercial butcher. This part of the study determined that protein and organic components of the bone could be fluoresced and diagenetic alteration could be imaged. The second part of the study used human samples as a means of imaging and mapping diagenetic alterations. The second part of the study used 13 samples, including 4 clinical, 7 ancient, and 2 modern controls. The pig study used Basic Fuchsin and SlowFade Gold stains, while the human study used toluidine blue. Images were also taken with unstained elements. The results of the non-human study found that a fresh bone fluoresced differently than that of a 5-year subset, while the results of the human study confirmed these findings and determined that the bone diagenesis can be mapped using LSCM.  相似文献   
16.
Concerns over the toxic by‐products produced by traditional ammunition have led to an increase in popularity of nontoxic ammunition. In this work, the chemical composition of six brands of nontoxic ammunition was investigated and compared to that of a road flare, which served as an environmental source with similar composition. Five rounds of each brand were fired while a further five were disassembled and the primer alone was fired. Particles collected from all samples, including the road flare, were analyzed by scanning electron microscopy with energy dispersive X‐ray analysis. Common elements among the different ammunition brands included aluminum, potassium, silicon, calcium, and strontium. Spectra were then subjected to principal components analysis in which association of the primer to the intact ammunition sample was generally possible, with distinction among brands and from the road flare sample. Further, PCA loadings plots indicated the elements responsible for the association and discrimination observed.  相似文献   
17.
Entomological protocols for aging blowfly (Diptera: Calliphoridae) larvae to estimate the time of colonization (TOC) are commonly used to assist in death investigations. While the methodologies for analyzing fly larvae differ, most rely on light microscopy, genetic analysis, or, more rarely, electron microscopy. This pilot study sought to improve resolution of larval stage in the forensically important blowfly Chrysomya rufifacies using high‐content fluorescence microscopy and biochemical measures of developmental marker proteins. We established fixation and mounting protocols, defined a set of measurable morphometric criteria and captured developmental transitions of 2nd instar to 3rd instar using both fluorescence microscopy and anti‐ecdysone receptor Western blot analysis. The data show that these instars can be distinguished on the basis of robust, nonbleaching, autofluorescence of larval posterior spiracles. High‐content imaging techniques using confocal microscopy, combined with morphometric and biochemical techniques, may therefore aid forensic entomologists in estimating TOC.  相似文献   
18.
Forensic practitioners are recommended to dark adapt their eyes prior to conducting evidential searches in the dark. The dark adaptation process remains poorly standardised across the discipline, with little quantified regarding the benefits of such preparative steps. Herein, we report the findings of a study that recruited 50 participants to assess the effectiveness of the Crime-lite Eye?, a darkness adaptation device developed to assist forensic practitioners both in the laboratory and in field. Participants were tasked with searching for the fluorescent signatures left by reaction of 1,8-diazafluoren-9-one (DFO) with amino acids, in a manner akin to the fluorogenic fingerprint treatment of porous evidence. Using an Epson Stylus Photo R265 inkjet printer, ink cartridges were filled with alanine solutions of various concentrations, allowing different motifs to be printed onto copy paper and subsequently developed using DFO. Participants searched for this ‘evidence’ both with and without dark adapted vision. On average, participants were able to locate and correctly recognise 16% more evidence once dark adapted using the Crime-lite Eye?.The increase in evidence located by participants once dark adapted suggests that crime scene officers should be dark adapting in order to visualise as much as possible. The time taken to dark adapt, 10?min on average during this study, is not excessively long, and should not significantly slow the investigation.  相似文献   
19.
The objective was to investigate color change and surface damage in dental resin composites exposed to high temperatures over different time intervals for comparative purposes. Samples were prepared using two resins - Z100(R) (R1) and Charisma (R2), heated at the following temperatures: 200 degrees C, 400 degrees C, 600 degrees C, 1000 degrees C, for 15, 30 and 45 min (n = 104 for each resin sample). Color (DeltaE) and brightness (DeltaL) changes were analyzed by spectrophotometry using the CIE Lab system and surface changes by Scanning Electron Microscopy (SEM). R1 showed more intense color changes after heat exposure than R2. DeltaL values were found to be the best parameter for evaluation of light and color change. A biphasic pattern after thermal exposure was detected, from dark brown to light white. SEM showed more intense alterations in R2 than in R1. These results indicate that the parameters observed in both resins are useful as a guide in forensic analyses.  相似文献   
20.
Suspects in shooting investigations in Chicago are routinely transported in department vehicles and detained in department facilities prior to gunshot residue (GSR) evidence collection. The GSR test results are used to associate the suspect with primary exposure to GSR. The potential for these vehicles and facilities being sources of secondary GSR contamination needed to be determined. A total of 201 samples were collected from randomly selected vehicles and detention facilities. The sampling collected trace materials from surfaces that suspects' hands may contact during the arrest process. These samples were examined for the presence of GSR particles using scanning electron microscopy. Upon completion of the automated analysis, those particles that met an initial GSR screening criterion were relocated and reanalyzed. The locations where GSR particles were recovered allowed us to make recommendations to the Chicago Police Department with regard to transporting and detaining these suspects. The low number of GSR particles recovered suggests that the potential for secondary contamination, although present, is relatively low.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号