排序方式: 共有158条查询结果,搜索用时 15 毫秒
21.
22.
Stephan A. Bolliger M.D. ; Lars Oesterhelweg M.D. ; Danny Spendlove M.D. ; Steffen Ross M.D. ; Michael J. Thali M.D. 《Journal of forensic sciences》2009,54(5):1119-1122
Abstract: The radiological determination of foreign objects in corpses can be difficult if they are fragmented or deformed. With multislice computed tomography, radiodensities—referred to as Hounsfield units (HU)—can be measured. We examined the possibility of differentiating 21 frequently occurring foreign bodies, such as metals, rocks, and different manmade materials by virtue of their HU values. Gold, steel, and brass showed mean HU values of 30671–30710 (upper measurable limit), mean HU values for steel, silver, copper, and limestone were 20346, 16949, 14033, and 2765, respectively. The group consisting of objects, such as aluminum, tarmac, car front-window glass, and other rocks, displayed mean HU values of 2329–2131 HU. The mean HU value of bottle glass and car side-window glass was 2088, whereas windowpane glass was 493. HU value determination may therefore help in preautopsy differentiation between case-relevant and irrelevant foreign bodies and thus be useful for autopsy planning and extraction of the objects in question. 相似文献
23.
Dedouit F Guilbeau-Frugier C Capuani C Sévely A Joffre F Rougé D Rousseau H Telmon N 《Journal of forensic sciences》2008,53(6):1424-1429
A 17-month-old male infant died at home. The infant's right arm was immobilized because of a humeral fracture 1 month earlier. The circumstances of death appeared unclear to the police investigators and a medicolegal autopsy was carried out. External examination revealed diffuse ecchymoses of varying color. Postmortem imaging was performed prior to autopsy (X-rays, multislice computed tomography [MSCT], and focused brain magnetic resonance imaging [MRI]). These investigations revealed four rib fractures of varying ages, one of which was posterior. Cerebral and pericerebral traumatic lesions were also diagnosed: bilateral subdural hematomas, intraventricular, meningeal, and interpedoncular hemorrhages. In the abdomen, fresh blood was visible within the anterior abdominal wall and the mesenteric root. Autopsy and microscopic study confirmed these lesions. This case report illustrates the valuable assistance rendered by MSCT and MRI to diagnose abuse when a child has died in unclear circumstances. 相似文献
24.
It is important to understand the extent of transfer of explosive particles to different surfaces in order to better evaluate potential cross-contamination by explosives in crowded security controls such as those at airports. This work investigated the transfer of nine explosive residues (ANFO, dynamite, black powder, TNT, HMTD, PETN, NH4NO3, KNO3, NaClO3) through fingerprints from one surface to another. First, the extent of adhesion of explosive residues from different surfaces to the bare finger, nitrile and latex gloves was studied. Then, the transfer of explosive residues from one surface to another through fingerprints was investigated. Cotton fabric (hereinafter referred to as cotton) as clothing material and polycarbonate plastic (hereinafter referred to as polycarbonate) as luggage material were chosen for the experiments. These surfaces containing explosive particles were imaged using a reflex camera before and after the particles were transferred. Afterwards the images were processed in MATLAB where pixels corresponding to explosive residues were quantified. Results demonstrated that transfer of explosive residues frequently occurred with certain differences among materials. Generally, the amount of explosive particles adhered to the finger decreased in the following order: skin>latex>nitrile, while the transfer of particles from the finger to another surface was the opposite. The adhesion of explosive residues from polycarbonate to the finger was found to be better compared to cotton, while the amount of particles transferred to cotton was higher. 相似文献
25.
Effect of Aging and Surface Interactions on the Diffusion of Endogenous Compounds in Latent Fingerprints Studied by Mass Spectrometry Imaging, 下载免费PDF全文
The ability to determine the age of fingerprints would be immeasurably beneficial in criminal investigations. We explore the possibility of determining the age of fingerprints by analyzing various compounds as they diffuse from the ridges to the valleys of fingerprints using matrix‐assisted laser desorption/ionization mass spectrometry imaging. The diffusion of two classes of endogenous fingerprint compounds, fatty acids and triacylglycerols (TGs), was studied in fresh and aged fingerprints on four surfaces. We expected higher molecular weight TGs would diffuse slower than fatty acids and allow us to determine the age of older fingerprints. However, we found interactions between endogenous compounds and the surface have a much stronger impact on diffusion than molecular weight. For example, diffusion of TGs is faster on hydrophilic plain glass or partially hydrophilic stainless steel surfaces, than on a hydrophobic Rain‐x treated surface. This result further complicates utilizing a diffusion model to age fingerprints. 相似文献
26.
The application of infrared chemical imaging to the analysis of bicomponent fibers was evaluated. Eleven nominally bicomponent fibers were examined either side-on or in cross-section. In six of the 11 samples, infrared chemical imaging was able to spatially resolve two spectroscopically distinct regions when the fibers were examined side-on. As well as yielding characteristic infrared spectra of each component, the technique also provided images that clearly illustrated the side-by-side configuration of these components in the fiber. In one case it was possible to prepare and image a cross-section of the fiber, but in general the preparation of fiber cross-sections proved very difficult. In five of the 11 samples, the infrared spectra could be used to identify the overall chemical composition of the fibers, according to a published classification scheme, but the fiber components could not be spatially resolved. Difficulties that are inherent to conventional "single-point" infrared spectroscopy, such as interference fringing and sloping baselines, particularly when analyzing acrylic type fibers, were also encountered in the infrared chemical image analysis of bicomponent fibers. A number of infrared sampling techniques were investigated to overcome these problems, and recommendations for the best sampling technique are given. Chemical imaging results were compared with those obtained using conventional fiber microscopy techniques. 相似文献
27.
Plunkett J 《Journal of forensic sciences》2006,51(1):127-130
Minor soft tissues injuries are common in both adults and children who have had cardiopulmonary resuscitation (CPR). Potentially life-threatening injuries are rare. The pre-arrest history in a resuscitated adult often assists the pathologist to interpret autopsy findings. In contrast, an infant or child may not have a reliable history. In this situation, it may be difficult if not impossible to distinguish resuscitation injuries from pre-existing accidental or inflicted trauma. I describe two children who had significant autopsy-documented injuries initially attributed to abuse. The State filed murder charges against the caretaker in each case. However, further history and review of the medical records suggested that resuscitation rather than pre-arrest trauma caused almost all of the injuries. The State dismissed the charges in the first case. A jury returned a "not guilty" verdict in the second. It is essential to consider the entire history and not just autopsy findings when performing a death investigation. 相似文献
28.
赵伟 《广西警官高等专科学校学报》2001,14(2):34-36
随着计算机应用软件多种类的开发 ,利用计算机来处理图像已成现实。计算机图像处理技术(也称数字图像处理技术)相对于传统的暗房技术 ,不但具备传统暗房技术制作影像的所有的技巧 ,而且还有许多传统暗房技术不可比拟的优势。数字图像处理技术是摄影艺术再创造的技术 ,可制作完美无暇的照片 ,照片质量比传统暗房技术制作的质量更高,对环境无污染 ,出片速度快、省时、省财、省力、省地方。数字图像处理技术必将取代传统的暗房技术 相似文献
29.
Dominic Gascho R.T. Mária Marosi R.T. Michael J. Thali M.D. Eva Deininger-Czermak M.D. 《Journal of forensic sciences》2020,65(4):1360-1364
Postmortem magnetic resonance imaging (MRI) is rarely used for the radiologic assessment of gunshot injuries, although it has clear advantages over postmortem computed tomography (CT) with regard to the imaging of soft tissue injuries. Another benefit in using MRI is that lodged projectiles composed of nonferromagnetic material such as lead present only marginal metal artifacts compared with severe artifacts on CT. This case report presents CT and MRI findings in a case with two gunshot wounds to the neck: a perforating wound and a nonperforating wound with a lead bullet lodged in the cervical spine. The decedent underwent CT and MRI before the scheduled autopsy. A ring of radiopaque material under the dermis in the fatty tissue was identified at both entrance wounds on CT, which was indicative of contact shots. The perforating gunshot was clearly indicated on CT by bullet fragments along the wound channel through the perforated 6th cervical vertebra and the fractured cricoid cartilage at the exit wound. The second trajectory, however, was only assumed based on the presence of gunshot residues at the entrance wound and the position of the lodged bullet. The radiologic assessment was severely impeded by the metal artifacts on CT. Barely noticeable metal artifacts on MRI allowed for clear visualization of the soft tissue injuries and the ruptured medulla oblongata. Only MRI clarified the soft tissue injuries of the brainstem noninvasively, which could provide specific and graphic information on the rapidity of death and the incapacitation of the victim. 相似文献
30.
Ayşegül Erdoğan Ph.D. Meral Esen Ph.D. Robin Simpson Ph.D. 《Journal of forensic sciences》2020,65(5):1730-1735
X-ray photoelectron spectroscopy (XPS) is a widely used technique to characterize the surface chemistry of materials. It plays a crucial role in accessing qualitative and quantitative information and in detecting the presence of chemical functional groups on the surface of any material. The forensic methods available to detect and identify elements and organic/inorganic compounds are often destructive, so evidence cannot be re-analyzed. However, XPS allows rapid analysis of samples without damaging them. Recently, an increasing number of forensic researchers have begun to study certain chemical information on fingermarks. In this study, the authors aimed to present the applicability and power of XPS imaging in fingermark analysis which can also provide specific information about the fingermark chemical composition. Herein, monochromated X-ray (Al Kα) spot size was fixed at 50 μm. XPS mapping resulted in the acquisition of spectra at each pixel, in an array of 41 × 30 pixels with a step size of 50 μm. Then, a simple discussion has been made about how the scanned surface spectrum and basic snapshot spectra are used to identify different components at a fingertip of a scanned surface area (~3 mm2). Hence, a fingermark pattern contaminated with caffeine, TiO2, and Pb/PbO deposited on the silicon wafer can be chemically mapped and visualized by XPS using principal component analysis (PCA). Thus, the present study showed the possible applicability of XPS for the identification of illicit drugs of abuse, gunshot residue, and skin care products on latent fingermark by mimicking a crime scene evidence. 相似文献