首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 751 毫秒
1.
This study describes the complex nucleotide sequence structure of the TCTA short tandem repeat (STR) locus, VWF2. Eight alleles of VWF2 were observed in a population of 116 unrelated Caucasian individuals. The alleles ranged in size from 150 to 178 base pairs (bp). Sequence analysis of the isolated alleles revealed two polymorphic regions that were named sub-loci VWF2-a and VWF2-b. VWF2-a is located at the 5' end of the conventional locus, whilst VWF2-b is located at the 3' end. The two sub-loci are joined by a 30-nucleotide non-polymorphic sequence which contains two additional TCTA motif repeats. A semi-nested polymerase chain reaction (PCR) was designed to amplify the VWF2-b region in conjunction with the standard VWF2 amplification. This new amplification method enabled a higher level of allele discrimination than could be achieved by assigning alleles according to size. A cohort of 99 unrelated individuals was tested with this method. VWF2-a expressed five different alleles ranging from zero motif repeats to four motif repeats, while VWF2-b alleles ranged from 8 to 14 motif repeats. Allelic configuration based on the VWF2-a and VWF2-b sub-alleles revealed 23 unique configurations out of a possible 31 for the original eight VWF2 alleles. In conclusion, the VWF2 is a highly polymorphic STR locus with potential application for forensic and parentage testing.  相似文献   

2.
The rDNA intergenic spacer (IGS) structure of Cannabis sativa was established and can be used for classification and identification of this species. In this study, DNA fragments of rDNA IGS were amplified by PCR from Cannabis sativa plant extracts and a 1387 bp fragment was obtained. DNA sequence analysis revealed six different repeat motifs. In the middle of the IGS sequence, there were three sequence motifs, and the same three sections of DNA were then repeated with minor variation in sequence. The terminal region of the IGS was composed of another three different repeat units; multiple copies of these terminal repeat motifs were present in no discernible order. Within six repeat motifs, point variations were observed in five. The DNA sequence of the locus was compared with all the plant sequences registered in GenBank by the Fasta program of GCG software with the result that this DNA fragment was significantly different from any other DNA sequence recorded to date. The most similar sequence was that of Hops (Humulus lupulus), but with a similarity of only 88.9% over 579 bp. These specific and complex variations of IGS may be related to the species and geographic distributions.  相似文献   

3.
To investigate the DNA mutation rate and pattern in the hypervariable short tandem repeat (STR) locus D12S391 and in the locus D8S1132, samples from an eastern German population (Dresden area) were analysed. A duplex PCR was applied, using short amplification products for D12S391 (129-177bp) and a modified reverse primer for D8S1132 (127-182bp). The sequences of some rare and new variant alleles are described. At the locus D12S391, 13 regular and six incomplete alleles with different lengths were found, exhibiting several sequence structures. Two isolated father/child mismatches were observed in a total of 648 meioses. Novel alleles 13.1, 14.1 and 27 were discovered at the locus D8S1132. Three parent/child mismatches were found in a total of 672 meioses.  相似文献   

4.
The rDNA intergenic spacer (IGS) structure of Cannabis sativa contains six variable repeat motifs within a locus spanning 1387 base pairs. The degree of variation of the first three motifs was examined using 77 samples from cannabis samples. The samples originated from five seizures in Taiwan and seed stocks from six different countries. The results showed that there were four types of sequences producing PCR products at either 255, 260, 264 or 265 base pairs. The data obtained indicates that this region of rDNA IGS exhibits a degree of polymorphism that while insufficient by itself can be added to a multiplex with other cannabis STR loci.  相似文献   

5.
D16S543 is a complex STR locus consisting of five types of repeat units. The frequency distribution and genetic characteristics of this locus in Japanese were investigated using blood samples from 124 unrelated Japanese and 15 families. Alleles were detected using denatured polyacrylamide gels followed by automated analysis on an ABI 373 sequencer using Genescan software 672. Twenty-one alleles were identified, ranging in size from 281 to 489 bp. An allelic ladder containing the 21 alleles was constructed and used as a typing standard. The repeat unit arrays allowed the 21 alleles to be classified into three distinct groups, including alleles 1 to 7 in group I, alleles 8 to 14 in group II, and alleles 15 to 22 in group III. The alleles in group II were characterized by the insertion of one repeat unit of CAGG, one of AAAG, and three of AAGG, while the group III alleles differed from those of groups I and II by the insertion of a total of 32 repeat units ranging in 5 types. Within each group, the alleles differed from each other only in one 5' side tetranucleotide AAGG. The power of discrimination (Pd) and the estimated heterozygosity were calculated to be 0.989 and 0.934, respectively. Typing of this locus was successfully applied in four old forensic materials. The study presented herein demonstrates that D16S543 is a highly polymorphic and applicable locus in Japanese.  相似文献   

6.
SE33 was a well-known autosomal short tandem repeat (STR) marker that was high polymorphic and therefore was high discrimination power. The sequence structure of STR markers has been increasingly explored with next-generation sequencing (NGS) technology. The sequencing resulted in the development of a new locus designation and allele nomenclature that was also backward compatible with the conventional capillary electrophoresis. SE33 was one of the STR markers that had been coamplified by Forenseq™ Signature Prep Kit (Verogen) but were not analyzed and illustrated in the Universal Analysis Software (UAS) (Verogen). This study reported an ambiguous sequence-based allele 16.3 of the SE33 locus. This allele was observed while analyzed by STRait Razor 3.0. The configuration file was modified from the previous studies to include 15 bp of 5′ flanking region and 24 bp of 3′ flanking region. The ambiguous allele was called 16.3 (106 bp) with a read count of 2070. However, the sequence of the repeat region cannot be designated as allele 16.3. Several possible scenarios for allele designation were presented and discussed.  相似文献   

7.
A duplex real-time qPCR assay was developed for quantifying human nuclear and mitochondrial DNA in forensic samples. The nuclear portion of the assay utilized amplification of a approximately 170-190 bp target sequence that spans the repeat region of the TH01 STR locus, and the mitochondrial portion of the assay utilized amplification of a 69 bp target sequence in the ND1 region. Validation studies, performed on an ABI 7000 SDS instrument using TaqMan detection, demonstrated that both portions of the duplex assay provide suitable quantification sensitivity and precision down to 10-15 copies of each genome of interest and that neither portion shows cross-reactivity to commonly encountered non-human genomes. As part of the validation studies, a series of DNase-degraded samples were quantified using three different methods: the duplex nuclear-mitochondrial qPCR assay, the ABI Quantifiler Human DNA Quantification Kit qPCR assay, which amplifies and detects a 62 bp nuclear target sequence, and slot blot hybridization. For non-degraded and moderately degraded samples in the series, all three methods were suitably accurate for quantifying nuclear DNA to achieve successful STR amplifications to yield complete profiles using the ABI AmpFlSTR Identifiler kit. However, for highly degraded samples, the duplex qPCR assay provided better estimates of nuclear template for STR amplification than did either the commercial qPCR assay, which overestimated the quantity of STR-sized DNA fragments, leading to an increased proportion of undetected alleles at the larger STR loci, or slot blot hybridization, which underestimated the quantity of nuclear DNA, leading to an increased proportion of STR amplification artifacts due to amplification of excess template.  相似文献   

8.
The locus D8S320 is an STR system first described in 1993 as a simple (AAAG) repeat. Sequencing data revealed that the D8S320 locus is a complex STR system consisting of (AAAG)- and (AAAC)-repeat units. A total of 22 different alleles were found in a population survey of 210 unrelated individuals from the Rhine area with frequencies ranging from <0.01 to 0.198. The population data revealed the existence of variant alleles differing by 1 and 2bp from the consensus allele. Due to the complex repeat structure consisting of three variable regions and one constant region, electrophoresis under denaturing conditions is strongly recommended. The statistical values were calculated to be 0.89 (observed heterozygosity rate), 0.96 (discrimination index) and 0.71 (mean exclusion chance). No deviation from Hardy-Weinberg equilibrium (HWE) was observed.  相似文献   

9.
A large number of alleles from the six different short tandem repeat (STR) loci FGA, D3S1358, vWA, CSF1PO, TPOX and TH01, used in human identity testing were sequenced to provide support for the robustness of fluorescent STR DNA typing by allele size. Sequence information for some of these loci (FGA, vWA, TH01) is an extension of published work, whereas no extensive sequence information is available with respect to the D3S1358, CSF1PO, and TPOX loci. Sequencing of alleles at each locus has provided quantitative data with respect to the true nucleotide length of common alleles, and of alleles that vary in length from the common alleles. All alleles that were identified as "off-ladder" alleles through fluorescent typing at these STR loci have proven to be true length variant alleles. Sequencing at the D3S1358 and CSF1PO loci allowed for the establishment of a common nomenclature for these loci. A correlation between percent stutter and the length of the core tandem repeat is demonstrated at the FGA locus. Alleles in which the core tandem repeat is interrupted by a repeat unit of different sequence have a reduced percent stutter. DNA samples from three non-human primates (chimpanzee, orangutan, and gorilla) were compared to the human sequences, and shown to differ markedly across loci with respect to their homology. The effects of primer binding site mutations on the amplification efficiency at a particular locus, and methods used to interpret amplification imbalance of heterozygous alleles at a locus is also addressed.  相似文献   

10.
The allelic frequency and structural characteristics of two STR loci D8S580 and D22S442 were investigated using blood samples from 143 unrelated healthy Japanese individuals. Thirty-eight alleles in D8S580 locus and 13 alleles in D22S442 locus were identified. The discrimination power, heterozygosity, and the polymorphic information content of those loci displayed high values (0.98, 0.88, and 0.87 in D8S580 and 0.97, 0.86 and 0.85 in D22S442), and their frequency distributions met Hardy-Weinberg equilibrium expectations. The allelic pattern of D8S580 was complex and differentiated into three groups (group I: alleles 184-194bp; group II: alleles 203-223, 235, 239, 243, 252 and 255bp; group III: alleles 227-286bp). Most of their alleles contained five categories of repeat units (A: aaaag; B: aaag; C: aagg; D: caag; E: agaa). On the other hand, D22S442 contained only two types of repeat units (A: agga; B: aggg). The present study, hence, proves that both D8S580 and D22S442 are highly polymorphic and represent stable genetic markers applicable to forensic investigations.  相似文献   

11.
Using the polymerase chain reaction (PCR), we studied the short tandem repeat (STR) polymorphism observed at the D12S391 locus. In 350 Japanese examined, 14 different alleles ranging from 209 bp to 261 bp were detected. Allele 18 (221 bp) showed the highest frequency at 0.30. Observed and expected values of respective genotypes satisfied the Hardy-Weinberg equilibrium (chi 2 = 24.08, P = 0.24, df = 20). In addition, 18 additional sequence structures (suballeles), were detected in this study. Within the suballeles, sequence variants, in which the initial repeat of (AGAT) was replaced with (AGGT), was found in five samples. It was found that the analysis of single-strand conformation polymorphism (SSCP) before sequence analysis was useful for distinguishing these suballeles.  相似文献   

12.
The DNA purification step has been thought to be essential for typing of STR DNA. However, this process is time-consuming, and there is a risk of unexpected cross-contamination during purification. We report a new method for direct short tandem repeat (STR) amplification using a newly developed direct PCR buffer, AnyDirect, which can amplify STR loci from whole blood and blood- or saliva-spotted FTA cards without DNA purification. The autosomal and Y chromosomal STR loci were analyzed for whole blood and blood or saliva spots of random individuals, followed by comparison of the results with those of corresponding purified DNA. The results from whole blood and blood spots showed perfect concordance with those from purified DNA without allele or locus drop-out. However, in the case of saliva spots, no amplification or locus drop-out was observed in some of the samples, which offers a topic for further study. Additionally, some commercial hot-start DNA polymerases other than AmpliTaq Gold DNA polymerase were also found to be compatible with this buffer system. Therefore, this direct PCR buffer was demonstrated to be useful for fast forensic DNA analysis or criminal DNA databases for which there is no need to store DNA samples.  相似文献   

13.
Short amplicon autosomal short tandem repeat (Mini-STR) assay has proved to be a highly useful tool in forensic applications, especially for highly degraded DNA samples that typically result in partial profiles and total loss of information from regular STR amplicons.In this study two new quadruplex systems were designed to get nuclear DNA profile from degraded forensic casework samples. In order to obtain PCR products less than 120 bp in size, primer pairs of eight STR markers, included in available commercially multiplex PCR kits, were redesigned and assembled in two PCR-multiplexes: D8S1179, D3S1358, TPOX, D16S539 and CSF1P0, TH01, D13S317, D5S818.After validation, these two Mini-STR quadruplex were employed in paternity testing case that involved DNA extraction from archival postmortem Bouin's fluid-fixed paraffin-embedded tissue where commercial kit yielded low success. The results obtained with the present Mini-STR PCR-multiplexes proved clearly demonstrating their usefulness in analyzing degraded DNA samples.  相似文献   

14.
A multiplex quantitative PCR assay has been designed to amplify target sequences of different length, which allows for the assessment of DNA degradation in samples of forensic interest. The targets were chosen to provide quantification and fragment length information relevant to the STR amplification targets commonly used for forensic genotyping. The longer target (nuTH01, 170-190 bp) spans the TH01 STR locus. Although not one of the longest loci used for STR genotyping, it was chosen as a good compromise given the target length limitations on qPCR efficiency with TaqMan detection. The shorter target (nuCSF, 67 bp) was designed in the upstream flanking region of the CSF1PO STR locus. In addition to these human nuclear targets, the assay includes an internal PCR control target sequence to allow for an assessment of PCR inhibition. The assay was rigorously tested on samples with varying amounts of degradation, and the ratio of nuCSF:nuTH01 quantifications was shown to provide a good estimation of the degree of degradation present in a sample. This estimate, along with the internal control for PCR inhibition, provides a valuable tool for post-extraction sample assessment.  相似文献   

15.
The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.  相似文献   

16.
短串联重复位点ACTBP2(SE33)的扩增片段长度多态性研究   总被引:3,自引:0,他引:3  
应用变性聚丙烯酸胺凝胶电泳(dn-PAGE)结合银染色技术对短串联重复(STR)位点ACTBP2(SE33)的扩增片段长度多态性(Amp-FLPs)进行了研究。在210名无关中国个体中观察到了25个等位基因,等位基因频率分布在0.007~0.093之间。基因型的分布符合Hardy-Weinberg定律,个体识别能力(DP)值为0.99,杂合度(H)为98.7%。七个家系分析的结果表明,该位点的遗传符合孟德尔遗传法则,未观察到变异。对几种常见的法医物证检材的分析表明,该分型系统对DNA降解放为严重的检村适用性强,而且灵敏度高(0.5ng),适合于法医学实际应用。  相似文献   

17.
A new STR typing strategy has been developed allowing the simultaneous amplification and subsequent analysis of 11 polymorphic systems with amplicon sizes smaller than 270bp. The multiplex amplification reaction includes six STR loci from the European standard set of loci (ESS) for DNA databases (D3S1358, D8S1179, D21S11, THO1, FGA and VWA) as well as four additional STR systems selected for their robustness (D2S1338, D12S391, TPOX and D5S818) together with the sex-specific locus amelogenin. After PCR amplification, the multiplex reaction is splitted into two sets of STR multiplexes by using biotin labelled primers only for one set. Using streptavidin-coated Sepharose beads five STR systems are separated from the other six systems prior to being analysed in two different runs on a capillary gel electrophoresis instrument. The multiplex system was developed and tested especially for the use in forensic casework if only limited amounts or highly degraded DNA is available, for instance, when isolated from telogen hair roots.  相似文献   

18.
荧光标记STR分型技术检验腐败组织基因型   总被引:7,自引:4,他引:3  
探讨腐败组织荧光标记STR分型检测技术的应用价值。应用含12个STR基因座及一个性别基因座的2个荧光标记的复合扩增系统,对40例1~6周的腐败肌肉提取的DNA进行扩增,用变性聚丙烯酰胺凝胶电泳,PE377测序仪分析基因型。所检测样本在12个STR基因座均扩增出特异性谱带,并可判定其基因型。荧光标记STR检测技术对腐败组织分型可靠,在实际检案中具有较高的应用价值。  相似文献   

19.
Allele frequency distributions of nine short tandem repeat (STR) loci, D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D7S820, and D13S317, HLA-DQA1 and polymarker (PM) loci were studied in a sample population from Sultanate of Oman, Middle East. Blood samples were collected from 162 unrelated individuals. For all STR, HLA-DQA1 and PM loci, no deviations from Hardy-Weinberg equilibrium, based on the exact test, were observed. The most discriminating loci were D18S51 (PD=0.966) and FGA (PD=0.964), while the least informative locus is GYPA (PD=0.585). The allele frequency data may be useful in forensic case work.  相似文献   

20.
We examined the complex short tandem repeat (STR) locus at the 3'-flanking region of the neurotensin receptor (NTR) gene. The polymorphism of this locus was first reported as a simple tetranucleotide repeat variation by Le et al., but it also offers a surprisingly informative variation, that permits reliable individual identification by two complementary strategies: fluorescent-labelled polymerase chain reaction (PCR)/electrophoresis and direct sequencing of the PCR products. We determined the alleles in 203 Japanese by fluorescent-labelled PCR/electrophoresis. Determination was based on their length with a reliability of +/-1 bp, and the frequency of each allele was very low. Sequencing analysis further grouped these alleles in detail. Sequencing demonstrated that the locus varied by six repetitive units and three insertion/deletion positions of nucleotide fragments. We detected multiple alleles having different structures even in the same allele length. We found structural differences in homozygous alleles having the same base pair size. We also determined that apparently homozygous alleles were heterozygous from sequencing electropherograms showing an overlap of nucleotides or +/-1 bp difference. These results indicate that this locus is structurally hypervariable in addition to having allelic length variations, promising a great advance in individual identification in forensic practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号