首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
法律   4篇
  2009年   1篇
  2008年   1篇
  2000年   1篇
  1986年   1篇
排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
2.
Abstract: Conducted energy weapons (such as the Advanced TASER X26 model produced by TASER International), incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, a “Modifiable Electronic Stimulator” was used to evaluate the effects of changing various parameters of the stimulating pulse. Muscle contraction was affected by pulse power, net/gross charge, pulse duration, and pulse repetition frequency. The contraction force increased linearly as each of these factors was increased. Elimination of a precursor pulse from X26‐like pulses did not have a significant effect on the normalized force measured. Muscle‐contraction force increased as the spacing increased from 5 to 20 cm, with no further change in force above 20 cm of spacing. Therefore, it is suggested that any future developments of new conducted energy weapons should include placement of electrodes a minimum of 20 cm apart so that efficiency of the system is not degraded. In the current study, the 50% probability of fibrillation level of X26‐like pulses ranged from 4 to 5 times higher than the X26 itself. Relatively large variations about the X26 operating level were found not to result in fibrillation or asystole. Therefore, it should be possible to design and build an X26‐type device that operates efficiently at levels higher than the X26.  相似文献   
3.
In a previous study, 18 repeated exposures of anaesthetized swine to an electro-muscular incapacitating device (TASER International's ADVANCED TASER X26 electronic control device) resulted in acidosis and increases in blood electrolytes. In the current study, experiments were performed to investigate effects of a more typical scenario of repeated exposures of the device on muscle contraction and changes in blood factors. Ten swine were exposed for 5s, followed by a 5-s period of no exposure, three times. Selected blood factors were monitored for 3h following exposure. Transient increases in blood glucose, lactate, sodium, potassium, calcium, and pCO(2) were consistent with previous reports in the literature dealing with studies of muscle stimulation or exercise. Blood pH was decreased immediately following exposure, but subsequently returned toward a normal level. Oxygen saturation (measured by pulse oximetry) was not changed significantly. In conclusion, three repeated TASER device exposures had only transient effects on blood factors, which all returned to pre-exposure levels, with the exception of hematocrit (which remained elevated after 3h). Since the increase in this factor was less than that which may occur after short periods of exercise, it is unlikely that this would be an indicator of any serious harm.  相似文献   
4.
This paper studies the problem of how the legal system regulatesactivity outside the courtroom based on information suppliedin court by interested and potentially dishonest parties. Thesupply of information is analyzed along a game-theoretic dimension:the extent to which the supplier has an interest in how theinformation will be used. Such analysis uncovers a basic trade-offin system design between the 'fixed costs' of hearings (e.g.,the productive activity forsaken by participation) and the costof the evidence produced therein. This trade-off helps to explainand connect several trends in the historical evolution of Englishcivil process.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号