首页 | 本学科首页   官方微博 | 高级检索  
     


Vapor Intrusion into Large Commercial/Industrial Facilities
Authors:Robin Wright  Jessica Illaszewicz
Abstract:Inhalation exposure from vapor intrusion has become a priority over the past several years for federal, state, tribal, and local environmental agencies. This article discusses the identification of vapor intrusion conditions and mitigation approaches for large commercial and industrial facilities. Factors to be considered in the design and implementation of remedial measures to address source areas below a building include identification of source areas, access to the sources, feasibility of active remedial technologies to address the source area, and whether a remedial technology will be effective in reducing or eliminating the potential for vapor intrusion into the overlying building. In the event a mitigation system is deemed appropriate, the key factors to be considered in the design and construction of such systems include size and construction details for the building; uses and occupancy type; and type of heating, ventilation, and air conditioning (HVAC) systems in the building and associated air exchange rates and operation and maintenance considerations. This topic will remain a priority for regulatory agencies and a key concern of building owners.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏