首页 | 本学科首页   官方微博 | 高级检索  
     


Rapid isolation with Sep-Pak C18 cartridges and capillary gas chromatography of triazine herbicides in human body fluids.
Authors:T Kumazawa  K Sato  H Seno  O Suzuki
Affiliation:Department of Legal Medicine, Hamamatsu University School of Medicine, Japan.
Abstract:A simple and rapid method, for the isolation of eight triazine herbicides from human serum and urine, using Sep-Pak C18 cartridges is presented. After mixing with distilled water, serum and urine samples containing the herbicides, were loaded on Sep-Pak C18 cartridges and eluted with either chloroform only or chloroform/methanol (9:1). The herbicides were detected by capillary gas chromatography with both flame ionization detection (FID) and nitrogen-phosphorus detection (NPD). Separation of eight triazine herbicides from each other and from impurities was generally satisfactory with the use of a non-polar DB-1 capillary column. Recovery of most compounds was excellent for both chloroform and chloroform/methanol (9:1) as elution solvents. Backgrounds were cleaner and evaporation time was shorter for the chloroform only than for the chloroform/methanol (9:1). The NPD gave sensitivity more than 10-20 times higher than that of FID.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号