Trace DNA collection—Performance of minitape and three different swabs |
| |
Authors: | Oskar Hansson,Marianne Finnebraaten,Ingebjø rg Knutsen Heitmann,Merete Ramse,Mariam Bouzga |
| |
Affiliation: | Institute of Forensic Medicine, University of Oslo, Rikshospitalet, NO-0027 Oslo, Norway |
| |
Abstract: | In this study two types of synthetic swabs and one commercially available minitape were tested and compared with the currently used cotton swab. The results indicate that there is no major difference in performance between the swabs for recovery of trace samples, and that the minitape is better suitable for recovering from absorbent materials than swabs are. However, no statistical calculations were carried out due to the low number of samples in each category. |
| |
Keywords: | Minitape Swab Soluble tape Chelex Biorobot EZ1 |
本文献已被 ScienceDirect 等数据库收录! |
|