首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract: The PrepFiler? Forensic DNA Extraction Kit enables isolation of genomic DNA from a variety of biological samples. The kit facilitates reversible binding of DNA with magnetic particles resulting in high DNA recovery from samples with very low and high quantities of biological materials: 0.1 and 40 μL of human blood (donor 2) provided 14 and 2883 ng of DNA, respectively. Following the revised SWGDAM guidelines, performance of the developed method was investigated using different sample types including saliva on swabs, semen stains on cotton fabric, samples exposed to environment, samples with polymerase chain reaction (PCR) inhibitors, blood stains (on denim, cotton cloth, and FTA® paper), and touch evidence‐type samples. DNA yields for all samples tested were equal or better than those obtained by both phenol–chloroform extraction and commercial kits tested. DNA obtained from these samples was free of detectable PCR inhibitors. Short tandem repeat profiles were complete, conclusive, and devoid of PCR artifacts.  相似文献   

2.
Five DNA extraction systems were assessed for their DNA extraction efficiency on samples of fresh pig bone. Four commercially available silica-based extraction kits (ChargeSwitch® gDNA Plant Kit (Life Technologies), DNA IQTM System Kit (Promega), DNeasy® Blood & Tissue Kit (Qiagen) and PrepFiler® BTA Forensic DNA Extraction Kit (Life Technologies)) and a conventional phenol-chloroform method were tested in this study. Extracted DNA samples were quantitated with GoTaq® qPCR Master Mix (Promega) using an Applied Biosystems® 7500 Real-Time PCR System and the extracts were amplified using an in-house multiplex system. The phenol-chloroform extraction produced higher yields of DNA than the silica-based extraction methods. Among the silica-based extractions ChargeSwitch® gDNA Plant Kit recovered the highest amounts of DNA. However, all methods produced DNA that could be amplified and none of the extracts contained any detectable inhibition.  相似文献   

3.
Forensic evidence samples are routinely found as stains on various substrates, which may contain substances known to inhibit polymerase chain reaction (PCR). The goal of this study was to evaluate post‐Chelex®100 purification using powdered activated carbon (PAC). Mock crime scene DNA extracts were analyzed using quantitative PCR and short tandem repeat (STR) profiling to test the DNA recovery and inhibitor removal using PAC with those of the Amicon®Ultra 100K. For extracted bloodstains on soil and wood substrates, PAC and Amicon®Ultra 100K generated similar DNA yield and quality. Moreover, the two methods significantly decreased the concentration of humic substances and tannins compared to nonpurified extracts (< 0.001). In instances where extracts contained indigo dye (bloodstains on denim), Amicon®Ultra 100K performed better than PAC due to improved amplifiability. Efficient adsorption of humic substances and tannins, which are common inhibitors, indicates PAC's potential application in the purification of high‐template DNA extracts.  相似文献   

4.
Abstract: Forensic anthropologists routinely macerate human bone for the purposes of identity and trauma analysis, but the heat and chemical treatments used can destroy genetic evidence. As a follow‐up to a previous study on nuclear DNA recovery that used pig ribs, this study utilizes human skeletal remains treated with various bone maceration techniques for nuclear DNA amplification using the standard Combined DNA Index System (CODIS) markers. DNA was extracted from 18 samples of human lower leg bones subjected to nine chemical and heat maceration techniques. Genotyping was carried out using the AmpF?STR® COfiler® and AmpF?STR® Profiler Plus® ID kits. Results showed that heat treatments via microwave or Biz/Na2CO3 in sub‐boiling water efficiently macerate bone and produce amplifiable nuclear DNA for genetic analysis. Long‐term use of chemicals such as hydrogen peroxide is discouraged as it results in poor bone quality and has deleterious effects on DNA amplification.  相似文献   

5.
The aim of this work was to optimize a strategy for detection, collection, and analysis of touch DNA traces. 4N6FLOWSwabs™ and cotton swabs were compared by collecting touch DNA traces from glass slides and gun shell casings. Shed cells were visualized using Diamond™ nucleic acid dye and a digital fluorescent microscope. Different collection and extraction methods were tested. Collected samples were amplified with the AmpFlSTR® NGMSElect™ kit and the Precision ID mtDNA Whole Genome Panel.  相似文献   

6.
The limits of the expert system, TrueAllele® Casework (TA), were explored using challenging mock casework profiles that included 17 single‐source and 18 two‐, 15 three‐ and 7 four‐person DNA mixtures. The sensitivity (ability to detect a minor contributor) of the TA analysis process was examined by challenging the system with mixture DNA samples that exhibited allelic and locus dropout and other stochastic effects. The specificity (ability to exclude nondonors) was rigorously tested by interrogating TA derived genotypes with 100 nondonor profiles. The accuracy with which TA estimated mixture weights of contributors to the two‐person mixtures was examined. Finally, first‐degree relatives of donors were used to assess the ability of the system to exclude close relatives. TA demonstrated great accuracy, sensitivity, and specificity. TA correctly assigned mixture weights and excluded nearly all first‐degree relatives. This study demonstrates the analysis power of the TrueAllele® Casework system.  相似文献   

7.
Abstract: The choice of reagents for presumptive tests for blood, and subsequent extraction methodologies, can significantly affect both the quantity and quality of purified DNA. Blood samples directly tested with Hemastix® yielded <1% of the DNA recovered from untested samples when purified using the Qiagen BioRobot® EZ1 and EZ1® DNA Investigator kit. Full short tandem repeat profiles were obtained from both tested and untested samples, suggesting that the Hemastix® reagent(s) affect DNA binding, rather than produce DNA damage. The Hemastix® inhibition of DNA yield could be overcome by the addition of MTL buffer to the sample prior to extraction. Laboratories may wish to modify current procedures for extracting blood samples, utilize other extraction/purification methodologies, or inform their submitting agencies to avoid direct exposure of questioned bloodstains to Hemastix® reagents.  相似文献   

8.
Abstract: Obtaining complete short tandem repeat (STR) profiles from fingerprints containing minimal amounts of DNA, using standard extraction techniques, can be difficult. The aim of this study was to evaluate a new kit, Fingerprint DNA Finder (FDF Kit), recently launched for the extraction of DNA and STR profiling from fingerprints placed on a special device known as Self‐Adhesive Security Seal Sticker® and other latent fingerprints on forensic evidentiary material like metallic guns. The DNA extraction system is based on a reversal of the silica principle, and all the potential inhibiting substances are retained on the surface of a special adsorbent, while nucleic acids are not bound and remain in solution dramatically improving DNA recovery. DNA yield was quite variable among the samples tested, rendering in most of the cases (>90%) complete STR profiles, free of PCR inhibitors, and devoid of artifacts. Even samples with DNA amount below 100 pg could be successfully analyzed.  相似文献   

9.
DNA profiles have been obtained from fingerprints, but there is limited knowledge regarding DNA analysis from archived latent fingerprints—touch DNA “sandwiched” between adhesive and paper. Thus, this study sought to comparatively analyze a variety of collection and analytical methods in an effort to seek an optimized workflow for this specific sample type. Untreated and treated archived latent fingerprints were utilized to compare different biological sampling techniques, swab diluents, DNA extraction systems, DNA concentration practices, and post‐amplification purification methods. Archived latent fingerprints disassembled and sampled via direct cutting, followed by DNA extracted using the QIAamp® DNA Investigator Kit, and concentration with Centri‐Sep? columns increased the odds of obtaining an STR profile. Using the recommended DNA workflow, 9 of the 10 samples provided STR profiles, which included 7–100% of the expected STR alleles and two full profiles. Thus, with carefully selected procedures, archived latent fingerprints can be a viable DNA source for criminal investigations including cold/postconviction cases.  相似文献   

10.
In forensic DNA casework, the interpretation of an evidentiary profile may be dependent upon the assumption on the number of individuals from whom the evidence arose. Three methods of inferring the number of contributors—NOCIt, maximum likelihood estimator, and maximum allele count, were evaluated using 100 test samples consisting of one to five contributors and 0.5–0.016 ng template DNA amplified with Identifiler® Plus and PowerPlex® 16 HS. Results indicate that NOCIt was the most accurate method of the three, requiring 0.07 ng template DNA from any one contributor to consistently estimate the true number of contributors. Additionally, NOCIt returned repeatable results for 91% of samples analyzed in quintuplicate, while 50 single‐source standards proved sufficient to calibrate the software. The data indicate that computational methods that employ a quantitative, probabilistic approach provide improved accuracy and additional pertinent information such as the uncertainty associated with the inferred number of contributors.  相似文献   

11.
In forensic science, biological material is typically collected from evidence via wet/dry double swabbing with cotton swabs, which is effective but can visibly damage an item's surface. When an item's appearance must be maintained, dry swabbing and tape‐lifting may be employed as collection techniques that are visually nondestructive to substrates' surfaces. This study examined the efficacy of alternative swab matrices and adhesive lifters when collecting blood and fingerprints from glass, painted drywall, 100% cotton, and copy paper. Data were evaluated by determining the percent profile and quality score for each STR profile generated. Hydraflock® swabs, BVDA Gellifters®, and Scenesafe FAST? tape performed as well as or better than cotton swabs when collecting fingerprints from painted drywall and 100% cotton. Collection success was also dependent on the type of biological material sampled and the substrate on which it was deposited. These results demonstrated that alternative swabs and adhesive lifters can be effective for nondestructive DNA collection from various substrates.  相似文献   

12.
DNA IQ磁珠法结合Maxwell~(TM) 16自动仪提取接触DNA   总被引:1,自引:0,他引:1  
目的研究DNA IQ磁珠法结合MaxwellTM 16自动仪对接触DNA提取的应用价值。方法 151份案件接触DNA检材95℃裂解后,采用DNA IQ磁珠法结合MaxwellTM 16自动仪提取DNA,然后进行DNA定量和STR分型检测,统计各种类型的接触DNA含量I、PC CT值和STR分型成功率。结果 151份案件接触DNA检材中,除果核平均DNA获得量为9.51ng以外,其它接触检材的平均DNA获得量均大于10ng,烟蒂检验成功率最高为93%,果核检验成功率较低,为60%。所有DNA样品的IPC CT值均在27左右,纯度高。结论大部分接触DNA检材采用DNA IQ磁珠法结合MaxwellTM 16自动仪可提取到足以进行STR分型的DNA。  相似文献   

13.
In forensic science, fingerprints are a common source of evidentiary information. However, latent examination is not always successful and trace human DNA cannot always be obtained. Thus, examining the fingerprint microbiome may offer a suitable alternative to more traditional methods of forensic identification. The Zymo Research ZR Bacterial/Fungal DNA MicroPrep™ Kit, Qiagen QIAmp® DNA Mini Kit, Promega Wizard® Genomic DNA Purification Kit, and the MPBio FastDNA® Spin Kit were compared for their ability to yield a sufficient amount of bacterial DNA for next-generation sequencing in order to obtain a microbiome profile. Prints were deposited onto slides, allowed to sit for up to 1 month, and total DNA isolated and quantified using each kit. The kit from Zymo Research yielded the most concentrated DNA sample (0.0084 ng/µL) in the least amount of time as compared to other kits examined. Although this amount of DNA was far below the recommended DNA concentration threshold recommended for next-generation sequencing, a microbiome profile was successfully obtained. As interest in using the microbiome of an individual as a forensic tool continues to increase, there is the possibility that the microbiome of a fingerprint could complement traditional human DNA profiling in the future. This study provides evidence that trace amounts of bacterial DNA from fingerprints is quantifiable and sufficient for microbiome analysis.  相似文献   

14.
Abstract: The quality and efficiency of a standard organic DNA isolation method and a silica‐based method using the QIAGEN Blood Maxi Kit were compared to obtain human DNA and short tandem repeats (STRs) profiles from 39 exhumed bone samples for paternity testing. DNA samples were quantified by real‐time PCR, and STR profiles were obtained using the AmpFlSTR® Identifiler® PCR amplification kit. Overall, the silica‐based method recovered less DNA ranging from 0 to 147.7 ng/g (average 7.57 ng/g, median = 1.3 ng/g) than did the organic method ranging from 0 to 605 ng/g (average 44.27 ng/g, median = 5.8 ng/g). Complete profiles (16/16 loci tested) were obtained from 37/39 samples (95%) using the organic method and from 9/39 samples (23%) with the silica‐based method. Compared with a standard organic DNA isolation method, our results indicate that the published silica‐based method does not improve neither the quality nor the quantity of DNA for STR profiling.  相似文献   

15.
This investigation evaluated the use of a freezer mill to improve retrieval of DNA from dried cotton swabs (using 100 μl saliva) compared to uncrushed swabs and whole saliva by measuring DNA yield and profile average peak height. Three treatments were tested; short, medium (as for a bone sample) and extended. The samples subjected to the freezer mill had the powder that remained on the freezer mill components collected (using a water and agitation method). All freezer mill samples returned a lower average DNA yield than either uncrushed swabs or whole saliva. The powder from the crushed swabs comprised an average of 35% of the total DNA yield, whereas the powder from the components comprised 65%. Allele drop-out was observed in samples exposed to extended treatments. Both short and medium treatments provided significantly higher peak heights than uncrushed cotton swabs with equal quantities of DNA (P < 0.05). Using a freezer mill on dried cotton swabs does not increase the DNA yield. This investigation suggests collecting powder from the freezer mill components will increase DNA yield, especially from trace samples.  相似文献   

16.
In this study, DNA was extracted using an AutoMate Express? and an EZ1 Advanced XL from liquid blood, fresh and aged bloodstains, and fresh and aged semen stains. Extracted DNA was quantified by real‐time PCR using the D17Z1 locus. Short tandem repeat typing was performed using an AmpF?STR® Identifiler kit. The yields of DNA obtained by the AutoMate Express? were higher from fresh bloodstains and fresh semen stains, almost the same from aged bloodstains and aged semen stains, but slightly lower from liquid blood compared with those obtained by the EZ1 Advanced XL. The addition of dithiothreitol or the use of PrepFiler? lysis buffer improved the EZ1 Advanced XL results from fresh bloodstains, but not for liquid blood and aged bloodstains. Our results demonstrated that the PrepFiler? lysis buffer is the main contributor to the higher DNA yields of the AutoM ate Express? for fresh bloodstains.  相似文献   

17.
Abstract: The AmpF?STR® Identifiler® Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single‐source blood and buccal samples on FTA® card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay’s sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA® cards, and the assay’s specificity was verified by establishing minimal cross‐reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA® substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler® Direct Kit for forensic standards and database samples genotyping.  相似文献   

18.
目的比较3种常见的接触检材前处理方式对磁珠法提取DNA效果的影响。方法收集烟蒂、牙刷、纱线手套各10份;分别采用95℃、70℃直接裂解和TNE、SDS、PK预消化方式进行前处理,再用磁珠法提取纯化DNA,并进行DNA定量,统计提取的接触DNA量和IPC CT值;同时用Sinofiler复合扩增系统进行STR分型检测。结果 3种方法前处理后用磁珠提取的DNA纯度均较高I,PC CT值在26.63~27.19之间。用预消化法获得的DNA量高于裂解法,而95℃裂解与70℃裂解方法提取的DNA量无显著性差异。STR扩增检测结果亦表明,采用预消化法处理的样品STR分型成功率高于裂解法9,5℃与70℃裂解方法处理的样品STR分型成功率无显著性差异。结论人体接触检材采用预消化磁珠法提取DNA,有助于提高STR检验成功率。  相似文献   

19.
Abstract: Laboratory automation has the ability to increase the throughput and efficiency of laboratory processes to keep pace with current backlogs and requests for analysis. This paper addresses the specific studies employed to properly evaluate an automated method for DNA quantitation setup using Applied Biosystems Quantifiler? Human DNA Quantification kit on a Biomek® 3000. The calibration of robotic pipetting as well as comparison with manually performed steps confirmed the accuracy of the automated methods used. Reproducibility studies evaluated differences between robotic and manually prepared human DNA standard curves. Additional studies examined DNA samples of known quantities, extract storage formats, sensitivity, and an assessment of contamination. The Biomek® 3000 not only demonstrated reproducibility and accuracy that equaled or surpassed the manual method but also revealed a contamination‐free method to replace the multiple pipetting steps required during quantitation setup.  相似文献   

20.
A new rapid DNA solution, the RapidHIT®ID, can accommodate two different sample cartridges, ACE, for the analysis of a single swab and EXT, for the analysis of DNA extracts. An efficient internal validation designed for low‐throughput rapid DNA is described. An evaluation of the EXT sample cartridge is also described. Each cartridge generated profiles with sufficient data quality to meet CODIS eligibility in fewer than 120 min. The results exhibited 100% correlation when compared to conventional DNA typing methods. Precision, reproducibility, stochastic, mixture, and contamination experiments produced expected results. Sensitivity of the ACE sample cartridge was acceptable for buccal swab analysis. The sensitivity of the EXT sample cartridge is discussed. The ACE validation and the EXT evaluation utilized a minimalist, cost‐saving, efficient design to generate a validated RapidHIT®ID instrument capable of producing genetic profiles from both extracted forensic DNA samples and buccal swab samples within 120 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号