首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Profiling of illicit fentanyl using UHPLC-MS/MS
Authors:Lurie Ira S  Berrier Arthur L  Casale John F  Iio Reiko  Bozenko Joseph S
Institution:U.S. Drug Enforcement Administration, Special Testing and Research Laboratory, 22624 Dulles Summit Court, Dulles, VA 20166, USA. ira.s.lurie@usdoj.gov
Abstract:Methodology is presented for the profiling of fentanyl in seized drugs using ultra high performance liquid chromatography in combination with tandem mass spectrometry (UHPLC-MS/MS). Target analysis was performed for 40 fentanyl processing impurities, several of which are markers for a specific synthetic route (Siegfried or Janssen). For the separation of these solutes, an Acquity BEH C18 1.7 μm particle column (150 mm × 2.1 mm) with a binary 1% formic acid (pH 2.0)/acetonitrile gradient was used. For MS/MS detection, an atmospheric pressure positive electrospray source was employed with selected reaction monitoring (SRM). The coupling of the high separation power of UHPLC with the highly selective and sensitive detection of MS/MS is amenable to the determination of synthetic route and linking of drug seizures. The technology is also applicable to exhibits containing trace levels of fentanyl in the presence of significantly excess amounts of heroin and/or adulterants.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号