首页 | 本学科首页   官方微博 | 高级检索  
     

两种铁铬合金电警棍遗留金属颗粒成分分析
引用本文:邵熠,赵春梅,陈庆,刘力. 两种铁铬合金电警棍遗留金属颗粒成分分析[J]. 中国法医学杂志, 2020, 0(1): 80-83
作者姓名:邵熠  赵春梅  陈庆  刘力
作者单位:山西医科大学法医学院;北京市公安司法鉴定中心
摘    要:目的检测两种电警棍铁铬合金电极遗留金属颗粒的成分,对同一电警棍电击前后遗留金属颗粒成分特征进行分析,对电警棍遗留金属颗粒成分的稳定性、差异性进行评价。方法使用电警棍分别多次摩擦滤纸和电击猪皮,使用碳导电胶带粘取遗留金属颗粒,应用SEM/EDS技术检测颗粒元素成分,并对数据进行统计学分析。结果两种电警棍电击前遗留铁铬合金颗粒及电击后遗留铁铬合金颗粒成分均稳定,存在差异;实验两种电警棍电击后遗留金属颗粒成分分布发生显著变化,除原成分铁铬颗粒外,实验猪皮表面均检出全新成分的铁铬合金颗粒,且两种电警棍电击后产生的全新铁铬颗粒成分稳定无显著差异。结论通过分析两种电警棍铁铬电极电击前后遗留多金属颗粒成分分布特征,可以实现对两种电警棍电极的识别,为人体电警棍损伤的识别与认定提供技术支持和理论依据。

关 键 词:法医病理学  金属成分认定  铁铬合金  SEM/EDS  遗留金属颗粒

Composition analysis of residual metal particles left by two ferrochrome electric batons
Shao Ti,Zhao Chunmei,Chen Qing,Liu Li. Composition analysis of residual metal particles left by two ferrochrome electric batons[J]. Chinese Journal of Forensic Medicine, 2020, 0(1): 80-83
Authors:Shao Ti  Zhao Chunmei  Chen Qing  Liu Li
Affiliation:(School of Forensic Medicine,Shanxi University,Taiyuan 030001,China;Judicial Authentication Center of Beijing Public Security,Beijing 100192,China)
Abstract:Objective To detect the composition of residual metal particles left by two electric baton ferrochrome electrodes,analize the characteristics of metal particles before and after electric shock with the same electric baton,and evaluate the stability and difference of the composition of metal particles left by eclectric baton.Methods Electric batons were used repeatly to rub against filter papers and discharge on the surface of pig skin,carbon conductive tape was applied to pick up the remaining metal particles,SEM/EDS technology was used to detect the composition of particles,and the data was processed statistically.Results The composition of ferrochrome alloy particle before and after electric shock were stable but different.The composition distribution of metal particles left by two electric batons after electric shock has changed significantly.In addition to the original ferrochrome particles,a brand new type of particle was detected on the surface of the experimental pig skin.And these new particles left by two different electric batons were statistically stable and almost the same.Conclusion By analyzing the distribution feature of polymetallic particles left by two electric baton ferrochrome electrodes before and after electric shock,the identification of two electric baton electrodes can be realized,which provides technical support and theoretical basis for the identification of human body electric baton injury.
Keywords:Forensic pathology  Determination of metal composition  Ferrochrome alloy  SEM/EDS  Residual metal particles
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号