首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
法律   10篇
中国政治   1篇
综合类   1篇
  2021年   1篇
  2018年   3篇
  2009年   4篇
  2008年   2篇
  2007年   1篇
  2006年   1篇
排序方式: 共有12条查询结果,搜索用时 31 毫秒
1.
The isotope ratios of amphetamine type stimulants (ATS) depend as well on the precursor as the synthetic pathway. For clandestine production of amphetamine and methamphetamine, 1-phenyl-2-propanone (P2P, benzylmethylketone) is a commonly used precursor.Our aim was to determine the variation of the isotope ratios within precursor samples of one manufacturer and to compare seized samples of unknown sources to these values. δ13CV-PDB, δ2HV-SMOW and δ18OV-SMOW isotope ratios were determined using elemental analysis (EA) and gas chromatography (GC) coupled to an isotope ratio mass spectrometer (IRMS). The comparison of all seized samples to the data of the samples of one manufacturer revealed considerable differences. The results show that IRMS provides a high potential in differentiating between precursors from different manufacturers for the clandestine production of ATS and identifying corresponding sources.  相似文献   
2.
The application of isotopic techniques to investigations requiring the provision of evidence to a Court is limited. The objective of this research was to investigate the application of light stable isotopes and isotope ratio mass spectrometry (IRMS) to solve complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques.Due to the current threat of organic peroxide explosives, such as triacetone triperoxide (TATP), research was undertaken to determine the potential of IRMS to differentiate samples of TATP that had been manufactured utilising different starting materials and/or manufacturing processes. In addition, due to the prevalence of pentaerythritoltetranitrate (PETN) in detonators, detonating cord, and boosters, the potential of the IRMS technique to differentiate PETN samples from different sources was also investigated.Carbon isotope values were measured in fourteen TATP samples, with three definite groups appearing in the initial sample set based on the carbon data alone. Four additional TATP samples (in a second set of samples) were distinguishable utilising the carbon and hydrogen isotopic compositions individually, and also in combination with the oxygen isotope values. The 3D plot of the carbon, oxygen and hydrogen data demonstrated the clear discrimination of the four samples of TATP. The carbon and nitrogen isotope values measured from fifteen PETN samples, allowed samples from different sources to be readily discriminated.This paper demonstrates the successful application of IRMS to the analysis of explosives of forensic interest to assist in discriminating samples from different sources. This research represents a preliminary evaluation of the IRMS technique for the measurement of stable isotope values in TATP and PETN samples, and supports the dedication of resources for a full evaluation of this application in order to achieve Court reportable IRMS results.  相似文献   
3.
An evaluation was undertaken to determine if isotope ratio mass spectrometry (IRMS) could assist in the investigation of complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques. The focus of the research was on ammonium nitrate (AN), a common oxidiser used in improvised explosive mixtures.The potential value of IRMS to attribute Australian AN samples to the manufacturing source was demonstrated through the development of a preliminary AN classification scheme based on nitrogen isotopes. Although the discrimination utilising nitrogen isotopes alone was limited and only relevant to samples from the three Australian manufacturers during the evaluated time period, the classification scheme has potential as an investigative aid.Combining oxygen and hydrogen stable isotope values permitted the differentiation of AN prills from three different Australian manufacturers. Samples from five different overseas sources could be differentiated utilising a combination of the nitrogen, oxygen and hydrogen isotope values. Limited differentiation between Australian and overseas prills was achieved for the samples analysed.The comparison of nitrogen isotope values from intact AN prill samples with those from post-blast AN prill residues highlighted that the nitrogen isotopic composition of the prills was not maintained post-blast; hence, limiting the technique to analysis of un-reacted explosive material.  相似文献   
4.
The drug trafficking is one of the most serious problems related to the Public Safety in Brazil, especially in the most populous areas of the country, as is the case of the city of São Paulo. In this work, it was developed a methodology that can help tracking the traffic routes of marijuana samples seized in the city of São Paulo, based on stable carbon and nitrogen isotopes, which are related to the climate and plant growth conditions. A model to classify the origin of unknown samples was built using linear discriminant analysis based on about 150 samples apprehended in the main producing regions of the country. Results for 76 samples seized in the city of São Paulo showed that most of them were cultivated in a humid region with the same origin as those from Mato Grosso do Sul. The provenance of 13 outliers samples from Northeast region (an important producing region) also were evaluated and some of them presented same profile of those from Mato Grosso do Sul, pointing to the existence of the traffic routes between the Northeast and Midwest region, probably as a consequence of the intensive field raids by Brazilian Federal Government since 1999.  相似文献   
5.
A total of 33 crude palm oil samples were randomly collected from different regions in Malaysia. Stable carbon isotopic composition (δ13C) was determined using Flash 2000 elemental analyzer while hydrogen and oxygen isotopic compositions (δ2H and δ18O) were analyzed by Thermo Finnigan TC/EA, wherein both instruments were coupled to an isotope ratio mass spectrometer. The bulk δ2H, δ18O and δ13C of the samples were analyzed by Hierarchical Cluster Analysis (HCA), Principal Component Analysis (PCA) and Orthogonal Partial Least Square-Discriminant Analysis (OPLS-DA). Unsupervised HCA and PCA methods have demonstrated that crude palm oil samples were grouped into clusters according to respective state. A predictive model was constructed by supervised OPLS-DA with good predictive power of 52.60%. Robustness of the predictive model was validated with overall accuracy of 71.43%. Blind test samples were correctly assigned to their respective cluster except for samples from southern region. δ18O was proposed as the promising discriminatory marker for discerning crude palm oil samples obtained from different regions. Stable isotopes profile was proven to be useful for origin traceability of crude palm oil samples at a narrower geographical area, i.e. based on regions in Malaysia. Predictive power and accuracy of the predictive model was expected to improve with the increase in sample size. Conclusively, the results in this study has fulfilled the main objective of this work where the simple approach of combining stable isotope analysis with chemometrics can be used to discriminate crude palm oil samples obtained from different regions in Malaysia. Overall, this study shows the feasibility of this approach to be used as a traceability assessment of crude palm oils.  相似文献   
6.
法的功能和法的作用辨异   总被引:8,自引:0,他引:8  
法的功能和法的作用是形式上相似而实质上有别的两个事物。法的功能是法所固有的内在属性,而法的作用是被赋予和设定的;法的功能是法所固有的稳定属性,而法的作用则需常有变动;法的功能是法所固有的应然属性,而法的作用则具有现实的指向。法的功能主要是描述性的,法律人应把握法的功能的天然禀性,尊重法的规律来发现和表述法的功能,使法的功能的潜质尽可能得以实现,而不要去做形式上所谓“充分发挥”而实质上则属于画蛇添足的徒劳工作。法的作用主要是规定性的,法律人应在充分利用既有条件的基础上,更好地创设和发挥法的作用,使其能够适合国家、社会和公民生活的实际需求。  相似文献   
7.
我国藏区分裂与反分裂斗争基本规律有:反分裂斗争必胜的规律;分裂与反分裂斗争时起时伏的规律;分裂势力内外勾结的规律;斗争双方主被动地位相互转化的规律。其特点具有涉外性、复杂性、隐蔽性、尖锐性、长期性。  相似文献   
8.
绝对贫困与相对贫困是贫困的两个阶段,一般先解决绝对贫困,再解决相对贫困.随着中国消除绝对贫困取得决定性胜利,扶贫随之进入解决相对贫困阶段.贫困发生理论认为,贫困问题成因复杂,相对贫困长期存在,为此,要制定有针对性的制度措施推动脱贫和防止返贫.有效解决相对贫困,既要遵循理论指导,又要结合中国实际,从调整扶贫战略、界定扶贫...  相似文献   
9.
Plastic cable ties can be utilised in a range of serious criminal activities and a comparison of cable ties, or fragments, may form part of the physical evidence presented to a Court of law. This research assessed the potential value of evidence based on the analysis of plastic cable ties. Twenty packets of black coloured plastic cable ties (nominally 200 mm × 4.8 mm) were purchased in pack sizes ranging from 25 to 100 individual cable ties (Brisbane, Australia, March 2015). Representative samples from each packet were visually examined, compared and tested to determine their physical dimensions, chemical compositions and stable isotopic compositions (δ2H, δ13C and δ15N).All of the individual cable ties from a given packet were found to be indistinguishable with respect to appearance, physical, chemical and isotopic measurements (within-batch variability). Individual cable ties were also found to be isotopically homogeneous with respect to hydrogen, carbon and nitrogen. All of the cable ties analysed were found to have very similar chemical compositions and to be manufactured predominantly from nylon 6,6. The elemental compositions of composite samples, prepared from each packet, were found to be highly variable and, as such, were of very limited value.Cable ties from ten of the twenty packets were uniquely characterised by physical appearance (between-batch variability). Physical measurements such as the width, thickness and tooth-count of the grip section did not provide additional discrimination. Cable ties from nineteen of the twenty packets were uniquely characterised by isotopic composition, based on δ2H and δ15N measurements. Samples from two packets of Crescent brand cable ties were found to be indistinguishable with respect to all of the tests applied in this study. These two packets were inadvertently purchased from the same retailer and had the same barcode and batch number. It was considered a reasonable assumption that these two packets originated from the same manufacturing batch.The authors reason that a likelihood ratio (that might be presented to a Court of law) can be derived from this type of discrete data based on a calculation of the possible combinations of distinguishable objects (unordered sampling with replacement) in a convenience sample collected from the background population. In this example, a database of 19 distinguishable objects can yield a likelihood ratio as high as 210, with a verbal equivalent of “moderately strong support” for a proposition that two cable ties have the same isotopic composition because they originate from the same batch rather than by random chance.  相似文献   
10.
For nearly 30 years, the methods utilized in illicit cocaine hydrochloride production have remained relatively consistent. Cocaine hydrochloride is typically produced one kilogram at a time. As a result, each individual kilogram is unique and distinct from other kilograms in any particular seizure based on the total alkaloid profile, occluded solvent profile, and isotopic signature. Additionally, multi-kilogram cocaine seizures are often comprised of cocaine from several different coca growing regions. There has been a documented shift in this type of processing based on the recent analysis of a large cocaine seizure in the Eastern Pacific. Signature analyses of samples from 21 kg randomly selected from a 517 kg seizure were virtually identical. Triplicate analyses of each sample via gas chromatography with flame ionization detection, static headspace gas chromatography mass spectrometry, and isotope ratio mass spectrometry were completed. An initial outlier evaluation of the data and an in-depth univariate analysis indicated there was no statistically significant difference among the 21 samples at the 95% confidence interval. Principal components analysis did reveal consistent minor deviations between the samples and known authentic data from the Nariño coca growing region of Colombia. These deviations were only observed on the latter principal components and could be explained by differences in solvent selection during cocaine hydrochloride processing. Chemical analyses in addition to a thorough statistical evaluation suggest a shift in the traditional small-batch method of cocaine processing to a multi-kilogram, high throughput approach.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号