首页 | 本学科首页   官方微博 | 高级检索  
     


Quantitation of Synthetic Cannabinoids in Plant Materials Using High Performance Liquid Chromatography with UV Detection (Validated Method)
Authors:Laura A. Ciolino Ph.D.
Affiliation:Forensic Chemistry Center, US Food and Drug Administration, Cincinnati, OH
Abstract:Plant based products laced with synthetic cannabinoids have become popular substances of abuse over the last decade. Quantitative analysis for synthetic cannabinoid content in the laced materials is necessary for health hazard assessments addressing overall exposure and toxicity when the products are smoked. A validated, broadly applicable HPLC‐UV method for the determination of synthetic cannabinoids in plant materials is presented, using acetonitrile extraction and separation on a commercial phenylhexyl stationary phase. UV detection provides excellent sensitivity with limits of quantitation (LOQs) less than 10 μg/g for many cannabinoids. The method was validated for several structural classes (dibenzopyrans, cyclohexylphenols, naphthoylindoles, benzoylindoles, phenylacetylindoles, tetramethylcyclopropylindoles) based on spike recovery experiments in multiple plant materials over a wide cannabinoid contents range (0.1–81 mg/g). Average recovery across 32 cannabinoids was 94% for marshmallow leaf, 95% for damiana leaf, and 92% for mullein leaf. The method was applied to a series of case‐related products with determined amounts ranging from 0.2 to >100 mg/g.
Keywords:forensic science  synthetic cannabinoids  synthetic marijuana  synthetic cannabis  quantitative analysis  plant products  herbals  high performance liquid chromatography‐ultraviolet detection  validated method
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号