Two examples of null alleles at the D19S433 locus due to the same 4 bp deletion in the presumptive primer binding site of the AmpFlSTR Identifiler kit |
| |
Authors: | E.M. Dauber B. Glock W.R. Mayr |
| |
Affiliation: | Division of Blood Group Serology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria |
| |
Abstract: | Two cases of allelic loss at the D19S433 locus after multiplex PCR with the AmpFlSTR Identifiler kit (Applied Biosystems) are described. In both cases the failure of PCR resulted in genetic inconsistencies due to opposite homozygosity. After singleplex PCR with published primers additional alleles were observed and Mendelian inheritance was restored. These PCR products were sequenced and in both cases the same 4 bp deletion near the 3′ end of the repeat region was detected in two alleles of different length. The frequency of these null alleles (two events in 1026 allelic transfers) amounts to 0.0019 (95% confidence limits: 0.0002-0.0070). |
| |
Keywords: | D19S433 Null allele Primer binding site mutation |
本文献已被 ScienceDirect 等数据库收录! |