首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   80篇
  免费   15篇
世界政治   1篇
外交国际关系   4篇
法律   67篇
中国政治   10篇
政治理论   4篇
综合类   9篇
  2023年   4篇
  2022年   1篇
  2020年   10篇
  2019年   4篇
  2018年   3篇
  2017年   5篇
  2016年   4篇
  2015年   6篇
  2014年   7篇
  2013年   8篇
  2012年   4篇
  2011年   6篇
  2010年   4篇
  2009年   9篇
  2008年   5篇
  2007年   3篇
  2006年   3篇
  2005年   2篇
  2004年   1篇
  2002年   2篇
  2001年   1篇
  2000年   2篇
  1999年   1篇
排序方式: 共有95条查询结果,搜索用时 15 毫秒
1.
Trigger pull is the force that needs to be exerted on the trigger to discharge a firearm. The measurement of trigger pull can assist in the evaluation of the safety, function, and manufacturing characteristics associated with a firearm during the forensic firearm examination process. Nonetheless, the accuracy and uncertainty of trigger pull measurements may be affected by the measuring device, test procedure, and environmental conditions. In this work, an innovative finger-trigger interface device was developed to facilitate accurate trigger pull measurements. The idea was to reduce the variation related to the position of the measurement device on the trigger in existing measuring methods and devices. Three force sensors based on different technologies were initially evaluated. While two of the three sensors failed to produce data, the miniature capacitive plate sensor exhibited high precision and a linear response over the range of typical trigger pulls. To examine the effects of the finger-trigger interface on trigger pull measurement, different sensor housing prototypes were designed in silico and 3D printed for the construction of three finger-trigger interface devices. The performance of each finger-trigger interface device was evaluated by measuring the trigger pulls of several selected firearms and comparing the data to a previously published study. Our preliminary results demonstrated the novel finger-trigger interface device offered a new way to measure trigger pull in situ with acceptable accuracy and precision.  相似文献   
2.
In this study, the nondestructive differentiation of individual white polyester clothing fibers was accomplished via synchrotron radiation microbeam X-ray fluorescence (SR-μ-XRF) analysis. SR-μ-XRF with vertical focusing is a useful nondestructive method for the analysis of a single polyester clothing fiber. Kirkpatrick–Baez (KB) mirror was used to vertically focus 20 keV X-rays for the analysis of 22 individual white polyester fibers taken from clothing commonly sold in Japan. SR-μ-XRF with a vertical focused 2 μm (V) × 300 μm (H) beam was approximately 12.8 times more sensitive than SR-XRF with an unfocused 300 μm (V) × 300 μm (H) beam for the detection of elements in single fibers. The minimum detection limits (MDLs) of the SR-μ-XRF method were 8.15 ppm for Cl and 0.06 ppm for Br. In addition to Ti in TiO2 delustering agents, Zr and Nb impurities in the delustering agents were detected in individual fibers. Sb from a polymerization catalyst and Co from a transesterification catalyst were also detected in individual fibers. Comparing the Ti Kβ/Sb Lα,β and Zr Kα/Nb Kα X-ray intensity ratios was a useful way to distinguish individual clothing fibers, and 98% of the fibers were differentiated when additional trace elements were used as discrimination indicators.  相似文献   
3.
新型红外线金属网式燃气灶具可使燃气趋于完全燃烧,提高热效率,达到保护环境的目的。文中重点介绍了灶具的结构,并分析其节能原理。  相似文献   
4.
现代生活中,平板玻璃越来越多地被应用到建筑物中,在刑事案件中经常能够提取到经犯罪分子破坏的玻璃碎块,所以对玻璃碎裂痕迹的研究对于侦查破案具有极其重要的意义。文中以平板玻璃坠落后的裂纹痕迹作为研究对象,通过制作实验样本,对裂纹的形成过程、形成原因以及物理模型进行分析研究,得出平板玻璃落地后裂纹中放射纹上的弓形纹向上汇聚、切向裂纹上的弓形纹向下汇聚,放射纹作用点分布位置在离地面较高一侧。  相似文献   
5.
Banknote evidence is often submitted after a suspect has attempted to disguise or remove red dye stain that has been released because of an anti-theft device that activates after banknotes have been unlawfully removed from bank premises. Three chlorinated compounds have been synthesized as forensic chemical standards to indicate bank security dye bleaching as a suspect's intentional method for masking a robbery involving dye pack release on banknotes. A novel, facile synthetic method to provide three chlorinated derivatives of 1-(methylamino)anthraquinone (MAAQ) is presented. The synthetic route involved Ultra Clorox bleach as the chlorine source, iron chloride as the catalyst, and MAAQ as the starting material and resulted in a three-component product mixture. Two mono-chlorinated isomers (2-chloro-1-(methylamino)anthraquinone and 4-chloro-1-(methylamino)anthraquinone) and one di-chlorinated compound (2,4-dichloro-1-(methylamino)anthraquinone) of the MAAQ parent molecule were detected by gas chromatography mass spectrometry (GC-MS), and subsequently isolated by liquid chromatography (LC) with postcolumn fraction collection. Although GC-MS is sensitive enough to detect all of the chlorinated products, it is not definitive enough to identify the structural isomers. Liquid-state nuclear magnetic resonance (NMR) spectroscopy was utilized to elucidate structurally the ortho- and para-mono-chlorinated isomers once enough material was properly isolated. A reaction mechanism involving iron is proposed to explain the presence of chlorinated MAAQ species on stolen banknotes after attempted bleaching.  相似文献   
6.
《Digital Investigation》2014,11(3):175-178
A number of new entertainment systems have appeared on the market that have embedded computing capabilities. Smart Televisions have the ability to connect to networks, browse the web, purchase applications and play games. Early versions were based on proprietary operating systems; newer versions released from 2012 are based on existing operating systems such as Linux and Android. The question arises as to what sort of challenges and opportunities they present to the forensics examiner. Are these new platforms or simply new varieties of existing forms of devices? What data do they retain and how easy is it to access this data? This paper explores this as a future forensic need and asks if we are missing potential sources of forensic data and to what degree we are ready to process these systems as part of an investigation.  相似文献   
7.
Small scale digital device forensics is particularly critical as a result of the mobility of these devices, leading to closer proximity to crimes as they occur when compared to computers. The Windows Surface tablet is one such device, combining tablet mobility with familiar Microsoft Windows productivity tools. This research considers the acquisition and forensic analysis of the Windows Surface RT tablet. We discuss the artifacts of both the Windows RT operating system and third-party applications. The contribution of this research is to provide a road map for the digital forensic examination of Windows Surface RT tablets.  相似文献   
8.
While canines are most commonly trained to detect traditional explosives, such as nitroaromatics and smokeless powders, homemade explosives (HMEs), such as fuel–oxidizer mixtures, are arguably a greater threat. As such, it is imperative that canines are sufficiently trained in the detection of such HMEs. The training aid delivery device (TADD) is a primary containment device that has been used to house HMEs and HME components for canine detection training purposes. This research assesses the odor release from HME components, ammonium nitrate (AN), urea nitrate (UN), and potassium chlorate (PC), housed in TADDs. Canine odor recognition tests (ORTs) were used with analytical data to determine the detectability of TADDs containing AN, UN, or PC. Headspace analysis by gas chromatography/mass spectrometry (GC/MS) with solid-phase microextraction (SPME) or online cryotrapping were used to measure ammonia or chlorine, as well as other unwanted odorants, emanating from bulk AN, UN, and PC in TADDs over 28 weeks. The analytical data showed variation in the amount of ammonia and chlorine over time, with ammonia from AN and UN decreasing slowly over time and the abundance of chlorine from PC TADDs dependent on the frequency of exposure to ambient air. Even with these variations in odor abundance, canines previously trained to detect bulk explosive HME components were able to detect all three targets in glass and plastic TADDs for at least 18 months after loading. Detection proficiency ranged from 64% to 100% and was not found to be dependent on either age of material.  相似文献   
9.
目的探讨millipore超滤管滤过方法对陈旧生物检材DNA分型检验的应用价值。方法将23份陈旧血样分别剪取同样合适大小的血片3组,标为A、B、C组,磁珠法提取DNA,分别用80μL、80μL、20μL洗脱液洗脱得到模板DNA,其中A、C组模板直接扩增,B组用millipore超滤管滤过浓缩后扩增。PCR产物用AB3130x L基因分析仪检测,Gene Mapper ID V3.2软件进行自动分型。所得实验数据用SPSS软件分析处理。结果 A组没有1例样本扩出全部STR基因座,B组有18例样本扩出全部STR基因座,C组有11个样本扩出全部STR基因座。结论应用millipore超滤管滤过方法可以明显提高陈旧生物检材的DNA分型成功率。  相似文献   
10.
Abstract: Ion mobility spectrometry (IMS) is a valued field detection technology because of its speed and high sensitivity, but IMS cannot easily resolve analytes of interest within mixtures. Coupling gas chromatography (GC) to IMS adds a separation capability to resolve complex matrices. A GC‐IONSCAN® operated in IMS and GC/IMS modes was evaluated with combinations of five explosives and four interferents. In 100 explosive/interferent combinations, IMS yielded 21 false positives while GC/IMS substantially reduced the occurrence of false positives to one. In addition, the results indicate that through redesign or modification of the preconcentrator there would be significant advantages to using GC/IMS, such as enhancement of the linear dynamic range (LDR) in some situations. By balancing sensitivity with LDR, GC/IMS could prove to be a very advantageous tool when addressing real world complex mixture situations.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号