首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liquid chromatography/mass spectrometry (LC/ MS) and matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS methods were developed for the presumptive identification of ricin toxin and the alkaloid marker ricinine from crude plant materials. Ricin is an extremely potent poison, which is of forensic interest due to its appearance in terrorism literature and its potential for use as a homicide agent. Difficulties arise in attempting to analyze ricin because it is a large heterogeneous protein with glycosylation. The general protein identification scheme developed uses LC/MS or MALDI-TOF for size classification followed by the use of the same instrumentation for the analysis of the tryptic digest. Fragments of the digest can be searched in an online database for tentative identification of the unknown protein and then followed by comparison to authentic reference materials. LC fractionation or molecular weight cutoff filtration was used for preparation of the intact toxin before analysis. Extracts from two types of castor beans were prepared using a terrorist handbook procedure and determined to contain 1% ricin. Additionally, a forensic sample suspected to contain ricin was analyzed using the presented identification scheme (data not shown). The identification of the alkaloid ricinine by GC/MS and LC/MS was shown to be a complementary technique for the determination of castor bean extracts.  相似文献   

2.
Abstract: Samples containing the toxic castor bean protein ricin have been recently seized in connection with biocriminal activity. Analytical methods that enable investigators to determine how the samples were prepared and to match seized samples to potential source materials are needed. One commonly described crude ricin preparation method is acetone extraction of crushed castor beans. Here, we describe the use of solid‐phase microextraction and headspace analysis to determine whether castor beans were processed by acetone extraction. We prepared acetone‐extracted castor bean mash, along with controls of unextracted mash and mash extracted with nonacetone organic solvents. Samples of acetone‐extracted mash and unextracted mash were stored in closed containers for up to 109 days at both room temperature and ?20°C, and in open containers at room temperature for up to 94 days. Acetone‐extracted bean mash could consistently be statistically distinguished from controls, even after storage in open containers for 94 days.  相似文献   

3.
In the wake of terrorist attacks using anthrax and ricin, white powder is often encountered in cases of malicious mischief and terrorist threats. Wheat flour is a common white powder encountered in such criminal investigations. We used DNA analysis to investigate wheat flour samples for identification and discrimination as trace evidence. Species identification of commercially available wheat flour was carried out by sequencing a partial region of the ribulose bisphosphate carboxylase large subunit gene (rbcL). Samples were discriminated using short tandem repeat (STR) analysis. The rbcL sequences of all wheat flour samples were identical and showed a high level of similarity to known wheat (Triticum aestivum L.) sequences. Furthermore, flours had characteristic patterns in STR analyses, with specific cultivars showing distinctive patterns. These results suggested that the identification of wheat flour species is possible using rbcL sequencing, and that STR analysis is useful for discriminating between samples.  相似文献   

4.
罗芳 《刑事技术》2011,(1):16-18
目的研究尿液中甲基苯丙胺、氯胺酮、吗啡、海洛因的检验方法;方法时间编程和串联质谱技术联合分析;结果分析时间被划分成4个阶段,在每个阶段按照目标物的结构和性质确定母离子和碰撞诱导电压得到相应的子离子碎片信息;结论串联质谱和时间编程的联合分析不仅能有效的排除体内大量内源物的干扰并能同时分析多种物质,此方法应用于实际检案中快速、灵敏。  相似文献   

5.
Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.  相似文献   

6.
Methamphetamine is methylated in the presence of unbuffered formalin solutions within hours at room temperature. The product, N,N-dimethylamphetamine, is also found in human liver exposed to methamphetamine followed by incubation with formalin. In the present study, a direct mass spectrometric method was developed to identify N,N-dimethylamphetamine in human liver before and after treatment with formalin. Human liver samples were obtained from four deaths that were investigated by the West Virginia Office of Chief Medical Examiner. Full toxicological analysis was conducted on samples from the decedents and methamphetamine was among the positive findings in each case. The method used to expose liver tissue to formaldehyde involved treating a small piece of liver from each case with formalin solution (20% v/v) for 24 h at room temperature. The formalin treated tissues were homogenized and the resulting suspension was sonicated for 5 min, and then centrifuged. Supernatant aliquots were directly analyzed by electrospray ionization (ESI) mass spectrometry without chromatographic isolation. Positive ion multistage mass spectra recorded in MS, MS/MS and MS/MS/MS (MS3) modes were used to confirm the presence of N,N-dimethylamphetamine and methamphetamine in the mixture. Liver tissue not treated with formalin did not contain a detectable level of N,N-dimethylamphetamine. Decreases in methamphetamine concentrations in liver tissue resulting from treatment with formalin were measured using deuterium-labeled methamphetamine as internal standard. The method can be completed in less than 2 h on thawed tissue. The results suggest that the process of fixing tissues with formalin may lead to false negative findings for methamphetamine.  相似文献   

7.
The ability of two mass spectrometric methods, surface-assisted laser desorption/ionization-time of flight-mass spectrometry (SALDI-TOF-MS) and direct analysis in real time (DART-MS), to detect the presence of seven common explosives (six nitro-organic- and one peroxide-type) in spiked latent fingermarks has been examined. It was found that each explosive could be detected with nanogram sensitivity for marks resulting from direct finger contact with a glass probe by DART-MS or onto stainless steel target plates using SALDI-TOF-MS for marks pre-dusted with one type of commercial black magnetic powder. These explosives also could be detected in latent marks lifted from six common surfaces (paper, plastic bag, metal drinks can, wood laminate, adhesive tape and white ceramic tile) whereas no explosive could be detected in equivalent pre-dusted marks on the surface of a commercial lifting tape by the DART-MS method due to high background interference from the tape material. The presence of TNT and Tetryl could be detected in pre-dusted latent fingermarks on a commercial lifting tape for up to 29 days sealed and stored under ambient conditions.  相似文献   

8.
生物质谱技术是近年来发展较为迅速的生物分析技术之一,在对大分子生物质量测定中,其以快速、准确、灵敏等优点受到研究者的青睐。其中,液相电喷雾离子电离质谱(LC-ESI-MS)在法医DNA分析中对STR以及SNP遗传标记的检测具有独特的应用价值和广阔的应用前景。本文对ESI-MS的现状和在法医DNA分析中的应用等方面进行了综述,分析了LC-ESI-MS技术在法医学DNA分析中的优缺点,以促进其在国内法医DNA分析中的应用与发展。  相似文献   

9.
A 28-year-old white male medical student was found hanging by the neck from the bathroom closet of a hotel room. An intravenous infusion line leading from a bottle of thiamylal sodium (an ultrashort-acting barbiturate) was inserted into the antecubital vein of the left arm. Blood was analyzed for alcohol and other volatiles and for acidic, basic, and neutral drugs. Only thiamylal was detected. Thiamylal was quantified by high-performance liquid chromatography with ultraviolet detection, and its presence was confirmed by gas chromatography/mass spectrometry. The tissue distribution of thiamylal was 29 mg/L in blood, 1.4 mg/L in urine, 16 mg/L in bile, 135 mg/kg in liver, 25 mg/kg in kidney, and 0.4 mg in the stomach contents. The uptake and distribution of thiamylal is similar to thiopental. The distribution of the drug in this case was compared to that of other fatalities involving ultrashort-acting barbiturates.  相似文献   

10.
For street samples suspected of containing the phosphodiesterase-5 inhibitors sildenafil (Viagra(?)) and/or vardenafil (Levitra(?)), including powders or adulterated herbal supplements, a chemical analysis is needed to provide confirmatory identification of these illegally procured substances. Sildenafil and vardenafil are structurally similar and it is difficult to differentiate between them, as previous mass spectrometric studies have shown the two drugs to produce similar fragmentation patterns. The use of tandem mass spectrometry can produce confirmatory data, but the technique requires a high level of technical expertise. We have developed an electrospray ionization-liquid chromatography-mass spectrometry (ESI-LC-MS) method that allows differentiation between these two structurally similar molecules via in-source fragmentation in combination with an ion trap mass spectrometer. A very stable gas phase ion is formed during in-source fragmentation of vardenafil; the combination of the stability of this ion and the longer residence time for the ion in the ion trap results in a very strong signal. This feature results in a method that can provide clear differentiation between sildenafil and vardenafil while at the same time requiring less expertise from the routine analyst to confirm the presence or absence of the two compounds.  相似文献   

11.
Erythritol tetranitrate (ETN), an ester of nitric acid and erythritol, is a solid crystalline explosive with high explosive performance. Although it has never been used in any industrial or military application, it has become one of the most prepared and misused improvise explosives. In this study, several analytical techniques were explored to facilitate analysis in forensic laboratories. FTIR and Raman spectrometry measurements expand existing data and bring more detailed assignment of bands through the parallel study of erythritol [15N4] tetranitrate. In the case of powder diffraction, recently published data were verified, and 1H, 13C, and 15N NMR spectra are discussed in detail. The technique of electrospray ionization tandem mass spectrometry was successfully used for the analysis of ETN. Described methods allow fast, versatile, and reliable detection or analysis of samples containing erythritol tetranitrate in forensic laboratories.  相似文献   

12.
Gas chromatography tandem mass spectrometry (GC/MS-MS) analysis of 11-nor-carboxy-delta(9)-tetrahydrocannabinol (delta(9)-THC-COOH), the major metabolite of delta(9)-tetrahydrocannabinol, in biological samples is reported. The proposed method, using deuterated delta(9)-THC-COOH as an internal standard, is able to detect the major metabolite of cannabis derivatives at very low levels (picograms/millilitre) with high specificity. These characteristics render the proposed analytical procedure suitable for confirmatory analysis in drug testing for cannabis use.  相似文献   

13.
We present results of our study on the stability of 4-chloromethcathinone (4-CMC) in authentic postmortem peripheral blood and vitreous humor samples. The stability of 4-CMC was determined in postmortem blood samples (for a period of 90 days) and vitreous humor (30 days) at three different temperatures: −15°C, +4°C, and + 23°C. The analyses were carried out using ultra-high-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS). In both materials, the lowest 4-CMC stability was demonstrated at room temperature. The blood samples stored in a freezer (−15°C) showed stability for the entire study period (90 days), while in the case of the vitreous humor sample stored at the same temperature the concentration of the substance decreased by 53% after 30 days. The study carried out in authentic postmortem blood and vitreous humor samples confirms the previous reports of 4-CMC instability in biological material. Authors suggest that the biological material should be stored frozen until analyses are carried out as soon as possible after collection of the material.  相似文献   

14.
In sexual assault cases, lubricant trace evidence may supplement biological evidence, or may be the primary physical evidence where biological evidence is unavailable. This study considered a total of 50 lubricants from condoms and personal lubricant products available in Australia. Differentiation of the samples was attempted using fluorescence examination, Fourier transform infrared spectroscopy (DRIFTS), gas chromatography-mass spectrometry, liquid chromatography-tandem mass spectrometry, and pyrolysis gas chromatography-mass spectrometry. Eleven of the samples were uniquely identified by the analysis scheme, while the remainder of the samples were separated into nine groups. As a result of this study, a recommended protocol for the detection and analysis of an "unknown" biological swab was produced.  相似文献   

15.
目的建立了生物样品中丁丙诺啡的高效液相色谱-电喷雾串联质谱检测方法。方法样品经固相萃取提取净化、反相液相色谱分离后进行质谱检测,根据保留时间及特征离子进行定性分析,以母离子m/z468进行定量分析。结果在10-500ng/ml(ng/g)范围内峰面积与质量浓度的线性关系良好(r^2〉0.993)。在50、100、500ng/ml(ng/g)3个添加水平,尿、血、肝中丁丙诺啡的平均回收率为74%~94%,日内测定结果的相对标准偏差小于8%,日间测定结果的相对标准偏差小于10%。结论该方法简单、灵敏,特异性强,适用于生物样品中丁丙诺啡的分析检验。  相似文献   

16.
Direct analysis in real time mass spectrometry (DART‐MS) served as a method for rapid high‐throughput screening of six commercially available “Spice” products, detecting various combinations of five synthetic cannabinoids. Direct analysis in real time is an ambient ionization process that, along with high mass accuracy time‐of‐flight (TOF)‐MS to 0.0001 Da, was employed to establish the presence of cannabinoids. Mass spectra were acquired by simply suspending a small portion of sample between the ion source and the mass spectrometer inlet. The ability to test minute amounts of sample is a major advantage when very limited amounts of evidentiary material are available. In addition, reports are widespread regarding the testing backlogs that now exist because of the large influx of designer drugs. This method circumvents time‐consuming sample extraction, derivatization, chromatographic, and other sample preparative steps required for analysis by more conventional mass spectrometric methods. Accordingly, the synthetic cannabinoids AM‐2201, JWH‐122, JWH‐203, JWH‐210, and RCS‐4 were identified in commercially available herbal Spice products, singly and in tandem, at concentrations within the range of 4–141 mg/g of material. Direct analysis in real time mass spectrometry decreases the time necessary to triage analytical evidence, and therefore, it has the potential to contribute to backlog reduction and more timely criminal prosecution.  相似文献   

17.
In traditional scanning electron microscopy/energy dispersive X-ray analysis of gunshot residue (GSR), one has to cope more and more frequently with limitations of this technique due to the use of lead-free ammunition or ammunition lacking heavy metals. New methods for the analysis of the organic components of common propellant powder stabilizers were developed based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). A multiple reactions monitoring scanning method was created for the screening of akardite II, ethylcentralite, diphenylamine, methylcentralite, N-nitrosodiphenylamine, 2-nitrodiphenylamine, and 4-nitrodiphenylamine, present in standards mixtures. Five out of seven of these target compounds can be selectively identified and distinguished from the two others with a high accuracy. Samples from the hands of a shooter were collected by swabbing and underwent solid phase extraction prior to analysis. Detection limits ranging from 5 to 115 mug injected were achieved. Results from several firing trials show that the LC-MS/MS method is suitable for the detection of stabilizers in samples collected following the firing of 9 mm Para ammunitions.  相似文献   

18.
CP 47,497, a potent cannabinoid receptor type 1 agonist, is the main active ingredient in the herbal mixture “Spice” sold in European countries. The illegal use of “Spice” for its psychoactive effects has become a social issue. In this study, the in vitro metabolism of CP 47,497 was investigated in human liver microsomes to characterize the metabolic fate of CP 47,497. CP 47,497 was incubated with human liver microsomes, and the reaction mixture was analyzed using liquid chromatography‐tandem mass spectrometry. A total of eight metabolites were detected in human liver microsomes and structurally characterized based on mass spectral data. The main metabolic pathways involved hydroxylations or oxygenations. The identified metabolites were mono‐oxygenated metabolites (M1 and M4), mono‐hydroxylated metabolites (M3, M5, M6, M7, and M8), and a di‐oxygenated metabolite (M2). The detection of these metabolites could confirm the presence of CP 47,497 in biological samples; therefore, collectively, they would be excellent indicators of “Spice” drug abuse.  相似文献   

19.
Kava is an Oceanic plant in which the root is consumed as a beverage and is becoming increasingly popular. The effects of kava consumption may include sedation, euphoria, and impairment of motor coordination. This article demonstrates kava impairment through four cases of self‐reported kava use supported with Drug Recognition Expert (DRE) evaluations of each subject. Subject's urines screened negative for common drugs of abuse by immunoassay analysis. Urine from cases 3 and 4 were analyzed by liquid chromatography–tandem mass spectrometry, and gas chromatography–mass spectrometry, which yielded the presence of kavalactones. Subjects exhibited poor driving behavior and signs of intoxication. Indicators of impairment from multiple drug categories, central nervous system (CNS) depressants, CNS stimulants, and cannabis were observed, which may be consistent with the presence of multiple kavalactones and their diverse array of mechanisms of action. The consumption of kava can hinder one's ability to operate a vehicle safely.  相似文献   

20.
A preliminary study was conducted to assess the capability of a new alcohol-based tissue fixative, GenoFix, to preserve DNA from biopsy tissues stored at room temperature and/or -20 degrees C in a freezer, for subsequent short tandem repeat (STR) DNA typing analysis. Fresh human smooth muscle samples were stored at room temperature in GenoFix for one month and up to one year and seven months before being processed using the megaplex STR systems, AmpFlSTR Profiler Plus and AmpFlSTR COfiler. Alternatively, muscle tissues in GenoFix were placed at -20 degrees C in a freezer for up to 3 1/2 years following two to three months in the fixative at room temperature. DNA analysis was also carried out on tissues stored in GenoFix for one month at room temperature and subsequently paraffin-embedded and stored at room temperature for four years. The AmpFlSTR Profiler Plus and AmpFlSTR COfiler STR profiles produced, using DNA extracted from all fixed tissue samples, were of very good quality. The fluorescent signals were well balanced across the nine STR loci or six loci comprised in the megaplexes surveyed and profiles showed no differences with those observed for the control blood of the respective donor patients. Continuous exposure to GenoFix at room temperature (up to one year and seven months) did not compromise the STR typing analysis of the fixed tissues. No adverse effects were noted on the STR typeability of tissues fixed with GenoFix and stored at -20 degrees C in a freezer for up to 3 1/2 years. STR profiles generated from the paraffin-embedded tissues fixed in GenoFix were of excellent quality. This preliminary study suggests that GenoFix can be used to store tissue samples at room temperature for up to one year and seven months or at -20 degrees C in a freezer for longer storage (up to 3 1/2 years). This new and odorless tissue fixative promotes tissue and DNA preservation in a very effective manner and as such may prove useful in criminal investigations or mass disaster identifications carried out in remote locations and in which a small or large number of tissue samples are collected for further analyses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号