Solid phase extraction method for rapid isolation and clean-up of some synthetic pyrethroid insecticides from human urine and plasma. |
| |
Authors: | L Junting F Chuichang |
| |
Affiliation: | Department of Forensic Chemistry, Faculty of Forensic Medicine, China Medical University, Shenyang. |
| |
Abstract: | A simple and rapid method for the isolation of seven synthetic pyrethroid insecticides (methothrin, fenpropathrin, cyhalothrin, permethrin, cypermethrin, fenvalerate, deltamethrin) with a solid phase extraction (SPE), utilizing Sep-Pak C18 cartridges, from human urine and plasma is presented. The detection of the insecticides was performed using a wide bore capillary gas chromatograph (GC) with flame ionization detection (FID). The insecticide-containing samples mixed with 70% methanol were directly applied to the cartridges and eluted with 2 ml chloroform. The recoveries using the cartridges were between 90-102% for urine and 81-93% for plasma. Mixing samples with 70% methanol prior to extraction, seems very useful for the screening of synthetic pyrethroid insecticides. |
| |
Keywords: | |
|
|