首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of two instrumental methods of comparing writing paper
Authors:Kumar Rajesh
Affiliation:Physics and Ballistics Division, State Forensic Science Laboratory, Himachal Pradesh, Junga, Shimla, 173216 India. rkumar.65@gmail.com
Abstract:An organization had approved the sample of writing paper, and accordingly the supplier had to execute the supply. The supply received was suspected to be of different quality from approved one. The organization sent the samples for comparison to the Forensic Science Laboratory. Both the approved and supplied samples were compared using Tensile Testing Method with the Material Testing Machine and Fluorescence and spectral analysis using the Video Spectral Comparator (VSC2000). The difference between the mean loads at peak before rupture in the tensile testing mode for the two samples was about 33%. The two samples differed significantly in terms of UV fluorescence, and there was about 5% average difference in the percentage of maximum reflected intensity in the wavelength region of 400-900 nm. It has been observed in this study that these two methods can adequately distinguish paper samples of different origin.
Keywords:forensic science  paper quality  tensile strength  tensile index  tension length  fluorescence
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏