首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   181篇
  免费   42篇
法律   198篇
中国政治   4篇
政治理论   1篇
综合类   20篇
  2024年   2篇
  2023年   10篇
  2022年   6篇
  2021年   10篇
  2020年   15篇
  2019年   11篇
  2018年   10篇
  2017年   11篇
  2016年   11篇
  2015年   7篇
  2014年   14篇
  2013年   14篇
  2012年   9篇
  2011年   15篇
  2010年   18篇
  2009年   9篇
  2008年   13篇
  2007年   10篇
  2006年   13篇
  2004年   2篇
  2003年   3篇
  2002年   1篇
  2001年   5篇
  1985年   1篇
  1984年   1篇
  1983年   2篇
排序方式: 共有223条查询结果,搜索用时 15 毫秒
11.
Latent fingerprint deposits on thermal paper sourced from the U.S., China, the U.K., and Australia have been visualized by heating. U.S. and Chinese sourced paper produced two distinct types of fingerprint development. In one type (type 1), the paper dye colors where the deposit is present (as previously reported) and in the other type (type 2) the ‘inverse’ of this gives paper coloring only in areas not coincident with the deposit. Both development types gave identifiable fingerprints, the majority fading within 24 h of heating. Fingerprint development from U.K. and Australian sourced paper was exclusively type 1 and resistant to fading. Temperatures for fingerprint visualization were higher for U.S. paper (64–71°C) and Chinese paper (75–95°C) than for U.K. and Australian sourced paper (43–50°C). Particularly for Chinese sourced paper, these temperatures were within a few degrees of the normal paper color temperature. A mechanism for type 2 fingerprint development is proposed.  相似文献   
12.
Using micro-X-ray fluorescence (MXRF), a novel means of detecting fingerprints was examined in which the prints were imaged based on their elemental composition. MXRF is a nondestructive technique. Although this method requires a priori knowledge about the approximate location of a print, it offers a new and complementary means for detecting fingerprints that are also left pristine for further analysis (including potential DNA extraction) or archiving purposes. Sebaceous fingerprints and those made after perspiring were detected based on elements such as potassium and chlorine present in the print residue. Unique prints were also detected including those containing lotion, saliva, banana, or sunscreen. This proof-of-concept study demonstrates the potential for visualizing fingerprints by MXRF on surfaces that can be problematic using current methods.  相似文献   
13.
Forensic analysis of bicomponent fibers using infrared chemical imaging   总被引:2,自引:0,他引:2  
The application of infrared chemical imaging to the analysis of bicomponent fibers was evaluated. Eleven nominally bicomponent fibers were examined either side-on or in cross-section. In six of the 11 samples, infrared chemical imaging was able to spatially resolve two spectroscopically distinct regions when the fibers were examined side-on. As well as yielding characteristic infrared spectra of each component, the technique also provided images that clearly illustrated the side-by-side configuration of these components in the fiber. In one case it was possible to prepare and image a cross-section of the fiber, but in general the preparation of fiber cross-sections proved very difficult. In five of the 11 samples, the infrared spectra could be used to identify the overall chemical composition of the fibers, according to a published classification scheme, but the fiber components could not be spatially resolved. Difficulties that are inherent to conventional "single-point" infrared spectroscopy, such as interference fringing and sloping baselines, particularly when analyzing acrylic type fibers, were also encountered in the infrared chemical image analysis of bicomponent fibers. A number of infrared sampling techniques were investigated to overcome these problems, and recommendations for the best sampling technique are given. Chemical imaging results were compared with those obtained using conventional fiber microscopy techniques.  相似文献   
14.
A new method for thermal desorption of small samples is presented. The method uses a solid phase microextraction (SPME) holder with the fiber removed. The sample-for example, an ink sample on paper-is simply placed inside the needle of the holder, where normally an SPME fiber is positioned. The thermal desorption is then performed on any kind of gas chromatograph in a manner similar to that for SPME analysis. The needle of the SPME holder penetrates the injector septum; the temperature of the thermal desorption is simply the temperature of the injector. No solvents or liquid nitrogen cooling are used. The paper sample is kept inside the holder needle during the analysis. After the analysis is completed, the sample is removed from the needle by pushing forward the steel wire inside the needle in the way normally used to perform sampling with the SPME fiber. The desorbed compounds were analyzed by gas chromatography with a flame ionization detector or by gas chromatography-mass spectrometry. The optimum temperature for desorption of ink samples on paper was 200 degrees C. The influence of the paper matrix is negligible at that temperature. Laboratories lacking the commercial device for thermal desorption can use this cheap device for the analysis of, for example, writing ink, printing ink, and inkjet ink samples on paper. Other types of samples can be investigated but the size of samples suitable for analysis is limited.  相似文献   
15.
Postmortem investigation is increasingly supported by computed tomography (CT) and magnetic resonance imaging, in which postmortem minimal invasive angiography has become important. The newly introduced approach using an aqueous contrast agent solution provided excellent vessel visualization but was suspected to possibly cause tissue edema artifacts in histological investigations. The aim of this study was to investigate on a porcine heart model whether it is possible to influence the contrast agent distribution within the soft tissue by changing its viscosity by dissolving the contrast agent in polyethylene glycol (PEG) as a matrix medium. High-resolution CT scans after injection showed that viscosities above c. 15 mPa s (65% PEG) prevented a contrast agent distribution within the capillary bed of the left ventricular myocardium. Thereby, the precondition of edema artifacts could be reduced. Its minimal invasive application on human corpses needs to be further adapted as the flow resistance is expected to differ between different tissues.  相似文献   
16.
Manual ground searches and cadaver dogs are traditional methods for locating remains, but they can be time- and resource-intensive, resulting in the decomposition of bodies and delay in victim identification. Therefore, thermal imaging has been proposed as a potentially useful tool for detecting remains based on their temperature. This study investigated the potential of a novel search technique of thermal drones to detect surface remains through the detection of maggot mass temperatures. Two trials were carried out at Selangor, Malaysia, each utilizing 12 healthy male Oryctolagus cuniculus European white rabbits and DJI Matrice 300 RTK drone China, equipped with a thermal camera; Zenmuse H20T to record the thermal imaging footage of the carcasses at various heights (15, 30, 60–100 m) for 14 days for each trial. Our results demonstrated that the larval masses and corresponding heat emissions were at their largest during the active decay stage; therefore, all the carcasses were observable in thermal images on day 5 and remained until day 7. Statistical analyses showed that (1) no statistically significant differences in thermal images between clothed and unclothed subjects (p > 0.05); (2) 15 m above ground level was proven to be the optimal height, as it showed the greatest contrast between the carcass heat signature and the background (p < 0.005). Our data suggested the potential window of detection of thermal signatures was detectable up to 7 days post-deposition. This could be an important guideline for the search and recovery teams for operational implementation in this tropical region.  相似文献   
17.
目的 利用放射性核素骨显像检查鉴别鼻部骨折的新旧程度.方法 对48例疑似陈旧性鼻部骨折伤者放射性核素全身骨显像、局部断层骨显像及CT融合图像在鼻部骨折处放射性分布、浓聚情况的分析,鉴别鼻部骨折的新旧程度.结果 48例中8例放射性核素全身骨显像、局部断层骨显像及CT融合图像在鼻部骨折处显示放射性分布增高、浓聚区,诊为新鲜骨折,评定为轻伤;40例在鼻部骨折处未见明显异常放射性分布增高、浓聚区,诊为陈旧骨折,与本次外伤无因果关系.结论 放射性核素骨显像检查在鉴别鼻部骨折新旧程度方面可得到满意结果.  相似文献   
18.
19.
《Science & justice》2022,62(4):433-447
The forensic scenario, on which the round robin study was based, simulated a suspected intentional manipulation of a real estate rental agreement consisting of a total of three pages. The aims of this study were to (i) establish the amount and reliability of information extractable from a single type of evidence and to (ii) provide suggestions on the most suitable combination of compatible techniques for a multi-modal imaging approach to forgery detection. To address these aims, seventeen laboratories from sixteen countries were invited to answer the following tasks questions: (i) which printing technique was used? (ii) were the three pages printed with the same printer? (iii) were the three pages made from the same paper? (iv) were the three pages originally stapled? (v) were the headings and signatures written with the same ink? and (vi) were headings and signatures of the same age on all pages? The methods used were classified into the following categories: Optical spectroscopy, including multispectral imaging, smartphone mapping, UV-luminescence and LIBS; Infrared spectroscopy, including Raman and FTIR (micro-)spectroscopy; X-ray spectroscopy, including SEM-EDX, PIXE and XPS; Mass spectrometry, including ICPMS, SIMS, MALDI and LDIMS; Electrostatic imaging, as well as non-imaging methods, such as non-multimodal visual inspection, (micro-)spectroscopy, physical testing and thin layer chromatography. The performance of the techniques was evaluated as the proportion of discriminated sample pairs to all possible sample pairs. For the undiscriminated sample pairs, a distinction was made between undecidability and false positive claims. It was found that none of the methods used were able to solve all tasks completely and/or correctly and that certain methods were a priori judged unsuitable by the laboratories for some tasks. Correct results were generally achieved for the discrimination of printer toners, whereas incorrect results in the discrimination of inks. For the discrimination of paper, solid state analytical methods proved to be superior to mass spectrometric methods. None of the participating laboratories deemed addressing ink age feasible. It was concluded that correct forensic statements can only be achieved by the complementary application of different methods and that the classical approach of round robin studies to send standardised subsamples to the participants is not feasible for a true multimodal approach if the techniques are not available at one location.  相似文献   
20.
One of the crucial factors determining the cyanoacrylate deposit quality over latent fingerprints appeared to be the extent of the humidity. This work focuses on the enhancement/refreshment of age‐degraded latent fingerprints by irradiating the samples with UV, X‐ray, or thermal neutrons prior to the cyanoacrylate (CA) fuming. Age degradation of latent fingerprints deposited on glass surfaces was examined through the decrease in the number of characteristic minutiae counts over time. A term “critical day” was introduced for the time at which the average number of identifiable minutiae definitions drops to one‐half. Fingerprints older than their “critical day” were exposed to either UV, X‐ray, or thermal neutrons. Identical reference samples were kept unexposed. All samples, both reference and irradiated, were developed during a single CA fuming procedure. Comparative latent fingerprint analysis showed that exposure to ionizing radiation enhances the CA fuming, yielding a 20‐30% increase in average minutiae count.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号