首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Abstract:  Automated scanning electron microscopy with energy dispersive spectroscopy has been used to analyze airbag residue particles. Analysis of airbag residue from some passenger side airbags revealed some residue particles which are consistent with gunshot residue (GSR) samples. The source of these particles was determined to be percussion primers used to initiate the chemical reaction for deployment. This article identifies some vehicles which contain this type of airbag and demonstrates the types of particles which could be misidentified as being GSR. The low numbers of GSR particles in among the large particle populations of zirconium and/or copper–cobalt particles, which are clearly airbag residue, allow the trained analysts to distinguish the correct source of this residue. Particles containing high aluminum levels, elevated levels of allowable elements in GSR particles, or the presence of elements that are rare in GSR particles stand out as indications that the particles are not GSR in origin. This study serves as a guide to analysts who perform particle analysis in forensic investigations.  相似文献   

2.
We devised a simple and rapid method for detection of gunshot residue (GSR) particles, using scanning electron microscopy/wavelength dispersive X-ray (SEM/WDX) analysis. Experiments were done on samples containing GSR particles obtained from hands, hair, face, and clothing, using double-sided adhesive coated aluminum stubs (tape-lift method). SEM/WDX analyses for GSR were carried out in three steps: the first step was map analysis for barium (Ba) to search for GSR particles from lead styphnate primed ammunition, or tin (Sn) to search for GSR particles from mercury fulminate primed ammunition. The second step was determination of the location of GSR particles by X-ray imaging of Ba or Sn at a magnification of x 1000-2000 in the SEM, using data of map analysis, and the third step was identification of GSR particles, using WDX spectrometers. Analysis of samples from each primer of a stub took about 3 h. Practical applications were shown for utility of this method.  相似文献   

3.
The computer automated scanning electron microscope. X-ray microanalysis of Firearms Discharge Residue (FDR) can reveal substantial information about the circumstances of their generation beyond the presence of characteristic gunshot residue (GSR). Indicators of the type of weapon and ammunition used can he obtained from the distribution of GSR particle shapes and from the multi-element analysis of the FDR sample. This is demonstrated for a large database of GSR samples from nine different handguns and over 60 different ammunitions. An example classification scheme is presented for the supporting particles generally found present in FDR. When particle type area concentration ratios are normalized to the iron (Fe) particle type, results show it is possible to distinguish much about the metal used in the weapon manufacture, whether it was of large or small caliber, whether the bullets were jacketed or plated, and whether the cartridge cases were of aluminum, brass, or nickel-plated brass. Standardization of such analytical schemes would be advantageous.  相似文献   

4.
The main disadvantage to gunshot residue (GSR) particle analysis utilizing scanning electron microscope/energy dispersive X-ray (SEM/EDX) instrumentation has been the excessive operator time required for search and identification. This study uses an automated particle search and characterization program for unattended GSR search and identification. This system allows for automatic matrix search, particle sizing, chemical typing, and spectral aquisition with subsequent storage of data to disk for later operator review and verification. This work describes various aspects of the program, determines appropriate parameters adequate for both unique and characteristic GSR particle identification, and evaluates the reliability of data obtained. Samples are collected via the tape lift method from test-firings of .38, .32, .25, and .22 caliber handguns at time after firing intervals of 0 to 6 h. Unique GSR particles are consistently and correctly identified by this method on tape lift samples taken up to 4 h after firing. False positive results of unique GSR particles are not encountered on control handblank samples. This technique appears to provide the forensic science community with an operator-free method of reliable GSR particle search and an improved analyst-time-per-case ratio.  相似文献   

5.
Gunshot Residue (GSR) produced by the discharge of a firearm often provides very useful information in criminal investigations in cases involving the use of firearms. Scanning Electron Microscopy equipped with an Energy Dispersive X-ray Spectrometer (SEM-EDS) is typically used worldwide to visualize micrometric particles constituting GSR and to analyse their elemental composition. The 2017 ASTM Standard guide for gunshot residue analysis by scanning electron microscopy/energy dispersive X-ray spectroscopy specifies that “Particles classified as characteristic of GSR will have one of the following elemental compositions: Lead, antimony, barium; Lead, barium, calcium, silicon, tin”. For the first time, the presence of an additional element, such as Sn, plays a key role in ASTM particle classification. It is known that some ammunitions, used for pistols, revolvers and rifles, contain tin foil discs for sealing the primer mixture into the cup, resulting in GSR particles containing Sn. The authors faced some cases in which Sn was unexpectedly found in GSR particles from a 0.22 Long Rifle derringer and from some 12 gauge shotguns. No tin foil discs are used in rimfire ammunitions and there is no published evidence of tin foil discs in shotshell ammunitions. Following a “case by case” approach, experimental research has been carried out to explain how Sn can be present in GSR particles when the last discharged cartridge also does not contain any Sn either in components and in the explosive charges.Moreover, the use of Particle Induced X-ray Emission (PIXE) showed the capability to overcome overlap ambiguity of Sb and Sn peaks in the X-ray spectra, being a possible key issue in real shooting cases if Sn quantities are below the lower limit of SEM detection, especially when Sb is also present.  相似文献   

6.
A review of the scientific papers published on inorganic gunshot residue (GSR) analysis permits to study how the particle analysis has shown its capability in detection and identification of gunshot residue. The scanning electron microscope can be the most powerful tool for forensic scientists to determine the proximity to a discharging firearm and/or the contact with a surface exposed to GSR. Particle analysis can identify individual gunshot residue particles through both morphological and elemental characteristics. When particles are detected on the collected sample, the analytical results can be interpreted following rules of a formal general interpretative system, to determine whether they come from the explosion of a primer or from other possible sources. The particles on the sample are compared with an abstract idea of "unique" GSR particle produced by the sole source of the explosion of a primer. "Uniqueness" is not the only problem related to GSR detection and identification for a forensic scientist. With "not-unique" particles interpretation of results is extremely important. The evidential strength of "not-unique" particles can increase with a more fruitful interpretative framework based on Bayes rule. For the assessment of the value of a GSR in linking a suspect and a crime, it is important to compare two hypothesis: the first can be that of the evidence if the suspect has been shooting in a specific situation, the second that of the evidence if the suspect was not involved in this shooting. This case specific or case-by-case approach is closer to what the court is interested in. The authors consider that a "case-by-case" approach should be followed whenever possible. Research of models and data such as those developed in other trace evidence material (fibres, glass, etc.) using a Bayesian approach is suggested in the interpretation of GSR.  相似文献   

7.
In 0.22 caliber rimfire ammunition, the primer often contains lead or lead and barium compounds. As residues from these primers do not contain lead, barium, and antimony, they cannot be uniquely classified as gunshot residue (GSR) under ASTM designation E 1588-95. In many types of 0.22 caliber rimfire ammunition, the cartridge contains a primer sensitized with glass. In this paper we describe a previously unreported type of GSR particle consisting of glass fused with other primer components. As there appear to be few potential environmental or occupational sources of particles composed of lead and barium compounds fused to glass, particularly borosilicate glass, these particles may have high evidential value. Scanning electron microscopy with energy dispersive X-ray detection (SEM-EDX) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were evaluated for the characterization of glass-containing GSR particles. The occurrence of glass-containing GSR particles was established in the residue from various brands of 0.22 caliber ammunition, and several sub-types were identified.  相似文献   

8.
These experiments were designed to determine whether skin debris (desquamated epithelial cells and apparent skin oils) affects gunshot residue (GSR) particle detection on the sticky tape lift samples prepared for scanning electron microscopy (SEM). A dabbing experiment showed that GSR particles accumulate not only on the adhesive surface of the sampler, but also on the epithelial cell surfaces. Samplers were loaded with target GSR followed by dabbing 30 times on the back of a hand. Backscatter electron images were taken at 20 kV and for some at 30 kV of the same areas. The samplers were then treated with a sodium/calcium hypochlorite solution (bleach) to remove skin debris and again imaged in the SEM. Comparison of these images shows more GSR particles will likely be revealed at 30 kV than 20 kV and more particles revealed by the bleach treatment in an automated SEM system.  相似文献   

9.
Preparation of a ytterbium‐tagged gunshot residue (GSR) reference standard for scanning electron microscopy and energy dispersive X‐ray spectroscopic (SEM‐EDS) microanalysis is reported. Two different chemical markers, ytterbium and neodymium, were evaluated by spiking the primers of 38 Special ammunition cartridges (no propellant, no projectile) and discharging them onto 12.7 mm diameter aluminum SEM pin stubs. Following SEM‐EDS microanalysis, the majority of tri‐component particles containing lead, barium, and antimony (PbBaSb) were successfully tagged with the chemical marker. Results demonstrate a primer spiked with 0.75% weight percent of ytterbium nitrate affords PbBaSb particles characteristic of GSR with a ytterbium inclusion efficiency of between 77% and 100%. Reproducibility of the method was verified, and durability of the ytterbium‐tagged tri‐component particles under repeated SEM‐EDS analysis was also tested. The ytterbium‐tagged PbBaSb particles impart synthetic traceability to a GSR reference standard and are suitable for analysis alongside case work samples, as a positive control for quality assurance purposes.  相似文献   

10.
Gunshot residue (GSR) analysis is a frequently used forensic method for investigating shooting events. In this process, GSR-particles are detected on pertinent objects, often the hands of a suspect, with energy dispersive X-ray microanalysis in a scanning electron microscope. The question asked in court is usually the following: "… has or has not a given shot been fired by the suspect (at a certain place and time)?" Unfortunately, this question frequently cannot be answered by the analyst. Only the presence or absence of "characteristic" GSR-particles on the investigated sample can be stated with confidence. All other assumptions are inherently biased by many factors that are usually only known by the culprit or are generally unknown. In order to draw more profound conclusions from GSR analytical results, the dynamics of GSR particles have to be considered, i.e., how these particles reach a suspect. Consequently, the formation of the plume after firing was investigated for eleven different firearms with high speed-video analysis. The results show that a vast scope exists between revolvers - distributing many particles near the shooter - and e.g. shotguns that are quite sealed. These differences between the various weapon types should be considered for interpretation of the results of GSR-analysis.  相似文献   

11.
The purpose of this survey was to determine the methods of analysis being used on gunshot residue (GSR) samples in forensic science laboratories across the United States. In addition, the two general techniques of GSR analysis are compared and contrasted. Problems encountered by analysts using scanning electron microscopy/energy-dispersive X-ray analysis (SEM/EDX) are discussed.  相似文献   

12.
Only limited data currently exists on the inadvertent transfer of gunshot residue (GSR), or GSR-like particles through contact with public places. In this study, an assessment occurrence of GSR in public environments in England, UK was undertaken. Utilizing a stubbing sampling technique over 260 samples were collected from areas accessible to the public, including buses, trains, taxis, and train stations. Stub analysis was performed by Scanning Electron Microscopy with Energy Dispersive X-ray Analysis (SEM-EDX). The results showed no characteristic GSR particles were detected on any of the 262 samples taken. From these samples, a total of four indicative/consistent particles were identified on one train seat (2× BaAl, 2× PbSb). Although geographical location and firearm association is likely to influence GSR occurrence, the data suggests that the potential for inadvertent GSR transfer through contact with public transport and associated communal areas is insignificant. Further research assessing environmental background levels of GSR in additional geographical locations is critical in an evaluation of the potential for GSR transfer from the environment.  相似文献   

13.
The application of time-of-flight secondary ion mass spectrometry (TOF-SIMS) for the characterisation of gunshot residue (GSR) from 0.22 caliber rimfire ammunition is reported. Results obtained by TOF-SIMS were compared with conventional scanning electron microscopy (SEM) studies. As could be expected, TOF-SIMS exhibited greater elemental sensitivity than SEM equipped with energy dispersive X-ray detection (SEM-EDX), and was also capable of detecting fragments characteristic of inorganic compounds. This preliminary study indicates that TOF-SIMS offers substantial potential for forensic GSR examinations as a complementary technique to SEM-EDX. In addition TOF-SIMS is applicable to the analysis of individual particles in the typical size range encountered in GSR casework.  相似文献   

14.
Gunshot residue (GSR) from the discharge of ammunition can provide crucial information in reconstructing criminal cases. Traditional primers create particles of heavy metals such as lead, barium, and antimony. In forensic laboratories, automatic inorganic particle detection is performed by scanning electron microscopy (SEM), using the backscattered electron signal to search for bright residues among the many darker environmental particles, due to higher electron density of the former. Some innovative primers, indicated as heavy metal‐free (HMF), produce a residue of elements with atomic numbers below 21, urgently demanding new detecting solutions. For the first time, residues from Sellier & Bellot Nontox HMF primer are demonstrated to emit visible light under electron beam stimulation in a SEM. Cathodoluminescence is then proposed as a promising tool to both detect and characterize residues in forensic cases involving HMF primers, with minor changes to traditional analytical apparatus used for inorganic GSR analysis.  相似文献   

15.
Suspects in shooting investigations in Chicago are routinely transported in department vehicles and detained in department facilities prior to gunshot residue (GSR) evidence collection. The GSR test results are used to associate the suspect with primary exposure to GSR. The potential for these vehicles and facilities being sources of secondary GSR contamination needed to be determined. A total of 201 samples were collected from randomly selected vehicles and detention facilities. The sampling collected trace materials from surfaces that suspects' hands may contact during the arrest process. These samples were examined for the presence of GSR particles using scanning electron microscopy. Upon completion of the automated analysis, those particles that met an initial GSR screening criterion were relocated and reanalyzed. The locations where GSR particles were recovered allowed us to make recommendations to the Chicago Police Department with regard to transporting and detaining these suspects. The low number of GSR particles recovered suggests that the potential for secondary contamination, although present, is relatively low.  相似文献   

16.
In light of past research being targeted to find specific particles which may be similar to gunshot residue (GSR), this project was formulated to detect any possible particulate by random particle fallout onto substrates at firework displays and to assess the impact this may have on GSR evidence. Firework residue was collected at a display site, from amongst spectators as well as from the author's hair 90min after the display. SEM-EDX analysis has detected such particulate in all three scenarios, with the firework particle population at large providing a solid ground for discrimination from GSR. Wind dispersal was found to decrease the particle population and subsequently, the latter's discriminatory power. Some particles, if treated individually were found to be indistinguishable from GSR. Findings also include residues which may mimic strontium based GSR as well as GSR which may be mixed with that from previous firings. The continuous changes made to primer and propellant compositions by manufacturers also call for greater consideration when classifying particles as originating from pyrotechnic devices. Furthermore, authorities such as police forces should be made more aware about the incidence of such particle transfer in firework related periods.  相似文献   

17.
Abstract: The collection efficiency of two widely used gunshot residue (GSR) collection techniques—carbon‐coated adhesive stubs and alcohol swabs—has been compared by counting the number of characteristic GSR particles collected from the firing hand of a shooter after firing one round. Samples were analyzed with both scanning electron microscopy and energy dispersive X‐rays by an experienced GSR analyst, and the number of particles on each sample containing Pb, Ba, and Sb counted. The adhesive stubs showed a greater collection efficiency as all 24 samples gave positive results for GSR particles whereas the swabs gave only positive results for half of the 24 samples. Results showed a statistically significant collection efficiency for the stub collection method and likely reasons for this are considered.  相似文献   

18.
Abstract: A comprehensive review of the scientific literature on gunshot residue (GSR) is presented. Aspects of both inorganic and organic GSR are discussed, from formation and distribution, to sample collection, preparation, and analysis using a variety of techniques. The interpretation of GSR results is also considered including issues surrounding the contamination, distribution, and transfer of GSR. Potential problems with ulterior sources of GSR like particles have been reported in the literature. For example, particles from environmental and occupational sources have been highlighted as exhibiting similar chemical and morphological characteristics to GSR. These findings are put into context with regard to interpreting samples. A move toward a “case by case” approach is argued to be more preferable to a “formal” classification system where possible. The analysis of both inorganic and organic compositions of residue samples as well as morphological considerations is considered to be a more ideal approach to GSR analysis, whereever practicable.  相似文献   

19.
Abstract: Variations in gunshot residue (GSR) compositions are used in the reconstruction of shooting incidents. In this study, GSR samples taken from seven different locations around and in the firearm were collected and analyzed using scanning electron microscopy/energy dispersive X‐ray analysis. Four different types of ammunition were applied. Very low correlations were found when different ammunition were used. This clearly shows that it is possible to differentiate between ammunition types. When the same ammunition was used, high correlations were found between samples taken from external positions (such as hands of shooter, bullet‐entrance holes) but poor correlation was found between internal samples (such as firearm barrel, cartridge case) and external samples. A high degree of association was found between samples that simulated victim and shooter. These findings clearly demonstrate that GSR comparison studies are meaningful but care needs to be taken when choosing suitable exhibits. External samples (such as hands of shooter, bullet‐entrance holes) are more suitable candidates than internal samples (barrel of the firearm, cartridge case).  相似文献   

20.
Following previous work on differentiation between gunshot residue according to the type of ammunition used, a specific investigation was undertaken of traces originating from 9 mm Luger ammunition using SEM-EDX. The aim of this study was to determine whether GSR originating from this type of ammunition is similar, or whether differentiation could be made between particular manufacturers of Luger ammunition. The results were collected in the form of counts of particles in each of seven key elemental classes being combinations of lead, antimony and barium. These were then adjusted to a factor known as frequency of occurrence which allows comparison of the distribution of particles within the classes between samples with differences in absolute particle counts. The relationships between the samples were examined using non-parametric statistical tests: R-Spearman and tau-Kendall rank correlation coefficients. It has been found that most of the studied samples of GSR were similar to each other despite their originating from various manufacturers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号