首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
法律   18篇
中国政治   2篇
  2014年   3篇
  2013年   3篇
  2012年   1篇
  2011年   1篇
  2009年   1篇
  2008年   1篇
  2007年   4篇
  2006年   2篇
  2004年   1篇
  2003年   1篇
  2001年   1篇
  1984年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
The use of pyrolysis mass spectrometry (Py-MS) and statistical analysis of mass spectra is introduced as a method for “finger-printing” strains of Streptococcus salivarius. The objective is to provide correlative evidence regarding the identity of suspects in cases of assault or rape involving bite-marks. The results of the analysis of isolates from two individuals are presented, illustrating the differentiation of S. salivarius at strain level according to the origin of the isolate.  相似文献   
2.
Comparative analyses of 50 single‐layer white architectural paints were conducted to determine the discrimination power using standard techniques and to provide a basis for assessing significance when paints with limited features are not discriminated. Utilizing Fourier transform infrared spectroscopy (FTIR), 68 undifferentiated pairs resulted, yielding a discrimination of 94.45%. Adding stereomicroscopy, scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) and backscatter electron (BSE) imaging, and pyrolysis‐gas chromatography/mass spectrometry (Py‐GC/MS), the overall discrimination was 99.35%. The study included blind verification replicates, which resulted in the only pairs without indications of physical or chemical differences. The remaining groups of undifferentiated samples contained subtle differences by at least one technique, but were considered undifferentiated for the discrimination power evaluations. This study demonstrates a high degree of discrimination of single‐layer white architectural paints using methods of analysis often encountered in forensic science laboratories.  相似文献   
3.
4.
本文利用气相色谱仪,配以CZ—100热丝裂解器和FID检测器,对25种白色毛纤维进行比对分析,系统考察了织物在使用过程中经过日晒、汗渍的侵蚀、皂洗的处理后,对碱催化裂解气相色谱法分析毛纤维的影响,达到鉴别不同厂家、产地以及不同生产工艺白色毛纤维的目的。此方法可靠、快速、有效、便于操作,为各类案件中同类白色毛纤维的鉴定提供了一种切实可行的方法。  相似文献   
5.
Abstract: In this case report, potential interferences from an improvised fire‐extinguishing agent, a dishwashing liquid, containing linear alkylbenzene sulfonates (LAS), was studied. The presence of linear alkylbenzenes (LABs) in the fire debris sample was identified from the summed ion profile (SIP) analysis. It was found that the LAS from dishwashing liquids produce LABs by thermal degradation. Direct pyrolysis of a LAS‐containing dishwashing liquid at 300°C yielded a distribution of LABs in the SIP. LABs began to break down at pyrolysis temperatures between 450 and 500°C and completely break down by 800°C. Observed pyrolysis breakdown products of LABs included toluene, ethylbenzene, meta‐, para‐, and ortho‐xylenes, propylbenzene, indane, naphthalene, and 1‐ and 2‐methylnaphthalenes. These data suggested the presence of LABs in fire debris evidence might complicate subsequent analysis because their breakdown products contained some of the target compounds common to ignitable liquid identification. Therefore, a positive determination of the presence of foreign ignitable liquids should be carefully evaluated when there is a presence of LABs in the SIP.  相似文献   
6.
The detection of DNA is inhibited in cases of sexual assault involving condom use. Trace evidence, including condom lubricant residues, provides crucial associative evidence in such cases. The existing Fourier transform infrared spectroscopy (FTIR) methods for lubricant analysis and detection are limited with regard to sensitivity and discrimination. The aim of this research was to establish a new method as an alternative to FTIR for the analysis of condom lubricant residues. Pyrolysis gas chromatography-mass spectrometry (PyGC-MS) and GC-MS are highly sensitive methods of analysis for a wide range of chemical substances. PyGC-MS and GC-MS were used to analyze condom lubricants in standard solution, from clean swabs and from postcoital swabs. Pyrolysis of polydimethylsiloxane (PDMS) lubricant forms cyclic products known as cyclic dimethyl siloxanes (DMS), which are separated and detected by the GC-MS. The polyethylene glycol (PEG) lubricant can be analyzed by GC-MS directly from solution. The methods of extraction and analysis presented in this paper were shown to be significantly more sensitive than FTIR for the analysis of PDMS and PEG condom lubricants. PDMS was detected as low as 1 mug in standard solution and from clean swabs using the PyGC-MS method. PEG was detected as low as 0.5 microg from standard solution and 50 mug from clean swabs using the GC-MS method. Unfortunately, we were unable to provide further discrimination between condom brands and subbrands. The methods established throughout the research were used successfully to detect condom lubricants from donated postcoital swabs. Lubricants were detected in abundance on swabs 12 h postcoitus. Recommendations are made regarding implementation of new methods for routine analysis of casework samples along with strict pyrolysis interpretation criteria to minimize the possibility of misinterpretation of false positives.  相似文献   
7.
Conventional development of latent fingerprints is compromised when the prints are decomposed by extreme temperatures, such as those encountered when a weapon cartridge is fired, an improvised explosive device is detonated, and/or in arson cases. Understanding how these extreme temperatures alter the chemical and physical properties of latent fingerprint residue could aid in the discovery of a reagent that could effectively develop these decomposed fingerprints. To mimic scenarios where fingerprints may be exposed to high heat conditions, standards of the five most abundant amino acids in fingerprint residue as well as extracted fingerprint residue were pyrolized under controlled conditions. Compounds identified as pyrolytic decomposition products were 3,6-dimethylpiperazine-2,5-dione (from alanine), maleimide, and 2,5-furandione (from aspartic acid). The pyrograms and selected ion traces show these products to hold promise as indicators of decomposed fingerprint residues and, therefore, may serve as good candidate substrates for a developing reagent.  相似文献   
8.
Automobile tire marks can routinely be found at the scenes of crime, particularly hit-and-run accidents and are left on road surfaces because of sudden braking or the wheels spinning. The tire marks are left due to the friction between the tire rubber and the solid road surface, and do not always demonstrate the tire tread pattern. However, the tire mark will contain traces of the tire. In this study, Pyrolysis Gas Chromatography/Mass Spectrometry was used to analyze 12 tires from different manufacturer's and their traces collected after braking incidents. Tire marks were left on a conglomerate road surface with sudden braking. The samples were pyrolysed without removal of contaminant in a micro-furnace type pyrolyser. Quantitative and qualitative analysis were performed on all the samples. All 12 samples were distinguished from each other. Each of the tire traces were identified as coming from there original source.  相似文献   
9.
正Founded in the 1980s,Jinan Eco-Energy Technology Development Co.,Ltd.is a hi-tech company that specializes in developing and manufacturing equipments that recycle scrap rubber and plastic into fuel oil and carbon black.After more than 20 years of research and innovation,the company has become a trendsetter in the global industry.In 2012 the Chinese government sanctioned the company’s industrial standards for nationwide application.  相似文献   
10.
丁军凯  黄丽 《刑事技术》2003,(3):31-32,36
目的在裂解甲基化油脂分析中,考察并讨论了裂解器金属衬管对油脂定量分析的影响因素。方法采用气相色谱仪,FID检测器,FFAP毛细柱,热丝型裂解器及居里点裂解器,对大豆色拉油的五种主要组分:软脂酸,硬脂酸,油酸,亚油酸,亚麻酸进行了定量分析。结果(1)当在金属衬管内裂解分析时,裂解产物往往随极性的增大而吸附性增强;(2)在有酸,碱媒介裂解分析时,衬管的金属材质会对活性组分起到降解和催化转化作用;(3)这些因素的存在,会严重影响测定结果的准确性。结论采用金属衬管时,亚麻酸(n=5)RSD(%)高达14.07,而采用石英衬管时,RSD(%)则降至1.92。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号