全文获取类型
收费全文 | 277篇 |
免费 | 33篇 |
专业分类
工人农民 | 1篇 |
法律 | 235篇 |
中国共产党 | 3篇 |
中国政治 | 21篇 |
政治理论 | 4篇 |
综合类 | 46篇 |
出版年
2024年 | 4篇 |
2023年 | 7篇 |
2022年 | 2篇 |
2021年 | 10篇 |
2020年 | 13篇 |
2019年 | 7篇 |
2018年 | 7篇 |
2017年 | 7篇 |
2016年 | 10篇 |
2015年 | 11篇 |
2014年 | 21篇 |
2013年 | 27篇 |
2012年 | 12篇 |
2011年 | 25篇 |
2010年 | 18篇 |
2009年 | 17篇 |
2008年 | 25篇 |
2007年 | 24篇 |
2006年 | 18篇 |
2005年 | 9篇 |
2004年 | 6篇 |
2003年 | 10篇 |
2002年 | 8篇 |
2001年 | 4篇 |
2000年 | 5篇 |
1999年 | 1篇 |
1996年 | 1篇 |
1985年 | 1篇 |
排序方式: 共有310条查询结果,搜索用时 0 毫秒
271.
Characterization and Differentiation of Geometric Isomers of 3‐methylfentanyl Analogs by Gas Chromatography/Mass Spectrometry,Liquid Chromatography/Mass Spectrometry,and Nuclear Magnetic Resonance Spectroscopy 下载免费PDF全文
Tatsuyuki Kanamori Ph.D. Yuko T. Iwata Ph.D. Hiroki Segawa Ph.D. Tadashi Yamamuro Ph.D. Kenji Kuwayama Ph.D. Kenji Tsujikawa Ph.D. Hiroyuki Inoue Ph.D. 《Journal of forensic sciences》2017,62(6):1472-1478
The cis and trans isomers of 3‐methylfentanyl and its three analogs were chemically synthesized, and these compounds were characterized and differentiated by gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), and nuclear magnetic resonance (NMR) spectroscopy. The cis and trans isomers of the 3‐methylfentanyl analogs were completely separated by GC/MS. Although the high temperature of the GC injection port caused thermal degradation of β‐hydroxy‐3‐methylfentanyl, the degradation was completely suppressed by trimethylsilyl derivatization. The isomers were also well separated by LC/MS on an octadecylsilyl column with 10 mM ammonium acetate and methanol as the mobile phase. The proton NMR signals were split when the hydrochloride salts of the 3‐methylfentanyl analogs were dissolved in deuterated chloroform because stereoisomers were formed by the coordination of the hydrochloride proton to the nitrogen of the piperidine ring of the 3‐methylfentanyl analogs. 相似文献
272.
Kimone M. Antoine B.S. Shirin Mortazavi Angela D. Miller M.S. Lisa M. Miller Ph.D. 《Journal of forensic sciences》2010,55(2):513-518
Abstract: The identification of aged latent fingerprints is often difficult, especially for those of children. To understand this phenomenon, the chemical composition of children’s versus adults’ latent fingerprints was examined over time using Fourier transform infrared microscopy. Hierarchical cluster analysis revealed that children’s and adults’ prints were distinguishable for up to 4 weeks after deposition, based on differences in sebum composition. Specifically, adults had a higher lipid content than children, but both decreased over time, attributable to the volatility of free fatty acids. The aliphatic CH3, aliphatic CH2, and carbonyl ester compositions changed differently in adults versus children over time, consistent with higher cholesterol and cholesteryl esters in children’s prints and wax esters and glycerides in adults’ prints. Thus, fingerprint composition changes with time differently in children versus adults, making it a sensitive metric to estimate the age of an individual, especially when the age of the print is known. 相似文献
273.
Lisa LaGoo M.S. Luther S. Schaeffer M.S. David W. Szymanski Ph.D. Ruth Waddell Smith Ph.D. 《Journal of forensic sciences》2010,55(3):624-632
Abstract: Blowfly larvae and porcine tissue contaminated with gunshot residue (GSR) were collected during summer and winter months, over a 37‐day and a 60‐day sampling period, respectively. Wound samples were microwave‐digested and analyzed by inductively coupled plasma mass spectrometry (ICP‐MS) for the detection of antimony, barium, and lead. During summer, the 37‐day sampling period encompassed all stages of decomposition, except skeletonization. The three elements were detected in larvae only on days 3 and 4 after death but were detected at significant levels in tissue samples throughout the entire sampling period. In winter, no significant decomposition was observed throughout the 60‐day sampling. Although temperatures were too low for blowfly activity, the three elements were detected in the tissue samples at relatively constant, significant levels. Hence, GSR determination in tissue was more dependent on decomposition stage rather than time since death. 相似文献
274.
Lisa Reid B.Sc. Kal Chana C.Chem. John W. Bond D.Phil. Matthew J. Almond Ph.D. Stuart Black Ph.D. 《Journal of forensic sciences》2010,55(3):753-756
Abstract: The collection efficiency of two widely used gunshot residue (GSR) collection techniques—carbon‐coated adhesive stubs and alcohol swabs—has been compared by counting the number of characteristic GSR particles collected from the firing hand of a shooter after firing one round. Samples were analyzed with both scanning electron microscopy and energy dispersive X‐rays by an experienced GSR analyst, and the number of particles on each sample containing Pb, Ba, and Sb counted. The adhesive stubs showed a greater collection efficiency as all 24 samples gave positive results for GSR particles whereas the swabs gave only positive results for half of the 24 samples. Results showed a statistically significant collection efficiency for the stub collection method and likely reasons for this are considered. 相似文献
275.
276.
Stephanie J. Notter B.Sc. ; Barbara H. Stuart Ph.D. ; Rebecca Rowe B.Sc. ; Neil Langlois M.D. 《Journal of forensic sciences》2009,54(1):195-201
Abstract: The early stages of adipocere formation in both pig and human adipose tissue in aqueous environments have been investigated. The aims were to determine the short-term changes occurring to fat deposits during decomposition and to ascertain the suitability of pigs as models for human decomposition. Subcutaneous adipose tissue from both species after immersion in distilled water for up to six months was compared using Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry and inductively coupled plasma-mass spectrometry. Changes associated with decomposition were observed, but no adipocere was formed during the initial month of decomposition for either tissue type. Early-stage adipocere formation in pig samples during later months was detected. The variable time courses for adipose tissue decomposition were attributed to differences in the distribution of total fatty acids between species. Variations in the amount of sodium, potassium, calcium, and magnesium were also detected between species. The study shows that differences in total fatty acid composition between species need to be considered when interpreting results from experimental decomposition studies using pigs as human body analogs. 相似文献
277.
Abstract: Automated scanning electron microscopy with energy dispersive spectroscopy has been used to analyze airbag residue particles. Analysis of airbag residue from some passenger side airbags revealed some residue particles which are consistent with gunshot residue (GSR) samples. The source of these particles was determined to be percussion primers used to initiate the chemical reaction for deployment. This article identifies some vehicles which contain this type of airbag and demonstrates the types of particles which could be misidentified as being GSR. The low numbers of GSR particles in among the large particle populations of zirconium and/or copper–cobalt particles, which are clearly airbag residue, allow the trained analysts to distinguish the correct source of this residue. Particles containing high aluminum levels, elevated levels of allowable elements in GSR particles, or the presence of elements that are rare in GSR particles stand out as indications that the particles are not GSR in origin. This study serves as a guide to analysts who perform particle analysis in forensic investigations. 相似文献
278.
Junko Fujihara Ph.D. Naoki Nishimoto Ph.D. Toshihiro Yasuda Ph.D. Haruo Takeshita M.D. Ph.D. 《Journal of forensic sciences》2019,64(3):698-701
In the present study, we used micro‐Raman spectroscopy with high‐resolution analysis to discriminate between bloodstains from infants and bloodstains from adults. Raman peaks were detected at 674, 754, 976, 1002, 1105, 1127, 1176, 1248, 1340, 1368, 1390, 1560, and 1611 cm?1; these peaks were derived from hemoglobin, albumin, and glucose. However, a peak was obtained at 1105 cm?1, which was assigned to histidine; this peak was observed only for bloodstains from adults. Human adult hemoglobin (HbA) is composed of an α2β2 tetramer structure, whereas human fetal hemoglobin (HbF) is composed of an α2γ2. Therefore, the lack of a Raman peak at 1105 cm?1 in bloodstains from infants indicates the possibility of two histidine substitutions (His116Ile and His143Ser) in the γ chain of HbF. This study discriminates between bloodstains from infants and bloodstains from adults using micro‐Raman spectroscopy, with beneficial implications in forensic science. 相似文献
279.
Authentication of Surveillance Videos: Detecting Frame Duplication Based on Residual Frame 下载免费PDF全文
Nowadays, surveillance systems are used to control crimes. Therefore, the authenticity of digital video increases the accuracy of deciding to admit the digital video as legal evidence or not. Inter‐frame duplication forgery is the most common type of video forgery methods. However, many existing methods have been proposed for detecting this type of forgery and these methods require high computational time and impractical. In this study, we propose an efficient inter‐frame duplication detection algorithm based on standard deviation of residual frames. Standard deviation of residual frame is applied to select some frames and ignore others, which represent a static scene. Then, the entropy of discrete cosine transform coefficients is calculated for each selected residual frame to represent its discriminating feature. Duplicated frames are then detected exactly using subsequence feature analysis. The experimental results demonstrated that the proposed method is effective to identify inter‐frame duplication forgery with localization and acceptable running time. 相似文献
280.
Source Determination of Red Gel Pen Inks using Raman Spectroscopy and Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy combined with Pearson's Product Moment Correlation Coefficients and Principal Component Analysis 下载免费PDF全文
Muhammad Naeim Mohamad Asri B.Sc. Wan Nur Syuhaila Mat Desa Ph.D. Dzulkiflee Ismail Ph.D. 《Journal of forensic sciences》2018,63(1):285-291
The potential combination of two nondestructive techniques, that is, Raman spectroscopy (RS) and attenuated total reflectance–fourier transform infrared (ATR‐FTIR) spectroscopy with Pearson's product moment correlation (PPMC) coefficient (r) and principal component analysis (PCA) to determine the actual source of red gel pen ink used to write a simulated threatening note, was examined. Eighteen (18) red gel pens purchased from Japan and Malaysia from November to December 2014 where one of the pens was used to write a simulated threatening note were analyzed using RS and ATR‐FTIR spectroscopy, respectively. The spectra of all the red gel pen inks including the ink deposited on the simulated threatening note gathered from the RS and ATR‐FTIR analyses were subjected to PPMC coefficient (r) calculation and principal component analysis (PCA). The coefficients r = 0.9985 and r = 0.9912 for pairwise combination of RS and ATR‐FTIR spectra respectively and similarities in terms of PC1 and PC2 scores of one of the inks to the ink deposited on the simulated threatening note substantiated the feasibility of combining RS and ATR‐FTIR spectroscopy with PPMC coefficient (r) and PCA for successful source determination of red gel pen inks. The development of pigment spectral library had allowed the ink deposited on the threatening note to be identified as XSL Poppy Red (CI Pigment Red 112). 相似文献