首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Improved method for the detection of TATP after explosion
Authors:Muller D  Levy A  Shelef R  Abramovich-Bar S  Sonenfeld D  Tamiri T
Institution:Division of Identification and Forensic Science, Israel Police Headquarters, Jerusalem 91906, Israel. dlikim@police.gov.il
Abstract:TATP in post explosion exhibits was reported earlier to be best recovered from vapor phase. A typical procedure includes its adsorption on Amberlite XAD-7, elution with acetonitrile and analysis by GC/MS. In this work, improved recovery of TATP from the vapor phase was achieved by SPME using PDMS/DVB fiber and immediate sampling to GC/MS. The recovery of TATP by SPME was compared with headspace and with adsorption on Amberlite XAD-7 by spiking onto filter paper put in a 100 mL beaker. The limit of detection of TATP was 6.4 ng in these conditions, few orders magnitude more than in the other tested methods. Recovery of TATP in the presence of various solvents was also studied. Acetone, water, and mixtures of water:alcohols (1:1) were found to reduce the recovery of TATP. Using SPME, TATP has been identified in dozens of post-explosion cases.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号