首页 | 本学科首页   官方微博 | 高级检索  
     


Validation of the AMPFℓSTR® MiniFilerTM PCR Amplification Kit for Use in Forensic Casework*
Authors:Coral Luce M.S.  Shawn Montpetit M.S.  David Gangitano Ph.D.  Patrick O’Donnell Ph.D.
Affiliation:1. Sam Houston State University, Chemistry and Forensic Science Bldg., 1003 Bowers Blvd., Huntsville, TX 77340.;2. San Diego Police Department, 1401 Broadway, San Diego, CA 92101.
Abstract:Abstract: The AmpF?STR® MiniFilerTM PCR Amplification Kit is designed to genotype degraded and/or inhibited DNA samples when the AmpF?STR® IdentifilerTM PCR Amplification Kit is incapable of generating a complete genetic profile. Validation experiments, following the SWGDAM guidelines, were designed to evaluate the performance of MiniFiler. Data obtained demonstrated that MiniFiler, when used in conjunction with Identifiler, provided an increased ability to obtain genetic profiles from challenged samples. The optimum template range was found to be between 0.2 and 0.6 ng, with 0.3 ng yielding the best results. Full concordance was achieved between the MiniFiler kit and Identifiler kit except in a single case of a null allele at locus D21S11. Numerous instances of severe heterozygous peak imbalance (<50%) were observed in single source samples amplified within the optimum range of input DNA suggesting that caution be taken when attempting to deduce component genotypes in a mixture.
Keywords:forensic science  DNA typing  miniSTR  D13S317  D7S820  D2S1338  D21S11  D16S539  D18S51  CSF1PO  FGA  polymerase chain reaction  validation  AmpFℓ  STR
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号