首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   1篇
各国政治   1篇
法律   20篇
政治理论   1篇
  2023年   1篇
  2017年   1篇
  2012年   1篇
  2011年   1篇
  2009年   1篇
  2008年   3篇
  2007年   3篇
  2005年   5篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  2000年   1篇
  1997年   1篇
  1996年   1篇
排序方式: 共有22条查询结果,搜索用时 15 毫秒
1.
In analyzing the data from a structured interview survey with Japanese litigants of civil trials, we examined the relationships between their perceptions of outcomes and process of the trials, responses to the trials, and evaluation of the judicial system. The results showed that both favorability of trial outcomes and procedural fairness of trials increased satisfaction with the trial outcomes and evaluation of the judicial system. Satisfaction was largely determined by perceived favorability, while the evaluation of the judicial system was largely determined by perceived procedural fairness, suggesting a justice bond effect that justice fortifies people's societal commitment. Consistent with procedural justice theories, the perception of procedural fairness was increased by the sense of control and the appraisal of relational factors, though both were affected by favorability.  相似文献   
2.
This system consists of a 3-D physiognomic range finder and a computer-assisted facial image superimposition unit. The 3-D range finder is composed of a detector for measuring facial surface and its control computer. The detector has two sinusoidal grating projection devices and two CCD cameras. The computer-assisted facial image superimposition unit consists of a host computer including a proprietary software, a flat surface color display and a color image scanner for inputting 2-D facial images of a criminal. The 3-D facial shape and texture of a suspect is obtained by using the range finder. To make the comparison between the 3-D facial image and the 2-D facial image, the 3-D facial image is first reproduced on a display of the host computer from a MO disk and then the 2-D facial image is taken with the color image scanner and reproduced on the display. The 3-D facial image is exactly adjusted to match the orientation and size of the 2-D facial image under the fine framework mode, and then the fine framework mode of 3-D facial image is converted to the fine texture image. The shape and positional relationships of facial components between the 3-D and 2-D facial images are examined by the fade-out or wipe image mode. The distance between the selected two points and angle among the selected three points on the 3-D and 2-D facial images are automatically measured for the assessment of anthropometrical data between both images. For evaluating the fit between the anthropometrical points on the 3-D and 2-D facial images, the reciprocal point-to-point difference between both images is compared.  相似文献   
3.
A new retrieval system for a 3D facial image database was designed and its reliability was experimentally examined. This system has two steps, firstly to automatically adjust the orientation of all 3D facial images in a database to that of the 2D facial image of a target person, and then to identify the facial image of the target person from the adjusted 3D facial images in the database using a graph-matching method. From the experimental study [M. Yoshino, K. Imaizumi, T. Tanijiri, J.G. Clement, Automatic adjustment of facial orientation in 3D face image database, Jpn. J. Sci. Tech. Iden. 8 (2003) 41-47], it is concluded that the software developed for the first step will be applicable to the automatic adjustment of facial orientation in the 3D facial image database. In 28 out of 110 sets (25.5%), the 3D image of the target person was chosen as the best match (from a database of 132 3D facial images) according to the similarity of the facial image characteristics based on the graph matching. The 3D facial image of the target person was ranked in the top of 10 of the database in 75 out of 110 sets (68.2%). These results suggest that this system is inadequate for the identification level, but may be feasible for screening method in a small database. It will be necessary to further pursue the possibility of realization of a facial image retrieval system for a large database such as suspects' facial images in future.  相似文献   
4.
Competitive PCR assays were established for the mitochondrial DNA hypervariable region I and the human amelogenin locus. Using these assays, the copy numbers of DNA participating in PCR (amplifiable DNA) were quantified in tissues exposed to different environments. Human ribs, skin and nails were left in three exposure conditions (in the open air, in soil and in water). The amounts of amplifiable DNA in these tissues were quantified during a time period of up to two months. The amount of amplifiable DNA was well preserved in hard tissues (ribs and nails) regardless of the exposure conditions, whereas the soft tissues immersed in water showed a rapid decrease in amplifiable DNA. Strong PCR inhibition was observed in the DNA extracts obtained from buried bones. This phenomenon was clearly identified from an amplification failure of the internal standards in the competitive PCR. A preliminary examination to identify the PCR inhibitor suggested that the soil itself contributed to the inhibition. In addition, the amounts of amplifiable DNA in case samples were also investigated.  相似文献   
5.
Bone samples are used for analysis of drugs in decomposed or skeletonized bodies. Toxicological analyses of buried bones are important for determining the causes and circumstances of death. In this study, methamphetamine and amphetamine concentrations in heart blood, thigh muscles, and thighbones were analyzed using solid‐phase extraction with liquid chromatography–tandem mass spectrometry. Methamphetamine concentrations in heart blood, thigh muscle, and thighbone ranged from 0.041 to 0.873 μg/mL, 0.649 to 2.623 μg/g, and 56.543 to 643.371 μg/g, respectively. Thighbone concentrations were significantly higher than those in heart blood or thigh muscles were. Methamphetamine concentrations in buried thighbone (4.010–45.785 μg/g) were significantly lower than those of unburied thighbones were (56.543–643.371 μg/g). Methamphetamine and amphetamine were detected in thighbones buried for 7–180 days. These findings indicate that the methamphetamine concentrations in bone are higher and decrease after burial in soil.  相似文献   
6.
When mitochondrial DNA (mtDNA) heteroplasmies are detected, they often confound forensic identification, especially if they are the result of poor biological sampling. In this study, we determined the ratio of heteroplasmy in samples that were amplified from a very small amount of template mtDNA or a few cells using a highly sensitive nested polymerase chain reaction (PCR) procedure and a direct sequencing analysis. As a result, more than half of the detected sequences (i.e., 17/20, 15/20, and 14/20) showed homoplasmy derived from a variation in the heteroplasmy proportion when only 10 copies of template mtDNA samples were amplified and analyzed. Additionally, with products amplified from one or several white blood cells (WBCs), several previously undetected heteroplasmies were detected. These results indicate the risks associated with using highly sensitive mtDNA techniques in forensic investigations because of the variable proportions of heteroplasmy or nucleotide substitutions that can possibly be detected from a very small biological sample.  相似文献   
7.
8.
We analyzed four children with increased density of the tentorium on postmortem computed tomographic (CT) scans that suggested traumatic subarachnoid hemorrhage; but in which followup autopsy demonstrated an absence of subarachnoid hemorrhage. All cases had neither head injuries nor distinct intracranial abnormalities. Histological examinations showed extensive hemorrhage within the tentorium. These findings indicate that increased density of the tentorium on postmortem CT scan reflects 'dural hemorrhage' that may occur in children without intracranial abnormalities. Pediatricians and forensic pathologists should be aware of this phenomenon when using postmortem preautopsy CT scanning for diagnosis of child abuse.  相似文献   
9.
Computer-assisted skull identification system using video superimposition   总被引:1,自引:0,他引:1  
This system consists of two main units, namely a video superimposition system and a computer-assisted skull identification system. The video superimposition system is comprised of the following five parts: a skull-positioning box having a monochrome CCD camera, a photo-stand having a color CCD camera, a video image mixing device, a TV monitor and a videotape recorder. The computer-assisted skull identification system is composed of a host computer including our original application software, a film recorder and a color printer. After the determination of the orientation and size of the skull to those of the facial photograph using the video superimposition system, the skull and facial photograph images are digitized and stored within the computer, and then both digitized images are superimposed on the monitor. For the assessment of anatomical consistency between the digitized skull and face, the distance between the landmarks and the thickness of soft tissue of the anthropometrical points are semi-automatically measured on the monitor. The wipe images facilitates the comparison of positional relationships between the digitized skull and face. The software includes the polynomial functions and Fourier harmonic analysis for evaluating the match of the outline such as the forehead and mandibular line in both the digitized images.  相似文献   
10.
An 11-month-old female infant died at home after being diagnosed as having gastroenteritis. Autopsy examination revealed a distended distal ileum filled with a large amount of watery contents, and a 3 cm x 3 cm x 4 cm cyst at the ileocecal part of the cecum that was histologically consistent with a duplication cyst. The cause of death was determined to be acute dehydration due to intestinal obstruction caused by a duplication cyst. This case indicates that intestinal obstruction by a duplication cyst should be recognized as a cause of unexpected death in infants.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号